Touch screen display

  • LCD Display touch terminals
  • Designed to make the interaction between man and machine simple and intuitive, making navigation easier between the various screens.
    Touch screen display
  1. Able to view the operating values from the circuit shown on the screen.
  2. Alarm
    • Active Alarm Compressor
    • Active Alarm Etc. ( Phase Protection, Flow Switch, Water Freeze, Chiller Water Pump, AUX pump )
  3. Setting
    • Set Water Temperature
    • Set Delay Time
    • Set Protection
    • Calibration
    • Supervisor
  4. Display locking by setting a password
    Touch screen display

Programmable logic control : PLC

  • Able to edit operation programs through “Host” and “Device” USB ports with standard USB flash drives
  • Direct connection PC without needing a serial converter.
  • (Option) Connection to the controller is available over an RS485 or Ethernet network using the Mod Bus or BACnet protocol.
    Programmable logic control

Semi-Hermetic screw compressor

  • Compressors maintain the liquid flow rate to meet the working load at 50% -100% (full load).
  • Effective under partial load and full load
  • Designed for commercial & industrial applications.
    Semi-Hermetic screw compressor

Refrigerant R134a

  • R134a is a refrigerant of the HFC group with no harmful effects on the ozone layer.
  • No toxic
  • Not combustible
  • Does not corrode equipment

Evaporator

(Shell and tube heat exchanger)

  • High efficiency performance , low water pressure drop Aluminium star rods fitted in copper tubing , create turbulence refrigerant flow and cause higher heat transfer efficiency.
  • Removable head and proper selection of head pass avoids excessive refrigerant pressure drops.
  • High column strength tube design reduces the hazard of freeze-up.
  • Thick insulation to prevent condensation.
    Evaporator

Condenser

(Shell and tube heat exchanger)

  • Cleanable water cooled condensers are heavy duty high efficiency condensers
  • Specially designed to simplify the mechanical cleaning necessary in area where poor water conditions exist.
  • Working pressure
    • Shell side, 325 PSI
    • Tube side, 125 PSI
    • Test pressure 1.25 times the design working pressure
  • Optional : Sea water application Copper-Nickels (90-10 / CU-NI), Tubes surrounded by steel outer tube (Shell).
    Condenser

Refrigeration part

  • Hi-Low pressure gauge
    Refrigeration part

  • Solenoid valve
    Use electric power to control valve opening and closing.
    Refrigeration part

  • Sight glass
    Characterize the state and humidity of the refrigerant.
    Refrigeration part

  • Filter drier
    Filters out dirt and absorbs moisture. If the machine does not work properly or has acid build-up, the filter drier will also absorb the acid by the filter drier’s inner filling.
    Refrigeration part

  • Chilled water flow switch
    Check water flow for protect system
    Refrigeration part

  • Thermostatic expansion valve
    Controls the amount of refrigerant entering the evaporator. By installing this thermostatic expansion valve on the inlet pipe before the refrigerant enters the evaporator.
    Refrigeration part

Electrical parts

  • Magnetic & Overload contractor for fan motor and compressor
  • Unit main breaker
  • Digital hour meter
  • Phase protection
  • Pressure transducer
  • Freeze stat
  • Crankcase heaters

Dimensional drawings

Dimensional drawings

WCU-CHB 050-080

WCU-CHB DIMENSION
A (mm.) B (mm.)
050 2,200
060 2,500
070 3,000
080 3,000

Dimensional drawings

W CU-CHB DIMENSION
A (mm.) B (mm.)
100 3,100
120 3,700
150 3,700
180 3,700
200 4,300
240 4,300

With International standard quality guaranteed by customers over 70 countries

PHYSICAL DATA

MODEL WCU-CHB| 050| 060| 070| 080| 100| 120| 150| 180| 200| 240
---|---|---|---|---|---|---|---|---|---|---
N O M I N A L C OO L I N G C A P A C I T Y| (MBH)| 517| 630| 668| 808| 1,034| 1,258| 1,456| 1,761| 2,007| 2,160
P O W E R C O N S U M P T I O N| kw| 36.7| 43.1| 45.9| 53.4| 73.4| 86.2| 99.0| 119.4| 134.8| 145.8
NOMINAL COP| kw/kw| 4.13| 4.28| 4.27| 4.43| 4.13| 4.28| 4.31| 4.32| 4.36| 4.34
IPLV.IP**| kw/kw| 4.83| 5.06| 4.99| 5.19| 4.83| 5.02| 5.04| 5.06| 5.11| 5.09
COMPRESSOR| TYPE| SCREW
HP.| 50| 60| 70| 80| 50| 60| 75| 90| 100| 120
Q T Y . / U N I T| 1| 2
R E F R I G E R A N T| TYPE| R134A
CHARGE| Holding
WATER COOLED CONDENSER| FOULING FACTOR| | 0.0005 (0.000046) Ft .h.F./BTU (m .h.F./BTU)
WATER FLOW RATE| (GPM)| 138| 168| 178| 215| 276| 335| 388| 470| 535| 576
E N T E R I N G W A T E R T E M P .| ( ํF )| 90
LEAVING WATER TEMP.| ( ํF )| 100
WATER PRESSURE DROP| (Ft.WG)| 6.78| 5.67| 5.9| 5.74| 13.56| 11.34| 11.8| 11.48| 20.52| 16.37
NO. OF WATER PASSER| | 2
W A T E R C O NN E C T I O N ( I N .. O U T )| INCH| 2-1/2…3| 3…4| 2-1/2…3| 3…4
Q T Y . / U N I T| | 1| 2
WATER CHILLER| FOULING FACTOR| | 0.0005 (0.000046) Ft .h. F./BTU (m .h. F./BTU)
N O . O F C I R C U I T| | 1| 2
CHILLED WATER FLOW RATE| (GPM)| 103| 126| 134| 162| 207| 252| 291| 352| 401| 432
C H I LL E D W A T E R T E M P . I N / O U T| ( ํF )| 55/45
CHILLED WATER PRESSURE DROP| (Ft. WG)| 3.87| 3.13| 8.07| 13.9| 8.63| 13.01| 14.71| 21.47| 10.04
W A T E R C O NN E C T I O N I N / O U T| INCH| 3| 4| 5| 6| 8
Q T Y . / U N I T| | 1
W E I G H T| (Kgs)| 1,622| 1,875| 1,993| 2,130| 2,740| 3,184| 3,601| 4,149| 4,696| 4,908
kW/Tons| 0.85| 0.82| 0.79| 0.85| 0.82| 0.81

Note MBH = 1000 BTUH
FOR SI. UNIT, COOLING CAPACITY (KW) = (MBH x 1000) / 3412

  • Nominal Cooling Capacity Based on 38 ํF Suction Temp. Liquid Subcooled 15 ํF
    **IPLV calculations according to standard performances (in accordance with AHRI 550-590)

ELECTRICAL DATA

MODEL WCU-CHB 050 060 070 080 100 120 150 180 200 240
COMPRESSOR (EACH) V/PH/Hz 380/3/50
POWER INPUT(kW) 36.7 43.1 45.9 53.4 36.7 43.1 49.5 59.7 67.4 72.9
RLA. (Amp.) 68.1 78.6 82.7 95.9 68.1 78.6 90.1 104.8 119.3 131.6
LRA. (Amp.) 230 260 345 230 260 345 292 407 443

Note
RLA = Rated Load Amp.
LRA = Locked Rotor Amp

CUSTOMER SUPPORT

Logos
Logos
Logos
Quality Product Manufacture by Member of The Federation of Thai Industries
PRIME MINISTER’S AWARD

  • BEST THAI BRAND
  • BEST EXPORTER
  • GERRN INNOVATION

UNIAIRE CORPORATION CO., LTD.
69 Moo 3 Kingkeaw Rd., Rachatewa District, Bangplee, Samutprakarn 10540 Thailand
Tel.+662-312-4500,
Email.export@uni-aire.com
www.uni-aire.com
Whatsapp.+666-2312-3069
Logo

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals