BlastGate 1711709665 SHUTR Gate Devices User Guide
- June 1, 2024
- BlastGate
Table of Contents
BlastGate 1711709665 SHUTR Gate Devices User Guide
Disclaimer statement
BlastGate.com BV has taken utmost care to provide complete, accurate and up- to- date information in this guide. However, Blastgate.com BV cannot guarantee that the information provided in this guide is complete, accurate and up to date.
BlastGate.com has the right to update the information in this guide without prior notice. BlastGate.com BV cannot be held liable for any damage, direct or indirect, as a result of incomplete or inaccurate information in this guide.
BlastGate.com provides guidelines in this guide for the usage of their products in relation to the CE/ATEX regulations. It is explicitly the responsibility of the user to install and use the products in accordance with the guidelines given. BlastGate.com BV cannot be held liable for any damage, direct or indirect, resulting from deviating from the guidelines in this guide.
Both this guide, a notice in the original packaging of the product and a warning sticker on the product warn the user of the fact that improper handling of the product may cause very serious personal injuries. BlastGate.com BV cannot be held responsible if a user, despite the clear instructions, handles the product in such a way that it results in injuries of any kind.
Product warranty
BlastGate.com BV provides 1 year warranty on its products. The terms and conditions regarding warranty claims can be found in the Warranty Clause document on www.blastgate.com
Trademarks
Is a registered trademark of BlastGate.com BV SHUTR
Connect™ is a trademark of BlastGate.com BV
Apple is a registered trademark of Apple Inc. Google is a registered trademark
of Google LLC.
Addendum
EC declaration of conformity
Safety and handling instructions
Please read these instructions carefully and follow the safety and handling directives. Not following the directives may cause serious injuries and/or damage to the gate. Warranty will be voided if the directives are not followed.
(!) Always unplug the gate from the power supply/adapter before handling the unit. Do not touch the stainless-steel slide while in motion. The stainless-steel slide inside the gate has a sharp edge that may cause serious injuries.
The edges are sharp, and the gates motor is powerful enough to cut off a finger!!!
- The gate is powered by a 24V DC adapter suitable for a mains supply of 110VAC to 240VAC 50-60Hz. Ensure that the supply voltage is not outside of this range otherwise the adapter may be
- Heavy electrical equipment with inadequate surge filtering may cause high voltage spikes on the mains. Avoid connecting the gate to the same mains outlet as it may damage the adapter and/or gate or cause malfunction of the electronics of the
- Avoid connecting wires to- or from the gate to be routed alongside mains supply cables for heavy electrical equipment.
- Operating temperature is -20°C to +45°C. Do not operate the gate outside of this temperature
- The electronics housing of the gate is dustproof to IP54 level. Do not place the unit in an environment that can cause water to ingress in the
- Before operating the gate, ensure that it is properly mounted to the ducting by using appropriate lock rings. Use ducting with 6mm wide flanges. Please follow the instructions for mounting the gate in this guide. Improper mounting of the gate may lead to load/strain on the connecting flanged tubes causing malfunction of the
CE/ATEX requirements
The SHUTR Gate complies with the CE/ATEX 114 guidelines.
Use the gate only in an ATEX defined zone if the zone’s definition is in
accordance with the gate’s specified zone definition.
The gate is tested and certified for the below given zones:
II 2/3D Ex h tc IIIB T85°C Db/Dc
Explanation:
II | Material group II for usage above ground |
---|---|
2/3D | Category 2D internal, category 3D external for non- electrical parts |
(slide), suitable for usage in zone 21internal and zone 22 external
3D| Category 3D for the electrical part, suitable for usage in zone 22
Ex h| Non-electrical parts comply with mode ofprotection “c”, constructive
safety
Ex tc| Electrical parts comply with mode of protection“tc”, protected by
housing
IIIB| Dust group IIIB, suitable for usage with non-conductive particles and
fibers
T85°C| Maximum surface temperature 85° Celsius
Db/Dc| Equipment Protection Level (EPL) Db internal, EPL Dc external for non-
electrical parts (shutter), suitable for usage in zone 21 internal and zone 22
external
Dc| EPL Dc for electrical part, suitable for usage in zone 22
Usage in the given zones is only allowed if the installation and usage comply with the following directives:
- The metal housing must be grounded at all times to avoid the buildup of static
- Always ground the metal ducting starting from the dust collector, from a single Avoid ground loops.
- Only use flexible hoses with a metal spiral inside. Grounding tabs on the gate are provided to connect the gate’s metal body to the metal spiral in a flexible We advise to use flexible hoses made of conductive material.
- Avoid dust from entering the electronics housing:
- Always mount the cable cover and split cable gland after installation, before
- Always use electrical cable with an outside diameter of 4mm (3.8 – 4.5mm) to allow for a dust tight installation in the cable gland and appropriate strain
- Follow the instructions in this guide for installing cables in the special cable gland to ensure a tight, dustproof
Gate features
The SHUTR Gate is a professional, electrically driven, wireless slide damper for usage in dust collection systems. The gate connects to industry standard (6mm) flanged ducting.
Features
- The SHUTR gate can be used standalone or as part of a wireless SHUTR Connect™ network:
- The SHUTR Connect™ network supports up to 60 SHUTR devices per Controller, multiple controllers per site
- The gate is fully plug & Only connect 24VDC.
- A wireless sensor or remote can remotely operate the gate and activate the dust collector
- No single point of failure, each component acts independent
- Easy installation, simple and straightforward pairing process
- SHUTR Connect app: Smart app for installation & advanced settings
Mechanical highlights
- Metal housing: no static discharge
- Flanged tubes: connect to industry standard ducting with 6mm flange
- Compact design: mount in any position as well as in corners
- Sealed shutter: fully airtight when closed, no pressure loss
- Durable design: easy maintenance & replaceable parts
Safety
- The gate is compliant with the strict European CE/ATEX 114 safety directives (explosive environments) for zone 21 and 22.
- Protected against a jammed slide, auto-recovery
- Minimum number of open gates to prevent a vacuum
- Encrypted network communications, no internet connection
- Configuration backup with the SHUTR Connect™ app
Standalone usage
Using the gate standalone means that the wireless capabilities are not used
in any way. The gate is powered by a 24V DC 1.5 Amps power supply.
Activating the gate (i.e., opening and closing) can be done in two ways:
- By using the rocker switch on the gate
- By connecting a remote switch or relay to the auxiliary port on the gate with a 2-wire cable. Set the rocker switch on the gate to the AUTO position if the aux port is used. Open/close the gate by respectively connecting/disconnecting the two wires.
Fully automatic usage: Connect to a SHUTR Connect™ network
A SHUTR Gate can be included in a wireless SHUTR Connect network. A SHUTR
Controller is needed to set up the network. The gate can be connected with a
simple and straightforward pairing process using the pairing button of with
the use of the SHUTR Connect app. Please refer to the Installation Guide of
the SHUTR Controller for details on the manual pairing process.
Once part of a SHUTR Connect network, the gate offers the following options:
- Several ways to activate the gate simultaneously:
- Manually, with the rocker switch on the gate
- With an external switch or relay connected to the aux port of the gate
- Using a wireless SHUTR Sensor
- Using a wireless SHUTR Remote Control
- One or more gates can be paired together to form a logical group (a “series”)
- Once a gate is activated, the controller with which it is paired, will automatically switch ON the dust collector (if the controller is configured to do so, which is the default setting)
- One or more gate(s) can default be set to OPEN when the dust collector is in-active to prevent a vacuum when the dust collector is switched ON
Pairing SHUTR devices (gate, sensor, remote) with a SHUTR controller can be done manually with the pairing button or with the SHUTR App available for Apple iOS and Google Android. With the SHUTR Connect app, besides pairing, one can set a large variety of parameters that define the behavior of each individual gate and the controller. Please refer to the SHUTR Controller Installation Guide for more details.
Hardware overview
Item | Description |
---|---|
1 | Motor housing |
2 | Maintenance opening |
3 | Rocker switch |
4 | LED indicator |
5 | Flanges metal tube |
6 | Stainless steel slide |
7 | Ground tab |
8 | Lead screw cover |
9 | Cable cover |
10 | Cable gland with grommet |
11 | Electronics housing |
Gate mounting instructions
The gate has been designed to connect to industry standard ducting with flat,
6mm flanges. Use lockrings that:
- accommodate both the thickness of the gate’s tubes (1mm) and the ducting thickness, and
- will galvanically connect the gate’s tubes and the ducting to ensure proper grounding without the need of additional grounding
The gate may be mounted in any position. There is no specific direction of the flow of air/dust. Mount the gate in such a way that the indicator LED is visible.
The antenna is located in the upper part of the electronics housing. If the gate is used as part of a SHUTR Connect network, make sure that the antenna is not obstructed by a thick wall, nearby ducting or other metal objects. It is best to have a line of sight between the electronics housing of the gate and the controller.
Support the connecting ducting: ****
- It must at all times be avoided that the gate carries the heavy load of a connecting tube or flexible tube. Too much load may impact the slide mechanism of the
- Always support the adjacent ducting within 50 cm on either side of the gate to prevent loads/strain on the gate itself!!!
Installing the gate
The SHUTR Gate has a special IP54 cable gland with a so-called split grommet. This grommet allows for cables-with-connector to be installed. This makes installations very easy and saves time.
To install cables in the cable gland, it is most efficient to stick to the following order:
-
Remove the cable cover by unscrewing the four bolts with a 3mm hex Allen key and keep the connector compartment open.
-
If you use the SHUTR Connect option you may want to do the pairing now (you can also do this once all components are installed).
Connect the gate to the 24VDC adapter.
Gather all gates, sensors, remotes and the controller on a table, power them up and do a quick manual pairing to set up the desired series or use the SHUTR Connect app -
Install the gate in your ducting
-
Disassemble the cable gland
Untighten the two top screws of the cable gland – but leave them in! No need to remove the body of the cable gland.- Unscrew the two screws on the front of the gland and remove the cap Slide out the split grommet
- A small blind stop is provided in case only one cable (the power supply cable) is installed. Otherwise, a maximum of two cables can be installed (aux cable for external switch or 5V USB-A for sensor power).
- Lead the 24V power supply cable (and optional aux cable) through the cable gland:
- Install the cable(s) in the grommet first and then lead the connectors through the opening of the cable cover
- Push the grommet back in – NOTE: once the grommet sits in the gland, the flat side of the grommet is at the front
- Leave only 4-5 cm of cable between the connector and the grommet
- Tighten the two front screws of the gland cap
- Lastly: tighten the two top screws of the gland body
- Close the Use a dummy plug if one cable entry is unused.
-
Connect the cable(s) to the gate
-
Mount the complete cable cover with cable gland back on the gates housing
Connections
-
Powering the gate
When planning for installation of the gates please take the following considerations into account:- A gate receives its power from a 24VDC/1.5Amps wall adapter. The supplied wall adapters come with a cable of 4 meters.
- It is not possible to run two gates from the same adapter
- Plan for sufficient wall outlets near the ducting system
- SHUTR sensors can both be powered from a 5V (USB-A) adapter or directly from a gate. The USB wall adapter, supplied with each sensor, has two USB- A ports so two sensors can be powered in order to minimize the number of required wall outlets as much as possible.
- Connecting the auxiliary port
The gate offers the ability to connect an external switch or relay (a potential free contact) to operate the gate. For this purpose, the gate is equipped with an auxiliary port – a 3.5mm mono jack plug receptacle – to connect the switch or relay.
It is advised to use a 3.5mm mono jack plug with screw terminals to connect the wires. The outside diameter of the 2-wire round cable can be 3.8 to 4.5mm in diameter to ensure proper sealing and strain relief in the cable gland of the gate.
Operations
-
Pairing/reset button
Stand-alone usage
If the gate is used standalone the pairing/reset button has no function except for the option to reset the gate to factory default after usage in a SHUTR Connect network.
SHUTR Connect network usage
For setting up a SHUTR Connect network, a SHUTR Controller is needed.
Pairing is the way SHUTR components are linked into series.
Use the pairing button to pair the gate to a series that may include other SHUTR devices such as sensor(s), remote(s), other gate(s) and the controller. Note that the rocker switch must be in the AUTO (A – middle) position to perform manual pairing using the pairing button.
Please refer to the SHUTR Controller Installation Guide for detailed information on pairing. -
Reset to default settings (erase all pairing information)
If you reset a component, or a component that is part of a series, this component
and all other components in that series will be reset. Once a component has been
reset, it is available again for pairing.
To reset a gate or sensor:- Set the rocker switch to OFF
- Press the button > 10 seconds
- After 10 seconds, the LED goes from RED to blinking YELLOW slowly
- Release the button, LED blinks YELLOW quickly
- Press the button AGAIN shortly within 5 seconds
- The component has now been reset and unpaired
- Not pressing the button again within 5 seconds will automatically cancel the reset
-
Reset to factory default
In addition to resetting to default settings, it is also possible to restore the originally factory installed firmware, perform the following steps to do so:- Unplug the gate from the power supply
- Keep the pairing/reset button pressed for >15 seconds while restoring power to the gate
- Release the button when the LED turns on again (WHITE or GREEN)
- The gate now runs the original factory firmware with default settings
Use this procedure only if a fatal crash causes the gate to not work anymore.
If you have updated the firmware before (using the SHUTR App), you will have to do so again in order to run the latest version of the SHUTR firmware.
Maintenance
To clear excess dust that is left behind in the gates housing if pushed
through by the slide, one can use compressed air. The gate has three openings
for this purpose. Use a compressed air nozzle to clear the housing from dust.
To clear dust from the seals inside the gate:
- Power up the gate first and OPEN the gate using the rocker switch
- Remove the power from the gate
- Unscrew the metal bottom cover of the gate (top cover carries the electronics housing)
- Take out the stack of silicone pressure seals and white POM seals and clear them of dust
(!) When re-installing the stack of seals, it is important to note the rounded sides of the white POM seals: they have to align in the middle as shown in the picture:
LED indicator color codes
Color | Blinking/steady | Status |
---|---|---|
WHITE | steady | Closed, communications oke |
GREEN | steady | Open, communications oke |
WHITE | blinking | Gate closing |
GREEN | blinking | Gate opening |
GREEN | Flashing 1/sec | Gate open, in gate inactive delay time, may close after |
delay
BLUE| blinking slowly| In pairing mode, not paired yet
BLUE| steady| In pairing mode, gate is paired
BLUE| Blinking shortly| Gate has requested pairing for its current series.
Confirm pairing request by pressing controller pairing button for 3 sec to
start pairing for this series.or: gate is in retry determining its size during
powerup
CYAN| blinking slowly| receiving new firmware from controller
CYAN| blinking fast| Installing new firmware
RED| Steady| Rocker switch CLOSED and button pressed (start of resetsequence)
RED| flashing 1x| Gate error (stuck/blocked or power <12V DC (normally 24V)
RED| flashing 2x| Component(s) missing in a series (communication error)
RED| flashing 3x| Not enough open gates to activate dust collector
(safeguardagainst a vacuum in the ducting)
RED| flashing 4x| Firmware upgrade failed
The SHUTR Connect app has the option to turn off the component LED when in- active in automatic mode.
Rocker switch – state table
When using a gate in combination with a sensor and/or an external switch the following state table gives an overview what effect the rocker switch and external switch have on the state of the gate:
Sensor Rocker Switch | Gate Rocker Switch | Gate action |
---|---|---|
X | OFF | Closes immediately |
X | ON | Opens immediately, activate dust collector when open |
ON | AUTO | Opens immediately, activate dust collector when open |
OFF | AUTO | Closes after gate delay time |
AUTO | AUTO | Opens when sensor detects current, activate dust collector when |
open
Remote Buttons| Gate Rocker Switch| Gate action
---|---|---
X| OFF| Closes immediately
X| ON| Opens immediately, activate dust collector when open
ON| AUTO| Opens immediately, activate dust collector when open
OFF| AUTO| Closes after gate delay time
Standalone Gate| Gate Rocker Switch| Gate action
---|---|---
| OFF| Closes immediately
| ON| Opens immediately, activate dust collector when open (if paired)
| AUTO| Closes 5 seconds after switching to AUTO
**External switch*| Gate Rocker Switch| Gate will**
---|---|---
| OFF| Closes immediately
| ON| Opens immediately, activate dust collector when open (ifpaired)
OFF| AUTO| Closes 5 seconds after switching to AUTO
ON| AUTO| Opens immediately, activate dust collector when open (if paired)
- = actually switches between ON and AUTO
Spare parts list
Part # | Description |
---|---|
1010185 XXX-050 | Gate XXX upper body |
1010186 XXX-050 | Gate XXX lower body |
1010172 XXX-050 | Gate XXX side assembly |
1010411 XXX-050 | Gate XXX POM ring |
1010455 XXX-020 | Gate XXX silicone pressure seal |
1010191 XXX-001 | Gate XXX slide assembly |
1010201173-001 | Gate 100 stepper motor |
1010201193-001 | Gate 120 stepper motor |
1010201233-001 | Gate 150/160 stepper motor |
1010110000-050 | Gate electronics housing PC |
1010120000-050 | Gate housing cover PC |
1010131000-050 | Gate cable cover assembly (gland/seal/cover) |
1010150000-050 | Gate motor housing |
1010140000-049 | Lead screw cover poly carbonate |
1010310000-003 | PCB gate rev 3 |
1010316000-001 | Rocker switch assembly |
1010327000-001 | 24V 1.5 Amp power supply EU |
Specifications
SHUT Gate model| Part number|
---|---|---
Gate 100| 1010000100-050
Gate 120| 1010000120-050
Gate 150| 1010000150-050
Gate 160| 1010000160-050
Di mensions (mm)| Gate 100| Gate 120| Gate 150| Gate 160
Inside_D| 100| 120| 150| 160
Total_L| 370| 410| 490| 490
Total_W| 168| 188| 228| 228
Total_H| 106| 106| 106| 106
Tube_L| 80| 80| 80| 80
Motor_W| 66| 66| 66| 66
Motor_H| 54| 54| 54| 54
| | | | | |
Power supply| 110/240VAC – 24V DC 1.5A (max.)Standby power consumption
2W
---|---
Radio signal| 2.412-2.462 GHz. FCC certified. Output power 19 dBm. Range
50-100 meters in open space. Built-in antenna.
Connections|
- 24V DC power jack 5.5/2.1mm
- USB-A 5V power supply for Sensor
- 3.5mm mono Jack plug for optional remote switch
- Tabs 6.3mm, for grounding wires (2x)
Operation|
- Rocker switch for operating mode (OPEN/CLOSE/AUTOMATIC)
- Pushbutton (PAIRING/RESET)Gate can be used standalone or as part of a SHUTR Connect™ networkClosing/opening time of the shutter ~ 2 sec.
Tube sizes| 100, 120, 150 and 160mm inside diameter. Flange width: 6mm.
Tube thickness: 1.0mm. Galvanized steel.
Chassis material| Galvanized steel 1.5mm
Shutter material| Stainless steel slide, 0.5 mm. POM/ silicone seals.
Electronics housing| Polycarbonate, IP54, UV resistance F1, operating
temperature -20° C to +40° C
Safety| CE / ATEX 114: II 2/3D Ex h tc IIIB T85°C Db/DcIndication of a
malfunctioning gate after 3 retries. ‘Default open’ gate(s) to prevent vacuum
(SHUTR Connect™ network)
Conformity| Complies with EN61326-1, EN61010-1, EN300328, EN301489-1,
EN301489-17, EN55011-A1-A11, EN61000- 3-2, EN61000-3-3, EN62368-1, EN62311,
EN63000
Warranty**| 1 year
Package includes| Gate unit, cable cover, 24VDC wall mount adapter EU
with 4 meter cable, Installation/User Guide.
(*) Specifications may change without prior notice.
(**) Please refer to the Warranty clause on www.blastgate.com
Diagnostics
Symptom | Possible cause and remedy |
---|
You want to start a manual pairing session on a gate or sensor but the LED
turns RED instead of WHITE| The rocker switch needs to be in the AUTO
position first. If it is in the CLOSE position, you start a reset sequence
instead, hencethe RED LED
The LED on the controller keeps flashing RED| Possible causes:
- A gate or sensor was unplugged (plug back in or, if the gate or sensor was unplugged intentionally, unplugthe controller from the mains and plug back in)
- A gate or sensor is unable to communicate
- The slide of a gate is stuck and went into fault mode
- There are not enough gates open to safely start the dust collector
Intermittent problems with communication|
- Check if the components are covered by metal or by a wall: this will negatively impact the transmission.
- Try to have a line of sight between the electronics housing of the gate and the controller as much as possible (flip the whole gate if its housing is “behind” its own metal body).
- For communication the SHUTR components all use Wifi frequency channel 1. This should not be a problem when there is an existing local Wifi network as they usually will switch to another channel automatically. If the problem persists, then try to manually set the Wifi channel of your local network to another channel then 1 on the router or access point.
- DECT wireless phone sets also work on the same frequency and maysometimes interfere with the Wifi signal
Unexpected reboot of a component|
- As the SHUTR components will most certainly be used in an industrial environment with heavy machines, it is possible that severe power spikes influence the electronics. Although filters have been installed, try to plug the wall mount adapter into a different power outlet
- Make sure that the metal housing of the gate is always grounded.
- Avoid ground loops, ground from a single point (preferably the dustcollector).
---|---
EC declaration of conformity
Manufacturer:
BlastGate.com B.V.
Botsholsedwarsweg 2A 3646AK Waverveen The Netherlands
Declares that the following line of products:
Product family: SHUTR
Model(s): Gate100, Gate120, Gate150, Gate160 and Sensor
Ful fill all relevant provisions of the Radio Equipment Directive (RED
directive), 2014/53/EU, according to the harmonized standards:
EN 300 328 (V2.2.2)| Wideband transmission systems; Data transmission
equipmentoperating in the 2,4 GHz band; Harmonised Standard for access to
radio spectrum
---|---
Fulfill all relevant provisions of the Electromagnetic Compatibility Directive 2014/30/EU, ccording to the harmonized standards:
EN 301 489-1(V2.2.3)| Electromagnetic compatibility and Radio spectrum Matters
(ERM);ElectroMagnetic Compatibility (EMC) standard for radio equipmentand
services; Part 1: Common technical requirements
---|---
EN 301 489-17(V2.2.1)| Electromagnetic compatibility and Radio spectrum
Matters (ERM);ElectroMagnetic Compatibility (EMC) standard for radio
equipment;Part 17: Specific conditions for Broadband Data Transmission Systems
EN 61326-1 (2013)| Electrical equipment for measurement, control and
laboratory use -EMC requirements – Part 1: General requirements
EN 55011 (2016)+ A1 (2017)+ A11 (2020)| Industrial, scientific and medical
equipment – Radio-frequencydisturbance characteristics – Limits and methods of
measurement
EN 61000-3-2(2014)| Electromagnetic compatibility (EMC) — Part 3-2: Limits —
Limits forharmonic current emissions (equipment input current <= 16 A
perphase)
EN 61000-3-3(2013)| Electromagnetic compatibility (EMC) — Part 3-3: Limits —
Limitationof voltage changes, voltage fluctuations and flicker in public low-
voltage supply systems, for equipment with rated current <= 16 Aper phase and
not subject to conditional connection
Full fills all relevant provisions of the Low voltage directive 2014/35/EU, according to the harmonized standards:
EN 62368-1 (2014)| Audio/video, information and communication
technologyequipment – Part 1: Safety requirements
---|---
EN 62311 (2008)| Assessment of electronic and electrical equipment related to
humanexposure restrictions for electromagnetic fields (0 Hz – 300 GHz)
Ful fills all relevant provisions of the EC RoHS directive 2011/65/EU, according to the harmonized standards:
EN IEC 63000
(2018)
Technical documentation for the assessment of electrical and electronic
products with respect to the restriction of hazardous substances
The signatory on behalf of the manufacturer:
The Netherlands| 20 November 2023|
Chris de Jongh, General Manager
---|---|---
Place of issue| Date of issue
BlastGate.com © 2023 All rights reserved. Document # 1010600102-001 2 of 2