INTERMATIC EC200 In-Wall CountdownTimer with Hold Feature Instruction Manual

June 3, 2024
Intermatic

INTERMATIC EC200 In-Wall CountdownTimer with Hold Feature

INTERMATIC-EC200-In-Wall-CountdownTimer-with-Hold-Feature-
PRODUCT

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS

  • Disconnect power at the circuit breaker(s) or disconnect switch(es) before installing or servicing.
  • Installation and/or wiring must be in accordance with national and local electrical code requirements.
  • Connect to copper conductors only.
  • Do not use timer to control devices that could have dangerous consequences due to inaccurate timing, such as sun lamps, sauna, heaters, crock pots, etc.

Ratings:

  • 15 A General Purpose
  • 15 A Resistive
  • 1000 W Tungsten
  • 1/4 HP Motor
  • 500 VA Electronic Ballast
  • 1000 VA Ballast
  • 120 Vac 60Hz
  • Leads: Black-Line, White-Neutral, Red-Load, Green-Ground

Installation

  1.  Disconnect power to the circuit.
  2. Remove wall plate and disconnect light switch.
  3. Make sure both “hot” and neutral wires are present in the junction box. (See Fig. 1.)
  4. NOTE: If both wires are not present, additional wiring will be necessary before installation can be completed. Remove insulation from each conductor and make sure ends of wire are straight. Connect red timer wire to fixture wire and secure with a wire connector. (See Fig. 2)
  5. Connect black timer wire to the “hot” wire in junction box and secure with a wire connector.
  6.  Cut white wire in junction box (or open splice) and strip 7/16 ” of insulation on both wires.
  7. Connect white timer wire to white wires in junction box and secure with wire connector. (See Fig. 2)
  8. Connect the green wire from new timer to the existing ground in box.
  9.  Verify all wire connections are secure.
  10.  Place timer and all wires inside junction box.
  11.  Install the timer and secure with supplied mounting screws.
  12.  Reconnect electrical power.

Operation

Timer Mode
Press and release timer button repeatedly to select the desired time setting or to select OFF. The illuminated LED indicates which time setting is selected and the connected load is turned ON. After the selected time interval counts down, the LED and the connected load turns OFF.

Hold Mode (Continuous Operation)
To turn timer ON for extended periods of time, press and hold the timer button for more than 2 seconds. Timer enters HOLD mode, HOLD LED turns on, and the connected load is turned ON. To exit HOLD mode press and release the timer button. LED goes off and the connected load turns OFF.

In-Wall CountdownTimer with Hold Feature

Warranty service is available by either (a) returning the product to the dealer from whom the unit was purchased or (b) completing a warranty claim online at www.intermatic.com. This warranty is made by: Intermatic Incorporated, 1950 Innovation Way, Suite 300, Libertyville, IL 60048. For additional product or warranty information go to: http://www.Intermatic.com or call 815-675-7000.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Intermatic User Manuals

Related Manuals