The Digital Thermometer provides quick, highly accurate readings of your temperature. Please read the instructions thoroughly. They are edited to acquaint you with the features of your new thermometer so that you can enjoy its functions and years of dependable performance. If the thermometer is used by a child, the supervision of the adults is compulsory. This thermometer is manufactured according to the system of EN12470-3, ASTM, and complies with the requirements of IEC 60601-1, and IEC 60601-1-2.

PRODUCT DESCRIPTION

Boncare-GF-MT801-Oral-Thermometer-fig- \(1\)

SPECIFICATIONS

Range 32’C-42.9’C(90.0’F-109.9’F)(‘C/’F chosen by manufacturer)

Accuracy:

| ±0.1′ C,  35.5’C-42.0’C(±0.2’F,  95.9’F-107.6’F)

±0.2′ C under 35. C or over 42.0’C

±0.4’F under 95.9’F or over 107.6’F

At a Standard room temperature of 25′(( 77.0’F)

Display| Liquid crystal display,3 1/2 digits
Memory| For storing the last measured val ue
Battery| One 3.0V DC button battery(size CR1632)
Power consumption| 10 milliwatts in measurement mode
Batter y life| Approx 100 hours
Dimension| 12.8×3.0x 1.8cm( L xWx H)
Weight| Appro.20grams including battery
Using en v ironment| Temperature: S’C-40′((41’F-104’F) Relative humidity; 15%RH-85%RH
Storage and transportation

condition

| Temperature: -25′ C-55’C(-13’F- 131′ F)

Relative humidity; 15%RH-95%RH

Alarm(Beeper Mode)| Approx 10 seconds sound when peak temperature reached.

HOW TO USE

  1. Wipe or dip the probe with ethyl alcohol for disinfection.
  2. Push the On/Off button. The LCD will show 188.8: for 2 seconds and you will hear a beep simultaneously)’ The last tested temperature will be shown for about 2 seconds. After that Lo’C(Lo’F) sign shows(if the room temperature < 32’C (90.0’F) ).
  3. Position the probe in the mouth, rectum, armpit, etc.
  4. Once the temperature-talking is finished, the degree sign of ‘C(‘F)on the LCD will stop flashing, and you will hear buzzes for approx.10 seconds. The tested temperature is shown on the LCD. When the ‘C(‘F) stops flashing if the probe is still in the mouth, rectum, or armpit ,the temperature is possibly rising too, so after hearing the buzzes, you’d better take out it 1-2 minutes later. After the test, if the test temperature is <32’C or 90.0’F, the LCD shows Lo’C(Lo’F); if the tested temperature is >42.9’C or 109.9’F, the LCD shows Hi ‘C(Hi’F). After temperature-talking,if the tested temperature is <37.5’C or <99.S’F and, the buzzes are BiBi—BiBi—BiBi—BiBi and the screen shows green; if the tested temperature is 2:37.5’C and<37.8’C or 2:99.S’F and <100.0’F, the buzzes are BiBi–BiBi–BiBi–BiBi and the scieen shows yellow; if the tested temperature is 2:37.B’C or 100.0’F, the buzzes whose frequency are much higher are BiBi–BiBi–BiBi–BiBi and the screen shows red.
  5. The thermometer will automatically turn off in about 4 minutes for energy­saving. However, to prolong the battery life, it is suggested to press the On/Off button to turn the thermometer off once the test is finished.
  6. Please dispose exhausted battery and thermometer according to the relevant law.
  • Note: ln step 2 , if the room temperature is higher than 32’C(90.0’F), LCD will display the room temperature instead of Lo’C( or Lo’F)
  • Note: Use of the probe cover may result in a 0.1 ‘C(0.2’F)discrepancy from the actual temperature/.

ORAL USE

  • Put the probe into either position marked by ” √” as shown in the picture right-hand for about 1 minute. To insure accuracy, please keep your mouth closed for 5 minutes before taking your temperature. The normal temperature by this method is 35.7-37.3°C(96.3°F-99.2°F)

RECTAL USE

  • Lubricate the probe with petroleum jelly for easier insertion. Gently insert the probe about one centimeter(less than 1/2 inch.)Into THE Patient’s rectum, The normal temperature by this method is 36.5°C-37.6°C(97.7°F-99.7°F)

AXILLARY USE

  • From a medical viewpoint, this method will always provide inaccurate reading, Wipe the armpit with a dry towel. Place the probe into the armpit and keep the arm firmly against the body side for about 1.5 minutes, The normal temperature by this method is 35.2°C-37.0(95.4°F-98.6°F)

CLEANING AND DISINFECTION

  1. Clean the thermometer by wiping it with a dry cloth and sterilize the probe with ethyl alcohol
  2. Don’t let the thermometer contact any chemical thinner Not completely waterproof.
  3. Do not soak the LCD in water, Only the probe is waterproof.

PRECAUTION

  • Do not drop the thermometer, it is not shockproof
  • Do not bend the thermometer
  • Do not boil the probe
  • Do not store the thermometer in direct sunlight
  • Do not attempt to disassemble the thermometer except by replacing the battery
  • means direct volts d.c
  • means type BF

BATTERY REPLACEMENT

  1. When the “ “appears in the lower right corner of the LCD, the battery is exhausted and needs replacement.
  2. Use an object such as a coin to rotate the battery cover. Discard the exhausted battery out of the children.
  3. Place a new 3.0v D.C. button size battery type LR1632 or equivalent in the chamber with positive.
  4. Cover the battery cover.

LIMITED WARRANTY

  • The thermometer is guaranteed for one year from the date of purchase, if the thermometer does not function properly due to defective components or poor workmanship, we will repair or replace it free of charge.
  • All components are covered by this warranty excluding the battery.
  • The warranty does not cover damages to your thermometer due to improper handling.

FREQUENTLY ASKED QUESTIONS

What special feature does the Boncare GF-MT801 Oral Thermometer offer?

The Boncare GF-MT801 Oral Thermometer features a Fast Reading System, allowing for quick temperature measurements.

What type of display does the Boncare GF-MT801 Oral Thermometer have?

The Boncare GF-MT801 Oral Thermometer features a digital display, providing clear and easy-to-read temperature readings.

What are the product care instructions for the Boncare GF-MT801 Oral Thermometer?

The product care instructions for the Boncare GF-MT801 Oral Thermometer recommend wiping clean for maintenance.

How is the Boncare GF-MT801 Oral Thermometer powered?`

The Boncare GF-MT801 Oral Thermometer is powered by 1 Lithium Metal battery, ensuring convenient and reliable usage.

What are the package dimensions of the Boncare GF-MT801 Oral Thermometer?

The package dimensions of the Boncare GF-MT801 Oral Thermometer are 6.57 x 2.36 x 0.94 inches, making it compact and easy to store.

What is the weight of the Boncare GF-MT801 Oral Thermometer?

The Boncare GF-MT801 Oral Thermometer weighs 1.45 ounces, ensuring it is lightweight and easy to handle.

Who is the manufacturer of the Boncare GF-MT801 Oral Thermometer?

Hangzhou Universal Electronic Co., Ltd. is the manufacturer of the Boncare GF- MT801 Oral Thermometer, ensuring quality and reliability.

What is the price of the Boncare GF-MT801 Oral Thermometer?

The price of the Boncare GF-MT801 Oral Thermometer is $9.49, offering affordability without compromising functionality.

What is the warranty period for the Boncare GF-MT801 Oral Thermometer?

The Boncare GF-MT801 Oral Thermometer comes with a one-year warranty, providing assurance of quality and customer satisfaction.

What should I do if the Boncare GF-MT801 Oral Thermometer is not displaying any readings?

Firstly, ensure that the battery is correctly inserted and has sufficient charge. If the issue persists, try replacing the battery with a new one.

What steps should I take if the Boncare GF-MT801 Oral Thermometer display is malfunctioning?

Check for any visible damage to the display or connections. Try resetting the thermometer by removing and reinserting the battery.

How can I fix a damaged probe on the Boncare GF-MT801 Oral Thermometer?

If the probe is damaged, it may affect temperature readings. Contact Boncare customer support for guidance on how to replace the probe or inquire about warranty services.

What should I do if the Boncare GF-MT801 Oral Thermometer is not responding to button presses?

Ensure that the buttons are not stuck or obstructed. Try cleaning around the buttons with a soft cloth.

How can I troubleshoot connectivity issues with the Boncare GF-MT801 Oral Thermometer?

The Boncare GF-MT801 Oral Thermometer typically does not have connectivity features. However, if you're experiencing issues with temperature readings, ensure the thermometer is properly calibrated and positioned.

How can I troubleshoot a malfunctioning auto power-off feature on the Boncare GF-MT801 Oral Thermometer?

Check the settings to ensure the auto power-off feature is enabled. If it's enabled and still not functioning properly, try resetting the thermometer.

DOWNLOAD THE PDF LINK:Boncare GF-MT801 Oral Thermometer Operating Instructions

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals