Gas Mask 6502QL Half Face Respirator Instructions

June 17, 2024
Gas Mask

Gas Mask 6502QL Half Face Respirator

Gas-Mask-6502QL-Half-Face-Respirator-product

Specifications

  • Product Name: 6502QL Half Face Respirator
  • Filter Type: 2097 Filter
  • Filter Function: Effectively filter all kinds of particles including dust, asbestos, welding smoke, metal salt, oily particles, and radioactive particles

Product Usage Instructions

Assembly Instructions

  1. Align the cartridge or filter notch with the facepiece mark.
  2. Turn the cartridge or filter 1/4 turn clockwise to secure it in place.
  3. To remove the cartridge, turn it 1/4 turn counterclockwise.
  4. Repeat the above steps for the second cartridge or filter.

Use Instructions

  1. Read and understand the user instructions before using the respirator.
  2. Follow all instructions and restrictions during use to ensure the proper efficacy of the respirator.
  3. Before use, receive proper training on the correct usage of the respirator.
  4. If you smell or taste contaminants, or experience dizziness, suffocation, or any other distress, leave the contaminated area immediately.
  5. When not in use, store the respirator away from contaminated areas.

Use Limitations

  1. This respirator does not supply oxygen. Do not use it in atmospheres containing less than 19.5% oxygen.
  2. If the type or concentration of pollutants is unknown or exceeds the protection object or concentration range of this respirator, do not use it.
  3. Do not alter, abuse, or misuse this respirator.

Warm Tips
The respirator itself has no smell. However, some customers may be more sensitive to smell. To eliminate odors, you can clean the facepiece (excluding filters and cartridges) or place it in a ventilated area to release any peculiar smells.

Assembly Instructions

Gas-Mask-6502QL-Half-Face-Respirator-fig-1

  1. Align the cartridge or filter notch with the facepiece mark.
  2. Turn the cartridge or filter 1/4 and turn clockwise to stop. To remove the cartridge, turn 1/4 turn counterclockwise.
  3. Repeat with a second cartridge or filter.

Tightness Test

  1. Put the headband rack on the back of the head, pull back the buckle of the elastic band, and make the respirator buckle the mouth, nose, and chin.
  2. Pull the lower elastic band to the back of the neck, tighten the fasteners, and adjust the length of the elastic band to make the face comfortable.
  3. Breathe vigorously, check the leakage between the respirator and the face, and adjust to the ideal state.
  4. If the sealing state is not ideal, do not enter the contaminated area, and re-adjust or replace the respirator.

2097 Filter: Effectively filter all kinds of particles: dust, asbestos, welding smoke, metal salt, oily particles, radioactive particles

Cleaning

  1. Remove cartridges and/or filters.
  2. Clean facepiece (excluding filters and cartridges). By immersing in a warm cleaning solution, the water temperature does not exceed 120’F. and scrub with a soft brush until clean.
  3. Rinse in fresh. warm water and air dry in a non-contaminated atmosphere.
  4. The cleaned respirator should be stored away from contaminated areas when not in use.

Attention

  1. The cartridge or filter should be changed regularly according to the operating environment.
  2. The respirator should be cleaned and maintained regularly.
  3. Check before using each time to ensure its function is intact. If it is damaged, it should be discarded immediately.
  4. The respirator should be kept in a ventilated and cool place to avoid the environment of high temperature, sunlight, high humidity and ultra-low temperature.
  5. The filter shall be kept in a sealed package, and the validity period of the filter in an unopened state is 5 years.

FAQ

Frequently Asked Questions

  • Q: Can I use this respirator in environments with low oxygen levels?
    • A: No, this respirator does not supply oxygen. Do not use it in atmospheres containing less than 19.5% oxygen.
  • Q: Can I use this respirator if I am unsure about the type or concentration of pollutants present?
    • A: No, if the type or concentration of pollutants is unknown or exceeds the protection range of this respirator, it should not be used. Please ensure proper knowledge of the pollutants before using the respirator.
  • Q: How should I clean the respirator?
    • A: Remove the cartridges and/or filters. Clean the facepiece (excluding filters and cartridges) by immersing it in warm cleaning solution, ensuring that the water temperature does not exceed 120°F (48.9°C). Scrub gently with a soft brush until clean. Rinse thoroughly in fresh warm water and allow it to air dry in a non-contaminated atmosphere.
  • Q: Can I alter or misuse the respirator?
    • A: No, altering, abusing, or misusing the respirator is not allowed. Follow all instructions and restrictions to maintain proper efficacy and safety.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals