MOOIMOM M3 Breast Pump Hands Free Wearable Portable Electric Pumps User Manual

May 15, 2024
MOOIMOM

MOOIMOM-logo

MOOIMOM M3 Breast Pump Hands Free Wearable Portable Electric Pumps

MOOIMOM-M3-Breast-Pump-Hands-Free-Wearable-Portable-Electric-Pumps-
product

Wireless Electric Breast Pump M3
Read this user manual carefully before using your breast pump, and save the user manual for future reference. Failure to follow these instructions/safety information can lead to danger from the device.

OVERVIEW

MOOIMOM-M3-Breast-Pump-Hands-Free-Wearable-Portable-Electric-Pumps-
\(1\)

Additional flange sizes and spare parts are available for purchase at our

local service center.

CONTROL PANEL

  1. Power button
  2. Level up button
  3. Stimulation mode
  4. Level indicator
  5. Expression mode
  6. Massage mode
  7. Level down button
  8. Battery indicator
  9. Time display

MOOIMOM-M3-Breast-Pump-Hands-Free-Wearable-Portable-Electric-Pumps-
\(3\)

CAUTIONS

  • Make sure that you clean and sterilize the pump as instructed in this user manual.
  • Make sure that you assemble the pump correctly as instructed in this user manual.
  • To avoid leakage, clean the residue around the rim before assembling.
  • Wash your hands thoroughly before you take sterilized components.

ASSEMBLING

  1. Install direction the of valve installation. to the milk collector, paying attention to the MOOIMOM-M3-Breast-Pump-Hands-Free-Wearable-Portable-Electric-Pumps- \(4\)

  2. Put the silicone diaphragm into the milk collector, and press itwith your hands to make the edges fasten tightly to ensure a perfect sea I.
    MOOIMOM-M3-Breast-Pump-Hands-Free-Wearable-Portable-Electric-Pumps-
\(5\)

  3. To install the silicone shield on the milk collector, make sureto align the diversion groove on the silicone shield with the backflow groove on the milk collector, and then press the edges with both hands to ensure that the seal is in place.
    MOOIMOM-M3-Breast-Pump-Hands-Free-Wearable-Portable-Electric-Pumps-
\(6\)

  4. Install the main body of the breast pump on the milk collector, align the notch under the main body with the silicone diaphragm, and assemble it downward to fit the milk collector to ensure a complete seal fit.
    MOOIMOM-M3-Breast-Pump-Hands-Free-Wearable-Portable-Electric-Pumps-
\(7\)

  5. Connect the type-c charging cable to charge the pump motor.
    MOOIMOM-M3-Breast-Pump-Hands-Free-Wearable-Portable-Electric-Pumps-
\(8\)

WARNINGS
The breast pump cannot work when charging with a charger.

PUMPING INSTRUCTION

BEFORE PUMPING

  • Wash your hands well with soap and water, and make sure your breasts are clean. Gently squeeze a little milk from each nipple to make sure that milk ducts are not blocked.
  • Before every use, inspect the pump kit and tubing to make sure it is clean. Relax in a comfortable cllair, leaning slightly forward (use cushions to support your back).
  • Clean pump dials, power switch, and countertop with disinfectant wipes.

TO BEGIN PUMPING

  1. CD Press the flange firmly against the breast, leave no gaps and make sure your nipples are centered. Keep it upright.
    Be careful not to distort the position of the product and the chest, otherwise the breast pump will not have suction.
    MOOIMOM-M3-Breast-Pump-Hands-Free-Wearable-Portable-Electric-Pumps-
\(9\)

  2. Long press the power button to start the breast pump.
    Tekan lama tombol daya untuk menyalakan pompa ASI. TIPS
    The appliance has a memory function which remember the levels of the massage, stimulation, and expression in your latest usage.

  3. You can short press the “( ) 11 key to switch the stimulation mode. The screen will display stimulation mode symbol. There are 9 levels in this mode. You can choose the suction that makes you comfortable by pressing the”+ “level up and” -“level down button. In the early postpartum period, the milk duct is not easy to conduct, and this mode can be used to stimulate the breast and electively promote breast milk secretion.

  4. Short press the power button”( )” again. The screen will display the expression mode symbol. There are 9 levels in this mode. You can choose the suction that makes you comfortable by pressing the” + “level up and” – ” level down button. It can effectively improve the comfort and efficiency of breast pumping.
    Tekan lagi tombol daya” ( ) “. Layar LED akan menampilkan simbol mode memompa. Mode ini memiliki 9 tingkat. Anda dapat memilih mode menghisap yang membuat Anda merasa nyaman dengan menekan tombol + untuk menaikkan tingkat dan tombol – untuk menurunkan tingkat. Mode ini dapat meningkatkan kenyamanan dan efisiensi pompa ASI secara efektif.

  5. Short press the power button “ “again to display the massage mode symbol. There are 9 levels in this mode. You can choose the suction that makes you comfortable by pressing the” + ” level up and” – “level down button. During postpartum breastfeeding, breast discomfort such as swelling and lumps are prone to occur. Using this mode can alleviate breast problems.
    Tekan lagi tombol daya” ( )” untuk menampilkan simbol mode memijat. Mode ini memiliki 9tingkat.Anda dapat memilih mode menghisap yang membuat Anda merasa nyaman dengan menekan tombol + untuk menaikkan tingkat dan tombol – untuk menurunkan tingkat. Dalam masa menyusui pasca persalinan, ketidaknyamanan payudara seperti pembengkakan dan benjolan sering muncul. Dengan menggunakan mode ini dapat mengurangi masalah payudara.

  6. Long press the power button ” to turn off the  breast pump.

  7. The machine has a memory function. When you turn it on again, it will work as your last working mode and levels.

TIPS

  • Do not worry if your milk does not flow immediately. Relax and continue pumping. The first few times you use the breast pump, you may need to use a higher expression level to get your milk flowing.
  • When needed, you can also use massage or stimulation mode to do expressions.
  • During expression. you can switch between the massage, stimulation and expression mode by pressing the different mode button for better expression .
  • You do not need to use all levels, only use the levels that are comfortable for you.
  • Stop the expression immediately when the milk collector is almost full, and pour the breast milk into the bottle to prevent overfi I ling and overflow.
  • The pump motor will shut down automatically after 20 minutes from powered on.

ENDING YOUR SESSION

  1. When you finished expressing, press the power button to switch off and carefully remove the pump body from your breast.
    MOOIMOM-M3-Breast-Pump-Hands-Free-Wearable-Portable-Electric-Pumps-
\(16\) TIPS

    • After switching off the breast pump, break the seal between the breast and the pump funnel with your finger, and then remove the pump from your breast.
    • This appliance has a lithium-ion rechargeable battery inside, you can use without the adapter connected.
    • In order to protect the appliance, if you connect the adapter, the appliance will shut down automatically when you use the pump. The device has a three-grid battery display, when the power is off or no DC power is connected, the battery indicator DOES NOT display.
    • When the power is off, if DC power is connected, the battery indicator will lights up. When charging, the battery indicator will flash, the three grids are always on while fully charged .
    • When the device is working and no DC power is connected, the battery indicator is always be on if the battery is full, and flashes if the power is low.
    • When the device is working, if DC power is connected, the device will stop working. When charging, the battery indicator light flashes, and when the battery is fully charged, three indicator lights will always be on.
  2. Separate the milk collector from the pump motor ready 1-V for feeding/storage. Clean the other used parts according to the instructions.
    MOOIMOM-M3-Breast-Pump-Hands-Free-Wearable-Portable-Electric-Pumps-
\(17\)

  3. Pour the milk into the storage bottle; make sure the \:V slot feature is aligned with the bottle. TIPS
    • Do not continue pumping for more than 5 minutes at a time if you do not succeed in expressing any milk. Try to express yourself at another time during the day.
    • If the process becomes very uncomfortable or painful, stop using the pump and consult your breastfeeding advisor.
    • Never tilt the breast pump when the milk has reached the maximum line on the milk collector before re-pumping to avoid spillage.
    • After expression, please take off the milk collector from the pump body immediately, and then pour the milk into the milk bottle for sealing and storage

HINTS TO HELP YOU SUCCEED

TIPS

  • MOOIMOM Wireless Electric Breast Pump M3 is easy to use. Take some practice, and you will soon get used to expressing milk .
  • Choose a time when you are not rushed nor interrupted easily. Having your baby or a photograph of your baby nearby can help encourage your milk to flow.
  • Before expressing milk, place a warm towel onto your breast, and lightly stimulate for a few minutes. This encourages milk flow, and eases the pain of your breast.
  • Warmth and relaxation can encourage milk flow. Try expressing yourself after a warm bath or shower.
  • Try expressing from one breast while your baby is feeding from the other, or continue expressing just after a feed.
  • Using the breast pump frequently may help stimulate your breast milk to flow.

CHARGING YOUR BREAST PUMP

  1. Plug charger into the pump motor’s port. Colok pengisi daya pada port pompa.
  2. Plug the other end of the charger into any standard electrical outlet.
  3. Colok ujung lain pengisi daya pada stop kontak listrik standar.
  4. Once the pump motor is charged, remove the charger from the pump motor and unplug from the electrical outlet.

BATTERY STATUS INDICATOR ILLUSTRATION

MOOIMOM-M3-Breast-Pump-Hands-Free-Wearable-Portable-Electric-Pumps-
\(21\)

CHARGING TIMES
FULL CHARGE takes approximately 120 minutes and when fully charged, the battery indicator will stop blinking and display 3 grids continuously.

WARNINGS
ONLY USE the adaptor we recommend certified DCSVlA adaptor that meets requirement of standard IEC 609S0, and they should be placed outside of the patient environment when they are working

CLEANING & MAINTENANCE

HAND WASH

  • Place pump pa11s in a clean wash basin used only for infant feeding items. Do not place pump parts directly in the sink. Add soap and hot water to the basin.
  • Scrub items using a clean brush used only for infant feeding items.
  • Rinse by holding items under running water, or by submerging in fresh water in a separate basin.
  • Air-d,y thoroughly. Place pump parts, wash basin, and bottle brush on a clean, unused dish towel or paper towel in an area protected from di11 and dust. Do not use a dish towel to rub or pat items d ,y.
  • Clean wash basin and bottle brush. Rinse them well and allow them to air-d,y after each use. Wash them by hand or in a dishwasher at least every few days.

USING DISHWASHER

  • Be sure to place small items into a closed-top basket or mesh laundry bag. Add soap and if possible, run the dishwasher using hot water and a heated drying cycle.
  • Remove from the dishwasher with clean hands. If items are not completely dry, place items on a clean, unused dish towel or paper towel to airwdry thoroughly before storing. Do not use a dish towel to rub or pat items dryl

AFTER CLEANING

  • For extra germ removal. disinfect pump parts, wash basin, and bottle brush at least once daily after they have been cleaned.
  • Pump parts that come into contact with breast/breast milk can be disinfected using steam, or boiling in water for 5 minutes after cleaning.

TIPS

  • Flange, silicone diaphragm, valve and milk collector are dishwasher safe using top rack only.
  • Pump parts that come into contact with breast/breast milk should be disinfected by boiling in water for 5 minutes once daily.

WARNING

  • DO NOT wash Pump Motor.
  • Wipe with clean, damp cloth, if needed.
  • DO NOT use harsh chemicals to clean Flange, Silicone Diaphragm, Valve, and the Milk Collector.

MILK STORAGE GUIDELINES

  1. Use breast milk storage bags or clean food-grade containers with tight fitting lids.
  2. Avoid plastic containing bisphenol A (BPA)(recycle symbol #7). Write the date on the storage container, including your child’s name if you are giving the milk to a child care provider.
  3. Gently swirl the container to mix the cream part of the breast milk that may rise to the top back into the rest of the milk. Do not shake the milk. This can make some of the milk’s valuable parts break down.
  4. Refrigerate or chill milk right after it is pumped, if possible. You can put it in the refrigerator, place it in a cooler or insulated cooler pack, or freeze it in small (2 to 4ounce) batches for later feedings. Pumped milk is OK without being refrigerated for up to 4 hours after pumping.

MOOIMOM M3 Breast Pump Hands Free Wearable Portable Electric Pumps User
Manual Featured Image: No file chosen Update Post Add MediaVisualText Heading
4 H4 Close dialog Add media Actions Upload filesMedia Library Filter
mediaFilter by type Uploaded to this post Filter by date All dates Search
Media list Showing 52 of 52 media items UPLOADING 30 / 52 – MOOIMOM-M3-Breast-
Pump-Hands-Free-Wearable-Portable-Electric-Pumps- \(29\).PNG ATTACHMENT
DETAILS MOOIMOM-M3-Breast-Pump-Hands-Free-Wearable-Portable-Electric-
Pumps-22.png March 21, 2024 73 KB 677 by 631 pixels Edit Image Delete
permanently Alt Text Learn how to describe the purpose of the image\(opens in
a new tab\). Leave empty if the image is purely decorative.Title MOOIMOM-M3
-Breast-Pump-Hands-Free-Wearable-Portable-Electric-Pumps- \(22\) Caption
Description File URL: https://manuals.plus/wp-
content/uploads/2024/03/MOOIMOM-M3-Breast-Pump-Hands-Free-Wearable-Portable-
Electric-Pumps-22.png Copy URL to clipboard ATTACHMENT DISPLAY SETTINGS
Alignment Center Link To None Size Full Size – 677 × 631 Selected media
actions 52 items selected Edit SelectionClear Insert into post No file
chosen

NOTE

  • Store milk in the back of the freezer or refrigerator, not the door.
  • When freezing, leave an inch of space at the top of the container; breast milk expands as it freezers.
  • Milk can be stored in an insulated cooler bag with frozen ice packs for up to 24 hours when you are traveling.
  • If you don’t plan to use freshly expressed milk within 4 days, freeze it right away.

TROUBLESHOOTING

MOOIMOM-M3-Breast-Pump-Hands-Free-Wearable-Portable-Electric-Pumps-
\(51\) MOOIMOM-M3
-Breast-Pump-Hands-Free-Wearable-Portable-Electric-Pumps-
\(52\) MOOIMOM-M3
-Breast-Pump-Hands-Free-Wearable-Portable-Electric-Pumps-
\(53\)

MOOIMOM-M3-Breast-Pump-Hands-Free-Wearable-Portable-Electric-
Pumps-

TECHNICAL SPECIFICATIONS

POWER REQUIREMENTS

Only use the charger recommended as below: Charger specifications:
INPUT: 100-240 Vac, 50-60Hz, 0.4A-0.2A OUTPUT: DC5VlA.

SPECIFICATIONS

Pump Dimensions| 119 mm XllO mm X69 mm
Pump Weight| 226g
Milk collector Capacity| 180ml
Vacuum levels (Stimulation)| 40-lSOmmHg
Vacuum levels (Expression)| 105-245 mmHg
Vacuum levels (Massage)| 40-120mmHg
SPECIFICATIONS

Cycle Speed (Stimulation)| 66-84 cycles/minute
|
Cycle Speed (Expression)| 20-66 cycles/minute

Cycle Speed (Massage)| 69-92 cycles/minute
|
Use Life| 730hours (Defined to be approximately four
30-minute sessions per day for one year)
|
|
|
SPECIFICATIONS

Date of Manufacture: The date of
manufacture can be located within the serial number of the pump.The serial number is formatted as:
M3210001, M3 represents the mode l , 2 means the year is 2022,
l represents the first production batch of the year, 0001 represents the production sequence of the product.| For example: M3210001 Sebagai contoh: M3210001
|
|
|

OPERATING CONDITIONS

Operating Conditions

Operating Temperature| 5-40″C
Relative Humidity| 15%-90%; non-condensing
Atmospheric Pressure| 90 KPa to 106 KPa

TRANSPORT AND STORAGE

Transport And Storage

Temperature| -20 to 60°C
Relative Humidity| 15%-90%; non-condensing
|
Atmospheric| 70 KPa to 106 KPa

DISPOSAL INFORMATION

Pompa ASI ini mengandung baterai lithium-ion yang dapat diisi ulang. Gunakan sistem pengembalian dan pengumpulan lokal Anda untuk pembuangan limbah listrik dan peralatan elektronik (termasuk baterai).

WARNINGS

  • This device should not be used in the vicinity or on the top of other electronic equipment such as transceiver or radio control products. If you have to do so, the device should be observed to verify normal operation.
  • The use of components and power cord other than those specified, with the exception of cables sold by the manufacturer of the equipment or system as replacement parts for internal components, may result in increased emissions or decreased immunity of the equipment or system.

SYMBOLS DEFINITION
The warning symbol identifies all instructions that are important for safety. Failure to observe these instructions can lead to injury or damage to the breast pump! When used in conjunction with the following words, the warning symbol stands for :

WARNING
Can lead to serious injury or death
CAUTION
Can lead ta minor injury
NOTE
Can lead to material damage
TIPS
Useful or important information that is not related to safety

PUMP CONTROL BUTTONS

BUTTON

| FUNCTION

| ON/OFF or Mode selection

| LEVEL DO W N = D ECREASE SU CTION STRENGTH

| LEVEL  UP = INCREASE SUCTION STRENGTH

SYMBOLS ON THE PACKING

SYMBOL DEFINITION
This symbol indicates to keep the device dry.
This symbol indicates how to handle the fragile device with care.
This symbol indicates that

the outer carton is recyclable.
| This symbol indicates to keep the device away from sunlight
---|---
| This symbol indicates not disposing of the device together with unsorted municipal waste (for EUonly).
| This symbol indicates the temperature limitation for operation, transport and storage.
| This symbol indicates humidity limitation for operation, transport and storage.
---|---
| This symbot indicates the atmospheric pressure limitation for operation, transport and storage.
| This symbol indicates to please read the instructions before use.
| This symbol indicates to follow instructions for use.
| This symbol indicates that the packaging contains products intended to come in contact with food according to regulation 1935/2004.
---|---
| This symbol indicates that it is recyclable
| This symbol indicates that the material is part of a recovery/recycnlig process.
| This symbol indicates a carton package.
|
|

SYMBOLS ON THE DEVICE

| This symbol indicates to following instructions for use.
---|---
| This symbol indicates a type BF applied part.
|

This symbol indicates the manufacturer’s serial number of the device.

| This symbol indicates do not dispose of the device together with unsorted municipal waste (for EUonly).
---|---
| This symbol indicates the protection against ingressof solid foreign objects and against harmful effects due to the ingress of water.
| This symbol indicates the date of manufacture(four digits for the year and two digits for the month).
This symbol indicates direct current.

WARNINGS

  • Use the product only for its intended use as described in these instructions for use pamphlet.
  • This is a personal care product for a single user and should not be shared between users.
  • Only use parts recommended by us. Do not modify equipment.
  • Close supervision is necessary when the product is used near children.
  • Do not operate where aerosol spray products are used or oxygen is being administered.
  • Consult your healthcare professional to understand how long you should pump in a pumping session. MOOIMOM Wireless Electric Breast Pump M3 turns off automatically after 20 minutes.
  • The product is not provided in sterile condition.
  • Do not wash the pump motor. Wipe with clean, damp cloth only.
  • Do not immerse the pump motor in water.
  • Do not place the pump motor in the refrigerator or freezer.
  • Boil flange, silicone diaphragm, valve and milk collector prior to first use.
  • After boiling, allow these parts to cool before assembling.
  • Do not use harsh chemicals to clean the flange, silicone diaphragm, valve and milk collector.
  • Do not store damp components.
  • Do not put flange, silicone diaphragm, valve and milk collector in microwave or microwave sterilizer bags.
  • Do not microwave breast milk.
  • Do not use hot water to thaw breast milk.
  • Do not refreeze thawed breast milk.
  • If you are a mother who is infected with Hepatitis B, Hepatitis C or Human Immunodeficiency Virus (HIV), pumping breast milk will not reduce or remove the risk of transmitting the virus to your baby through your breast milk.
  • Do not drop or insert any object into any openings on the pump motor.
  • Do not attempt to open or repair the pump motor or charger. No modification of this equipment is allowed.
  • Pump will not work when connected to charger; always disconnect the pump from charger before using.
  • Only use the charger recommended by us.
  • Plug the charger into an electrical outlet that is visible and easily accessible. To remove line voltage; unplug the power supply from the wall.
  • Never operate a product if cord or plug is damaged, it is not working properly if it has been dropped, damaged or immersed in water.
  • Do not attempt to reset the pump motor during usage.
  • Gunakan produk hanya untuk penggunaan yang ditujukan sebagaimana dideskripsikan di dalam brosur instruksi penggunaan ini.

PRECAUTIONS

  • Ensure flange, silicone diaphragm, valve and milk collector are clean.
  • Ensure flange, silicone diaphragm, valve and milk collector are securely assembled and connected to the pump motor.
  • Before each use visually inspect the individual components for cracks, chips, tears, discoloration or deterioration.
  • In the event that damage to the device is observed, please discontinue use until the parts have been replaced.
  • If discomfort is felt, then suction can be broken by inserting a finger between the breast and the flange.
  • If irritation or discomfort occurs, discontinue use and see a doctor.
  • If a package appears damaged or tampered with before use, do not use and contact Customer Care.

USAGE & OPERATING LIFE PENCCUNAAN 

  • Pump motor is reusable for a single user, and has an expected operating life of 1 year.
  • Reusable parts- Flange, silicone diaphragm, and valve- should be cleaned prior to use. These parts are intended for use by a single user only, and should be replaced every 3 months.
  • Pompa dapat digunakan berulang kali oleh satu pengguna, dan memiliki masa pakai selama 1 tahun.
  • Komponen yang dapat digunakan berulang kali – pelindung payudara, diafragma silikon, dan katup – harus dibersihkan sebelum digunakan. Komponen-komponen ini ditujukan untuk digunakan hanya oleh satu pengguna, dan harus diganti setiap 3 bulan.

ELECTROMAGNETIC COMPATIBILITY COMPLIANCE STATEMENT INFORMATION
MOOI MOM Wireless Electric Breast Pump M3 may be used at home, office, or other general areas.Special consideration should be given to use:

  • During Medical Procedures: Do not use the pump during any medical procedure or during imaging. For example, do not
    use pumps during AF ablation of a skin anomaly, x-ray, MAI, or ultrasound.

  • With other equipment: Use of this equipment adjacent to or stacked with other eouipment should be avoided because it could result in improper operation. If such use is necessary, the pump and the other equipment should be obseNed to verify that they are operating normally.

  • In High Electrostatic Discharge Environments: If the air is very dry, use the pump where floors are wood, concrete, or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30%. If you notice shocks when you touch things. as sometimes happens in very dry winter months, be sure to touch a metal item such as a table before handling the pump.

  • In Industrial Settings; avoid using the pump near arc welding equipment, radar installations, and similar industrial settings.

  • Near RF Emitters: Keep devices that use WIFI, Bluetooth, and other international AF emitters at least 30 cm from the pump during operation. This includes communications equipment peripherals such as antenna cables and external antennas. Otherwise, degradation of the performance of the pump could result. If you know the power output of the RF emitter, the table labeled “Electromagnetic Compatibility Compliance Statement Information” can be used for more precise information about separation distances.

WARNINGS

Use of accessories other than those specified by us may result in increased emissions or decreased immunity of MOOIMOM Wireless Electric Breast Pump M3. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions :

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

NOTE
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals