HITACHI RCIM-(0.4-2.5)FSRE 4 Way Cassette Indoor Units System Installation Guide
- June 1, 2024
- Hitachi
Table of Contents
HITACHI RCIM-(0.4-2.5)FSRE 4 Way Cassette Indoor Units System
Product Information
Specifications:
- Model: RCIM-(0.4-2.5)FSRE
- Type: Indoor Units System Free 4-way cassette
- Revision: PMML0550 rev.2 – 08/2021
Product Usage Instructions
-
Installation:
Follow the installation manual provided with the product to correctly install the indoor units system free 4-way cassette. -
Operation:
Ensure the unit is connected to a power source and follow the operational instructions provided in the manual for optimal performance. -
Maintenance:
Regularly clean the unit and check for any blockages to ensure efficient operation. Refer to the maintenance section in the manual for detailed instructions.
Frequently Asked Questions (FAQ):
-
Q: How should I dispose of the product at the end of its life?
A: The product should not be mixed with general house waste. It should be retired according to local regulations in an environmentally correct way. Contact the corresponding authorities for more information. -
Q: What should I do if I encounter operational issues with the unit?
A: If you experience any operational issues, refer to the troubleshooting section in the manual for guidance. If problems persist, contact a professional installer for assistance
INSTALLATION & OPERATION MANUAL
-
INDOOR UNITS SYSTEM FREE
4-way cassette -
MODELS
RCIM-(0.4-2.5)FSRE
PMML0550 rev.2 – 08/2021
Specifications in this manual are subject to change without notice in order that Hitachi may bring the latest innovations to their customers. Whilst every effort is made to ensure that all specifications are correct, printing errors are beyond Hitachi’s control; Hitachi cannot be held responsible for these errors.
ATTENTION
- This product shall not be mixed with general house waste at the end of its life and it shall be retired according to the appropriated local or national regulations in a environmentally correct way.
- Due to the refrigerant, oil and other components contained in Air Conditioner, its dismantling must be done by a professional installer according to the applicable regulations.
- Contact to the corresponding authorities for more information.
WARNING
BURST HAZARD
Do not allow air or any gas mixture containing oxygen into refriger-ant cycle
(i.e. piping)
WARNING
This symbol displayed on the unit indicates that this appliance is
filled with R32, an odorless flammable refrigerant gas with low burning
velocity (A2L class pursuant to ISO 817). If the refrigerant is leaked, there
is a possibility of ignition if it enters in contact with
an external ignition source.
- CAUTION
- This symbol displayed on the unit indicates that this appliance shall be handled by authorized service personnel only, referring to the Installation Manual.
- CAUTION
- This symbol displayed on the unit indicates that there is relevant information included in the Operation Manual and/or Installation Manual.
- CAUTION
- For more information, see the Installation and Operation Manual.
RISK OF EXPLOSION
-
The compressor must be stopped before removing the refrigerant pipes.
-
All service valves must be fully closed after pumping down operation.
-
Make sure that unit installation and refrigerant piping installation comply with applicable legislation in each country. Also, in Europe, EN378 must be complied, as it is the applicable standard.
-
The supplementary information about the purchased products is supplied in a CD-ROM, which can be found bundled with the outdoor unit. In case that the CD-ROM is missing or it is not readable, please contact your Hitachi dealer or distributor.
-
PLEASE READ MANUALS AND THE FILES ON THE CD-ROM CAREFULLY BEFORE STARTING WORK ON THE INSTALLATION OF THE AIR CONDITIONING SYSTEM. Failure to observe
the instructions for installation, use and operation described in this documentation may result in operating failure including potentially serious faults, or even the destruction of the air conditioning system. -
Verify, in accordance with the manuals which appear in the outdoor and indoor units, that all the information required for the correct installation of the system is included. If this is not the case, contact your distributor.
Indoor Unit | Outdoor Unit |
---|---|
Installation and operation manual | Installation manual |
CD-ROM
Additional safety manual for R32 refrigerant air conditioner and heat pump
according to IEC 60335-2-40:2018
R32 Refrigerant circuit
The unit installation and refrigerant piping should comply with the relevant
local and national regulations for the designed refrigerant.
Due to R32 refrigerant and depending on final refrigerant charge amount, a
minimum floor area for installation must be considered.
- If total refrigerant charge amount <1.84kg, there are no additional minimum floor area requirements.
- If total refrigerant charge amount ≥1.84kg, there are additional minimum floor area requirements to be checked.
Minimum area requirements
In case of total refrigerant amount ≥1.84 kg, the unit should be installed,
operated and stored in a room with a floor area larger than the minimum
criteria. Use following graphic and table to determine these minimum criteria.
NOTE
- In case of not achieving the minimum floor area, contact with your dealer.
- For further information about refrigerant charge refer to the Outdoor
Unit Installation Manual.
Refrigerant Amount (kg) | Minimum Area |
---|---|
1.84 | 1.66 |
1.9 | 1.77 |
2.0 | 1.96 |
2.1 | 2.16 |
2.2 | 2.37 |
2.3 | 2.59 |
2.4 | 2.82 |
2.5 | 3.06 |
2.6 | 3.31 |
2.7 | 3.57 |
2.8 | 3.84 |
2.9 | 4.12 |
3.0 | 4.41 |
3.5 | 6.01 |
4.0 | 7.84 |
4.5 | 9.93 |
5.0 | 12.26 |
5.5 | 14.83 |
Minimum room area for installation
Total refrigerant amount in the system
- Amin: Minimum installation area of an Indoor unit for a given refrigerant charge mc (kg) and considering the installation height h0 (m2)
- h0: Installation height of the bottom side of the indoor unit + distance from the indoor unit bottom side to the lowest part for which a refrigerant leak may release to the indoor area
- mc: total system refrigerant charge that could be released to the indoor area in case of undetected refrigerant leak.
- LFL : Lower Flammability Limit for R32, 0,307 kg/m3 as established by
- EN 378-1 : 2016 and ISO 817
DANGER
Check to ensure that the number of below is within 0.44kg/m3. Otherwise it may cause danger situation if the refrigerant in the outdoor unit leaks into the room where this indoor unit is installed. (Total refrigerant quantity per one outdoor unit) (Volume of the room where this indoor unit is installed) For detail, refer to the Installation Manual for outdoor unit. ≤0.44kg/m3
- Make sure that the refrigerant leakage test should be performed. The refrigerant (Fluorocarbon R410A) for this unit is incombustible, non-toxic and odorless. However if the refrigerant is leaked and is contacted with fire, toxic gas will generate. Also because the fluorocarbon is heavier than air, the floor surface will be filled with it, which could cause suffocation.
- Use the specified non-flammable refrigerant (R410A) to the outdoor unit in the refrigerant cycle. Do not charge material other than R410A into the unit such as hydrocarbon refrigerants (propane or etc.), oxygen, flammable gases (acetylene, etc.) or poisonous gases when in-stalling, maintaining and moving. These flammables are extremely dangerous and may cause an explosion, a fire, and injury.
Original Version
The English version is the original one; other languages are translated
from English. Should any discrepancy occur between the English and the
translated versions, the English version shall prevail.
- DANGER – Hazards or unsafe practices which COULD result in severe personal injuries or death.
- CAUTION – Hazards or unsafe practices which COULD result in minor personal injury or product or property damage.
- NOTE – The text following this symbol contains information or instructions that may be of use or that require a more thorough explanation.