Product Specifications

  • Product Size: 110mm x 98mm x 48mm
  • Packing Size: 140mm x 130mm x 81mm
  • Net Weight: Refer to label
  • Input Power: 100-240V 50/60HZ 450mA
  • Battery Capacity: 1400mAh
  • Operating Temperature Range: -5°C to +45°C
  • Measuring Range:
    • PM2.5: 0-35, 36-75, 76-100, 100+
    • HCHO: 0.07, 0.08-0.10, 0.10+
    • CO2: 400-1000, 1001-1500, 1501-2000, 2000+
    • TVOC
    • Temperature: -9-50°C
    • Humidity: 0-99%RH

Product Function and Usage
The Air Detector is designed to monitor air quality by measuring various parameters such as PM2.5, HCHO, CO2, TVOC, temperature, and humidity. It helps users understand the level of air pollution and take necessary actions to improve indoor air quality.

Hazardous Substances in the Product:

Name of Part Pb Hg Cd Cr(VI) PBB PBDE
Case 0 0 0 0 0 0
Screen 0 0 0 0 0 0
Circuit Board 0 0 0 0 0 0
Battery 0 0 0 0 0 0

Product Usage Instructions

FCC Warning Statement:
Please adhere to all FCC guidelines and warnings provided in the user manual.

Precautions :

  1. Do not use in the bathroom or wet environments to prevent damage.
  2. Avoid exposing the product to rainwater or wet conditions.
  3. Place the product on a stable surface at least 20cm above the ground for optimal performance.
  4. Avoid using the product in areas with heavy oil smoke to prevent blockage of air intake.
  5. Use only original USB cables to avoid safety hazards.
  6. Avoid using harsh chemicals or sprays on the product to prevent damage and accidents.
  7. Avoid inserting foreign objects into ventilation holes to maintain proper airflow.
  8. Keep the product out of children’s reach and ensure it is securely placed to prevent accidents.
  9. If the air quality level indicator turns red, ventilate the room immediately for health safety.

Frequently Asked Questions (FAQ)

Troubleshooting:

  • Fault: Unable to boot
  • Reason: No power
  • Solution: Check power source and reset the charger if needed.
  • Fault: Unable to charge
  • Reason: Charger not properly connected
  • Solution: Ensure charger is properly connected and functioning correctly.
  • Fault: Unable to connect to WiFi
  • Reason: Wrong password entered
  • Solution: Re-enter correct WiFi password and ensure router connectivity.
  • Fault: APP cannot display product data
  • Reason: Router not connected to the internet
  • Solution: Ensure router is connected to the internet for data display.
  • Fault: Unable to connect to server cloud
  • Reason: Disconnected from WiFi
  • Solution: Reconnect to WiFi network and try again.
  • Fault: Air Quality Monitor APP download
  • Solution: Download the Air Quality Monitor APP from the designated platform for your device.
  • Fault: Product info
  • Solution: Refer to the user manual for detailed product information and instructions on usage.

Thank you for choosing our product. For optimal performance, please follow the provided instructions carefully.

Air Quality Monitor

Thank you for choose our product, in order to use this product better, please read the instruction manual carefully

FCC Warning Statement

  • Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This equipment has been tested and found the comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
  • This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception , which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
    • Reorient or relocate the receiving antenna.
    • Increase the separation between the equipment and receiver.
    • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
    • Consult the dealer or an experienced radio/TV technician for help.

FCC Radiation Exposure Statement
The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co- located for operating in conjunction with any other antenna or transmitter. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

Precautions

  1. Do not use in the bathroom or wet environment, it may affect the life of the product.
  2. The product is not waterproof, please avoid rainwater and other use environments.
  3. In order to ensure the stable operation of the product, please place the product on a horizontal plane and a height of more than 20cm above the ground.
  4. Do not use it in a place where a lot of oil smoke is generated (such as the kitchen) to avoid blocking the air intake of the product.
  5. Do not use USB cables that are not original products to avoid danger.
  6. Do not use gasoline, paint thinner, etc. to wipe the product, and do not spray pesticides on the product, otherwise it may cause surface cracks, product failure, fire and other accidents, and will have a significant impact on data detection.
  7. Do not insert fingers or other foreign objects into the ventilation holes at the rear of the product, and there should be no obstacles blocking the air inlet and outlet at a distance of 5cm from the rear.
  8. Please place the product in a place out of reach of children, and ensure that the product is placed smoothly and not easily dropped to prevent injury.
  9. When the IAQ air quality level color ring turns red, the indoor space you are in may be in a state of heavy pollution, which is not good for your health. You should turn on the fresh air system or open windows for ventilation!
  10. When you use the device, water vapor must not condense on the carbon dioxide sensor. The condensed water vapor or the water marks left after evaporation will seriously affect the accuracy of the measured values of the detector, and may not be repaired!
  11. Do not put the device close to your face, the carbon dioxide exhaled by the human body will affect the accuracy of the detector readings.

Special Note:

  • If the air detector you purchased contains formaldehyde and TVOC (total volatile organic compounds) detection indicators, because it uses an accurate electrochemical sensor, it is normal for the measured value to be large for the first use. Please connect the power supply and keep it turned on. And placed in a ventilated place, the gas index will tend to normal after 48 hours of continuous operation.
  • When perfumes, cosmetics, whiteboard pens and other items containing organic compounds are close to the product, the detection value may increase instantaneously, which is a normal phenomenon. It will gradually return to normal after the source leaves.

Air Detector Explanatory Chart

FOBShanghai-HUA6-Air-Detector-fig- \(2\) Air Detector Explanatory Chart

Product specifications

  • Product size:(LWH)110mm98mm48mm
  • Packing size:( LWH)140mm130mm81mm
  • Net weight: Refer to label
  • Input power:100-240V 50/60HZ 450mA
  • Saving temperature range:-20℃~+50℃
  • Battery capacity:1400mAh
  • Input power:5V/2A
  • USB cable: micro USB, cable length:1000mm
  • Output Power:5V2000mA
  • Operating temperature range:-5℃~+45℃

Measuring range

FOBShanghai-HUA6-Air-Detector-fig-06

Air Quality Level

FOBShanghai-HUA6-Air-Detector-fig- \(4\)

Product function and usage

  1. IAQ concentration indicator ring: You can check the “IAQ Air Quality Grade” table according to the color of the ring displayed on the screen to understand the range of the concentration of various gases in the indoor environment.
  2. CO2 concentration calibration key: This function is suitable for products with CO2 detection indicators. This product adopts NDIR non-spectrographic infrared CO2 sensor. According to the characteristics of the sensor, this product has an automatic calibration function. When you start to use the detector, you can use your finger Trigger the “Network Distribution Key/CO2 Concentration Calibration Key” three times in a row. At this time, the screen turns off and then turns on again, the device enters a 24-hour calibration period, and then automatically enters an automatic calibration state every 15 days without operating the device. There should be natural ventilation conditions of more than half an hour in every fifteen-day cycle.
  3. WiFi distribution network: When you need to add products under the APP, first scan the QR code at the bottom of page 13 of the manual with your mobile phone, download the corresponding APP, and press and hold the network connection button for five seconds after powering on, the screen WiFi indicator flashes, enter The product is ready to be connected to the network; open the APP, click to enter the finalist page of adding a product, enter the WiFi account and password, and start the network configuration; wait for the APP page to display that the network configuration is successful, and the on-screen WiFi indicator stops flashing. The network configuration is successful, and the device addition is completed. For various gas indices detected by the air detector, the data of each period can be viewed through the gas concentration curve graph. The added air detector can be bound with fresh air fans and purification products (these two products need to be purchased separately) to realize intelligent control and ensure a clean indoor air environment.
  4. Battery indicator: depending on the product you choose, when the battery is about to run out, the icon in the middle of the detector on page 1 flashes; the Wi-Fi icon on the detector on page 2-3 flashes; the detector on page 4-6 flashes The battery icon on the left flashes to remind you that you need to charge the product in time.
  5. Screen display: The screen display of the machine has two modes: “always on” and “audio control”. You can switch according to your needs by operating the following steps: Press and hold the “network distribution key” when the device is off, and turn it on. , after the screen flickers once, release the “network distribution key”, and the voice control mode starts; when the device is off, press and hold the “network distribution key”, turn it on, release the “network distribution key” after the screen flickers twice, and the constant light mode starts.

Name of the hazardous substance in the product

FOBShanghai-HUA6-Air-Detector-fig-07

This form is made by accordance with the provisions of SJ/T11364.

  • 0: Indicates that the content of the hazardous substance in all homogeneous materials of the part is below the limit requirement specified in GB/T26572-2011.
  • X: Indicates that the content of the hazardous substance in at least one homogeneous material of the part exceeds the limit requirement specified in GB/T26572-2011.

Troubleshooting list

FOBShanghai-HUA6-Air-Detector-fig-08

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals