R DE Caster Duo Integrated Audio Production Studio Black User Guide
- May 15, 2024
- R DE
Table of Contents
Caster
QUICK START GUIDE
Panduan Memulai Cepat
Caster Duo Integrated Audio Production Studio Black
NORTH AMERICA
The RØDECaster DUO must not be co-located or operated in conjunction with any
other antenna or transmitter.
The device complies with part 15 of the FCC rules. Operation is subject to the
following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference
that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC rules.
These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications.
However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one of more of the following measures:
- Reorient or relocate the receiving antenna
- Increase the separation between the equipment and receiver
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
- Consult the dealer or an experienced radio/TV technician for help
This equipment complies with FCC radiation exposure limits set forth in an uncontrolled environment.
Changes or modifications not expressly approved by RØDE could void the user’s
authority to operate the equipment.
For USA: The frequency stability of all transmission frequencies of U-NII-1,
U-NII 2A, U- NII 2C and U-NII-3 meets the requirements of 47 CFR FCC
Part15.407(g), and the manufacturer declares that their transmission is
maintained at Band U-NII-1, U-NII 2A, U-NII 2C and U-NII-3.
For Canada: The frequency stability of all transmission frequencies of
U-NII-1, U-NII 2A, U- NII 2C and U-NII-3 meets the 47 CFR FCC Part15.407(g)
requirements, and the manufacturer states that their transmissions remain
within the U-NII-1, U-NII 2A, U-NII 2C and U-NII-3 bands.
CAN ICES-3 (B) / NMB-3 (B)
This Class B digital apparatus complies with Canadian ICES-003
This device contains license-exempt transmitter(s)/receiver(s) that comply
with Innovation, Science and Economic Development Canada’s license-exempt
RSS(s). Operation is subject to the following two conditions:
- This device may not cause interference
- This device must accept any interference, including interference that may cause undesired operation of the device
RADIATION EXPOSURE STATEMENT
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment shall be installed and operated with
minimum distance 20cm between the radiator & body.
Radio Frequency Exposure Statement for Canada
The device has been evaluated to meet general RF exposure requirements. The
device can be used in mobile exposure conditions. The minimum separation
distance is 20cm
Operation of this device is restricted to indoor use only. (W52 band)
EU COMPLIANCE STATEMENT
Hereby, RØDE Microphones declares that the radio equipment type RØDECaster DUO
is in compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the
following internet address: https://info.rode.com/rodecaster-duo
For details of EU representative go to http://en.rode.com/distributors
CAUTION:
The RØDECaster Duo has been designed to be used with the provided power
supply, as use the provided power supply only.
Stop using the power supply unit and any cables if:
- There is any damage to the charging port, power connector or power cord
- The power supply unit is exposed to excessive moisture, or liquids is spilled into the power supply unit
- The power supply unit enclosure is broken
POWER SUPPLY UNIT SPECIFICATIONS:
Model Name: YDS-PD030A
Frequency: 50-60 Hz
Line Voltage: 100-240 Vac
Output Ratings: 20Vdc 1.5A; 15Vdc 2.0A;
12Vdc 2.5A; 9Vdc 3A; 5Vdc 3A
Operating Frequency Range | The maximum RF Output Power |
---|---|
Bluetooth 2402-2480 MHz | 3.68 dBm (BR/EDR) |
4.59 dBm (BLE) EIRP
WiFi 2412-2472 MHz| 15.99 dBm EIRP
WiFi 5150-5250 MHz| 16.71 dBm EIRP
WiFi 5250-5350 MHz| 16.71 dBm EIRP
WiFi 5470-5725 MHz| 16.71 dBm EIRP
WiFi 5725-5850 MHz| 14 dBm EIRP
2.4G SRD 2402-2480 MHz| 1.19 dBm EIRP
Note 1: “Exceeding 0.1 wt %” and “exceeding 0.01 wt %” indicate that the
percentage content of the restricted substance exceeds the reference
percentage value of presence condition.
Note 2 :“○” indicates that the percentage content of the restricted
substance does not exceed the percent- age of reference value of presence.
Note 3: The “-” indicates that the restricted substance corresponds to
the exemption.
USA
** FCC ID: 2AEAN-RCDUO
CANADA
IC: 20091-RCDUO
CAN: ICES-3 (B) / NMB-3 (B)
NEW ZEALAND
R-NZ
SOUTH KOREA
ID: R-R-R72-RCDUO
Company Name: RØDE Microphones
Model: RØDECaster Duo
Country of Origin: Australia
NCC
CCAJ23LP14E0T9
BSMI
D39882
RoHS
JAPAN**
210-211103
INDIA
IS 13252(PART 1): 2010/IEC 60950-1: 2005
R-41263699
MEXICO
POWER
9Vdc 3A
rode.com
0927-0840-02-05
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>