Product Information

Specifications:

  • Model: AH12E15D5B
  • Heater Type: Electric Heater
  • Voltage: 230/208 Volt
  • Heater Watts: 5,000 / 4,100
  • Heater BTU: 15,000 / 12,000
  • Heater Amps: 22.3 / 20.1
  • Min Circuit: 30 Amps
  • Recommended Protective Device: 30 amp time-delay fuse or breaker

Installation Information

Wall Case Dimensions:

  • A: 30 inches
  • C: 70 inches

Wall Opening Dimensions: Add 1/4 inch to A and C dimensions for all cut- outs. RAB80 16-1/4 Min. H x 42-1/4 Min.W

Features and Benefits:
This electric heater unit provides efficient heating with the following features and benefits:

  • High Heating Capacity: Heater Watts of 5,000 / 4,100 and Heater BTU of 15,000 / 12,000
  • Flexible Voltage Options: Operates at both 230V and 208V
  • Easy Installation: Line cord connected units for convenient setup
  • Safe Operation: Recommended protective device for circuit safety

Product Usage Instructions

Installation Steps:

  1. Ensure the wall case dimensions meet the specified requirements.
  2. Cut out the wall opening dimensions with the additional 1/4 inch allowance.
  3. Mount the electric heater securely in the wall opening.
  4. Connect the unit to a 230V or 208V power source as per the voltage requirement.
  5. Install the recommended protective device (30 amp time-delay fuse or breaker) for circuit protection.

Operation Instructions:

  1. Set the desired temperature on the electric heater unit.
  2. Turn on the unit using the designated power switch.
  3. Monitor the heating performance and adjust settings as needed.
  4. Ensure proper ventilation around the unit for optimal heat distribution.

Frequently Asked Questions (FAQ)

Q: What is the recommended protective device for the electric heater?
A: The recommended protective device is a 30 amp time-delay fuse or breaker for circuit safety.

Q: What are the voltage options supported by the electric heater?
A: The electric heater operates at both 230V and 208V for flexible installation.

AH12E15D5B
Hotpoint® PTAC with Electric Heat 30 amps, 230/208 Volt

DIMENSIONS AND INSTALLATION

DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)

ELECTRICAL WIRING

  • All wiring, including installation of receptacle, must be made in accordance with local electrical codes and regulations.
    NOTE: Aluminum wiring may pose special problems – consult a qualified electrician.

GRILLE OPTIONS

  • Stamped Aluminum Grille – RAG70

ELECTRICAL CONNECTION

  • 230/208 volt units must be plugged into a receptacle. Installation must comply with local electrical codes and regulations.
  • Power cord is permanently attached on all Hotpoint chassis.

WALL CASE DIMENSIONS

RAB80 WALL SLEEVE
Heavy-gauge galvanized steel, with insulation, for quick self-assembly.
A – 42”, B – 13-3/4”, C – 16”

MAXIMUM CORD EXTENSION

WALL OPENING DIMENSIONS
Add 1/4” to A and C dimensions for all cut-outs.
RAB80 16-1/4” Min. H x 42-1/4” Min. W

Hotpoint-AH12E15D5B-Electric-Heater-1

AH12 ELECTRIC HEATER

230/208 VOLT LINE CORD CONNECTED UNITS
Heater Watts 5,000 / 4,100
Heater BTU 15,000 / 12,000
Heater Amps 22.3 / 20.1
Min Circuit 30
Recommended protective Device 30 amp time-delay fuse or breaker

FEATURE AND BENEFITS

  • 14,500 / 14,300 cooling BTU
  • 10.3 / 10.4 EER
  • R32 Refrigerant – Environmental friendly, low GWP (Global Warming Potential)
  • 3-Speed Fan – Give guests control over their comfort with three fan speeds to choose from
  • 4-Temperature Limiting Options – Easily select one of four temperature ranges for peak efficiency and total customer comfort
  • Intuitive Display – Allow guests to easily customize their preferred settings and reduce maintenance calls with an easy-to-use control panel
  • Power Cord (LCDI) Included – Hotpoint PTACs come with everything needed for a quick and easy installation
  • Automatic Emergency Heat – Keep guests comfortable with a heating option that uses electric resistance heat in heat pump mode
  • Freeze and Frost Protection – Automatic freeze and indoor frost control keep units operating in peak condition
  • Auto Power Recovery – In case of power failures, units automatically resume their operation when power restores, reducing maintenance calls
  • Self Diagnostics – Quickly and easily identify service needs with a nine-point diagnostic code system
  • Backed by an Industry Leader – With a long history of creating durable products at an affordable price, Hotpoint is your trusted PTAC brand

PRELIMINARY SPECIFICATIONS – SUBJECT TO CHANGE

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals