Overview

This product adopts an 8-inch capacitive touch display screen, which can be used for power supply and charging equipment, and the power supply adopts three channels, 12V adapter power supply, 5V/USB power supply, built-in 10,000 mA polymer lithium battery, and can be used as electronic Album use, record data 43200 groups, local record data curve view, daily, weekly curve, can set alarm value and alarm mode, alarm setting, screen brightness adjustment, computer connection to read the disk PDF document output

Test items:

  1. PM2.5 (air quality)
  2. PM10 (air quality)
  3. CO2 (carbon dioxide)
  4. HCHO (formaldehyde)
  5. TVOC (volatile matter)
  6. Air (atmospheric pressure)
  7. CO (carbon monoxide)
  8. CH4 (methane)
  9. Smoke
  10. TEMP (ambient temperature)
  11. Humidity (ambient humidity)
  12. AQI (Air Quality Index)
  13. Human Body

Safety and Maintenance

  1. Do not use the instrument in a dusty or corrosive gas environment, so as not to reduce the life of the instrument or damage it
  2. Please charge in time when the battery icon on the display is empty or red
  3. Do not store or use the instrument in high temperature, high humidity, flammable, explosive and strong electromagnetic field environments.
  4. For maintenance, please use a soft cloth and neutral detergent to clean the casing. Do not use abrasives and solutions to prevent the casing from corroding and damaging the instrument.
  5. When you need to use it for a long time, it is the best choice to use a 12V adapter to supply power

Interface Function

RuchundeBu-TC-9100-Air-Detector-Comprehensive-Indoor-Air-Monitor-
FIG-1

  1. Power button : long press to turn on or off
  2. TYPE-C interface : for human body temperature measurement module/standby 5V power supply
  3. MicroUSB interface: spare 5V charging and power supply
  4. Power supply 12V interface: power supply and charging power supply (preferred)
  5. USB5V output interface: charge other devices

Function setting

RuchundeBu-TC-9100-Air-Detector-Comprehensive-Indoor-Air-Monitor-
FIG-2

  • Alarm mode selection

  • Screen LED brightness

  • Rest screen time 0 (off) 1-99 minutes on

  • The screen saver is turned on or off (the electronic album function is realized after turning on)

  • Date/Time/Week Selection

  • logging interval

  • Record the number of groups

  • PDF data file export operation:

    • Generate PDF document
    • Connect to a USB computer
  • Turn WIFI on or off (this operation is only applicable to models with this function)

  • data deletion

  • Data calibration (C02)
    Note : The calibration can only be performed in an environment of 400PPM

  • Alarm clock

  • All settings are restored to the parameters before the factoryRuchundeBu-TC-9100-Air-Detector-Comprehensive-Indoor-Air-Monitor-FIG-12

  • Enter the function setting interface

  • Enter the historical data curve table interface

  • Alarm value setting

Electronic album production

RuchundeBu-TC-9100-Air-Detector-Comprehensive-Indoor-Air-Monitor-
FIG-16

  1. After the picture is completed, enter the operation on the right
  2. PDF data file export operation: connect to a USB computer
  3. Put the processed pictures into the specified folder of the U disk, touch any position on the screen to exit the computer connection, and complete the production

Body and object temperature measurement

Temperature measurement:

  1. It is best to be 1-5cm away from the object to be measured (can not touch the object or the distance is too far to avoid temperature measurement deviation)
  2. If there is a deviation in the temperature measurement, a mercury thermometer can be used as the standard, and the temperature can be fine-tuned on the human body temperature measurement alarm value setting interface
  3. Inserting the temperature measuring head needs to be done in a shutdown state to avoid inaccurate temperature measurement

Technical Specifications

project scope Accuracy U n i t s
PM2.5 0-1000 0~100μg/m³

±10μg/m³ 100~1000μg/m³

±10%

| μg/m³
PM10| μg/m³
CO2| 0-10000| ±50PPM+3 read

value

| PPM
HCHO| 0.001-1.000|  | mg/m3
TVOC| 0.001-2.000|  | mg/m3
Air| 300-1200| ±1hPa(or±8m)| hPa
CO| 0-500| ±10PPM+5 read

value

| PPM
CH4| 0-100 | ±3 |
Smoke| 0-100 | ±5 |
TEMP| -20-60| ±2|
Humidity| 0-100| ±3| %
AQI| 0-500| 10%| %
Human body and object

temperature measurement

| 0-100| ±0.3|
Human body and object| 1-5cm| ±0.3|
temperature measurement

distance

|  |  |
---|---|---|---
Battery powered| Polymer rechargeable lithium battery

10000mAh

| mAh
Adapter power supply

(charging)

| 12V/3A| V
data record| 43200| group
weight|  |
size| 23018036mm| mm

Color change numerical range table

 | PM2.5| PM10| CO2| HCHO| TVOC| Air| CO| CH4| smoke| ℃/℉| RH

| body
---|---|---|---|---|---|---|---|---|---|---|---|---
green| 0-12| 54| 450| 0.100| 0.500| 1200| 30| 5| 0| 25| 60| 37.3
yellow| 35.4| 154| 700| 0.200| 0.800| 800| 100| 20| 20| 28| 70| 38.0
orange| 55.4| 254| 1000| 0.300| 1.100| 700| 200| 30| 40| 31| 75| 38.1
red| 150.4| 354| 2000| 0.400| 1.400| 600| 300| 40| 60| 34| 85| 38.5
Purple| 250.4| 424| 5000| 0.500| 1.700| 500| 400| 50| 80| 37| 90| 39.1
brown| 1000| 1000| 10000| 1.000| 2.000| 300| 500| 100| 100| 40| 100| 42.0

RuchundeBu-TC-9100-Air-Detector-Comprehensive-Indoor-Air-Monitor-
FIG-18

Operation precautions

  1. Use a 12V power adapter for long-term power supply
  2. There are many product testing categories, and it is normal to have fever
  3. There are two cooling fans inside, please understand if the noise is louder
  4. When measuring human body temperature, please keep the measurement distance 1-5cm, and the measurement time is more than 3 seconds. If there is any deviation in the measurement temperature, you can refer to the mercury thermometer and then fine-tune the temperature measurement.
  5. Do not plug and unplug the power supply equipment easily. If necessary, please turn off the power before operating it, so as to avoid data loss due to sudden power failure.