(STOP) Before you start A sump pump is an electrical device designed to operate in inherently wet environments.
ALWAYS USE EXTREME CAUTION when installing or maintaining this product!
Need Help: Call 1-877-326-3561 for assistance; Do Not Return to Store

SPECIFICATIONS

  • 1. System Connection
    • 1.2 Vertical Stand Models The 20 & 30 gallon tanks are equipped with plastic stand base and 1″ connection. The 40 gallon tanks are equipped with 11/4″ connection and steel support base.
  • 2. Location
    • 2.1 Proper Pressure Tank Location The pressure Tank should be installed as close as possible to the pressure switch. This will reduce the adverse effects of added friction loss and pressure switch bouncing, and the difference in elevation between Pressure Tank and switch.

WARNING EXPLOSION HAZARD When pressure tank has been in service and a change in the pressure is necessary due to a required change in the pressure switch setting, failure to follow instructions below can cause a rupture or explosion, possibly causing serious or fatal personal injury, and/ or property damage.

  • Do not adjust or add pressure if there has been a loss of air
  • Do not adjust the pre-charge pressure if there is visible exterior corrosion
  • Do not adjust the pre-charge pressure if there has been a reduction of the pump cycle time or the pre-charge pressure compared to its initial setting. This is because reduction in pump cycle time can result from loss of tank air pressure which in turn can mean there may be internal corrosion and any re-pressurization or additional pressure could result in rupture or explosion.
  • 3. Adjusting Pre-Charge Air Pressure, Prior to Installation Step 1. Remove protective air valve cap
    Step 2. Check pre-charge pressure (pressure should be + or -10% of the factory setting)
    Step 3. Release or add air necessary to make the pre-charge pressure 2 psig below the pressure switch pump cut-in setting. (Example, if you have an 20 Gal Tank with a pre-charge of 30 psig, and you have a pressure switch setting of 30/50 psig, adjust precharge of your tank from 30 psig to 28 psig.) Step 4. Replace protective air valve cap.

WARNING EXPLOSION HAZARD Failure to follow these instructions can cause a rupture or explosion possibly causing serious or fatal injury, flooding, and / or property damage.

  • 4. System Connection
    • 1. Locate the Pressure Tank in the final desired location
    • 2. Level as necessary
    • 3. To eliminate friction loss, do not reduce the pipe size from the pump to the Pressure Tank.
  • 5. Start Up
    • 5.1 Fine Tuning Procedures Many times the actual pressure switch will vary from the standard pressure range indicated. These variations could cause a momentary lag of water delivery, as the pressure switch is not “tuned to the tank recharge pressure”.

Installation

  1. Fill the system and Pressure Tank until pumps cut off.
  2. Open one or more fixture to drain the Pressure Tank.
  3. If there is a momentary pause in the water flow from the time the Pressure Tank is emptied and the pump starts, adjust pump cut in setting clockwise slightly.
  4. Close fixtures and refill Pressure Tank to pump cut off. Check time to fill.
  5. Open fixtures and see if pause in water is eliminated. If not, continue adjusting pressure switch.

CALIFORNIA PROPOSITION 65 WARNING! This product contains a chemical known by the State of California to cause cancer and to cause birth defects or other reproductive harm. (California Installer/ Contractor California law requires that this notice be given to consumer/end user of this product.) For more information: www.wilo-usa.com

Periodically Safety Inspection
The Pumping Piping System and Pressure Tank require safety
inspection every 6 months by a licensed professional.
Customer Self-Check Sheet

WATER SOURCE WST Series Pressurized Well Tanks Owner's Manual - Customer
Self-Check Sheet

APPLICATIONS
Designed for water storage, pressure boosting, and water transfer.

SPECIFICATIONS & PERFORMANCE

WATER SOURCE WST Series Pressurized Well Tanks Owner's Manual -
SPECIFICATIONS & PERFORMANCE

TROUBLE SHOOTING

WATER SOURCE WST Series Pressurized Well Tanks Owner's Manual - TROUBLE
SHOOTING WATER
SOURCE WST Series Pressurized Well Tanks Owner's Manual - TROUBLE
SHOOTING

ELECTRICAL PRECAUTIONS
WARNING Before servicing a pump, always shut off the main power breaker and then unplug the pump. Make sure you are not standing in water and are wearing insulated protective sole shoes, under flooded conditions. Contact your local electric company or a qualified licensed electrician for disconnecting electrical service prior to pump removal

WARRANTY

Retain Original Purchase Receipt for Warranty Eligibility
Limited Warranty
This warranty cannot be transferred – it is extended only to the original Purchaser or First User of the Product. By accepting and keeping this. Product you agree to all of the warranty terms and limitations of liability described below. IMPORTANT WARNING – READ CAREFULLY THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS MANUAL to avoid serious personal injury and/or property damage and to ensure safe use and proper care of this product. This water storage tank is designed for operation on cold well water systems limited to a maximum working pressure 150 PSI. A 125PSI safety valve must be installed.

  1. Who Receives Product Warranty Warranty is only valid for all purchasers of first users. The Warranty is non-transferable.
  2. What is covered by this Warranty Limited warrants to the purchaser or first user of the new Product that at the time of manufacture, the Product is free from defects in material and workmanship. Any warranty claim must be made within five (5) years unless another time period is set forth in the Manual, measured from the time the Product was purchased.
  3. What Manufactory Will Do If You Have a Covered Warranty Claim In the event of a breach of the foregoing warranty, manufactory will at its option replace or make repairs to correct any defect in material or workmanship or supply and ship either new or used replacement parts or products. MANUFACTORY will not accept any claims for labor or other costs.
  4. What This Warranty Does Not Cover – Exclusions and Limitations This Warranty does not cover any failure or problem unless it was caused by a defect in material or workmanship. In addition this Warranty shall not apply:
  • If the Product is not correctly installed, operated, repaired or maintained as described in the Manual provided with the Product; ” to any failure or malfunction resulting from abuse (including freezing); improper or negligent: handling, shipping (by anyone other than manufactory). Storage, use, operation, accident or alteration, lightning, flood, earthquake or any other environmental condition;
  • Any failure or problem resulting from the use of the Product for any purpose other than those specified in the accompanying Manual or alteration of any part of the product;
  • Warranty does not cover labor costs, shipping charges, service charges, delivery expenses. Administrative fees or any costs incurred in removing or reinstalling the Product;
  • Warranty does not cover any claims submitted to manufactory or authorized distributor or retailer more than 30 days after expiration of the applicable warranty time period described in this Warranty
  • Warranty also does not cover repair or replacement costs not authorized in advance.

Limitations of Remedies
THE REMEDIES CONTAINED IN THIS WARRANTY ARE THE PURCHASER’S OR FIRST USER’S EXCLUSIVE REMEDIES. IN NO CIRCUMSTANCES WILL MANUFACTORY BE LIABLE FOR MORE THAN, AND PURCHASER-FIRST USER’S REMEDIES SHALL NOT EXCEED, THE PRICE PAID FOR THE PRODUCT. IN NO CASE SHALL MANUFACTORY BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, WHETHER RESULTING FROM NON-DELIVERY OR FROM THE USE, MISUSE, OR INABILITY TO USE THE PRODUCT OR FROM DEFECTS IN THE PRODUCT OR FROM MANUFACTORY’S OWN NEGLIGENCE OR OTHER TORT. This exclusion applies regardless of whether such damages are sought for breach of warranty, breach of contract, negligence, strict liability, in tort or under any other legal theory. Such damages include, but are not limited to inconvenience. loss or damage to property, mold, loss of profits, loss of savings or revenue, loss of use of the Products or any associated equipment facilities, buildings or services, downtime, and the claims of third parties including customers.

WARNING
Pressures tanks must be installed by a qualified professional follow all local and national plumbing and electrical codes. Read and understand fully the instructions included here. Failure to follow these instructions may result in serious injury or death and or property damage and will void the product warranty. This tank is intended for use on potable water systems only and any other use may be dangerous and will void the warranty.

WARNING
This product’s performance and life span can be significantly and adversely impacted by aggressive water conditions. A water test should be done at regular intervals looking for corrosive water, acids, and other contaminates which must be treated immediately if present. The system piping must be properly grounded to earth and a dielectric union is recommended in the installation. The system piping must be properly grounded to earth and a dielectric union is recommended in the installation.

1899 Cottage Street, Ashland, Ohio 44805 Telephone: 1-877-326-3561 Fax: 1-877-326-1994 www.watersourceusa.com