IEI E73 Peach Display Industrial Computer and Components User Guide
- June 1, 2024
- IEI
Table of Contents
IEI E73 Peach Display Industrial Computer and Components
Specifications:
- Active Area Resolution: 3010 x 221 pixels
- Display Type: LCD
- Dimension (mm): 186.1 x 19.5 x 133.1
- Wireless Connector: Wi-Fi
- LED: Yes
- Buttons: Power, Bluetooth, Reset
- Battery: Included
- Display Colors: 4-color EPD
- Image Update Time: Every 24 hours in deep sleep mode
- Best Optic Temperature Range: N/A
- Storage Temperature: N/A
Product Usage Instructions:
Quick Start Guide:
For UART mode, download the full version user manual and ditherPrint PC app from the IEI Integration Corp. website.
Front Panel:
The front panel features a 4-color screen using Electrophoretic displays (EPD) technology, a status LED, and a QR code with the device’s unique number.
Rear Panel:
The rear panel includes a battery cover and three buttons with different functions:
- Power button: Short press to wake up from deep sleep, long press for various functions.
- Bluetooth button: Short press to switch to Wi-Fi mode.
- Reset button: Short press to reboot the device.
Bottom Panel:
The bottom panel has a USB Type-C connector for power source or PC connection. Refer to the ditherPrint user manual for image display setup.
FAQ
Q: How often does the image refresh on Peach-E73?
A: The image refreshes automatically every 24 hours when the device is in deep sleep mode to maintain image quality.
Q: How do I perform a factory reset on Peach-E73?
A: Long press the power button for 10 seconds to perform a factory reset. Note that all settings and data will revert to factory default.
Please download the full version user manual and ditherPrint PC app on the IEI Integration Corp. website.
Front Panel
The front panel of the Peach-E73 is a 4-color screen using Electrophoretic displays (EPD) technology. On the front panel, you can also find the status LED and the QR code that has the device’s Unique number.
The description of the Red LED indicator is listed below.
- Off: deep sleep / image display (print or slideshow)
- Solid Red: Standby
- Blink 3 times/sec: image or firmware transfer
NOTE:
The image will be refreshed every 24 hours automatically when the device is in
deep sleep mode. It is to maintain the image quality. There will be no refresh
if the image is full white.
Rear Panel
The rear panel contains a battery cover, and three buttons with different functions described below.
Buttons | Description |
---|
Power button
| Short press: wake up Peach-E73 from deep sleep mode*
Long press 3 sec.: stop slideshow in USB mode and go to deep sleep mode
Long press 10 sec.: factory reset
(Caution! All settings and data will revert to factory default)
Bluetooth button| Short press: switch to Wi-Fi mode
Reset button
| Short press: reboot Peach-E73 from any status (all settings and data will remain unchanged after reset)
- When provided with battery/USB power and set with no slideshow, the Peach E73 will go into deep sleep mode after pending for 15 sec.
Bottom Panel
The bottom panel of the Peach-E73 has a USB Type-C connector to connect with a power source or a PC for image display setup. Refer to the ditherPrint user manual for how to setup display image.
Dimensions
(millimeters)
The physical dimensions are shown below:
Specifications
The technical specifications for the Peach-E73 are listed below.
Peach-E73
Active Area| 7.3″
Resolution| 800 x 480
Display Type| Electrophoretic displays (EPD)
Dimension (mm)| 186.1 (L) x 133.1 (W) x 19.5 (D)
Wireless| IEEE 802.11b/g/n (2.4GHz Wi Fi)
Bluetooth 5 (LE)
Connector| USB Type C
LED| 2 colors (blue, red)
Buttons| Power, Bluetooth, Reset
Battery| 6 x AAA (not included in the product)
Display Colors| BWRY
Image Update Time| 18 sec (25ºC typ.)
Best Optic Temperature Range| 15ºC ~ 35ºC
Storage Temperature| -20ºC ~ 60ºC
Federal Communications Commission (FCC) Statement
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
You are cautioned that changes or modifications not expressly approved by the part responsible for compliance could void the user’s authority to operate the equipment.
FCC RF Radiation Exposure Statement:
This Transmitter must not be co-located or operating in conjunction with any
other antenna or transmitter.
This equipment complies with RF radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
a minimum distance of 20 cm between the radiator and your body.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- this device may not cause harmful interference and
- this device must accept any interference received, including interference that may cause undesired operation.
This device contains licence-exempt transmitter(s)/receiver(s) that comply
with Innovation, Science and Economic Development Canada’s licence-exempt
RSS(s). Operation is subject to the following two conditions:
This device may not cause interference, and This device must accept any
interference, including interference that may cause undesired operation of the
device.
Caution: Exposure to Radio Frequency Radiation
To comply with the Canadian RF exposure compliance requirements, this device
and its antenna must not be co-located or operating in conjunction with any
other antenna or transmitter.
CAUTION
- Image display requires and depends on a host system to provide images and manage them.
- The Peach-E73 must be installed and operated only by trained and qualified personnel. Maintenance, upgrades, or repairs may only be carried out by qualified personnel who are familiar with the associated dangers.
- The distance between the product and the human body is more than 20cm.
- Outside the European Union If you wish to dispose of used electrical and electronic products outside the European Union, please contact your local authority so as to comply with the correct disposal method.
- Within the European Union The device that produces less waste and is easier to recycle is classified as electronic device in terms of the European Directive 2012/19/EU (WEEE), and must not be disposed of as domestic garbage.
EU-wide legislation, as implemented in each Member State, requires that waste
electrical and electronic products carrying the mark (left) must be disposed
of separately from normal household waste. This includes monitors and
electrical accessories, such as signal cables or power cords. When you need to
dispose of your display products, please follow the guidance of your local
authority, or ask the shop where you purchased the product. The mark on
electrical and electronic products only applies to the current European Union
Member States.
Please follow the national guidelines for electrical and electronic product
disposal.