Sollatek AVS3P-0 Avs 3-Phase (Automatic Voltage Switcher) User Manual
- June 1, 2024
- Sollatek
Table of Contents
- Sollatek AVS3P-0 Avs 3-Phase (Automatic Voltage Switcher) User Manual
- SAFETY
- START-UP
- STANDARD OPERATION
- LIABILITY OF THE COMPANY
- WARRANTY
- RETURN OF GOODS
- TERMINAL COMPARTMENT
- MOUNTING
- AVS3P WIRING
- ELECTRICAL CONNECTIONS
- REPAIR/MAINTENANCE
- ENABLE ADDITIONAL PROTECTION
- SETTING CHANGE
- SPECIFICATION
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Sollatek AVS3P-0 Avs 3-Phase (Automatic Voltage Switcher) User Manual
AVS3P-0
AVS3P-0
APPLIANCE GUARD
3-PHASE AUTOMATIC VOLTAGE SWITCHER
SAFETY
All equipment designed and manufactured by Sollatek (UK) Ltd complies with the latest safety codes of practice. You should still follow all safety instructions and use caution when installing and operating electrical equipment.
To avoid the risk of a shock, DO NOT expose this equipment to rain, moisture, or liquid spillage. Before attempting to use it, ensure that the contact or solenoid does not exceed 16 amps. The equipment load must not exceed the contact or rating.
START-UP
STANDARD OPERATION
The AVS3P can also be set to protect against bad frequency (goes outside the operating range), phase imbalance (voltage deviation) and/or phase rotation (phases are swapped post-commissioning).
WAIT MODE
Wait Mode provides voltage monitoring and protection against power-back surges
and frequent power-ups by ensuring the mains power has fully stabilised before
automatically reconnecting it to your equipment after the set wait time has
elapsed.
The AVS3P will automatically adjust the wait time depending on the disconnection period to make the total OFF time equal to the set Wait Time. i.e. If Wait Time is 3 minutes and the disconnection is 2 minutes, then the wait time added is just 1 minute.
TIMESAVE™
If the AVS3P has been turned OFF for more than the set wait time, The AVS3P
will reconnect the supply to your loads in 10 seconds.
LIABILITY OF THE COMPANY
a) The company shall not be liable, either in contract or in tort for any
loss, injury or damage of whatsoever nature or to whomsoever or by whatsoever
cause arising directly or indirectly from any defect in the Goods (whether
latent or apparent) or as a result of the use of the Goods (save and except
any liability for death of or injury to any person resulting directly from the
negligence of the company) and the customer shall fully indemnify the company
against all claims and demands made upon the company by reason of any such
loss or injury or damage.
b) Without prejudice to the provisions of the immediately preceding sub clause
the company shall not in any event be liable for consequential or indirect
loss or damage howsoever arising under the contract or in relation to the
Goods.
c) The customer hereby acknowledges that the restrictions in this clause are
fair and reasonable in the circumstances.
WARRANTY
Unless otherwise agreed with the company or where the company has notified the
customer of special terms in respect of specified categories of goods the
company agrees at its option either to refund the cost of or repair or replace
goods proved to the company’s reasonable satisfaction to have failed under
proper storage and use within 24 months of delivery by reason of defects due
to faulty design (other than any design made, furnished or specified by the
customer) materials or workmanship provided that:
a) The customer shall have followed any instruction issued by the company in
relation to the goods and their storage.
b) In the case of defects which would have been apparent to the customer on
reasonable examination of the goods on delivery, ‘the’ customer shall notify
the company of the defects within 14 days of delivery.
c) In the case of any other defects the customer shall notify the company of
the defects in writing within 7 working days of the date when the defect
becomes apparent.
d) Where in discharge of its obligation under this clause the company agrees
that the customer may undertake any repair work on its behalf the cost of such
work shall be agreed in writing between the customer and the company before
the commencement of such work.
RETURN OF GOODS
a) Goods supplied in accordance with the customer’s orders cannot be accepted
for return without the prior written consent of the company and in accordance
with the company’s returns procedure.
b) The company reserves the right to levy a handling, administration or other
charge of such amount as it, in its absolute discretion, decides and may
deduct this from any credit allowed unless the reason for any return by the
customer is due to any fault or breach of these conditions on the part of the
company.
c) Returned goods must be sent carriage paid at the customer’s risk to the
company’s trading premises or to such other address as the company may direct.
d) The company will not allow credit in respect of returned goods not in fully
resaleable condition.
TERMINAL COMPARTMENT
Within the Terminal compartment, there are terminals for electrical
connections, unit mounting holes, and setting dials.
Isolate the power to the AVS3P before removing the terminal cover
MOUNTING
AVS3P WIRING
- Insert the wires through the gland nut and the glands.
- Connect the corresponding wires to the AVS3P terminals.
- Tighten the cable gland nuts and secure the terminal cover in place
ELECTRICAL CONNECTIONS
REPAIR/MAINTENANCE
The internal surge protection fuse may blow during a severe surge.
Only a qualified person should carry out repairs. Ensure power is isolated.
ENABLE ADDITIONAL PROTECTION
Phase rotation, voltage phase imbalance & frequency error, can be enabled via the switches inside the top compartment.
Ensure power is isolated before removing the top cover.
- Turn ON the required function(s) by sliding the switch from right to left.
- Replace and secure the top cover before powering ON.
Notes:
- WAIT LED indicates alarm level clearance (10s or user-selected DELAY timeout).
- If Delay is OFF, default 10-second delay is automatically activated.
- If LVD is OFF, only default 150V fast OFF is active.
- If HVD is OFF, no high-level voltage protection.
SETTING CHANGE
Note: Always match the set AVS3P limits to the equipment requirements.
SPECIFICATION
Read More About This Manual & Download PDF: