torqeedo Power 48-5000 Battery Switch Instruction Manual
- June 11, 2024
- torqeedo
Table of Contents
Power 48-5000 Battery Switch
Instruction Manual
Power 48-5000 Battery Switch
This installation drawing is an addition to the original operating
instructions. Read operating instructions before wiring.
NOTE! When using only one Power 48-5000 battery, the system will be
limited to 6kw maximum output. This installation drawing is an addition to the
original operating instructions.
Read operating instructions before wiring.
NOTE! When using only one Power 48-5000 battery, the system will be
limited to 6kw maximum output.
Option: One charger for each battery This installation drawing is an addition
to the original operating instructions.
Read operating instructions before wiring.
This installation drawing is an addition to the original operating
instructions.
Read operating instructions before wiring.
** In case the charger is permanently installed in the boat, the charger
housing or its AC PE and battery minus pole must be connected to the common
grounding point. The AC connection requires specialist knowledge and may only
be carried out by qualified personnel.
If necessary, have the planning and installation carried out by a specialist.
NOTE!** To charge the batteries in the boat, a land connection in the boat
with galvanic isolator or isolation transformer is required according to
applicable national requirements (e.g. DIN EN ISO 13297, ABYC E-11).
Connect the charger housing and the minus battery pole to the common
grounding point.
25 mm2 grounding cable System ground connection
This installation drawing is an addition to the original operating
instructions. Read operating instructions before wiring. Bus
system termination resistor
This installation drawing is an addition to the original operating
instructions. Read operating instructions before wiring.
Pos. | Item number Name | Remarks |
---|---|---|
1 | 1213340 | raise 12.0 EPTorgLink with electronic box |
HA. .1. K. L. | Cable set with battery switch |
picture for cable length
o| | BadcboneTorqiink cable 8-pin| 3000 mm
| 2104 – 00| Power 48-5000| SelectTorgLink-Battery in
throttle menu! NOTEI When using only one Power 48-5000 battery, the
system will be limited to 6kw maximum output
a| | FCable 8-pin 900 mm/50 mm, Do not extend I
not Illus trated| | + Battery pole adapter Not needed for your
configuration
– Battery pole adapter
W| | System ground| min. 25 mm2, not included
4| 1952-00| ThrottleTopmountTwIn|
22| 000-00858| Gateway|
U| | Gateway Power cable| 1700 mm cable
b| | BackboneTorqiink cable 8-pin| 5000 mm
17| | Emergency switch with cable| 1000 mm
20| | Key switch|
g| | Cable for key switch 6-Pin to 8-pin| 1000 mm
14| 000-00877| TomUnkTerminator – RvIn| Bus
termination resistor
a| | T-Cable 8-pin 900 mm/50 mm, Do not extend I
6| 2213-00| Charger Power 48 650W, for AC charging while running
use Fast charger Power 48 2212-00; Not compatible with solar charger 2218-00
P| | + DC charge cable 1300 mm; Do not extend!
CI| | – DC charge cable| 1300 mm; Do not extend!
B+| | + Battery pole| 7,5 Nm
B-| | – Battery pole| 7,5 Nm
AC| | AC power cable| 2000 mm
a| | T- :able 8-pin| 900 mm/50 mm, Do not extend!
Pos.| Item number| Name| Remarks
---|---|---|---
Optional equipment
7| 2212-00| Fast charger Power 48| 2900W
P| | + DC charge cable| 2400 mm; Do not extend!
Q| | – DC charge cable| 2400 mm; Do not extend!
Si-| | + Battery pole| 7,5 Nm
B-| | – Battery pole| 7,6 Nm
AC| | AC power cable| 1000 mm
a| | T-Cable 8-pin| 900 mm/50 mm, Do not extend!
8| 2218-00| Solar charge controller for 1 Power
48-5000| ForTorqLink system only! Only as stand alone charger or in
combination with 2212-00 Fast charger Power 48!
P| | + Charge cable 1500 mm
Q| | – Charge cable 1500 mm
R| | + Input solar cable 150 mm
S| | – Input solar cable 150 mm
a| | T-Cable** 8-pin 900 mm/50 mm, Do not extend!
This installation drawing is an addition to the original operating
instructions.
Read operating instructions before wiring.
Connect the cruise motor and terminator to each end of the backbone. The
TorqLink bus system requires a terminator (terminating resistor) at both ends
of the backbone in order to function correctly.
One of the terminators is located in the „Terminator Single“, „Terminator
Twin“, „Throttle 1918-00“, „ Throttle 1976-00“ , the other is built into the
cruise motor. Therefore, when installing, make sure that the components
„Terminator“ and „Cruise motor“ are each connected to one end of the backbone.
The connection position of the remaining components on the backbone can be
freely selected. Keep the following points in mind when planning:
-
An earthing point is required for your Torqeedo system. Take into account the connection and the cables required for this in your planning. The required cable cross-sections can be found in the section Tools, equipment and material.
-
First determine and plan the installation positions of all components.
-
Measure the required length of the TorqLink backbone.
-
Measure the lengths of all required stub lines (cable connection between component and TorqLink backbone).
-
When planning, please note that TorqLink drop cables must not be extended. If necessary, plan the TorqLink backbone so that the components can be connected through the
TorqLink drop cable without an extension. If necessary, extend the TorqLink backbone to connect a component that is far away; you can find corresponding extensions in our accessories catalogue. -
Cables must be fixed every 400 mm, plan attachment material. In places where fastening is not possible, a scuff guard must be fitted.
-
Openly laid cables (e.g. inflatable boat) must be protected with chafing protection, plan sufficient material.
-
When planning, please note not to bundle power cables with data or antenna cables (e.g. radios) for other loads.
-
Observe the minimum bending radius of the cables when planning.
-
If a second earthed onboard power system is available, ensure that both systems use a common earthing point.
-
Live parts must be fitted or installed with protection against accidental contact; the necessary installation space must be taken into account during the planning stage.
-
Always connect batteries as the last component to the system to avoid short circuits and voltage peaks.
-
Do not extend drop cables, extend backbone if necessary.
-
Protect plugs and contacts against contamination before installing them.
-
Do not pull at the cables.
-
Do not twist cables.
-
Do not install cables in permanently wet areas such as bilges.
-
Install cables free of chafing and not around sharp edges, if necessary, attach chafing protection.
-
Maintain bending limits.
-
Install plug connections free of tension and load.
Observe the minimum bending radius when laying all cables:
Torqeedo data cable | 8 x diameter |
---|---|
Torqeedo power cable | 8 x diameter |
Earth cable | see cable manufacturer’s specifications |
Other power cables | see cable manufacturer’s specifications |
This installation drawing is an addition to the original operating
instructions.
Read operating instructions before wiring. Option: One charger for each
battery