HITACHI RC-AGU1EA0G Functions Of Remote Controller Instruction Manual
- June 1, 2024
- Hitachi
Table of Contents
- HITACHI RC-AGU1EA0G Functions Of Remote Controller
- Names and Functions of Remote Controller
- Various Functions
- Powerful Operation
- LeaveHome Operation
- FrostWash Operation
- Precautions for Use
- Mold Guard Operation
- Adjusting the Airflow Direction
- Initialization of the Built-in airCloud Home Module
- My Mode(Programming)
- My Mode(Start or Stop of My Mode Operation)
- How to Exchange the Batteries in the Remote Controller
- Operation Mode Lock
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
HITACHI RC-AGU1EA0G Functions Of Remote Controller
Remote Controller manual
To obtain the best performance and ensure years of trouble-free use, please
read this instruction manual completely.
Names and Functions of Remote Controller
- This controls the operation function and timer setting of the room air conditioner. The range of control is about 7 meters. lf indoor lighting is controlled electronically, the range of control may be shorter.
Backlight function
- Backlight is to see the LCD readings in the dark.
- On Pressing any key, the LCD panel lights up for a period of approx. 10 seconds. After approx. 10 seconds the light automatically switches off.
- The function is independent of all other functions of the air conditioner.
- The backlight color is white.
Precautions for Use
- Do not put the remote controller under direct sunlight and high temperature.
- Do not drop it on the fl oor, and protect it from water.
- If you press the FUNCTION button during operation, the air conditioner may stop for about 3 minutes for protection before you can start it again.
Various Functions
Auto Restart Control
-
If there is a power failure, operation will be automatically restarted when the power is resumed with previous operation mode and airflow direction. (As the operation is not stopped by remote controller.)
-
If you intend not to continue the operation when the power is resumed, switch off the power supply. When you switch on the circuit breaker, the operation will be automatically restarted with previous operation mode and airflow direction.
Note:- If you do not require Auto Restart Control, please consult your sales agent.
- Auto Restart Control is not available when Timer or GoodSleep Timer is set.
Auto Mode
The device will automatically determine the mode of operation, Heat Mode or
Cool Mode depending on the current room temperature. The selected mode of
operation will change when the room temperature varies.
Heat Mode
- Use the device for heating when the outdoor temperature is under 21°C. When it is too warm (over 21°C), the heating function may not work to protect the device.
- In order to keep reliability of the device, please use this device above –15°C of the outdoor temperature.
- As the settings are stored in the memory of the remote controller, you only have to press the (On/Off) button next time.
- During Auto fan, the fan speed automatically changes as below:
- When the difference between room temperature and setting temperature is large, the fan starts to run at Super High speed.
- After room temperature reaches the preset temperature, the fan speed will be changed to a lower speed to obtain optimum room temperature conditions for natural healthy heating.
Defrosting
Defrosting will be performed about once an hour when frost forms on the
heat exchange of the outdoor unit, for 5~10 minutes each time. During
defrosting operation, the operation lamp blinks in cycle of 2 seconds on and 1
second off. The maximum time for defrosting is 20 minutes. (If the piping
length used is longer than usual, frost will likely to form.)
Dry Mode
Use the device for dehumidifying when the room temperature is over 16°C.
When it is under 15°C, the dehumidifying function will not work.
Dehumidifying Function
- When the room temperature is higher than the temperature setting: The device will dehumidify the room, reducing the room temperature to the preset level. When the room temperature is lower than the temperature setting: Dehumidifying will be performed at the temperature setting slightly lower than the current room temperature, regardless of the temperature setting.
- The preset room temperature may not be reached depending on the number of people present in the room or other room conditions.
Cool Mode
Use the device for cooling when the outdoor temperature is -10 to 46°C. If
humidity is very high (over 80%) indoors, some dew may form on the air outlet
grille of the indoor unit.
- As the settings are stored in memory in the remote controller, you only have to press the (On/Off) button next time.
- During Auto fan, the fan speed automatically changes as below:
- When the difference between room temperature and setting tem-perature is large, fan starts to run at Super High speed.
- After room temperature reaches the preset temperature, fan speed will be changed to lower speed to obtain optimum room temperature condition for natural healthy cooling.
Fan Mode
Timer Reservation
NOTE
- During setting timer, if you do not press any button for 3 seconds then it will come out of setting timer mode with preset time. On Timer icon ” ” or Off Timer icon ” ” will remain on LCD to indicate timer setting.
- During setting the timer, if you press the active button then it will come out immediately with the timer setting.
- Timer On and Timer Off can be set simultaneously.
- When both timers set simultaneously the arrow “right” mark will appear on LCD near ” ” or “ ” which will execute first.
- On Timer or Off Timer can be cancelled without long scrolling by pressing On Timer and Off Timer buttons together for 3 seconds.
Powerful Operation
- By pressing (Powerful) button during Auto, Heat, Dry, Cool, or Fan operation, the air conditioner performs at maximum power.
- During Powerful operation, cooler or warmer air will be blown out from the indoor units for Cooling or Heating operations respectively.
NOTE
- When Eco Operation, LeaveHome Operation, Silent Mode, GoodSleep Timer or My mode is selected, Powerful Operation will be cancelled.
- During Powerful operation, capacity of the air conditioner will not increase
- if the air conditioner is already running at maximum capacity.
- just before defrost operation (when the air conditioner is running in Heating operation).
LeaveHome Operation
Prevent the room temperature from falling too much when no one is at home. The initial setting temperature is 10.0°C and the temperature range can be set between 10.0°C and 16.0°C.
NOTE
- During LeaveHome operation, fan speed and horizontal air defl ector position cannot be changed.
FrostWash Operation
- The dust and dirt adhering to indoor heat exchanger which is the cause of the smell. They are washed away by freezing and thawing of the heat exchanger.
- FrostWash function can work when the outdoor temperature is 1°C to 43°C and Indoor humidity is 30% to 70%.
FrostWash(Manual Mode)
Precautions for Use
- Do not open windows or doors during FrostWash operation. Water will condense on the air deflector and drips down occasionally. This will wet your furniture.
- Do not open or remove the front panel during FrostWash operation. It may cause injury or malfunction.
- FrostWash operation does not wash away all dust and dirt.
- Hissing, fizzy or squeaking noise may generate during FrostWash operation.
- If the air conditioner is continuously running, FrostWash function is not effective.
- During FrostWash operation, if power is turned off and then power is restored, FrostWash function will not restart.
- After turning on the power, please wait a moment if you want to start FrostWash.
- If On Timer or Off Timer is set, there is a need to cancel those timer before operating FrostWash.
Mold Guard Operation
- After the cooling operation is stopped, the fan of the indoor unit is dried by heating or fan mode to suppress the generation of mold inside the indoor unit.
- Mold Guard Operation period is about 1 hour.
- It can’t remove mold or sterilize.
- Lamp on the indoor unit lights up during Mold Guard operation.
- If the air conditioner is operated in cooling or drying mode, including in auto mode, for more than 10 minutes and then put into off mode, the mold guard operation will start.
- If unit operation is stopped after heating operation, Mold Guard will not operate.
- Room temperature or humidity may rise
How to set and cancel Mold Guard
NOTE
- If unit operation is stopped after the heating operation, Mold Guard will not operate.
- If operation of Unit is stop by Off Timer or GoodSleep Timer, the Mold Guard will not operate.
- If On Timer is set and on time is within about 2 hours, the Mold Guard will not operate.
- Depending on the situation, Mold Guard will operate with Fan Mode.
- Room temperature or humidity may rise.
- When there is a window near indoor unit, the water might condense on the window during Mold Guard. If necessary, to cancel Mold Guard.
Eco Operation
Energy saving operation by changing set temperature and by limiting the
maximum power consumption value.
NOTE
- In case the power consumption is already low, Eco operation will not reduce the power consumption.
- By Pressing Powerful button, Mode button, LeaveHome button or My mode button, ECO operation will be cancelled.
- After auto restart, Eco Operation is cancelled and previous operation mode shall start.
Silent Mode
NOTE
- When Powerful operation is selected, Silent operation will be cancelled. Fan speed will return to the previous speed before Silent operation.
- After unit auto restart, Silent operation is cancelled. Fan speed will return to the previous speed before Silent operation.
- During any operations with silent fan speed if user presses the (Silent) button, the fan speed does not change.
- By Pressing Mode button or LeaveHome button or My mode button, the Silent operation is cancelled.
GoodSleep Timer Setting
By pressing the (GoodSleep) button during Auto, Heat, Dry, Cool or Fan operation, the unit shifts the room temperature and reduces the fan speed .
NOTE
- The indoor fan speed of air conditioner does not change even when fan speed button is pressed.
- If you set the GoodSleep timer when the Off timer or On Timer has been set earlier, the GoodSleep timer becomes effective instead of the Off timer or On Timer set earlier.
- On timer and Off timer can not be set if GoodSleep timer set earlier.
- GoodSleep timer will be cancelled if selected My Mode or LeaveHome Operation.
Adjusting the Airflow Direction
Adjust the airfl ow upward and downward. According to operation, the horizontal air defl ector is automatically set to the proper angle suitable for each operation.The defl vector can be swings up and down and also set to the desired angle using the “ (Up/Down )” button. Press the (Up/Down )” button . The deflector will start to swing up and down. “ ” is display on LCD screen. Press the (Up/Down) ” button again. The deflector(s) will stop in the current position. “ ” is disappear on LCD screen.
- If the “ (Up/Down )” button is pressed once, the horizontal air defl ector swings up and down.If the button is pressed again, the defl ector stops in its current position. Several seconds (about 6 seconds) may be required befo re the defl ector starts to move.
When the operation is stopped, the horizontal air defl vector moves and stops at the position where the air outlet closes.
CAUTION
- In “Cooling” operation, do not keep the horizontal air defl vector swinging for a long time. Some dew may form on the horizontal air defl ector and some dew may drop from it.
Adjust the airfl ow to left and right. Hold the vertical air deflector as shown on the right and adjust the airfl ow to left and right.
Initialization of the Built-in airCloud Home Module
- You can reset the internal settings (restore the factory settings) by remote controller.
How to restore factory setting
Please make this setting with the remote control in off mode.
My Mode(Programming)
- Use this mode for personalized comfortable settings. The My Mode can be set by using the remote controller.
- Up to 3 programs can be set.
Programming of My Mode
Programming of My Mode
Note
- If operation of remote controller will not be done for 10 seconds during My Mode programming, the remote controller will come out from My Mode programming without registering of My Mode Programming. without registering of My Mode Programming, My Mode selection will remain with all previously selections and previous values.
- If My Mode button is kept pressing for 5 seconds during My Mode Programming, the remote controller will come out from My Mode Programming. without registering of My Mode Programming, My Mode selection will remain with all previously selections and previous values.
- If the battery is replaced or the Reset (Reset) button is pressed, My Mode Programming on the remote controller will be reset to default settings. if new settings are required, do My Mode Programming again.
- When Operation Mode Lock is set, selectable mode during My Mode will be limited.
My Mode(Start or Stop of My Mode Operation)
Start of My Mode Operation
Stop of My Mode Operation
NOTE
- My Mode operation can be cancelled by pressing (Mode) button or (LeaveHome) button.
- If My Mode Operation is started without programming of My Mode yet, room air conditioner starts with default setting of My Mode.
- If On Timer or Off Timer set by My Mode has elapsed, pressing My Mode (My Mode) button again to restart the Timer operation.
- FrostWash (Manual Mode) will not activate during My Mode.
- Up/Down button is active during My mode for adjusting horizontal air deflector.
How to Exchange the Batteries in the Remote Controller
- Remove the cover as shown in the figure and take out the old batteries.
- Install the new batteries. The direction of the batteries should match the marks in the case.
CAUTION
- Do not use new and old batteries, or different kinds of batteries together.
- Take out the batteries when you do not use the remote controller for 2 or 3 months.
NOTE
Change the batteries when remote controller LCD display restarts on
pressing of any key and there is no response from air conditioner.
Operation Mode Lock
The remote controller can be set to fix the Heat Mode (including Fan Mode), Cool Mode and Dry Mode (including Fan Mode) operations.
NOTE
- Operation Mode Lock function will not activate if Timer reservations or My Mode is activated. Timer reservations shall be deactivated first. Then, the Operation Mode Lock function can be activated.
- Operation Mode Lock can be kept even if (Reset) button is pressed.
- Operation Mode Lock will not be set if FrostWash(Manual Mode) is in progress.
- LeaveHome button is disable during lock Cool mode and Dry Mode operation.
How to Reset Filter Sign on the Indoor Unit
Filter Sign on the indoor unit will show with ” ” lamp by blinking with 1 second on and 4 seconds off. Because cleaning of Air filter has not been done for a long time. Clean the Air filter. Press Filter Button at Off Mode pointing the remote controller towards the indoor unit to reset Filter Sign.
“ ” symbol will be visible on LCD screen for about 3 seconds and FilterC Sign on the indoor unit will turn off.
NOTE
- Filter Button is active in OFF mode only.
Reset Function ( For Hardware Reset)
During Battery replacement or any unlikely event, if the display does not change on Press of key or any unwanted garbage display comes, Press Reset button to reset your remote controller hardware. In order to reset remote controller hardware , PressandreleaseReset button, the display will be as shown for 2 seconds then it will change to default mode screen.
NOTE
- Use some pointed item like pen to press the reset key.
- Once the remote controller is reset, all setting will reset except some special function activated by User
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>