- Thank you for purchasing our UFO Highbay. Please read the below articles carefully to see how to use this product safely.
- Warning contents and attention contents related to product safety use, please be sure to follow it.
WARNING
Risk of Fire, Electrical Shock, Cuts or other Casualty Hazards- Installation
and maintenance of this product must be performed by a qualified electrician.
This product must be installed in accordance with the applicable installation
code by a person familiar with the construction and operation of the product
and hazards involved.
Risk of Fire and Electric Shock- Make certain power is OFF before
starting installation or attempting any maintenance. Disconnect power at fuse
or circuit breaker.
Risk of Fire- Minimum 90°C supply conductors.
Risk of Burn- Disconnect power and allow fixture to cool before handling or
servicing.
Risk of Personal Injury- Due to sharp edges, handle with care.
Failure to comply with these instructions may result in death, serious bodily
injury and property damage.
Attention
- This UFO High Bay within the input voltage range: 100-277v, 50/60Hz.
- If input voltage exceeds this range, it may cause the lamp failure. Please be sure to operate under correct input voltage.
- Ensure ambient operating temperature of -35 ℃~50 ℃.
- Using this UFO high bay in temperatures outside of this range will reduce the UFO high bay lifespan.
- Make sure to turn off power before starting the installation process.
- IP rating of IP65, can work under damp/wet locations.
- Please keep the UFO High Bay away from any corrosive substance. When you clean it, please use damp or dry cloth.
Wiring Diagram
Power adjustable
Model | RMS-HB-100 | RMS-HB-150 | RMS-HB-200 | RMS-HB-240 |
---|---|---|---|---|
LOW | 60W | 90W | 120W | 150W |
MID | 80W | 120W | 150W | 200W |
HIGH | 100W | 150W | 200W | 240W |
Product Dimension
Model | RMS-HB-100 | RMS-HB-150 | RMS-HB-200 | RMS-HB-240 |
---|---|---|---|---|
Φ1 | 132mm/5.19″ | 132mm/5.19″ | 132mm/5.19″ | 132mm/5.19″ |
Φ2 | 280mm/11.02″ | 280mm/11.02″ | 340mm/13.39″ | 340mm/13.39″ |
H | 115mm/4.53″ | 115mm/4.53″ | 116.5mm/4.59″ | 116.5mm/4.59″ |
Installation
-
Lock the hook. (Figure 1.)
-
Install and tighten the set screw. (Figure 2.)
-
Hang up the fixture. (Figure 3.)
-
Install the lock screw. (Figure 4.)