SAFETY RULES FOR THE ProSensor X2100 & M210
WARNING: Read all instructions before use. Failure to follow safety
instructions may result in electric shock, fire, and/or serious injury and
death.
SAVE THESE INSTRUCTIONS
WARNING: It is possible that there may be wood, metal, wiring, or other
objects behind the surface that are not detected. The stud finder may also
detect pipes, wires, or other objects. The stud finder is designed to detect
any change in density but does not identify what type of object it detects.
The illuminated LEDs may indicate the location of many different features
including, but not limited to, studs, beams, water pipes, gas pipes, wires, an
inconsistency in the surface material or paint, etc.
WARNING: TURN OFF all gas, water, and electric power before using any
drilling or penetrating the wall.
FAILURE TO TAKE THESE AND OTHER NECESSARY PRECAUTIONS COULD RESULT IN ELECTRIC
SHOCK, FIRE, AND/OR SERIOUS INJURY AND DEATH.
Temperature
If the stud finder is subject to a significant temperature change, allow it to
adjust to the ambient temperature before using. The entire area of the sensor
board should be at a similar temperature for best operation.
ENVIRONMENTAL CONDITIONS
Franklin Sensors stud finders will work best when maintained in the following
environmental conditions:
Storage
Temperature| (0°F to 120°F)
(-18°C to 50°C)
---|---
Storage Humidity| 0% to 90%
Relative humidity (non-condensing)
Operating
Temperature| (32°F to 110°F)
(0°C to 43°C)
---|---
Operating Humidity| 0% to 90%
Relative humidity (non-condensing)
OPERATING INSTRUCTIONS
TO OPERATE:
- Hold the stud finder by the handle. Do not touch the detector outside of the handle area while scanning.
- With the button depressed, you may immediately begin scanning the wall. You may press the button on or off wall. No calibration is required. As you scan, LED lights will illuminate to display the location of any hidden object.
- LEDs track the center and edges of studs simultaneously. In certain models, the center LED will turn green once the precise center of the stud has been reached.
HEAVY TEXTURE OR IRREGULARITIES:
Franklin Sensors stud finders identify the location of studs by identifying
differences in the density of the material in the wall. Consequently, areas of
heavy texture and/or irregularities in the wall, can also cause the LEDs to
illuminate. When this happens, you know your stud finder is doing its job. To
help determine if you have actually found a stud, continue to press and hold
the button and then scan the wall up and down. The LED lights will normally
remain constant on a stud, whereas the LEDs will only display sporadically on
a wall’s irregularity.
FINDING PIPES AND WIRES:
Franklin Sensors stud finders identify the location of studs by identify
differences in the density of the material in the wall. Consequently, wires or
pipes that are near the surface, can also cause the LEDs to illuminate. When
this happens, you know your stud finder is doing its job. To help determine if
you have found a stud, continue to press and hold the button and then scan the
wall up and down. The LED lights will normally remain constant on a stud,
whereas wires may only make contact in a small area and pipes may have elbows
and branch off which may cause LEDs to only illuminate sporadically.
ALWAYS TAKE THE NECESSARY SAFETY PRECAUTIONS AND TURN OFF all gas, water and
electric power before penetrating the wall.
LATH AND PLASTER
The ProSensor X2100 & M210 can see up to 1.7 inches and thus can see through
most lath and plaster walls. When irregularities in plaster thickness and
variations in construction materials exceed this depth, detection is not
guaranteed. Also, the stud finder may not be able to detect if the plaster
uses metal mesh reinforcement.
TILE, FLOORING, ROOFING AND EXTERIORS
Due to the variability in thickness and density in tile, roofing and exterior
materials, detection is not guaranteed.
FIRE BLOCK OR HORIZONTAL STUDS
When searching for fire blocks or horizontal studs, turn the stud finder
vertically and scan up and down the wall so the sensors can find the density
differences in the wall.
BATTERIES
The ProSensor X2100 & M210 use 2 AA batteries. Do not mix old and new
batteries. Do not mix alkaline, standard or rechargeable batteries.
REPLACING THE BATTERIES
- Remove the battery cover by pushing on the recessed triangle on the battery cover. Slide the cover to the right and lift.
- Replace with 2 new AA batteries.
- Close the unit by replacing the battery cover and sliding it to the left until it snaps into place.
When the battery voltage is low, the second LED from the right will flash. Replace with 2 new batteries.
CONVENIENT PENCIL CADDY
The ProSensor X2100 & M210 has a convenient pencil caddy. The pencil can be
removed easily by gently pressing on the opening with your thumb or finger and
sliding the pencil out.
- LED Lights
- Ergonomic Handle
- “On” Button
- Battery Cover
- Detector Housing
- Sensor Board
- Bubble Level
- Pencil Caddy
- Live Wire Meter
LIVE WIRE METER
The ProSensor Live Electrical Warning™ works continually while the button is
depressed. When a live electrical wire is detected, the yellow LEDs on the
Live Wire Meter, patent pending, will illuminate in sequence as the electrical
strength increases.
Live wires are most commonly found in two configurations.
- The wire runs vertically next to the stud, or 2) A hole is drilled through the stud and the wire is threaded through the stud.
- For vertically running wires, scan the stud finder side to side.
- For horizontally running wires, run the stud finder up and down the stud.
- In both cases, the Live Wire Meter will increase in strength as you approach the live wire.
The ProSensor uses Active Learning Technology™. To best detect the presence of
live electrical wires, slowly scan in both directions, passing over the same
location multiple times, for a more accurate reading.
NOTE: The ProSensor Live Electrical Warning™ is optimized for finding
live wires on or near studs.
WARNING: This product may not detect all live wires or all hidden
objects. Always turn off the electrical power, gas and water supplies before
penetrating a surface.
TROUBLESHOOTING
CONDITION | PROBABLE CAUSE | SOLUTION |
---|---|---|
No LED lights come on. | Weak or Rechargeable Batteries. | Replace with 2 new AA |
batteries. Do not mix old and new batteries.
Stud finder only works momentarily.| The”on” button isn’t being held down.|
Hold the”on” button down until you have completed your scan.
Difficulty starting a scan near doors and windows.| Solid headers and triple
studs are often present around doors and windows. The ProSensor indicates the
change in density. If all the sensors sense the same density, the LEDs will
not illuminate.| Begin the scan away from the window or door, then move the
stud finder to the area around the window or door. For best results, keep stud
finder 3″/7cm away from wood trim, outlets, switches, etc.
The LED lights sometimes seem to light up sporadically or inconsistently.|
Operator is holding the unit near the base rather than on the handle.| Only
hold the unit by the handle with a finger continually pressing the button.
Inconsistent readings.| Franklin Sensors stud finders find any change in
density. The sensor’s job is to identify any changes in density. In the case
of heavy texture, pipes and wires close to the surface of the wall or other
irregularities in the wall, the LEDs may illuminate. When this happens, you
know your stud finder is doing its job!| When you get a reading, continue to
press and hold the button and then scan the wall up and down. The LED lights
will remain constant on a stud, while irregularities will only display
temporarily.
SENSING THROUGH DIFFERENT MATERIALS:
Moisture
The scanned surface should be clean and dry. Paint and wallpaper need to be
completely dry before scanning for studs. It may take up to 2 weeks for
wallpaper to dry enough to detect studs.
Foil-Backed Insulation
Although not common, foil-backed insulation can cause inconsistent readings
with all electronic stud finders, including the ProSensor.
Metallic Content in Wallpaper
Wallpaper with metallic content can block the detector’s signals.
STICKERS / DECALS
Do not place decals or stickers, especially those containing metal, on the
sensor board, or on the stud finder in any place.
DISASSEMBLY / TEFLON PADS
Do not disassemble the stud finder or remove the teflon pads on the bottom.
The stud finder will not operate correctly without the teflon pads properly in
place.
DISPOSAL
Stud finders and packaging should be sorted for recycling.
FCC PART 15 CLASS B REGISTRATION
WARNING
This device complies with Part 15 of FCC rules. Operation is subject to the
following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this device”
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
LIMITED LIFETIME WARRANTY
Franklin Sensors Inc. offers a Limited Lifetime Warranty on all its products.
The products are warranted to be free from defects in materials and
workmanship for the life of the product. If a defect is found, at Franklin
Sensors’ discretion, Franklin Sensors will either repair or replace the unit
with an equivalent product. The function of the products is not guaranteed.
For example, for stud finders it is possible that there may be wood, metal,
wiring, or other objects behind the surface that are not detected. It is also
possible that stud finders may detect pipes, wires, or other objects that the
user may not want to detect. The stud finders do not identify what type of
object they detect. Illuminated LEDs may indicate the location of many
different features including, but not limited to, studs, beams, water pipes,
gas pipes, wires, an inconsistency in the surface material or paint, etc. This
warranty does not cover incidental or consequential damage such as physical
injuries, property damage, loss of time, loss of use of the product,
inconveniences, or accommodations resulting from failure of the products.
Franklin Sensors shall not be liable for any special, indirect, incidental, or
consequential damages or losses, whether arising from breach of warranty or
based on contract, tort, reliance or any other theory. Since some countries or
states do not allow limitation of the term of an implied warranty, or
exclusion or limitation of incidental or consequential damages, the
limitations and exclusions of this warranty may not apply to every buyer.
In the event of a product defect, please return the product postage paid with
proof of purchase to:
Franklin Sensors Inc.
Attn: Returns Department
6675 N Pollard Ln
Meridian, ID 83646 208-918-2403
returns@franklinsensors.com
Hours of Operation: Monday-Friday,
8 AM to 5 PM,
Mountain Time Zone
US Patents 8,476,912 8,593,163 8,669,772
8,736,283 8,791,708 8,836,347 8,884,633 10,895,657
US and Foreign Patents Pending.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>