BOSCH BVMS Video Management Software User Guide

May 15, 2024
Bosch

BOSCH BVMS Video Management Software

BOSCH-BVMS-Video-Management-Software

Product Information

BVMS 12.1 is a video management system designed to provide comprehensive surveillance solutions for various applications.

Specifications

  • Product Name: BVMS 12.1
  • Author: Wrobel Maciej (BT-VS/XSW-SEC)
  • Release Date: 12 December 2023

Product Usage Instructions

Installation:

  1. Download the BVMS 12.1 installation package from the official website.
  2. Follow the installation guide provided in the documentation for step-by-step setup.
  3. Ensure that your system meets the minimum requirements specified for BVMS 12.1.

Configuration:

  1. After installation, launch the BVMS 12.1 application.
  2. Follow the on-screen instructions to configure your surveillance settings, cameras, and recording preferences.
  3. Set up user permissions and access controls to secure your surveillance system.

Operation:

  1. Monitor live feeds from connected cameras within the BVMS 12.1 interface.
  2. Review recorded footage and playback options for specific events or timeframes.
  3. Utilize the search and filter functions to easily locate relevant video footage.

Frequently Asked Questions (FAQ)

Q: What are the system requirements for running BVMS 12.1?
A: BVMS 12.1 requires a minimum of X GB RAM, X GHz processor, and X amount of storage space. Please refer to the official documentation for detailed system requirements.

Q: Can BVMS 12.1 support remote access to surveillance footage?
A: Yes, BVMS 12.1 offers remote access capabilities, allowing users to view live or recorded footage from any location with an internet connection. Ensure proper network configuration for remote access.

BVMS 12.1 – Release notes
Author:
Wrobel Maciej (BT-VS/XSW-SEC)
Date:
12 December 2023

BVMS 12.1 – Release notes

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

14.6 Patches issued 14.7 Resolved issues 14.8 Known issues
15 BVMS Version 7.5
15.1 Introduction 15.2 New features 15.3 Installation Notes 15.4 Firmware 15.5 Hardware 15.6 Patches issued 15.7 Resolved issues 15.8 Known issues
16 Bosch Video Management System Version 7.0
16.1 Introduction 16.2 New features 16.3 Installation Notes 16.4 Firmware 16.5 Hardware 16.6 Resolved issues 16.7 Known issues
17 Bosch Video Management System Version 6.5
17.1 Introduction 17.2 New features 17.3 Installation Notes 17.4 Firmware 17.5 Hardware 17.6 Resolved issues 17.7 Known issues
18 Bosch Video Management System 6.0
18.1 Introduction 18.2 New features 18.3 Installation Notes 18.4 Firmware 18.5 Hardware 18.6 Resolved issues 18.7 Known issues

5 | 139
98 13 13
112
105 112
7 106 114
98 13 13
119
105 112
7 106 114
13 13
124
105 112
7 106 114
13 13
131
105 112
7 106 114
13 13

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

6 | 139

Document history

This document is valid for all BVMS versions. Only the release notes of the latest BVMS version are fully updated and contain updates for earlier versions as well.

Date 2023-11-28

Version BVMS 12.1

Changes Initial release notes

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

7 | 139

2 BVMS Version 12.1

This document is distributed within the installation package, but is updated from time to time. The latest version of the Release Notes is always available on the Bosch Security Systems Product Catalog. Version 12.1 introduces new features and resolves issues compared to BVMS 12.0.1.

2.1 New functionality

ID

Description

261898

Improved hashing algorithm for stored passwords

368172

Multi-camera Forensic Search – two modes available (individual or common camera search). Improved task configuration and search status indication for Forensic Search. Unsynced playback available for individual cameras in playback mode. Bookmarks supporting unsynced playback cameras, including new way of exporting video for bookmarks

383139

Improved logging of the VRM

394089

Import device configuration from the CSV file

400388

Sharing favorites and bookmarks to file with the password protection

411761

Number of VRM playback sessions increased to 128

419722

Last used view for the panoramic camera will be stored when this camera is opened again

419738

Import and export of favorites and bookmarks to the file available as User Group permission

419908

GPS-based positioning for supporting moving cameras available for BVMS Server SDK

421106

Integration of new Tattile Stark camera models

2.2 Removed functionality

ID

Description

427964

Support of DVR600

2.3 Installation Notes
For system design specifications the BVMS architects and engineering specifications, system design guide and quick installation guide should be used. The BVMS upgrade guide helps you to upgrade an existing installation, and the BVMS security guide helps you to increase the security of your installation. The datasheet is subject to change. Translated versions are not published instantly; the English version is always up-to-date.

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

8 | 139

2.4 Disclaimer
BVMS is not designed, intended, or authorized for use in any type of system or application in which the failure of the Software could lead to a risk to health and safety. The user is responsible to verify that the Software and its specified functionalities are suitable for the intended application, in particular with respect to accuracy, safety and security.
2.5 Versions
The table below lists the firmware versions which are used in the BVMS system test. When available, the version contains a clickable download link.
Device Compatibility
Up until some years ago, new released cameras, encoders, domes and decoders that were introduced into market after a BVMS release could not be connected to an existing BVMS version because these cameras where not known to the BVMS. In the BVMS 4.5.1, a new concept was introduced. This concept treats Bosch video encoders and decoders as generic devices, and automatically recognizes specific device functionality (for example the number of streams, relays and inputs). Based on this information the, at that time, unknown device is added to the system and can be used by the operator. This document, which can be found in the Bosch Building Technologies community, provides a detailed description of this functionality: BVMS – Device compatibility.

Component Camera firmware Firmware MPEG-4 Firmware CPP3 Firmware CPP4 Firmware CPP5 Firmware CPP6 Firmware CPP7 Firmware CPP7.3 Firmware CPP13 Firmware CPP14.1
Firmware CPP14.2
Firmware CPP14.3

Version
4.15.0002 5.75.0011 7.10.0096 6.31.0019 7.87.0029 7.87.0029 7.87.0029 8.91.0028 8.80.0090, 9.00.0210 (please see note below if used in combination with VJD 8000) 8.80.0090, 9.00.0210 (please see note below if used in combination with VJD 8000) 9.00.0210 (please see note below if used in combination with VJD 8000)

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

9 | 139

Firmware Aviotec (CPP6) Firmware CPP-ENC* Firmware CPP-ENC Decoder firmware VJD 7000 Videojet decoder VJD 7513 Videojet decoder VJD 7523 Videojet decoder 8000
Barco RCP+ Agent Monitor Wall Software VRM VSG BIS Access Management System (AMS) Tracking and Recognition Service (TRS) Embedded components Web Client Intuikey Keyboard SQL Server BVMS Hardening Tool ONVIF Event driver tool VideoSDK

7.82.0025 5.54.0012 5.97.0013 (for VJT XF E family, VIDEOJET decoder 3000)
54.8.2 10.40.0061 10.40.0061 10.05.0001 (Important note: this decoder firmware version is not compatible with CPP14 firmware 9.00.0210. In combination with CPP14 please use the firmware version 8.80.0090 for cameras) 0.9.7.0 10.00.0164 (pre-configured from Configuration Manager)
4.30.0015 (64-bit) 9.1.1.1 5.0.21100 5.0.20
2.0.0.12
11.165 1.96 2019 11.1.0.8 2.1.2.1 6.60.0037

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

10 | 139

RCP+

5.03.0063

DVRs and other devices

DVR FW Version

2.6.0 (Divar AN 3000/5000) 3.3.1 (Divar Network/Hybrid)

Allegiant MCS

2.95

Cameo SDK

1.4.0.0

BVMS SDK

1.9.0.0

.NET framework

4.8

Bosch B- and G-Series Intrusion 3.14.012 Panel

NetApp E2800 SanTricity

11.80GA

RPS

6.14.001

CMLib

7.71.169

Operating systems

Operating systems Operator Client, Configuration Client

Windows 10 Professional (64-bit) (22H2) Windows 10 Enterprise (64-bit) LTSC (21H2) Windows 11 Pro (64-bit) (22H2)

Operating systems Management Server, Mobile Video Service

Windows (Storage) Server 2016 (64-bit) Windows (Storage) Server 2019 (64-bit) Windows (Storage) Server 2022 (64-bit) Windows 10 Professional (64-bit) (22H2) Windows 10 Enterprise (64-bit) LTSC (21H2) Windows 11 Pro (64-bit) (22H2)

Operating systems Video Recording Manager

Windows (Storage) Server 2016 (64-bit) Windows (Storage) Server 2019 (64-bit) Windows (Storage) Server 2022 (64-bit)

*Supported as legacy devices – since those devices reached End of Service phase, full functionality cannot be guaranteed.
2.6 BVMS Setup types and applicability
With BVMS 12.0 and Privacy overlay feature, two different types of setup are introduced:
Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

11 | 139

· BVMS Setup (standard) – not containing AI packages for Privacy overlay feature · BVMS Setup with AI – including AI packages for Privacy overlay feature Please refer to the table below for applicability of setup packages.

Component

BVMS Setup (standard)

BVMS Setup with Comments AI

BVMS server (standalone) yes

yes

BVMS Setup with AI can be used to

allow No-Touch Deployment of AI

packages for connected clients,

while standard setup is generally

sufficient for the server.

DIVAR IP

yes

no

BVMS Setup with AI is not

supported on DIVAR IP. Privacy

overlay feature can only be used on

workstations connected to DIVAR IP.

BVMS Operator Client with no Privacy overlay

yes

BVMS Setup with AI is required for

all the workstations, where Privacy

overlay feature will be used.

BVMS Operator Client

yes

without Privacy overlay

yes

BVMS Setup with AI can also be used

if Privacy overlay is not in use, while

standard setup would be sufficient.

BVMS setup compatibility
BVMS setup versions with and without AI packages are fully compatible with each other. For example, in case of:
· BVMS Setup (standard) installed on DIVAR IP acting as a server · BVMS Setup with AI installed on workstation, connecting to this DIVAR IP BVMS running on this workstation will be fully functional, including Privacy overlay feature that can be used on the client.

2.7 DIVAR IP

The following BVMS versions are supported on the specific DIVAR IP devices.

DIVAR IP

Genera CTN tion

Operating System

Minimum BVMS version

Update method Remarks

AiO

1

5000

DIP-52x

Windows Server 2016 R2

BVMS 9.0

System Manager package

Installation of System Manager 2.1 required as prerequisite.

AiO

1

7000

DIP-72x

Windows Server 2016 R2

BVMS 9.0

System Manager package

Installation of System Manager 2.1 required as prerequisite.

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

12 | 139

DIVAR IP

Genera CTN tion

Operating System

Minimum BVMS version

Update method Remarks

AiO

2

7000

DIP-73x Windows Server 2019

BVMS 10.1.1

System Manager package

Upgrade from Software Center to System Manager required as prerequisite.

AiO

1

4000

DIP-44x Windows Server 2022

BVMS 11.1.1

System Manager package

AiO

1

6000

DIP-64x Windows Server 2022

BVMS 11.1.1

System Manager package

When updating DIVAR IP appliance (DIVAR IP all-in-one 4000, DIVAR IP all-in- one 5000, DIVAR IP all-in-one 6000, and DIVAR IP all-in-one 7000 Gen2 and Gen3), managed by DIVAR IP System Manager, special corresponding packages are required to upgrade BVMS on these devices. Regular BVMS installer cannot be used anymore to update BVMS on DIVAR IP. Please note, that previous BVMS release (12.0.1) was the last version supported for DIVAR IP 7000 R2 (DIP- 71xx) appliances. Please refer to the document “DIVAR IP Software Info Brief” published on https:// downloadstore.boschsecurity.com/?type=DIPBVMS

2.8 Hardware drivers

Component

Version

NVIDIA Quadro

NVIDIA RTX / Quadro Desktop and Notebook Driver Release 525

Intel

Intel® Graphics – Windows® DCH Drivers HD Graphics 530/ UHD Graphics 630

Hardware requirements
Bosch strongly urges customers to use the driver versions mentioned above. This ensures that the software can perform its task reliably and the specified performance (Recent Intel drivers show issues with H.265 decoding).

2.9 Virtualization

Manufacturer

Fail-over mode

Microsoft

Fail-over cluster

VMware

High availability

Version Windows Server 2022 (Hyper-V version 7) vSphere 6.0, 7.0

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

13 | 139

Hardware requirements
The Video Recording Manager has an application specific fail-over mechanism that should be used. Virtualization-based fail-over mechanisms are not supported for the Video Recording Manager. The release notes of the Video Recording Manager provide information on the specific virtualization platforms that are supported considering this limitation.

Video Streaming Gateway
If the VSG runs on a Hyper-V fail-over cluster, and the hardware fails, recording is stopped for ~30 seconds. Live streaming via the VSG might cause a small interruption.

2.10 Patched issues for BVMS 12.1
A patch solves a very specific issue. Do not hesitate to reach out to our technical support teams in case you are experiencing an issue that is not described in these release notes.

ID

Description

Fixed in BVMS

BVMS Viewer

2.11 Resolved issues
The table below lists the issues that are resolved from previous releases. If an issue is known, but not described as resolved, it will not be fixed and we have accepted it’s behavior.

ID

Description

334635

Operator Client

FIXED: An OC showing GPU decoded cameos may run into an overload situation after a few hours as in some cases cameos may switch to CPU decoded mode.

366660

Logbook

FIXED: Alarm Title is cut off in Logbook after 64 characters.

400326

Configuration Client

FIXED: Newly added AUX commands to “Predefined positions and AUX commands” cannot be executed before saving the configuration.

2.12 Known issues

Known issues
Known issues are inherited by previous versions. If an issue is fixed, it will appear in the list of resolved issues. The issue IDs can be used to relate an issue to a resolution.

ID 273546

Subject
Operator Client

Description
In some cases, playback of audio for cameras attached to DVR might be distorted.

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

14 | 139

ID 283766
339032 346464 371804 375596 378719 379560 392522 409659 410592
416328 418415
424935 429120

Subject

Description

Setup

In some cases, temporary files are not removed from the %Temp% Windows folder when reboot is triggered directly after the setup. Please consider removing unnecessary files manually from the %Temp% folder after the setup or upgrade.

Operator Client

Transcoding a cameo of a sequence does not use transcoded streams, but non- transcoded streams instead.

Camera

Local storage replay and ANR playback are not working when the video is stored encrypted and if camera connection is set to “secured”.

Operator Client

Colored timeline: Depending on the timeline scale and number of events, loading of colored markings for events might take some time.

Operator Client

Colored timeline: When importing block export video recordings, colored markings might exceed actual available recordings range.

Operator Client

Colored timeline: Alarm recording markings might sporadically disappear and appear again after short period of time.

Operator Client

It might sporadically happen, that opening old recordings from the timeline results in jumping forward in time to more recent recordings.

Operator Client

Export with Privacy overlay of camera with G.726 audio codec might fail.

Central server After upgrading from BVMS 10.1 or lower, the file Bosch.VMS.BISProxy.settings.cxml is deleted and has to be created again.

Operator Client

Refreshing the recordings protection state on the timeline might take up to 1 minute in some cases, if no further actions with timeline are done in the meantime (zoom in, zoom out)

Setup

When installing MVS on a Windows 11 machine, additional step to install IIS 4.0 might be required. After reboot, the setup will continue.

Operator Client

Playback of video with very long GOPs (255) and low fps (15 or lower) might not work properly. In such case, it is advised to either reduce the GOP length or increase fps.

Configuration Schedule-based recording might not always work properly if configured for a

Client

holiday. As a workaround, camera should be recording using “exception day”

Configuration Client

Upgrading the firmware for CPP13 to the version 8.90 (or later) will result in unsecured ports closed in the camera. Please enable “Secured connection” option for the camera before upgrading the firmware in order to keep using it in BVMS. If unsecured connection is still expected, please make sure that corresponding ports and services are enabled again in the camera configuration.

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

15 | 139

ID 430103 430793 431190 434856 435034
435020 439196 439569

Subject

Description

Operator Client

When configuring VCA sensitive area using the Operator Client with 4K monitor, area drawing might not work correctly. It is advised to use standard (FullHD) resolution if VCA sensitive area is to be set using the Operator Client.

Forensic Search

If combination of Motion+ and EVA/IVA/IVA Pro algorithms is used for a single Forensic Search action, search results might not be consistent and no error message is shown.

AI Audio alarm

If audio alarm “Name” is empty in the camera configuration menu, AI audio alarm will not be triggered correctly by the camera.

Operator Client

Some embedded external applications might not start anymore on Windows 11.

Decoder

Videojet decoder 8000 firmware 10.05 is not compatible with CPP14 camera FW 9.00 or higher. If VJD 8000 decoders are used, please consider using FW 8.80 for the cameras or wait for the upcoming VJD 8000 firmware before upgrading the cameras to the FW 9.00.

Map

If camera is added to the map using new CSV file import feature, it will be by

default set to invisible. Please enable visibility for each camera and position it

as needed on the map.

Configuration Client

When BVMS user password configured in the Configuration Client is longer than 32 characters, login will not be possible again. Please do not use password longer than 32 characters.

Forensic Search

Metadata is not deleted when video recordings are manually deleted. As a result, metadata indication might still be visible when Forensic Search is performed even though recordings were manually deleted before.

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

16 | 139

3 BVMS Version 12.0.1

This document is distributed within the installation package, but is updated from time to time. The latest version of the Release Notes is always available on the Bosch Security Systems Product Catalog. Version 12.0.1 introduces new features and resolves issues compared to BVMS 12.0.

3.1 New functionality

ID

Description

234992

Configuration Audit Trail

366566

REST API integration interface for BVMS Virtual Inputs

397447

Rework of the camera adding dialogs to adjust to the camera firmware changes

405774

Client dewarping for VSG cameras

400388

Favorites and Bookmarks – password protection available for exported files

413231

Setup adjustments for DIVAR IP

3.1.1 Audit Trail
BVMS 12.0.1 introduces new Audit Trail feature. It allows storing configuration changes (performed in BVMS Configuration Client) for the audit purposes and for the later review.
In order to use the Audit Trail feature, please make sure to install the additional component of “Audit Trail database” (deselected by default) during BVMS installation. Installing Audit Trail database will require additional 10GB HDD space to be reserved.
Once installed, Audit Trail has to be enabled in the BVMS Configuration Client settings. It is advised to enable it after performing initial system configuration.
Audit Trail feature is not supported and cannot be installed on DIVAR IP 7000 R2 (DIP-71xx) appliance, running Windows (Storage) Server 2012 operating system.

3.2 Removed functionality

ID

Description

3.3 Installation Notes
For system design specifications the BVMS architects and engineering specifications, system design guide and quick installation guide should be used. The BVMS upgrade guide helps you to upgrade an existing installation, and the BVMS security guide helps you to increase the security of your installation. The datasheet is subject to change. Translated versions are not published instantly; the English version is always up-to-date.

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

17 | 139

3.4 Versions
The table below lists the firmware versions which are used in the BVMS system test. When available, the version contains a clickable download link.
Device Compatibility
Up until some years ago, new released cameras, encoders, domes and decoders that were introduced into market after a BVMS release could not be connected to an existing BVMS version because these cameras where not known to the BVMS. In the BVMS 4.5.1, a new concept was introduced. This concept treats Bosch video encoders and decoders as generic devices, and automatically recognizes specific device functionality (for example the number of streams, relays and inputs). Based on this information the, at that time, unknown device is added to the system and can be used by the operator. This document, which can be found in the Bosch Building Technologies community, provides a detailed description of this functionality: BVMS – Device compatibility.

Component Camera firmware Firmware MPEG-4 Firmware CPP3 Firmware CPP4 Firmware CPP5 Firmware CPP6 Firmware CPP7 Firmware CPP7.3 Firmware CPP13 Firmware CPP14.1 Firmware CPP14.2 Firmware Aviotec Firmware CPP-ENC Firmware CPP-ENC Firmware X1/X2 Decoder firmware

Version
4.15.0002 5.75.0011 7.10.0096 6.31.0019 7.87.0029 7.87.0029 7.87.0029 8.48.0017 8.80.0090 8.80.0090 7.82.0025 5.54.0012 5.97.0013 (for VJT XF E family, VIDEOJET decoder 3000) 2.53.0005

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

18 | 139

VJD 7000 Videojet decoder VJD 7513 Videojet decoder VJD 7523 Videojet decoder 8000 Barco RCP+ Agent Monitor Wall Software VRM VSG BIS Access Management System (AMS) Tracking and Recognition Service (TRS) Embedded components Web Client Intuikey Keyboard SQL Server BVMS Hardening Tool ONVIF Event driver tool VideoSDK RCP+ DVRs and other devices DVR FW Version
Allegiant MCS

54.8.2 10.31.0005 10.40.0055 10.05.0001 0.9.7.0 10.0 (pre-configured from Configuration Manager)
4.20.0016 (64-bit) 9.1.0.12 5.0.21100 5.0.20
2.0.0.12
11.165 1.96 2019 11.1.0.8 2.0.0.8 6.50.0030 5.03.0063
2.6.0 (Divar AN 3000/5000) 3.3.1 (Divar Network/Hybrid) 2.95

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

19 | 139

Cameo SDK

1.4.0.0

BVMS SDK

1.9.0.0

.NET framework

4.8

Bosch B- and G-Series Intrusion 3.14.012 Panel

NetApp E2800 SanTricity

11.70.3P1

RPS

6.14.001

CMLib

7.70.88

Operating systems

Operating systems Operator Client, Configuration Client

Windows 10 Professional (64-bit) (22H2) Windows 10 Enterprise (64-bit) LTSC (21H2) Windows 11 Pro (64-bit) (22H2)

Operating systems Management Server, Mobile Video Service

Windows (Storage) Server 2012 R2 (64-bit)** Windows (Storage) Server 2016 (64-bit) Windows (Storage) Server 2019 (64-bit) Windows (Storage) Server 2022 (64-bit) Windows 10 Professional (64-bit) (22H2) Windows 10 Enterprise (64-bit) LTSC (21H2) Windows 11 Pro (64-bit) (22H2)

Operating systems Video Recording Manager

Windows (Storage) Server 2012 R2 (64-bit) Windows (Storage) Server 2016 (64-bit) Windows (Storage) Server 2019 (64-bit) Windows (Storage) Server 2022 (64-bit)

*Supported as legacy devices – since those devices reached End of Service phase, full functionality cannot be guaranteed. **Windows (Storage) Server 2012 R2 (64-bit) is only supported when updating your BVMS on DIVAR IP 7000R2 (DIP-71xx) from version 10.1 or lower. MS SQL Server 2019, used as a standard version for BVMS 11.0 or higher, is not supported anymore on Windows (Storage) Server 2012 R2 (64-bit). Therefore, in case of an upgrade scenario, MS SQL Server will remain on version 2017 and such combination is still supported with BVMS 11.0 or higher. However, for this reason it is not possible to deploy new BVMS 11.0 or higher installation on Windows (Storage) Server 2012 R2, as MS SQL 2019 installation will fail. Audit Trail feature is not supported for Windows (Storage) Server 2012 operating system.
3.5 BVMS Setup types and applicability
With BVMS 12.0 and Privacy overlay feature, two different types of setup are introduced:

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

20 | 139

· BVMS Setup (standard) – not containing AI packages for Privacy overlay feature · BVMS Setup with AI – including AI packages for Privacy overlay feature Please refer to the table below for applicability of setup packages.

Component

BVMS Setup (standard)

BVMS Setup with Comments AI

BVMS server (standalone) yes

yes

BVMS Setup with AI can be used to

allow No-Touch Deployment of AI

packages for connected clients,

while standard setup is generally

sufficient for the server.

DIVAR IP

yes

no

BVMS Setup with AI is not

supported on DIVAR IP. Privacy

overlay feature can only be used on

workstations connected to DIVAR IP.

BVMS Operator Client with no Privacy overlay

yes

BVMS Setup with AI is required for

all the workstations, where Privacy

overlay feature will be used.

BVMS Operator Client

yes

without Privacy overlay

yes

BVMS Setup with AI can also be used

if Privacy overlay is not in use, while

standard setup would be sufficient.

BVMS setup compatibility
BVMS setup versions with and without AI packages are fully compatible with each other. For example, in case of:
· BVMS Setup (standard) installed on DIVAR IP acting as a server · BVMS Setup with AI installed on workstation, connecting to this DIVAR IP BVMS running on this workstation will be fully functional, including Privacy overlay feature that can be used on the client.

3.6 DIVAR IP

The following BVMS versions are supported on the specific DIVAR IP devices.

DIVAR IP

Genera CTN tion

Operating System

Minimum BVMS version

Update method Remarks

AiO

1

5000

DIP-52x

Windows Server 2016 R2

BVMS 9.0

System Manager package

Installation of System Manager 2.1 required as prerequisite.

AiO

1

7000

DIP-72x

Windows Server 2016 R2

BVMS 9.0

System Manager package

Installation of System Manager 2.1 required as prerequisite.

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

21 | 139

DIVAR IP

Genera CTN tion

Operating System

Minimum BVMS version

Update method Remarks

AiO

2

7000

DIP-73x Windows Server 2019

BVMS 10.1.1

System Manager package

Upgrade from Software Center to System Manager required as prerequisite.

AiO

1

4000

DIP-44x Windows Server 2022

BVMS 11.1.1

System Manager package

AiO

1

6000

DIP-64x Windows Server 2022

BVMS 11.1.1

System Manager package

When updating DIVAR IP appliance, regular BVMS installer should only be used for DIVAR IP 7000 R2 (DIP-71xx). Please note, that for DIVAR IP all-in-one 4000, DIVAR IP all-in-one 5000, DIVAR IP all-in-one 6000, and DIVAR IP all-in- one 7000 Gen2 and Gen3, managed by DIVAR IP System Manager, special corresponding packages are required to upgrade BVMS on these devices. Please refer to the document “DIVAR IP Software Info Brief” published on https:// downloadstore.boschsecurity.com/?type=DIPBVMS

3.7 Hardware drivers

Component

Version

NVIDIA Quadro

NVIDIA RTX / Quadro Desktop and Notebook Driver Release 525

Intel

Intel® Graphics – Windows® DCH Drivers HD Graphics 530/ UHD Graphics 630

Hardware requirements
Bosch strongly urges customers to use the driver versions mentioned above. This ensures that the software can perform its task reliably and the specified performance (Recent Intel drivers show issues with H.265 decoding).

3.8 Virtualization

Manufacturer

Fail-over mode

Microsoft

Fail-over cluster

VMware

High availability

Version Windows Server 2022 (Hyper-V version 7) vSphere 6.0, 7.0

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

22 | 139

Hardware requirements
The Video Recording Manager has an application specific fail-over mechanism that should be used. Virtualization-based fail-over mechanisms are not supported for the Video Recording Manager. The release notes of the Video Recording Manager provide information on the specific virtualization platforms that are supported considering this limitation.

Video Streaming Gateway
If the VSG runs on a Hyper-V fail-over cluster, and the hardware fails, recording is stopped for ~30 seconds. Live streaming via the VSG might cause a small interruption.

3.9 Patched issues for BVMS 12.0.1
A patch solves a very specific issue. Do not hesitate to reach out to our technical support teams in case you are experiencing an issue that is not described in these release notes.

ID

Description

Fixed in BVMS

BVMS Viewer

3.10 Resolved issues
The table below lists the issues that are resolved from previous releases. If an issue is known, but not described as resolved, it will not be fixed and we have accepted it’s behavior.

ID

Description

367240

Camera

FIXED: CPP14 might not always return to original fps when closing the second stream. To be resolved with firmware release.

414506

User manual

FIXED: User manual indicates incorrect port numbers, used by Workstation Monitoring service. The correct values are: 5410 and 5411.

428521

Security fix

FIXED: Security fix in RCP+ SDK (CVE-2023-35867)

3.11 Known issues

Known issues
Known issues are inherited by previous versions. If an issue is fixed, it will appear in the list of resolved issues. The issue IDs can be used to relate an issue to a resolution.

ID 273546 334635

Subject
Operator Client
Operator Client

Description
In some cases, playback of audio for cameras attached to DVR might be distorted.
An OC showing GPU decoded cameos may run into an overload situation after a few hours as in some cases cameos may switch to CPU decoded mode.

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

23 | 139

ID 339032 346464 351924 366660 371804 375596 378719 379560 392522 398300
400326 408235 409659 410592
413287

Subject

Description

Operator Client

Transcoding a cameo of a sequence does not use transcoded streams, but non- transcoded streams instead.

Camera

Local storage replay and ANR playback are not working when the video is stored encrypted and if camera connection is set to “secured”.

SQL Server

MS SQL Server update to 2019 silently fails on Windows Server 2012 R2 and stays on MS SQL Server 2017.

Logbook

Alarm Title is cut off in Logbook after 64 characters.

Operator Client

Colored timeline: Depending on the timeline scale and number of events, loading of colored markings for events might take some time.

Operator Client

Colored timeline: When importing block export video recordings, colored markings might exceed actual available recordings range.

Operator Client

Colored timeline: Alarm recording markings might sporadically disappear and appear again after short period of time.

Operator Client

It might sporadically happen, that opening old recordings from the timeline results in jumping forward in time to more recent recordings.

Operator Client

Export with Privacy overlay of camera with G.726 audio codec might fail.

Tatille LPR camera

If using Tattile LPR camera, after upgrading to BVMS 12.0 the following steps are required, due to changes in the camera firmware:
· Upload new “LPR_Event_Template.txt” file to the camera · Open “Edit” dialog for Tattile camera and press “Authenticate” to
retrieve updated information from the camera · Verify, that correct “Device Serial Number” is displayed on
Properties tab.

Configuration Newly added AUX commands to “Predefined positions and AUX commands”

Client

cannot be executed before saving the configuration.

Keyboard

IntuiKey keyboards cannot address logical numbers >999 for Monitor Group

Central server After upgrading from BVMS 10.1 or lower, the file Bosch.VMS.BISProxy.settings.cxml is deleted and has to be created again.

Operator Client

Refreshing the recordings protection state on the timeline might take up to 1 minute in some cases, if no further actions with timeline are done in the meantime (zoom in, zoom out)

Decoder

Panoramic presets are not working on decoder, if camera mounting position is set to “Floor”

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

24 | 139

ID 413824
416328 418066 418415
422324 424935

Subject

Description

Setup

In some cases, update setup on Windows Server might fail, due to known OS bug (KB #4506040). In such case, please reboot the system and try running the setup again.

Setup

When installing MVS on a Windows 11 machine, additional step to install IIS 4.0 might be required. After reboot, the setup will continue.

Configuration Audit Trail: single Audit Trail entry cannot contain more than 100 000 lines. Client

Operator Client

Playback of video with very long GOPs (255) and low fps (15 or lower) might not work properly. In such case, it is advised to either reduce the GOP length or increase fps.

Configuration When manually adding a new camera, the process of adding might in some

Client

cases take up to 3-5 seconds.

Configuration Schedule-based recording might not always work properly if configured for a

Client

holiday. As a workaround, camera should be recording using “exception day”

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

25 | 139

4 BVMS Version 12.0

This document is distributed within the installation package, but is updated from time to time. The latest version of the Release Notes is always available on the Bosch Security Systems Product Catalog. Version 12.0 introduces new features and resolves issues compared to BVMS 11.1.1.

4.1 New functionality

ID

Description

320894

Privacy overlay: AI based anonymization

358395

Threat Level Management: dynamic changes of user permissions

358394

Global protect/restrict/delete recordings actions available for Logical Tree elements

353383

Possibility to limit access to SDK or various applications for BVMS users

251481

ONVIF Profile T conformance changes: support of metadata from ONVIF Profile T cameras and two-way audio

400066

Displaying of VCA metadata for alarm can be enabled/disabled by user

332919

Renaming of root node of Logical Tree possible

393169

Panoramic presets call-up on decoder available using Server SDK

396093

Support of new IVA detectors

383464

Support for VJD-7523 decoders

228604

Import/export mechanism for favorites and bookmarks

377909

Availability of recent (60s) recordings limited for users without permission for live view

383465

SDK Logbook Export is now able to provide a local time

394791

Device based licensing – extended for CPP6 and CPP7 cameras

352573

Workstation Monitoring interface (Note: using new ports 5410 and 5411)

395165

Live/playback webpage available for VRM

345974

Number of alarm rows for Enterprise Operator Client follows the max. value for configured subsystems

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

26 | 139

4.2 Removed functionality

ID

Description

4.3 Installation Notes
For system design specifications the BVMS architects and engineering specifications, system design guide and quick installation guide should be used. The BVMS upgrade guide helps you to upgrade an existing installation, and the BVMS security guide helps you to increase the security of your installation. The datasheet is subject to change. Translated versions are not published instantly; the English version is always up-to-date.
4.4 Versions
The table below lists the firmware versions which are used in the BVMS system test. When available, the version contains a clickable download link.
Device Compatibility
Up until some years ago, new released cameras, encoders, domes and decoders that were introduced into market after a BVMS release could not be connected to an existing BVMS version because these cameras where not known to the BVMS. In the BVMS 4.5.1, a new concept was introduced. This concept treats Bosch video encoders and decoders as generic devices, and automatically recognizes specific device functionality (for example the number of streams, relays and inputs). Based on this information the, at that time, unknown device is added to the system and can be used by the operator. This document, which can be found in the Bosch Building Technologies community, provides a detailed description of this functionality: BVMS – Device compatibility.

Component Camera firmware Firmware MPEG-4 Firmware CPP3 Firmware CPP4 Firmware CPP5 Firmware CPP6 Firmware CPP7 Firmware CPP7.3 Firmware CPP13

Version
4.15.0002 5.75.0011 7.10.0096 6.31.0019 7.86.0019 7.86.0019 7.86.0019 8.47.0026

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

Firmware CPP14.1 Firmware CPP14.2 Firmware Aviotec Firmware CPP-ENC Firmware CPP-ENC Firmware X1/X2 Decoder firmware VJD 7000 Videojet decoder VJD 7513 Videojet decoder VJD 7523 Videojet decoder 8000 Barco RCP+ Agent Monitor Wall Software VRM VSG BIS Access Management System (AMS) Tracking and Recognition Service (TRS) Embedded components Web Client Intuikey Keyboard SQL Server

8.71.0066 8.71.0066 7.82.0025 5.54.0012 5.97.0013 (for VJT XF E family, VIDEOJET decoder 3000) 2.53.0005
54.8.2 10.31.0005 10.40.0055 10.05.0001 0.9.7.0 10.0 (pre-configured from Configuration Manager)
4.10.0079 (64-bit) 9.0.0.178 4.9.1200 5.0.20
2.0.0.12
11.165 1.96 2019

27 | 139

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

BVMS Hardening Tool

11.1.0.8

ONVIF Event driver tool

2.0.0.8

VideoSDK

6.50.0028

RCP+

5.03.0063

DVRs and other devices

DVR FW Version

2.6.0 (Divar AN 3000/5000) 3.3.1 (Divar Network/Hybrid)

Allegiant MCS

2.95

Cameo SDK

1.4.0.0

BVMS SDK

1.9.0.0

.NET framework

4.8

Bosch B- and G-Series Intrusion 3.12.024 Panel

NetApp E2800 SanTricity

11.70.3P1

RPS

6.10.001

CMLib

7.62.0176

Operating systems

Operating systems Operator Client, Configuration Client

Windows 10 Professional (64-bit) (22H2) Windows 10 Enterprise (64-bit) LTSC (21H2) Windows 11 Pro (64-bit) (22H2)

Operating systems Management Server, Mobile Video Service

Windows (Storage) Server 2012 R2 (64-bit)** Windows (Storage) Server 2016 (64-bit) Windows (Storage) Server 2019 (64-bit) Windows (Storage) Server 2022 (64-bit) Windows 10 Professional (64-bit) (22H2) Windows 10 Enterprise (64-bit) LTSC (21H2) Windows 11 Pro (64-bit) (22H2)

28 | 139

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

29 | 139

Operating systems Video Recording Manager

Windows (Storage) Server 2012 R2 (64-bit) Windows (Storage) Server 2016 (64-bit) Windows (Storage) Server 2019 (64-bit) Windows (Storage) Server 2022 (64-bit)

*Supported as legacy devices – since those devices reached End of Service phase, full functionality cannot be guaranteed. **Windows (Storage) Server 2012 R2 (64-bit) is only supported when updating your BVMS from version 10.1 or lower. MS SQL Server 2019, used as a standard version for BVMS 11.0 or higher, is not supported anymore on Windows (Storage) Server 2012 R2 (64-bit). Therefore, in case of an upgrade scenario, MS SQL Server will remain on version 2017 and such combination is still supported with BVMS 11.0or higher. However, for this reason it is not possible to deploy new BVMS 11.0 or higher installation on Windows (Storage) Server 2012 R2, as MS SQL 2019 installation will fail.

4.5 BVMS Setup types and applicability
With BVMS 12.0 and Privacy overlay feature, two different types of setup are introduced:
· BVMS Setup (standard) – not containing AI packages for Privacy overlay feature · BVMS Setup with AI – including AI packages for Privacy overlay feature Please refer to the table below for applicability of setup packages.

Component

BVMS Setup (standard)

BVMS Setup with Comments AI

BVMS server (standalone) yes

yes

BVMS Setup with AI can be used to

allow No-Touch Deployment of AI

packages for connected clients,

while standard setup is generally

sufficient for the server.

DIVAR IP

yes

no

BVMS Setup with AI is not

supported on DIVAR IP. Privacy

overlay feature can only be used on

workstations connected to DIVAR IP.

BVMS Operator Client with no Privacy overlay

yes

BVMS Setup with AI is required for

all the workstations, where Privacy

overlay feature will be used.

BVMS Operator Client

yes

without Privacy overlay

yes

BVMS Setup with AI can also be used

if Privacy overlay is not in use, while

standard setup would be sufficient.

BVMS setup compatibility
BVMS setup versions with and without AI packages are fully compatible with each other. For example, in case of:
· BVMS Setup (standard) installed on DIVAR IP acting as a server · BVMS Setup with AI installed on workstation, connecting to this DIVAR IP BVMS running on this workstation will be fully functional, including Privacy overlay feature that can be used on the client.

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

30 | 139

4.6 DIVAR IP
The following BVMS versions are supported on the specific DIVAR IP devices.

DIVAR IP

Genera CTN tion

Operating System

Minimum BVMS version

Update method Remarks

AiO

1

5000

DIP-52x

Windows Server 2016 R2

BVMS 9.0

System Manager package

Installation of System Manager 2.1 required as prerequisite.

AiO

1

7000

DIP-72x

Windows Server 2016 R2

BVMS 9.0

System Manager package

Installation of System Manager 2.1 required as prerequisite.

AiO

2

7000

DIP-73x Windows Server 2019

BVMS 10.1.1

System Manager package

Upgrade from Software Center to System Manager required as prerequisite.

AiO

1

4000

DIP-44x Windows Server 2022

BVMS 11.1.1

System Manager package

AiO

1

6000

DIP-64x Windows Server 2022

BVMS 11.1.1

System Manager package

For BVMS 11.1.1 and BVMS 12.0.0, no additional steps are required when upgrading BVMS on a DIVAR IP with regular BVMS installer. Please note, that for DIVAR IP all-in-one 4000, DIVAR IP allin-one 6000, and DIVAR IP all-in-one 7000 Gen3, managed by DIVAR IP System Manager or DIVAR IP Software Center utilities, special corresponding packages are required to upgrade BVMS on these devices. Please refer to the document “DIVAR IP Software Info Brief” published on https:// downloadstore.boschsecurity.com/?type=DIPBVMS

4.7 Hardware drivers

Component

Version

NVIDIA Quadro

NVIDIA RTX / Quadro Desktop and Notebook Driver Release 525

Intel

Intel® Graphics – Windows® DCH Drivers HD Graphics 530/ UHD Graphics 630

Hardware requirements
Bosch strongly urges customers to use the driver versions mentioned above. This ensures that the software can perform its task reliably and the specified performance (Recent Intel drivers show issues with H.265 decoding).

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

31 | 139

4.8 Virtualization

Manufacturer

Fail-over mode

Microsoft

Fail-over cluster

VMware

High availability

Version Windows Server 2022 (Hyper-V version 7) vSphere 6.0, 7.0

Hardware requirements The Video Recording Manager has an application specific fail-over mechanism that should be used. Virtualization-based fail-over mechanisms are not supported for the Video Recording Manager. The release notes of the Video Recording Manager provide information on the specific virtualization platforms that are supported considering this limitation.
Video Streaming Gateway If the VSG runs on a Hyper-V fail-over cluster, and the hardware fails, recording is stopped for ~30 seconds. Live streaming via the VSG might cause a small interruption.

4.9 Patched issues for BVMS 12.0
A patch solves a very specific issue. Do not hesitate to reach out to our technical support teams in case you are experiencing an issue that is not described in these release notes.

ID

Description

Fixed in BVMS

BVMS Viewer

FIXED:

4.10 Resolved issues
The table below lists the issues that are resolved from previous releases. If an issue is known, but not described as resolved, it will not be fixed and we have accepted it’s behavior.

ID

Description

345746

Operator Client

FIXED: Timeline search might fail with very few alarms over a very long period of time for some devices.

381138

MVS

FIXED: CPP13 and CPP14 cameras might not work with Mobile Video Service

380121

Operator Client

FIXED: Timeline event search for Motion and Alarm for DVR 600/700 recorders does not deliver results.

377286

Operator Client

FIXED: Colored timeline: it might happen sporadically, that alarm recording indication extends between two consecutive alarms.

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

32 | 139

ID 355155 360387 368190 375281
375149 368140 378413

Description Keyboard Camera Camera Camera
Configuration Client Configuration Client Operator Client

FIXED: Keyboard connected to VJD-7513 decoder in BVMS environment is not supported yet.
FIXED: CPP14 camera might not show live video under certain circumstances for lower resolution streams.
FIXED: Playback jumps during alarm recording with stream switching for CPP13 and CPP14 cameras.
FIXED: If using Bosch CPP13 or CPP14 based cameras, multicast stream is self- configured by the camera, even if not configured in the camera menu before. It might result in network issues if network infrastructure is not prepared for multicast. This issue is visible for fw 8.45.0017 or lower (CPP13), 8.30.0082 or lower (CPP14.1), 8.50.0138 or lower (CPP14.2).
FIXED: Performing factory default (“Restore settings”) for CPP13 cameras might result in BVMS Configuration Client crash.
FIXED: Not all mounting position options available for configuration with CPP14.2 cameras. As a workaround, Configuration Manager should be used.
FIXED: If manually positioned timeline into the alarm period of recordings (after the moment when alarm started), Text Data might not be displayed properly for CPP13 or CPP14 cameras recordings.

4.11 Known issues

Known issues
Known issues are inherited by previous versions. If an issue is fixed, it will appear in the list of resolved issues. The issue IDs can be used to relate an issue to a resolution.

ID 273546 334635 339032 346464

Subject
Operator Client
Operator Client
Operator Client
Camera

Description
In some cases, playback of audio for cameras attached to DVR might be distorted.
An OC showing GPU decoded cameos may run into an overload situation after a few hours as in some cases cameos may switch to CPU decoded mode.
Transcoding a cameo of a sequence does not use transcoded streams, but non- transcoded streams instead.
Local storage replay and ANR playback are not working when the video is stored encrypted and if camera connection is set to “secured”.

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

33 | 139

ID 351924 359472 366660 367240 371804 375596 378719 379560 380845 392522 398300
400326 408235 409659 410592

Subject

Description

SQL Server

MS SQL Server update to 2019 silently fails on Windows Server 2012 R2 and stays on MS SQL Server 2017.

VSG

In some cases misleading “Configuration mismatch” information displayed

for VSG cameras, while system is fully operational.

Logbook

Alarm Title is cut off in Logbook after 64 characters.

Camera

CPP14 might not always return to original fps when closing the second stream. To be resolved with firmware release.

Operator Client

Colored timeline: Depending on the timeline scale and number of events, loading of colored markings for events might take some time.

Operator Client

Colored timeline: When importing block export video recordings, colored markings might exceed actual available recordings range.

Operator Client

Colored timeline: Alarm recording markings might sporadically disappear and appear again after short period of time.

Operator Client

It might sporadically happen, that opening old recordings from the timeline results in jumping forward in time to more recent recordings.

Operator Client

Colored timeline: when observing timeline with ongoing recording, it might sporadically happen, that colored markings exceed actual recording range.

Operator Client

Export with Privacy overlay of camera with G.726 audio codec might fail.

Tatille LPR camera

If using Tattile LPR camera, after upgrading to BVMS 12.0 the following steps are required, due to changes in the camera firmware:
· Upload new “LPR_Event_Template.txt” file to the camera · Open “Edit” dialog for Tattile camera and press “Authenticate” to
retrieve updated information from the camera · Verify, that correct “Device Serial Number” is displayed on
Properties tab.

Configuration Newly added AUX commands to “Predefined positions and AUX commands”

Client

cannot be executed before saving the configuration.

Keyboard

IntuiKey keyboards cannot address logical numbers >999 for Monitor Group

Central server After upgrading from BVMS 10.1 or lower, the file Bosch.VMS.BISProxy.settings.cxml is deleted and has to be created again.

Operator Client

Refreshing the recordings protection state on the timeline might take up to 1 minute in some cases, if no further actions with timeline are done in the meantime (zoom in, zoom out)

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

34 | 139

ID 413287 413824
414506

Subject

Description

Decoder

Panoramic presets are not working on decoder, if camera mounting position is set to “Floor”

Setup

In some cases, update setup on Windows Server might fail, due to known OS bug (KB #4506040). In such case, please reboot the system and try running the setup again.

User manual User manual indicates incorrect port numbers, used by Workstation Monitoring service. The correct values are: 5410 and 5411.

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

35 | 139

5 BVMS Version 11.1.1

This document is distributed within the installation package, but is updated from time to time. The latest version of the Release Notes is always available on the Bosch Security Systems Product Catalog. Version 11.1.1 introduces new features and resolves issues compared to BVMS 11.1. Please note: Since BVMS 11.1 version was not made available publicly, please see BVMS 11.1 Release Notes below to review all the changes comparing to BVMS 11.0.

5.1 New functionality

ID

Description

343011

Colored timeline enabled for VRM and DVR recordings

359901

Support of encrypted multicast streaming and SRTP for CPP13 / CPP14 cameras

343024

Date/time stamp as subtitles available for MP4/MOV exported recordings

Since BVMS 11.1 version was not made available publicly, please see BVMS 11.1 Release Notes below to review all the new functionalities, compared to BVMS 11.0.

5.2 Removed functionality

ID

Description

5.3 Installation Notes
For system design specifications the BVMS architects and engineering specifications, system design guide and quick installation guide should be used. The BVMS upgrade guide helps you to upgrade an existing installation, and the BVMS security guide helps you to increase the security of your installation. The datasheet is subject to change. Translated versions are not published instantly; the English version is always up-to-date.
5.4 Versions
The table below lists the firmware versions which are used in the BVMS system test. When available, the version contains a clickable download link.

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

36 | 139

Device Compatibility
Up until some years ago, new released cameras, encoders, domes and decoders that were introduced into market after a BVMS release could not be connected to an existing BVMS version because these cameras where not known to the BVMS. In the BVMS 4.5.1, a new concept was introduced. This concept treats Bosch video encoders and decoders as generic devices, and automatically recognizes specific device functionality (for example the number of streams, relays and inputs). Based on this information the, at that time, unknown device is added to the system and can be used by the operator. This document, which can be found in the Bosch Building Technologies community, provides a detailed description of this functionality: BVMS – Device compatibility.

Component Camera firmware Firmware MPEG-4 Firmware CPP3 Firmware CPP4 Firmware CPP5 Firmware CPP6 Firmware CPP7 Firmware CPP7.3 Firmware CPP13 Firmware CPP14.1 Firmware CPP14.2 Firmware Aviotec Firmware CPP-ENC Firmware CPP-ENC Firmware X1/X2* Decoder firmware VJD 7000 Videojet decoder 7000 Videojet decoder 8000

Version
4.15.0002 5.75.0011 7.10.0095 6.31.0010 7.84.0023 7.84.0023 7.84.0023 8.41.0029, 8.45.0018 8.30.0082 8.50.0138 7.82.0025 5.54.0012 5.97.0013 (for VJT XF E family, VIDEOJET decoder 3000) 2.53.0005
54.8.2 10.23.0002 10.05.0001

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

Barco RCP+ Agent Monitor Wall Software VRM VSG BIS Access Management System (AMS) Tracking and Recognition Service (TRS) Embedded components Web Client Intuikey Keyboard SQL Server BVMS Hardening Tool ONVIF Event driver tool VideoSDK RCP+ DVRs and other devices DVR FW Version
Allegiant MCS Cameo SDK BVMS SDK .NET framework

0.9.61 10.0 (pre-configured from Configuration Manager)
4.03.0025 (64-bit) 8.1.0.59 4.9.11200 4.9.10020
2.0.0.12
11.165 1.96 2019 11.1.0.8 2.0.0.8 6.40.0021 5.02.0040
2.6.0 (Divar AN 3000/5000) 3.3.0 (Divar Network/Hybrid) 2.95 1.4.0.0 1.9.0.0 4.8

37 | 139

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

38 | 139

Bosch B- and G-Series Intrusion 3.12.020 Panel

NetApp E2800 SanTricity

11.70.1 R1

RPS

6.10.001

CMLib

7.51.0092

Operating systems

Operating systems Operator Client, Configuration Client

Windows 10 Professional (64-bit) (20H2) Windows 10 Professional (64-bit) (21H1) Windows 10 Professional (64-bit) (21H2) Windows 10 Enterprise (64-bit) LTSC build 1809 Windows 11 Pro (64-bit) (21H2)

Operating systems Management Server, Mobile Video Service

Windows (Storage) Server 2012 R2 (64-bit)** Windows (Storage) Server 2016 (64-bit) Windows (Storage) Server 2019 (64-bit) Windows (Storage) Server 2022 (64-bit) Windows 10 Professional (64-bit) (20H2) Windows 10 Professional (64-bit) (21H1) Windows 10 Professional (64-bit) (21H2) Windows 10 Enterprise (64-bit) LTSC build 1809

Operating systems Video Recording Manager

Windows (Storage) Server 2012 R2 (64-bit) Windows (Storage) Server 2016 (64-bit) Windows (Storage) Server 2019 (64-bit)

*Supported as legacy devices – since those devices reached End of Service phase, full functionality cannot be guaranteed. **Windows (Storage) Server 2012 R2 (64-bit) is only supported when updating your BVMS from version 10.1 or lower. MS SQL Server 2019, used as a standard version for BVMS 11.0 and 11.1, is not supported anymore on Windows (Storage) Server 2012 R2 (64-bit). Therefore, in case of an upgrade scenario, MS SQL Server will remain on version 2017 and such combination is still supported with BVMS 11.0 and 11.1. However, for this reason it is not possible to deploy new BVMS 11.0 or 11.1 installation on Windows (Storage) Server 2012 R2, as MS SQL 2019 installation will fail.

5.5 DIVAR IP
The following BVMS versions are supported on the specific DIVAR IP devices.

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

39 | 139

DIVAR IP

Genera CTN tion

Operating System

Minimum BVMS version

Update method Remarks

AiO

1

5000

DIP-52x

Windows Server 2016 R2

BVMS 9.0

System Manager package

Installation of System Manager 2.1 required as prerequisite.

AiO

1

7000

DIP-72x

Windows Server 2016 R2

BVMS 9.0

System Manager package

Installation of System Manager 2.1 required as prerequisite.

AiO

2

7000

DIP-73x Windows Server 2019

BVMS 10.1.1

System Manager package

Upgrade from Software Center to System Manager required as prerequisite.

AiO

1

4000

DIP-44x Windows Server 2022

BVMS 11.1.1

System Manager package

AiO

1

6000

DIP-64x Windows Server 2022

BVMS 11.1.1

System Manager package

Since BVMS 11.1.1, no additional steps are required anymore when upgrading BVMS on a DIVAR IP. The only exception is DIVAR IP all-in-one 7000 Gen3, where dedicated Software Center package should be provided. Please refer to the document BVMS_on_DIVAR_IP_Version_Note published on https:// downloadstore.boschsecurity.com/?type=DIPBVMS

5.6 Hardware drivers

Component

Version

NVIDIA Quadro

NVIDIA RTX / Quadro Desktop and Notebook Driver Release 470 NVIDIA RTX / Quadro Desktop and Notebook Driver Release 500

Intel

Intel® Graphics – Windows® 10 DCH Drivers HD Graphics 530/ UHD Graphics

630

Hardware requirements
Bosch strongly urges customers to use the driver versions mentioned above. This ensures that the software can perform its task reliably and the specified performance (Recent Intel drivers show issues with H.265 decoding).

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

40 | 139

5.7 Virtualization

Manufacturer

Fail-over mode

Microsoft

Fail-over cluster

VMware

High availability

Version Windows Server 2022 (Hyper-V version 7) vSphere 6.0, 7.0

Hardware requirements The Video Recording Manager has an application specific fail-over mechanism that should be used. Virtualization-based fail-over mechanisms are not supported for the Video Recording Manager. The release notes of the Video Recording Manager provide information on the specific virtualization platforms that are supported considering this limitation.
Video Streaming Gateway If the VSG runs on a Hyper-V fail-over cluster, and the hardware fails, recording is stopped for ~30 seconds. Live streaming via the VSG might cause a small interruption.

5.8 Patched issues for BVMS 11.1.1
A patch solves a very specific issue. Do not hesitate to reach out to our technical support teams in case you are experiencing an issue that is not described in these release notes.

ID

Description

Fixed in BVMS

BVMS Viewer

382306 FIXED: Dragging camera from OC image pane to MG image pane 11.1.1 yes

n/a

390503, FIXED: Some SDK features not working correctly in the alarm

11.1.1 yes

yes

392474 scenario

5.9 Resolved issues

The table below lists the issues that are resolved from previous releases. If an issue is known, but not described as resolved, it will not be fixed and we have accepted it’s behavior.

ID

Description

368190

Camera

FIXED: Playback jumps during alarm recording with stream switching for CPP14 cameras. Resolved with fw: 8.50.0138

5.10 Known issues

Known issues
Known issues are inherited by previous versions. If an issue is fixed, it will appear in the list of resolved issues. The issue IDs can be used to relate an issue to a resolution.

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

41 | 139

ID 273546 319002 322846 323952 326773 334635 339032 345746 348893 351924 359472 359503 360387 366660 367142 367240 368140

Subject

Description

Operator Client

In some cases, playback of audio for cameras attached to DVR might be distorted.

Operator Client

An operator cannot restrict more than 10 slices per block for alarm recording.

Password

Change password dialog accepts a password with invalid characters but removes invalid characters of new passwords without any notification.

Microsoft Visual C++

In some cases, the installation of the Microsoft Visual C++ redistributable fails.

Security

No video when displaying a camera connected to XFM 1600 using SSH connection.

Operator Client

An OC showing GPU decoded cameos may run into an overload situation after a few hours as in some cases cameos may switch to CPU decoded mode.

Operator Client

Transcoding a cameo of a sequence does not use transcoded streams, but non- transcoded streams instead.

Operator Client

Timeline search might fail with very few alarms over a very long period of time for some devices.

Configuration Setting password enforcement does not work in some cases for CPP14

Client

cameras.

SQL Server

MS SQL Server update to 2019 silently fails on Windows Server 2012 R2 and stays on MS SQL Server 2017.

VSG

In some cases misleading “Configuration mismatch” information displayed

for VSG cameras, while system is fully operational.

Online maps

CPP3 based cameras moving into wrong direction when controlled from Online Maps.

Camera

CPP14 camera might not show live video under certain circumstances for lower resolution streams. To be resolved with the next firmware release.

Logbook

Alarm Title is cut off in Logbook after 64 characters.

DIVAR IP

‘Basic Config’ is not available for DIP-71 as iSCSI device from a remote server.

Camera

CPP14 might not always return to original fps when closing the second stream. To be resolved with firmware release.

Configuration Not all mounting position options available for configuration with CPP14.2

Client

cameras. As a workaround, Configuration Manager should be used.

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

42 | 139

ID 368190
369359 355155 371804 375281
375149 375596 377286 378184 378413
378719 379560 380121

Subject

Description

Camera

Playback jumps during alarm recording with stream switching for CPP13 and CPP14 cameras. To be resolved with the next firmware release.
Please note: as a workaround it is not recommended to configure switching streaming profiles during alarm recording for those camera platforms.

Operator Client

Using high resolution monitor with DIVAR IP all-in-one 5000 might result in improper scaling.

Keyboard

Keyboard connected to VJD-7513 decoder in BVMS environment is not supported yet.

Operator Client

Colored timeline: Depending on the timeline scale and number of events, loading of colored markings for events might take some time.

Camera

If using Bosch CPP13 or CPP14 based cameras, multicast stream is selfconfigured by the camera, even if not configured in the camera menu before. It might result in network issues if network infrastructure is not prepared for multicast. This issue is visible for fw 8.45.0017 or lower (CPP13), 8.30.0082 or lower (CPP14.1), 8.50.0138 or lower (CPP14.2). It is planned to be fixed with the next firmware release for respective platforms. As a mitigation, if network infrastructure is not prepared for multicast, it is strongly advised to switch to TCP streaming in the BVMS Operator Client or in the BVMS Configuration Client (as a workstation setting).

Configuration Performing factory default (“Restore settings”) for CPP13 cameras might

Client

result in BVMS Configuration Client crash.

Operator Client

Colored timeline: When importing block export video recordings, colored markings might exceed actual available recordings range.

Operator Client

Colored timeline: it might happen sporadically, that alarm recording indication extends between two consecutive alarms.

Configuration Occasionally, opening VRM Monitor page from BVMS Configuration Client

Client

results in displaying blank page.

Operator Client

If manually positioned timeline into the alarm period of recordings (after the moment when alarm started), Text Data might not be displayed properly for CPP13 or CPP14 cameras recordings. To be fixed with the next camera firmware release.

Operator Client

Colored timeline: Alarm recording markings might sporadically disappear and appear again after short period of time.

Operator Client

It might sporadically happen, that opening old recordings from the timeline results in jumping forward in time to more recent recordings.

Operator Client

Timeline event search for Motion and Alarm for DVR 600/700 recorders does not deliver results.

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

43 | 139

ID 380845 381138

Subject
Operator Client
MVS

Description
Colored timeline: when observing timeline with ongoing recording, it might sporadically happen, that colored markings exceed actual recording range.
CPP13 and CPP14 cameras might not work with Mobile Video Service

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

44 | 139

6 BVMS Version 11.1

This document is distributed within the installation package, but is updated from time to time. The latest version of the Release Notes is always available on the Bosch Security Systems Product Catalog. Version 11.1 introduces new features and resolves issues compared to BVMS 11.0

6.1 New functionality

ID

Description

193168

Online help documentation replaced to HTML5

199675

Multi-floor support for online maps

208390

New white style for Configuration Client

226896

New Person Identification solution – detect unauthorized and unknown persons

316840

Introduced REST API service for batch renaming of cameras

320241

New event timeline search in the recordings

320888

Changed licensing scheme to device-based

321208

Support 3rd camera stream for live view

323360

Live multicast encryption for decoders (UDP)

325610

Token-based authentication for Enterprise Access

326580

Adapt recording profile settings for CPP13 and CPP14 cameras

337698

Enable Multicast PIM-SSM support for ONVIF devices via VSG

347387

Support DIVAR IP deployment using standard setup

350389

Increase total limit of MJPEG framerate for VSG

352571

Allow presets call up for panoramic cameras using SDK

354961

Increased bandwidth limit for “Other” storage type

358393

Show number of connected subsystems and cameras in Enterprise OC

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

45 | 139

6.2 Removed functionality

ID

Description

257430

Removed routed access (port mapping)

6.3 Installation Notes
For system design specifications the BVMS architects and engineering specifications, system design guide and quick installation guide should be used. The BVMS upgrade guide helps you to upgrade an existing installation, and the BVMS security guide helps you to increase the security of your installation. The datasheet is subject to change. Translated versions are not published instantly; the English version is always up-to-date.
6.4 Versions
The table below lists the firmware versions which are used in the BVMS system test. When available, the version contains a clickable download link.
Device Compatibility
Up until some years ago, new released cameras, encoders, domes and decoders that were introduced into market after a BVMS release could not be connected to an existing BVMS version because these cameras where not known to the BVMS. In the BVMS 4.5.1, a new concept was introduced. This concept treats Bosch video encoders and decoders as generic devices, and automatically recognizes specific device functionality (for example the number of streams, relays and inputs). Based on this information the, at that time, unknown device is added to the system and can be used by the operator. This document, which can be found in the Bosch Building Technologies community, provides a detailed description of this functionality: BVMS – Device compatibility.

Component Camera firmware Firmware MPEG-4 Firmware CPP3 Firmware CPP4 Firmware CPP5 Firmware CPP6 Firmware CPP7 Firmware CPP7.3 Firmware CPP13

Version
4.15.0002 5.75.0011 7.10.0095 6.31.0010 7.83.0027 7.83.0027 7.83.0027 8.40.0029

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

Firmware CPP14.1 Firmware CPP14.2 Firmware Aviotec Firmware CPP-ENC Firmware CPP-ENC Firmware X1/X2 Decoder firmware VJD 7000 Videojet decoder 7000 Videojet decoder 8000 Barco RCP+ Agent Monitor Wall Software VRM VSG BIS Access Management System (AMS) Tracking and Recognition Service (TRS) Embedded components Web Client Intuikey Keyboard SQL Server BVMS Hardening Tool

8.30.0082 8.20.0143 7.82.0025 5.54.0012 5.97.0013 (for VJT XF E family, VIDEOJET decoder 3000) 2.53.0005
54.8.2 10.23.0002 10.05.0036 0.9.61 10.0 (pre-configured from Configuration Manager)
4.02.0014 (64-bit) 8.1.0.59 4.9.11200 4.9.10020
2.0.0.12
11.165 1.96 2019 11.1.0.8

46 | 139

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

ONVIF Event driver tool

2.0.0.8

VideoSDK

6.36.232

RCP+

5.02.0040

DVRs and other devices

DVR FW Version

2.6.0 (Divar AN 3000/5000) 3.2.0 (Divar Network/Hybrid)

Allegiant MCS

2.95

Cameo SDK

1.4.0.0

BVMS SDK

1.9.0.0

.NET framework

4.8

Bosch B- and G-Series Intrusion 3.12.020 Panel

NetApp E2800 SanTricity

11.70.1 R1

RPS

6.10.001

CMLib

7.51.0091

Operating systems

Operating systems Operator Client, Configuration Client

Windows 10 Professional (64-bit) (20H2) Windows 10 Professional (64-bit) (21H1) Windows 10 Professional (64-bit) (21H2) Windows 10 Enterprise (64-bit) LTSC build 1809

Operating systems Management Server, Mobile Video Service

Windows (Storage) Server 2012 R2 (64-bit)* Windows (Storage) Server 2016 (64-bit) Windows (Storage) Server 2019 (64-bit) Windows (Storage) Server 2022 (64-bit) Windows 10 Professional (64-bit) (20H2) Windows 10 Professional (64-bit) (21H1) Windows 10 Professional (64-bit) (21H2) Windows 10 Enterprise (64-bit) LTSC build 1809

47 | 139

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

48 | 139

Operating systems Video Recording Manager

Windows (Storage) Server 2012 R2 (64-bit) Windows (Storage) Server 2016 (64-bit) Windows (Storage) Server 2019 (64-bit)

*Windows (Storage) Server 2012 R2 (64-bit) is only supported when updating your BVMS from version 10.1 or lower. MS SQL Server 2019, used as a standard version for BVMS 11.0 and 11.1, is not supported anymore on Windows (Storage) Server 2012 R2 (64-bit). Therefore, in case of an upgrade scenario, MS SQL Server will remain on version 2017 and such combination is still supported with BVMS 11.0 and 11.1. However, for this reason it is not possible to deploy new BVMS 11.0 or 11.1 installation on Windows (Storage) Server 2012 R2, as MS SQL 2019 installation will fail.

6.5 DIVAR IP
The following BVMS versions are supported on the specific DIVAR IP devices.

DIVAR IP

Genera CTN tion

Operating System

Minimum BVMS version

Update method Remarks

AiO

1

5000

DIP-52x

Windows Server 2016 R2

BVMS 9.0

System Manager package

Installation of System Manager 2.1 required as prerequisite.

AiO

1

7000

DIP-72x

Windows Server 2016 R2

BVMS 9.0

System Manager package

Installation of System Manager 2.1 required as prerequisite.

AiO

2

7000

DIP-73x Windows Server 2019

BVMS 10.1.1

System Manager package

Upgrade from Software Center to System Manager required as prerequisite.

AiO

1

4000

DIP-44x Windows Server 2022

BVMS 11.1.1

System Manager package

AiO

1

6000

DIP-64x Windows Server 2022

BVMS 11.1.1

System Manager package

Since BVMS 11.1, no additional steps are required anymore when upgrading BVMS on a DIVAR IP. The only exception is DIVAR IP all-in-one 7000 Gen3, where dedicated Software Center package should be provided. Please refer to the document BVMS_on_DIVAR_IP_Version_Note published on https:// downloadstore.boschsecurity.com/?type=DIPBVMS

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

49 | 139

6.6 Hardware drivers

Component

Version

NVIDIA Quadro

NVIDIA RTX / Quadro Desktop and Notebook Driver Release 470 NVIDIA RTX / Quadro Desktop and Notebook Driver Release 500

Intel

Intel® Graphics – Windows® 10 DCH Drivers HD Graphics 530/ UHD Graphics

630

Hardware requirements
Bosch strongly urges customers to use the driver versions mentioned above. This ensures that the software can perform its task reliably and the specified performance (Recent Intel drivers show issues with H.265 decoding).

6.7 Virtualization

Manufacturer

Fail-over mode

Microsoft

Fail-over cluster

VMware

High availability

Version Windows Server 2022 (Hyper-V version 7) vSphere 6.0, 7.0

Hardware requirements The Video Recording Manager has an application specific fail-over mechanism that should be used. Virtualization-based fail-over mechanisms are not supported for the Video Recording Manager. The release notes of the Video Recording Manager provide information on the specific virtualization platforms that are supported considering this limitation.
Video Streaming Gateway If the VSG runs on a Hyper-V fail-over cluster, and the hardware fails, recording is stopped for ~30 seconds. Live streaming via the VSG might cause a small interruption.

6.8 Patched issues for BVMS 11.1

A patch solves a very specific issue. Do not hesitate to reach out to our technical support teams in case you are experiencing an issue that is not described in these release notes.

ID

Description

Fixed in BVMS

BVMS Viewer

n/a

n/a

n/a

n/a

n/a

6.9 Resolved issues
The table below lists the issues that are resolved from previous releases. If an issue is known, but not described as resolved, it will not be fixed and we have accepted it’s behavior.

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

50 | 139

ID 249915 254839 257032 284238 326208 329891
334228 353966

Description Export Maps VSG Operator Client License Manager Operator Client
DVR Operator Client

FIXED: In rare occasions an export might hang when trying to export video and audio into an MP4 file.
FIXED: The zoom-level of maps in the Operator Client differs from the default zoom-level in the Configuration Client.
FIXED: The monitor group control shows a connection loss icon for ONVIF cameras, even though the cameras are online.
FIXED: Jump to next or previous event does not always work
FIXED: Non-ASCII characters might not be displayed correctly in License Manager
FIXED: ATM/Text data might not be displayed correctly in the image pane during playback when using camera with fw 7.80. In such cases it is recommended to use fw 7.60 instead
(Obsolete) For some cameras connected to a DVR (3000, 2000) button ‘jump to oldest recording’ does not work properly
FIXED: Export recordings dialog window does not allow modifying specific export start/end time.

6.10 Known issues

Known issues
Known issues are inherited by previous versions. If an issue is fixed, it will appear in the list of resolved issues. The issue IDs can be used to relate an issue to a resolution.

ID 273546 319002 322846 323952 326773

Subject
Operator Client
Operator Client
Password
Microsoft Visual C++
Security

Description In some cases, playback of audio for cameras attached to DVR might be distorted. An operator cannot restrict more than 10 slices per block for alarm recording.
Change password dialog accepts a password with invalid characters but removes invalid characters of new passwords without any notification. In some cases, the installation of the Microsoft Visual C++ redistributable fails.
No video when displaying a camera connected to XFM 1600 using SSH connection.

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

51 | 139

ID 334635 339032 345746 348893 351924 359472 359503 360387 366660 367142 367240 368140 368190
369359

Subject

Description

Operator Client

An OC showing GPU decoded cameos may run into an overload situation after a few hours as in some cases cameos may switch to CPU decoded mode.

Operator Client

Transcoding a cameo of a sequence does not use transcoded streams, but non- transcoded streams instead.

Operator Client

Timeline search might fail with very few alarms over a very long period of time for some devices.

Configuration Setting password enforcement does not work in some cases for CPP14

Client

cameras.

SQL Server

MS SQL Server update to 2019 silently fails on Windows Server 2012 R2 and stays on MS SQL Server 2017.

VSG

In some cases misleading “Configuration mismatch” information displayed

for VSG cameras, while system is fully operational.

Online maps

CPP3 based cameras moving into wrong direction when controlled from Online Maps.

Camera

CPP14 camera might not show live video under certain circumstances for lower resolution streams. To be resolved with the next firmware release.

Logbook

Alarm Title is cut off in Logbook after 64 characters.

DIVAR IP

‘Basic Config’ is not available for DIP-71 as iSCSI device from a remote server.

Camera

CPP14 might not always return to original fps when closing the second stream. To be resolved with firmware release.

Configuration Not all mounting position options available for configuration with CPP14.2

Client

cameras. As a workaround, Configuration Manager should be used.

Camera

Playback jumps during alarm recording with stream switching for CPP13 and CPP14 cameras. To be resolved with the next firmware release.
Please note: as a workaround it is not recommended to configure switching streaming profiles during alarm recording for those camera platforms.

Operator Client

Using high resolution monitor with DIVAR IP all-in-one 5000 might result in improper scaling.

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

52 | 139

7

BVMS Version 11.0

This document is distributed within the installation package, but is updated from time to time. The latest version of the Release Notes is always available on the Bosch Security Systems Product Catalog. Version 11.0 introduces new features and resolves issues compared to BVMS 10.1.1

7.1 New functionality

ID

Description

250378

Introduction of the Map-based tracking assistant for live and playback cameras (Bosch and ONVIF cameras)

242826

Introduction of the use of online GIS maps (HERE) with new camera icons and view cones

206391

Introduction of new licensing with the Bosch Remote Portal as new user interface

261465

New RCP+ events (NTP lost and SD life)

233893

Support of generic event as peak event from the VSG

256342

Automatic event message in the BVMS operating client when a camera is losing recording

183249

Configurable file size split for exported video

231473

Introduce panoramic dewarping mode in the BVMS CameoSDK

280378

Events for quality assurance reports

237358

Enable a global CHAP password (secure devices) for devices in the system

193353

Automatic health monitoring for DIVAR IP devices via SNMP

266215

Restrict and unrestrict video capabilities for VRM devices

7.2 Removed functionality

ID

Description

261466

Removed map migration

268550

Removed SMS gateway

198093

Removed digital monitor wall functionality

268674

Removed PIS (Protection Inspection Service) functionality

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

53 | 139

ID 249424 222022

Description Removed ASF export from BVMS SDK Removed Dibos / BRS functionality

7.3 Installation Notes
For system design specifications the BVMS architects and engineering specifications, system design guide and quick installation guide should be used. The BVMS upgrade guide helps you to upgrade an existing installation, and the BVMS security guide helps you to increase the security of your installation. The datasheet is subject to change. Translated versions are not published instantly; the English version is always up-to-date.
7.4 Versions
The table below lists the firmware versions which are used in the BVMS system test. When available, the version contains a clickable download link.
Device Compatibility
Up until some years ago, new released cameras, encoders, domes and decoders that were introduced into market after a BVMS release could not be connected to an existing BVMS version because these cameras where not known to the BVMS. In the BVMS 4.5.1, a new concept was introduced. This concept treats Bosch video encoders and decoders as generic devices, and automatically recognizes specific device functionality (for example the number of streams, relays and inputs). Based on this information the, at that time, unknown device is added to the system and can be used by the operator. This document, which can be found in the Bosch Building Technologies community, provides a detailed description of this functionality: BVMS – Device compatibility.

Component Camera firmware Firmware MPEG-4 Firmware CPP3 Firmware CPP4 Firmware CPP5 Firmware CPP6 Firmware CPP7 Firmware CPP7.3 Firmware CPP13 Firmware Aviotec

Version
4.15.0002 5.75.0011 7.10.0076 6.31.0010 7.80.0128 7.80.0128 7.80.0128 7.75.0006 7.61.0023

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

Firmware CPP-ENC Firmware CPP-ENC Firmware X1/X2 Decoder firmware VJD 7000 Videojet decoder 7000/8000 Barco RCP+ Agent Monitor Wall Software VRM VSG BIS Access Management System (AMS) Tracking and Recognition Service (TRS) Embedded components iOS Web Client Intuikey Keyboard SQL Server BVMS Hardening Tool ONVIF Event driver tool VideoSDK RCP+

5.54.0012 5.97.0013 (for VJT XF E family, VIDEOJET decoder 3000) 2.53.0005
54.8.2 10.01.0036 0.9.6.1 10.0 (pre-configured from Configuration Manager)
4.00.0070 (64-bit), 04.01.0012 (64-bit) 8.0.0.155, 8.0.6.1 4.8.10900 3.0.1
2.0.0.12
13.0 11.165 1.96 2019 11.0.0.9 2.0.0.8 6.36.220 5.01.0030

54 | 139

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

55 | 139

DVRs and other devices

DVR FW Version

2.6.0 (Divar AN 3000/5000) 3.1.0 (Divar Network/Hybrid)

Allegiant MCS

2.94 / 2.95

Cameo SDK

1.4.0.0

BVMS SDK

1.9.0.0

.NET framework

4.8

Bosch B- and G-Series Intrusion 3.10.034 Panel

NetApp E2800 SanTricity

11.70R2

RPS

6.10.001

CMLib

7.41.0075

Operating systems

Operating systems Operator Client, Configuration Client

Windows 10 Professional (64-bit) October 2020 update (20H2) Windows 10 Professional (64-bit) April 2020 update (2004) Windows 10 Enterprise (64-bit) LTSC build 1809

Operating systems Management Server, Mobile Video Service

Windows (Storage) Server 2012 R2 (64-bit) Windows (Storage) Server 2016 (64-bit) Windows (Storage) Server 2019 (64-bit) Windows 10 Professional (64-bit) October 2020 update (20H2) Windows 10 Professional (64-bit) April 2020 update (2004) Windows 10 Enterprise (64-bit) LTSC build 1809

Operating systems Video Recording Manager

Windows (Storage) Server 2012 R2 (64-bit) Windows (Storage) Server 2016 (64-bit) Windows (Storage) Server 2019 (64-bit)

7.5 DIVAR IP
The following BVMS versions are supported on the specific DIVAR IP devices.

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

56 | 139

DIVAR IP

Genera CTN tion

Operating System

Minimum BVMS version

Update method Remarks

AiO

1

5000

DIP-52x

Windows Server 2016 R2

BVMS 9.0

System Manager package

Installation of System Manager 2.1 required as prerequisite.

AiO

1

7000

DIP-72x

Windows Server 2016 R2

BVMS 9.0

System Manager package

Installation of System Manager 2.1 required as prerequisite.

AiO

2

7000

DIP-73x Windows Server 2019

BVMS 10.1.1

System Manager package

Upgrade from Software Center to System Manager required as prerequisite.

AiO

1

4000

DIP-44x Windows Server 2022

BVMS 11.1.1

System Manager package

AiO

1

6000

DIP-64x Windows Server 2022

BVMS 11.1.1

System Manager package

When you upgrade BVMS on a DIVAR IP, additional steps are needed to complete the upgrade. Please refer to the document BVMS_on_DIVAR_IP_Version_Note published on https:// downloadstore.boschsecurity.com/?type=DIPBVMS

7.6 Hardware drivers

Component

Version

NVIDIA Quadro

NVIDIA RTX / Quadro Desktop and Notebook Driver Release 460

Intel

Intel Graphics Driver for Windows 10 (64bit) – 4600 GPU – 26.20.100.7870

(2020-02-19)

Intel

Intel® Graphics – Windows® 10 DCH Drivers HD Graphics 530/ UHD Graphics

630

Hardware requirements
Bosch strongly urges customers to use the driver versions mentioned above. This ensures that the software can perform its task reliably and the specified performance (Recent Intel drivers show issues with H.265 decoding).

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

57 | 139

7.7 Virtualization

Manufacturer

Fail-over mode

Microsoft

Fail-over cluster

VMware

High availability

Version Windows Server 2016 (Hyper-V version 7) vSphere 6.0

Hardware requirements The Video Recording Manager has an application specific fail-over mechanism that should be used. Virtualization-based fail-over mechanisms are not supported for the Video Recording Manager. The release notes of the Video Recording Manager provide information on the specific virtualization platforms that are supported considering this limitation.
Video Streaming Gateway If the VSG runs on a Hyper-V fail-over cluster, and the hardware fails, recording is stopped for ~30 seconds. Live streaming via the VSG might cause a small interruption.

7.8 Patched issues for BVMS 11.0
A patch solves a very specific issue. Do not hesitate to reach out to our technical support teams in case you are experiencing an issue that is not described in these release notes.

ID

Description

Fixed in BVMS

BVMS Viewer

355270 FIXED: Export to MOV and MP4 from old devices (VIP X1, CPP3, …) 11.1

Yes

Yes

might lead to split images.

354548 FIXED: Configuration Client alarm settings are sometimes visible 11.1

Yes

Yes

for events not having an alarm after activating iSCSI Monitoring.

358822 FIXED: SDK method GetScheduleStateTransitions providing wrong calculation for different time zones.

11.1

Yes

Yes

349597 FIXED: Device configuration of camera Flexidome IP 8000i not

11.1.1 Yes

No

368355 supported in BVMS.

374266 FIXED: Forensic Search not working properly after installation of

patch 349597.

FIXED: License source was set incorrectly, which might lead to

problem with software licensing.

377531 FIXED: Video not displayed correctly during 8x playback

12.0

Yes

Yes

354124 backwards.

FIXED: Some characters not displayed properly in Forensic Search

view.

357258 FIXED: Image saved using CameoSDK contains additional text and 11.1.1 Yes

Yes

properties.

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

58 | 139

ID

Description

Fixed in BVMS

350403 FIXED: (CVE-2021-23859) Resolved security issue.

11.1

Yes

350341 FIXED: Universal XF Keyboard not working correctly in EMS mode. 11.1

Yes

356020 FIXED: Using Intui Keyboard in EMS to control Monitor Group,

which is not support, leads to internal error.

346015 FIXED: Setting the reference image sensitive area in Operator Client not saved correctly.

11.1

Yes

339917 FIXED: Operator Client crash in Enterprise, when Management

11.1

Yes

336777 Server is offline and credentials have been changes

FIXED: Operator Client random crashes.

346573 FIXED: In some cases black pane is displayed in alarm.

11.1

Yes

353965 Combined patch to support CPP14.1 and CPP14.2 cameras in

11.1.1 Yes

353995 BVMS 11.0.

337415 343590 343170 360438 357751

FIXED: Wrong calculation of active platform for CPP14 cameras. FIXED: Incorrect encoder profiles are set for CPP14 cameras. FIXED: General support of Flexidome IP multi 7000i and Flexidome IP panoramic 5100i cameras. FIXED: BVMS Operator Client crash during login.

FIXED: Error adding a camera while previous camera is offline and

large LUN support is enabled.

FIXED: Device Monitor might show device config mismatch when

triggering alarm recording.

FIXED: Inconsistent state of recording profiles set for CPP14

cameras.

346819 FIXED: System slowdown when configuring events and alarms.

11.1

Yes

BVMS Viewer Yes No Yes No Yes No
No

Hotfixes related to specific Security Advisory, are marked with Assigned CVE ID. However, not every Security Advisory results in a hotfix or patch created. Please always refer to detailed description of Security Advisories, available on Bosch PSIRT Security Advisories webpage, where additional explanations or mitigation steps might be described.

7.9 Resolved issues
The table below lists the issues that are resolved from previous releases. If an issue is known, but not described as resolved, it will not be fixed and we have accepted it’s behavior.

ID

Description

273523

Alarm management FIXED: BVMS Enterprise alarms are always presented as multi- rows alarms in the operator client.

272951

INTEOX

FIXED: Backward compatibility issues for 10.01, 10.0.0 and 9.0

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

59 | 139

ID 275714 275914
276500 320195

Description Person Identification Person Identification
SDK
VRM

FIXED: The order of the logical tree in the Person Identification configuration differs from the order of the logical tree configuration.
FIXED: Empty (grey) pictures are shown when the TRS is unavailable while new persons are added using the manage persons dialogue. There is no indication the TRS is unavailable. Workaround: re-open the dialogue.
FIXED: CameraManager.StartAlarmRecording parameters “protect”, “alarmId” and “metadata” do not work.
FIXED: The error message ‘could not configure the connection between Failover VRM and its Master VRM’ may appear after adding a new failover VRM to the Master

7.10 Known issues

Known issues
Known issues are inherited by previous versions. If an issue is fixed, it will appear in the list of resolved issues. The issue IDs can be used to relate an issue to a resolution.

ID 279257 319002 334635 335190 334228 322846 284238 332788

Subject
Operator Client
Operator Client
Operator Client
Ports
DVR
Password
Operator Client
Restricted Video

Description In some cases, recording monitor state events are coming with a delay
An operator cannot restrict more than 10 slices per block for alarm recording
An OC showing GPU decoded cameos may run into an overload situation after a few hours as in some cases cameos may switch to CPU decoded mode The new firewall rules no longer include the RCP+ ports 1756 and 1757 For some cameras connected to a DVR (3000, 2000) button ‘jump to oldest recording’ does not work properly Change password dialog accepts a password with invalid characters but removes invalid characters of new passwords without any notification Jump to next or previous event does not always work
Restricted video from CPP3 cameras is played in playback mode via a transcoding stream if the user has no restrict permission

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

60 | 139

ID 315917
323952 326149
319020 326208 326773 329891

Subject
Map-based tracking assistant
Microsoft Visual C++
MVS
Restricted video
License Manager
Security
Operator Client

Description
CPP3 and CPP4 for devices cannot be used in the map-based tracking assistant when configured via ONVIF using HTTPS
In some cases, the installation of the Microsoft Visual C++ redistributable fails
Taking away live view permissions for a camera in the BVMS configuration client might lead to an access denied error in MVS for playback as well. As a workaround, you need to drag and drop the camera again.
Restricted video cannot be exported via remote export for enterprise users
Non-ASCII characters might not be displayed correctly in License Manager
No video when displaying a camera connected to XFM 1600 using SSH connection
ATM/Text data might not be displayed correctly in the image pane during playback when using camera with fw 7.80. In such cases it is recommended to use fw 7.60 instead

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

61 | 139

8 BVMS Version 10.1.1
This document is distributed within the installation package, but is updated from time to time. The latest version of the Release Notes is always available on the Bosch Security Systems Product Catalog.
Version 10.1.1 is Technical Update release only. It doesn’t introduce any new features compared to BVMS 10.1 and there are no changes in technical requirements. Please follow to BVMS 10.1 Release Notes below.

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

62 | 139

9 BVMS Version 10.1

This document is distributed within the installation package, but is updated from time to time. The latest version of the Release Notes is always available on the Bosch Security Systems Product Catalog. Version 10.1 introduces new features and resolves issues compared to BVMS 10.0.1.

9.1 New functionality

ID

Description

246759

Enable/disable audio export

232670

Integrate Tattile LPR camera to facilitate forensic search on license plates

229434

Several small enhancements for the BVMS – AMS 3.0 integration

226866

200 Person identification cameras per BVMS management server

264520

Remove DIP specific Firewall rules from setup

108245

BVMS Management server acts as bridge between video and corporate network

204308

SSH access in Enterprise environment

255109

LDAP group priorities – multi group membership (customer specific implementation)

244915

Single-Sign-On based on LDAP

269032

Prepare BVMS for Bosch Inteox (CPP13) cameras

9.2 Installation Notes
For system design specifications the BVMS architects and engineering specifications, system design guide and quick installation guide should be used. The BVMS upgrade guide helps you to upgrade an existing installation, and the BVMS security guide helps you to increase the security of your installation. The datasheet is subject to change. Translated versions are not published instantly; the English version is always up-to-date.
9.3 Versions
The table below lists the firmware versions which are used in the BVMS system test. When available, the version contains a clickable download link.

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

63 | 139

Device Compatibility
Up until some years ago, new released cameras, encoders, domes and decoders that were introduced into market after a BVMS release could not be connected to an existing BVMS version because these cameras where not known to the BVMS. In the BVMS 4.5.1, a new concept was introduced. This concept treats Bosch video encoders and decoders as generic devices, and automatically recognizes specific device functionality (for example the number of streams, relays and inputs). Based on this information the, at that time, unknown device is added to the system and can be used by the operator. This document, which can be found in the Bosch Building Technologies community, provides a detailed description of this functionality: BVMS – Device compatibility.

Component Camera firmware Firmware MPEG-4 Firmware CPP3 Firmware CPP4 Firmware CPP5 Firmware CPP6 Firmware CPP7 Firmware CPP7.3 Firmware CPP13 Firmware Aviotec Firmware CPP-ENC Firmware CPP-ENC Firmware X1/X2 Decoder firmware VIP XD HD VIP XD VJD 7000 Videojet decoder 7000/8000 Barco RCP+ Agent

Version
4.15.0002 5.75.0011 7.10.0076 6.31.0010 7.61.0023 7.61.0023 7.61.0023 7.70.0052 7.61.0023 5.54.0012 5.97.0013 (for VJT XF E family, VIDEOJET decoder 3000) 2.53.0005
1.8 4.10.056 54.8.2 (click to download) 9.60.0017 (click to download) 0.9.6.1

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

64 | 139

Monitor Wall Software VRM VSG BIS Access Management System (AMS) BRS Tracking and Recognition Service (TRS) Embedded components iOS Web Client Intuikey Keyboard SQL Server BVMS Hardening Tool ONVIF Event driver tool VideoSDK RCPP DVRs DiBos DVR FW Version
Allegiant MCS Cameo SDK

10.0 (pre-configured from Configuration Manager)
3.83.0021 (64-bit) 7.2.0.44 4.6.x, 4.7.x 3.0
8.10/8.11 2.0.0.12
13.0 11.165 1.96 2017 10.1.0.2 1.1.0.22 6.34.0184 4.64.70
8.7 2.1.3 (DVR400 / 600) 3.61 (DIVAR 700) 2.6.0 (Divar AN 3000/5000) 3.1.0 (Divar Network/Hybrid) 2.94 / 2.95 1.3.0.0

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

65 | 139

BVMS SDK .NET framework Operating systems Operating systems Operator Client, Configuration Client
Operating systems Management Server, Mobile Video Service
Operating systems Video Recording Manager

1.9.0.0
4.8
Windows 10 Professional (64-bit) April 2020 update (2004) Windows 10 Professional (64-bit) November 2019 update (1909) Windows 10 Enterprise (64-bit) LTSC build 1809
Windows (Storage) Server 2012 R2 (64-bit) Windows (Storage) Server 2016 (64-bit) Windows (Storage) Server 2019 (64-bit) Windows 10 Professional (64-bit) April 2020 update (2004) Windows 10 Professional (64-bit) November 2019 update (1909) Windows 10 Enterprise (64-bit) LTSC build 1809
Windows (Storage) Server 2012 R2 (64-bit) Windows (Storage) Server 2016 (64-bit) Windows (Storage) Server 2019 (64-bit)

9.4 DIVAR IP
The following BVMS versions are supported on the specific DIVAR IP devices.

DIVAR IP

Genera CTN tion

Operating System

Minimum BVMS version

Update method Remarks

AiO

1

5000

DIP-52x

Windows Server 2016 R2

BVMS 9.0

System Manager package

Installation of System Manager 2.1 required as prerequisite.

AiO

1

7000

DIP-72x

Windows Server 2016 R2

BVMS 9.0

System Manager package

Installation of System Manager 2.1 required as prerequisite.

AiO

2

7000

DIP-73x Windows Server 2019

BVMS 10.1.1

System Manager package

Upgrade from Software Center to System Manager required as prerequisite.

AiO

1

4000

DIP-44x Windows Server 2022

BVMS 11.1.1

System Manager package

AiO

1

6000

DIP-64x Windows Server 2022

BVMS 11.1.1

System Manager package

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

66 | 139

When you upgrade a DIVAR IP to BVMS 10.1, additional steps might be needed to complete the upgrade. Please refer to the knowledge base for the latest articles, which helps you to do the upgrade.

9.5 Hardware drivers

Component

Version

NVIDIA Quadro

Quadro Pro Driver for Microsoft Windows 10 (64-Bit) 442.50 (February 2020)

Intel

Intel Graphics Driver for Windows 10 (64bit) – 4600 GPU – 26.20.100.7870

(2020-02-19)

Intel

Intel Graphics Driver for Windows 10 (64bit) – 530 GPU – 26.20.100.7870

(2020-02-19)

Hardware requirements
Bosch strongly urges customers to use the driver versions mentioned above. This ensures that the software can perform its task reliably and the specified performance (Recent Intel drivers show issues with H.265 decoding).

9.6 Virtualization

Manufacturer

Fail-over mode

Microsoft

Fail-over cluster

VMware

High availability

Version Windows Server 2016 (Hyper-V version 7) vSphere 6.0

Hardware requirements The Video Recording Manager has an application specific fail-over mechanism that should be used. Virtualization-based fail-over mechanisms are not supported for the Video Recording Manager. The release notes of the Video Recording Manager provide information on the specific virtualization platforms that are supported considering this limitation.
Video Streaming Gateway If the VSG runs on a Hyper-V fail-over cluster, and the hardware fails, recording is stopped for ~30 seconds. Live streaming via the VSG might cause a small interruption.

9.7 Patched issues for BVMS 10.1
A patch solves a very specific issue. Do not hesitate to reach out to our technical support teams in case you are experiencing an issue that is not described in these release notes.

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

67 | 139

ID

Description

283619 FIXED: Allegiant CCL Emulation commands causing system instability

317617 FIXED: Occasional black screens during playback mode

313844 FIXED: PTZ for camera connected to Dibos 8.7 not working

316150 FIXED: OC client filter box issues

281029, FIXED: OC login IP Address missing drag & drop information not 283149 completely encrypted
320037 FIXED: OC 10.1 stuck at alarm handling

Fixed in BVMS

BVMS Viewer

11.0

Link to n/a

Downlo

adstore

11.0

Link to Link to

Downlo Downlo

adstore adstore

11.0

Link to Link to

Downlo Downlo

adstore adstore

11.0

Link to Link to

Downlo Downlo

adstore adstore

10.1.1

Link to Downlo adstore

Link to Downlo adstore

11.0

Link to Link to

Downlo Downlo

adstore adstore

9.8 Resolved issues

The table below lists the issues that are resolved from previous releases. If an issue is known, but not described as resolved, it will not be fixed and we have accepted it’s behaviour.

ID

Description

262502

FIXED: The “Cancel” button in the export dialogue does not change to “Done” when the export has finished.

243256

FIXED: Cameras with empty passwords cannot be added to a person identification device (TRS).

239129 / 239222

FIXED: The ONVIF camera needs to be on-line and accessible when it is added to the BVMS configuration.

9.9 Known issues

Known issues
Known issues are inherited by previous versions. If an issue is fixed, it will appear in the list of resolved issues. The issue IDs can be used to relate an issue to a resolution.

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

68 | 139

ID 273379
268428
276500 273523 269038
274173 274904 / 272951 269970 274743 267100
269632 266124
276385 275914

Subject

Description

Windows

Windows 10 build 1607 causes, in some situations, an issue that results in missing visual elements in the Operator Client. Please upgrade your Windows version.

Transcoding

In some scenarios the Operator Client might crash when using a combination of custom display scaling (for example, 129%) and looking at transcoded video.

SDK

CameraManager.StartAlarmRecording parameters “protect”, “alarmId” and

“metadata” do not work.

Alarm

BVMS Enterprise alarms are always presented as multi-rows alarms in the

management operator client.

Configuration Client

Configuration Client IP grayed out after BVMS is de-installed and BVMS Viewer is installed. Work-around: clear the registry entries in ComputerHKEY_CURRENT_USERSoftwareBosch Sicherheitssysteme GmbH

Configuration “Import configuration from VRM” does not import the name of the added

Client

iSCSI devices. Work-around: manually configure the iSCSI name.

Cameras

Encrypted multicast is not working for Inteox (CPP13) cameras. We are planning to fix this with camera FW version 7.80.

Person

There is no indication if the BVMS Configuration Client fails to add an edge

Identification TRS to the configuration.

Help

In rare situations the BVMS Operator Client might crash while browsing the

build-in help sections.

Security

After changing the password on a Tattile camera, and BVMS generates an authentication failure, BVMS still receives LPR detection events from the camera. Work-around: remove the BVMS Management Server as event receiver from the camera configuration.

Security

SSH connectivity does not work for users with an empty password. We don’t recommend using accounts that have an empty password.

Person Identification

When the central server starts up the first connection to a TRS causes a disconnect error. This error produces per default a disconnect alarm for the TRS visible within the OpClient alarm list. After 5 sec the central server reconnects to the TRS. This time the connection is successful.

Person

There is no overview which shows the cameras that are assigned to a specific

Identification (core/edge) TRS.

Person Identification

Empty (grey) pictures are shown when the TRS is unavailable while new persons are added using the manage persons dialogue. There is no indication the TRS is unavailable. Workaround: re-open the dialogue.

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

69 | 139

ID 264269 266945 256523 276429 257445 277300 271949 275222 275714

Subject

Description

Configuration Config Wizard crashes when pasting password of encoder. Wizard

Export

Space check of DVD happens after export to temp folder.

Resilience

A fail-over VRM might take up to 30 seconds to build-up the timeline, even when the recorded video is already visible in the image pane.

ANR

It is not possible to associate the recordings of a replaced ANR camera with a

new ANR camera.

Security

Encrypted video that is exported using the VRM eXport Wizard cannot be replayed and results in a black image pane.

Security

Direct iSCSI playback is not working over SSH. The system will automatically fall-back to VRM playback.

Security

LDAP does not work with SSH when the password contains an umlaut.

Security

Connecting via SSH to an unmanaged site using LDAP authentication to the site is not working.

Person

The order of the logical tree in the Person Identification configuration differs

Identification from the order of the logical tree configuration.

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

70 | 139

10 BVMS Version 10.0.2
This document is distributed within the installation package, but is updated from time to time. The latest version of the Release Notes is always available on the Bosch Security Systems Product Catalog.
Version 10.0.2 is Technical Update release only. It doesn’t introduce any new features compared to BVMS 10.0.1 and there are no changes in technical requirements. Please follow to BVMS 10.0.1 Release Notes below.

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

71 | 139

11 BVMS Version 10.0.1

This document is distributed within the installation package, but is updated from time to time. The latest version of the Release Notes is always available on the Bosch Security Systems Product Catalog. Version 10.0.1 introduces new features and resolves issues compared to BVMS 10.0. BVMS 10.0 is not available for download any longer.

11.1 New functionality

ID

Description

183538

Facelift for Timeline Control

174546

Operator Client and Configuration Client shall support High resolution screens

229915

Encrypted multicast from VSG to OC

193007

Export player should not have to be installed

218193

50 Monitor Groups per MS

206566

SDK applications are subjected to device permissions

172117

Automatically configure firewall during BVMS setup

201942

BVMS should not crash when FIPS-140 is enabled (Windows setting)

223693

Disable audio recording while intercom is enabled

242567

Upgrade SDK environment to .NET version 4.8

226895

Dewarping pre-set for panoramic cameras can be activated in the operator client in an alarm scenario

205515

Dewarping pre-set for panoramic cameras can be activated on a decoder in an alarm scenario

240228

Enable IVA overlays by default in alarm scenario

180405

Enable the use of PDF and PNG/JPG maps

245699

Import BVC native exports for Forensic Search

228629

ONVIF Camera Event Driver Tool

160518

General UX improvements for Forensic Search

235594

MP4 as export format, removed ASF export format

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

72 | 139

ID 252110
207733 243681 238163 245238 256819

Description Do not change server ID on export of configuration (to enable the export and import of user settings) Get capabilities from devices in batch Switch between ONVIF Profile S/T on camera level Handle brute-force attack in a gracefull manner with a time-out mechanism Audio event from Bosch cameras Enhanced security for sensitive configuration data

11.2 Installation Notes
For system design specifications the BVMS architects and engineering specifications, system design guide and quick installation guide should be used. The BVMS upgrade guide helps you to upgrade an existing installation, and the BVMS security guide helps you to increase the security of your installation. The datasheet is subject to change. Translated versions are not published instantly; the English version is always up-to-date.
11.3 Versions
The table below lists the firmware versions which are used in the BVMS system test. When available, the version contains a clickable download link.
Device Compatibility
Up until some years ago, new released cameras, encoders, domes and decoders that were introduced into market after a BVMS release could not be connected to an existing BVMS version because these cameras where not known to the BVMS. In the BVMS 4.5.1, a new concept was introduced. This concept treats Bosch video encoders and decoders as generic devices, and automatically recognizes specific device functionality (for example the number of streams, relays and inputs). Based on this information the, at that time, unknown device is added to the system and can be used by the operator. This document, which can be found in the Bosch Building Technologies community, provides a detailed description of this functionality: BVMS – Device compatibility.

Multicast issue with camera firmware 7.60.0118
Issue 257256 prevents camera firmware to work in a multicast environment. This issue can be observed when you combine BVMS 10.0.1 and earlier BVMS versions with firmware 7.60.x. Firmware 7.61.0023 solves this issue.

Component Camera firmware Firmware MPEG-4 Firmware CPP3

Version
4.15.0002 5.75.0011

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

Firmware CPP4 Firmware CPP5 Firmware CPP6 Firmware CPP7 Firmware CPP7.3 Firmware Aviotec Firmware CPP-ENC Firmware CPP-ENC Firmware X1/X2 Decoder firmware VIP XD HD VIP XD VJD 7000 Videojet decoder 7000/8000 Barco RCP+ Agent Monitor Wall Software VRM VSG BIS Access Management System (AMS) BRS Tracking and Recognition Service (TRS)

7.10.0076 6.31.0010 7.60.0118, 7.61.0023 7.60.0118, 7.61.0023 7.60.0118, 7.61.0023 7.50.0079, 7.61.0023 5.54.0012 5.97.0013 (for VJT XF E family, VIDEOJET decoder 3000) 2.53.0005
1.8 4.10.056 54.8.2 (click to download) 9.60.0017 (click to download) 0.9.6.1 8.0
3.82.0052 (64-bit) 7.1.0.43 (ONVIF VDP 3.0.4.0) 4.6.x, 4.7.x n/a
8.10/8.11 1.0

73 | 139

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

74 | 139

Embedded components iOS Web Client Intuikey Keyboard SQL Server BVMS Hardening Tool ONVIF Event driver tool VideoSDK RCPP DVRs DiBos DVR FW Version
Allegiant MCS Cameo SDK BVMS SDK .NET framework Operating systems Operating systems Operator Client, Configuration Client
Operating systems Management Server, Mobile Video Service

13.0 11.165 1.96 2017 1.83.0 1.0.0.202 6.34.0184 4.64.70
8.7 2.1.3 (DVR400 / 600) 3.61 (DIVAR 700) 2.6.0 (Divar AN 3000/5000) 3.1.0 (Divar Network/Hybrid) 2.94 / 2.95 1.3.0.0 1.9.0.0 4.8
Windows 10 Professional (64-bit) November 2019 update (1909) Windows 10 Professional (64-bit) May 2019 update (1903) Windows 10 Enterprise (64-bit) LTSC build 1809 Windows (Storage) Server 2012 R2 (64-bit) Windows (Storage) Server 2016 (64-bit) Windows (Storage) Server 2019 (64-bit) Windows 10 Professional (64-bit) November 2019 update (1909) Windows 10 Professional (64-bit) May 2019 update (1903) Windows 10 Enterprise (64-bit) LTSC build 1809

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

75 | 139

Operating systems Video Recording Manager

Windows (Storage) Server 2012 R2 (64-bit) Windows (Storage) Server 2016 (64-bit) Windows (Storage) Server 2019 (64-bit)

11.4 DIVAR IP
The following BVMS versions are supported on the specific DIVAR IP devices.

DIVAR IP

Genera CTN tion

Operating System

Minimum BVMS version

Update method Remarks

AiO

1

5000

DIP-52x

Windows Server 2016 R2

BVMS 9.0

System Manager package

Installation of System Manager 2.1 required as prerequisite.

AiO

1

7000

DIP-72x

Windows Server 2016 R2

BVMS 9.0

System Manager package

Installation of System Manager 2.1 required as prerequisite.

AiO

2

7000

DIP-73x Windows Server 2019

BVMS 10.1.1

System Manager package

Upgrade from Software Center to System Manager required as prerequisite.

AiO

1

4000

DIP-44x Windows Server 2022

BVMS 11.1.1

System Manager package

AiO

1

6000

DIP-64x Windows Server 2022

BVMS 11.1.1

System Manager package

11.5 Hardware drivers

Component

Version

NVIDIA Quadro

Quadro Pro Driver for Microsoft Windows 10 (64-Bit) 442.50 (February 2020)

Intel

Intel Graphics Driver for Windows 10 (64bit) – 4600 GPU – 26.20.100.7870

(2020-02-19)

Intel

Intel Graphics Driver for Windows 10 (64bit) – 530 GPU – 26.20.100.7870

(2020-02-19)

Hardware requirements
Bosch strongly urges customers to use the driver versions mentioned above. This ensures that the software can perform its task reliably and the specified performance (Recent Intel drivers show issues with H.265 decoding).

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

76 | 139

11.6 Virtualization

Manufacturer

Fail-over mode

Microsoft

HA

VMware

High availability

Version Windows Server 2016 (Hyper-V version 7) vSphere 6.0

Hardware requirements
The Video Recording Manager has an application specific fail-over mechanism (Failover VRM). Virtualizing the VRM is supported. Using virtualization fail- over mechanisms is not supported. When VRM virtualization and fail-over is required, we recommend running the Master VRM and Failover VRM in separate virtual machines and disable virtualization fail-over mechanisms for these virtual machines.

11.7 Patched issues for BVMS 10.0.1
A patch solves a very specific issue. Do not hesitate to reach out to our technical support teams in case you are experiencing an issue that is not described in these release notes.

ID

Description

Fixed in BVMS

BVMS Viewer

268300 FIXED: NetApp devices with Firmware version equal or higher than 11.60 cannot be added to BVMS.

10.1

Link to Link to

Downlo Downlo

adstore adstore

239712 / FIXED: cropped view of a panoramic camera was reset to default. 10.1 266928 Additionally, an Operator Client crash was fixed.

Link to Downlo adstore

Link to Downlo adstore

264271 FIXED: exception during DVD export.

10.1

Link to Link to

Downlo Downlo

adstore adstore

272951 FIXED: Inteox Camera: backward compatibility issues

10.1

Link to Link to

Downlo Downlo

adstore adstore

11.8 Resolved issues

The table below lists the issues that are resolved from previous releases. If an issue is known, but not described as resolved, it will not be fixed and we have accepted it’s behaviour.

ID

Description

200816

FIXED: The RemoteClientApi SDK functions in the BVMS script engine cannot be used from the BVMS Server. An external application needs to be used to control the client using the
RemoteClientApi.

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

77 | 139

ID 161813 246052 243056
242334 232050 224413
211909 233738
191197 238286 239102 236047
129648

Description

FIXED: When the BVMS SDK or OPC server is used for controlling Pan-Tilt-Zoom cameras, the zoom speed may differ between cameras.
FIXED: The operator client suffers from a small memory leak when opening 25 monitor group controls simultaneously.
FIXED: When adding a new decoder to BVMS, the “secure connection” is not enabled by default. Cameras are added by default with the “secure connection” enabled, which causes issues displaying cameras on decoders. Workaround: deselect “secure connection” for the cameras which need to be displayed on decoders or select the “secure connection” for the decoder.
FIXED: The loadbalancing parameters for the DIVAR IP AiO 7000 are incorrect. Workaround: correct the values manually: 256 iSCSI sessions and 550Mbit/s.
FIXED: Some dialogues are malformed when display scaling is used in Windows.
FIXED: After de-activating the “Set time automatically” flag in the Windows (10) time settings, the BVMS time synchronization mechanism stops working and the time within the system (including the connected cameras) might start drifting. BVMS generates a system warning if the time synchronization mechanism stops working.
FIXED: Compound events should not be nested: cyclic references to compound events could prevent the management server from processing other events.
FIXED: BVMS is able to lock-out an account after a configurable amount of failed password entries. This functionality is not enabled by default for the default “Admin” account. For security reasons Bosch strongly recommends enabling this option for the user-group “Admin Group”, changing the name of the “Admin” user-account, and adding a second user-account to the user-group “Admin Group”. This minimizes the chance that the system administrator is fully locked-out of the system.
FIXED: All LUNs that are scanned on an iSCSI target are added to the configuration.
FIXED: Executing a BVMS Client script, located in the logical tree of a sub- system, from an Enterprise Operator Client is not working.
FIXED: VSG 7.0.2 cannot use large LUNs.
FIXED: If the Operator Client crashes the system will automatically create a dump file. During the dump file creation process no progress is shown to the user, which might take several minutes. We have fixed this bug by showing a dialogue that indicates the progress of the dump file creation process.
FIXED: Automatic distribution of LUNs on multi-port iSCSI (eSeries) does not work correctly when a basic configuration is performed.Please remove the iSCSI device and add it again to your system. Then the LUNs are evenly distributed.

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

BVMS 12.1 – Release notes

78 | 139

ID 239593
225871 246706
240124 243150 206756 237381 262372 257258

Description
FIXED: When Operator Client and Management Server are installed on one single system the BIS communication might not work properly. Workaround: ensure that, on the Management Server, the “IsServerMode” setting in the C: ProgramDataBoschVMSAppDataBosch.Vms.BISProxy.settings.cxml is set to 1.
FIXED: False alarms: storage

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals