Feature
PRE-USE INSTRUCTIONS
- Clean it before use. If your humidifier presents a little odour at first use, don’t worry; any smell should disappear quickly. For more details, please check this manual in the section CLEANING AND MAINTENANCE.
- This humidifier is suitable for a working environment between 41 °F to 104 °F, with relative humidity less (RH) than 80%. Use clean water (preferably purified or distilled) with a temperature below 104 °F.
- When the humidifier has not been used for over a month, the water tank, base sink, and aromatherapy box should be cleaned before using again. Empty any stale water from the tank and sink on top of the base before cleaning.
Read And Save These Instructions and Safety Information
To reduce the risk of fire, electric shock, or other injury, follow all instructions and safety guidelines. Please use this product in strict accordance with this manual.
Safety Guidelines
- Only use the humidifier as described in this manual.
- Always make sure to place the humidifier on a flat, level surface before operation.
- Place the humidifier so that it will not get knocked over or the power cord pulled accidently
- Keep the humidifier out of reach for small children and pets.
- When not in use, turn the humidifier off and disconnect from power by removing the plug from the receptacle outlet.
- Always unplug your humidifier from the power receptacle outlet before installation, filling it with water, cleaning, detaching the water tank from the humidifier base, or when not in use.
- Ensure your power cord plug is correct for your country’s residential power voltage and receptacle outlet.
- Do not place near large pieces of furniture or in high-traffic areas.
- Do not use the humidifier in wet environments.
- Do not open the humidifier base or remove the water level float sensor for self-servicing; there are NO User-Serviceable Parts inside the humidifier base.
- Only fill the water tank with clean water (distilled or purified water preferred). Never fill the water tank with any other liquids.
- Do not turn on the humidifier if it has no water.
- Do not use any hard or sharp tool to attempt scratching off scale buildup inside the water tank or in the humidifier base sink.
- Do not use wet hands when plugging or unplugging the humidifier power cord.
- Do not touch the inside of the humidifier while it is working.
- Do not put water or any foreign objects into the air/ mist outlet or air inlet. Do not block the air outlet or air inlet while working.
- Do not add water directly to the base, or mist/ air outlet channel, and do not make water flow or splash into the inside of the humidifier’s base. Doing so may damage the unit’s internal parts.
- Do not add aromatic substances (e.g., essential oils, scents, etc.) directly to the water tank. Only put these substances in the appropriate aromatherapy box as later described
Operational Compliance
- Do not disassemble the humidifier base; if you find abnormalities or have problems in operation, please immediately unplug the power cord, review these instructions for proper use, and if still concerned, contact the manufacturer. Our professional staff will
- promptly respond and help resolve any problems.
- Your humidifier should be placed away from furniture and appliances, avoid directly blowing on anything for the risk of wetting and/or damaging them.
- Your humidifier should be placed away from high-heat sources such as fireplaces, and furnaces/heaters, and avoid direct sunlight.
- Your humidifier should be placed on a flat and sturdy surface; ensure the water tank is positioned and kept level to avoid tilting, causing water to spill, or creating false alarms of water shortage, and other abnormalities.
- This product is for personal home use only.
- To avoid the growth of bacteria, please replace any stale water inside the tank and base and clean regularly
- If you do not plan to use the humidifier for a long time, please pour out the water left in the tank and base, clean and dry all parts, and store them safely for your next use.
About the Humidifier Base
This humidifier base uses ultrasonic atomization membrane vibration, which
breaks liquid water into a fine vapour mist and outputs it through the
mist/air channel. The water tank is only a storage device to hold water until
vaporized. Water flows from the tank to the “sink area” at the top of the
humidifier’s base where the atomizer membrane is. As the liquid water is
vaporized, it is pumped up the mist/air channel in the centre of the tank, and
out the outlet nozzle cap in the tank lid. The bottom of the clear plastic
water tank (between the tank and base) will accumulate moisture; this is
normal and not any reason for concern.
Adjustments to the Mist
While using, if there are water droplets found around the machine and/or the
local area of operation, the room’s humidity is too high; please lower the
mist setting or discontinue use.
Knowing Your Humidifier
Package Contents
- 1 x Smart Ultrasonic Humidifier
- 3 x Aroma Pad (1 Pre-Installed)
- 1 x Water Filter (1 Pre-Installed)
- 1 x Water Purification Device
- 1 x Cleaning Brush
- 1 x User Manual
Unpacking and Setting Up Your Humidifier
- Place the humidifier on a sturdy horizontal table, do not plug in the power cord yet. Remove all the shipping tape and the foam shipping block from between the water tank and base. Verify the water filter is pressed into place over the water flow control valve and put the purification device inside the water tank following the illustrations above.
- Align the mist nozzle cap with the large opening in the centre of the humidifier lid, and then press it into place. A “Click” indicates successful assembly. Place the water tank securely on the humidifier base. Note: The water tank only fits onto the humidifier base one way – do not force it to fit the wrong way!
- When the humidifier’s water level is too low, the humidifier will automatically cut off the power and stop working. The low water level icon will illuminate. Please turn off the power button first, unplug the power cord from the receptacle outlet, and add more water to the tank.
Using Your Smart Humidifier
-
Ensure the power cord is unplugged from the outlet receptacle.
-
Add water to the tank and put it securely on the humidifier base. Please note, the water tank easily fits on the humidifier base one way – do not attempt to force it to fit the wrong way!
-
While tap water will work, impurities and minerals in tap water will necessitate more frequent cleaning of your humidifier. For this reason, we recommend using Distilled or Purified Water. You may add water directly through the ventilated water tank lid or remove the lid and pour directly into the tank.
Do Not pour or splash water into the mist /air outlet channel in the centre of the tank! -
Do not exceed the “maximum water level” when adding water.
-
Note: In operation, if the water tank runs too low, the humidifier will automatically cut off the power and stop working. The low water level icon will illuminate. Please turn off the power button first, unplug the power cord from the receptacle outlet, and add more water to the tank to resume normal operation.
-
Once the water tank is filled and securely placed onto the humidifier base, plug the power cord into a receptacle outlet. The unit will beep once and enter standby mode.
-
Press the Power On Button and the humidifier should begin to work. Adjust the amount of mist to the desired level (1 =low to 3-high} with the Mist+ and Mist -buttons.
-
The mist nozzle cap (installed above) has single and dual output modes. When the two mist outlets are aligned, it provides a single output, and when they are not aligned, it is a dual output. You can adjust the direction of misting 360 degrees.
-
The specific operation of the touch screen and the icon indication are shown in the “Introduction to Buttons and Icons” section of this manual.
-
If you wish to add aromatherapy scents, press the air inlet/aromatherapy box cover lightly to eject the box and tray. Add a few drops of aromatherapy to the sponge pad, and then press to close the aromatherapy box.
Note: it only takes a few drops of scent to work – be careful how much you put in. Start small and work up if needed.
Introduction to Buttons and Icons
Note : The screen displays the current room humidity by default When setting other functions, the screen will display accordingly. After completing the settings,the screen returns to humidity display.
Cleaning and Maintenance
- Unplug your humidifier from the outlet receptacle before cleaning.
- Your humidifier has very few user-serviceable areas and parts. Keeping the water tank and the base sink area clean will be much easier if you use the recommended Distilled or Purified water, instead of plain tap water.
- Do not use any abrasive cleaners or scrubbing pads! Soaking parts in White Vinegar will loosen mineral deposits and brushing with the supplied cleaning brush or an old toothbrush should be enough to remove deposits. White Vinegar is also an antiseptic agent and will help keep your humidifier germ-free.
- Water flow from the water tank to the humidifier base sink area is controlled by the water level float sensor in the base contacting the spring valve at the bottom of the water tank. When the water level in the base is low, the float sensor lowers which opens the spring value to allow water from the tank to refill the base sink. This spring valve has a soft rubber gasket which should checked occasionally, or if water overflows the base. Debris or mineral deposits might cause this gasket not to seal properly. It is easy to remove, clean, and re-install.
Regular Cleaning
- Step 1: Remove the water filter by pulling it straight up without twisting.
- Step 2: Remove the spring valve silicone gasket by pulling (do not twist or bend) on the valve stem from the underside of the water tank. The silicone gasket snaps on/off the stem with a spring.
- Step 3: Clean the water filter area, where the gasket seats, and all removed parts.
- Step 3: Re-install remove and clean parts. The gasket fits over the valve stem with the concave side up. Push the cleaned water filter assembly back into place without twisting.
Routine Cleaning
After prolonged use, calcium and magnesium ions precipitate out of the water
to form a scale, which will affect the humidifier’s effectiveness.
Additionally, the air inlet filter may become clogged with dust or pet hair,
also reducing efficiency. Unplug the humidifier from any power outlet
receptacle before cleaning.
- Clean the atomizer and sink area of the humidifier base, water tank, filter, mist channel, and aroma box/air inlet sponges.
- Replace any stale water in the tank and top of the base with fresh clean water (distilled or purified recommended) and keep the inside of the humidifier’s surfaces clean.
- When not in use for a long time, please unplug the power cord, empty all water, clean and dry the parts, and store them in the original box in a cool place.
Cleaning humidifier base sink
- Add about 4 ounces of White Vinegar to the sink area of the humidifier base (increase or decrease as appropriate, depending on the degree of limescale) and soak for 2-5 minutes.
- Gently brush to remove scale, then rinse well with clean water.
Cleaning the aroma box and air filter
- Take out the aromatherapy sponge and air filter, wash and dry them.
- Clean and dry the aroma box with a damp cloth, put the sponge and filter back in place, and return the aroma box. After cleaning, please check if all parts are in place before using it again.
Cleaning water tank
- Remove the water tank from the humidifier base and remove the purification unit. Add a small amount of White Vinegar or common dish detergent (5-10 drops), then add water to about 1/4 tank capacity, soak for 5-10 minutes, and brush clean. Rinse thoroughly
Specifications
Product Name | Cool Mist Humidifier |
---|---|
Model Number | BK-888 |
Rated Voltage | 100-240V |
Rated Frequency | 50-60Hz |
Power Rating | 25W |
Water Tank Capacity | 2.5L/3L/5L/6L |
Mist Output (per hour) | 200-400ml/hr |
Country of Origin | China |
Implementation Standard
| GB 4706.1 a 2005
GB 4706.48 a 2009
Troubleshooting
Troubleshooting Methods
if your humidifier is not working correctly, please check the following before contacting customer support:
My humidifier does not work
- Make sure that the power cord is connected to a powered outlet and the available voltage corresponds with the voltage indicated on the humidifier. Make sure you have pushed the Power On button.
- The humidifier will shut down automatically in the event of low water.
- Check the water tank is installed properly on the humidifier base.
My humidifier is not misting.
- Ensure the unit has power and is turned on. Adjust the mist level to a higher setting.
- Ensure the purification device is in the upper water tank, not in the sink area on top of the base.
- The base has too much water. Unplug the unit, remove the water tank, empty water from the base, and correctly install the water tank on the base, ensuring there is adequate water in the tank.
- Please ensure the air inlet is not blocked.
- Make sure the mist output nozzle is not blocked.
- Make sure the humidifier is on a flat-level surface.
- The water temperature may be too low, turn the mist level to the highest setting and let it run for a while, then adjust to the desired setting.
- If the water tank or base was recently washed with detergent, rinse thoroughly with clean water to remove any remaining detergent residue
Water leaks from my humidifier.
- Make sure the silicone spring valve gasket around the valve stem is secure with no debris or rips preventing a good seal.
- Make sure the silicone gasket is installed correctly with the concave side facing up.
- Ensure the foam shipping block between the water tank and humidifier base is removed.
- Avoid running the humidifier in a room with over 60% relative humidity.
- Wipe any excess water, and attempt to see exactly where the water is coming from.
- Do not shake the humidifier.
- Make sure to place the humidifier on a flat, level surface.
- Check the water tank for cracks or leaks. If there are leaks, contact Customer Support
The mist produces an unpleasant smell.
- Use purified or distilled water. We do not recommend the use of tap water.
- Change water regularly to avoid dirty/stale water accumulation.
- Clean the humidifier and keep it dry for 12 hours with the cover detached.
- Clean the aromatherapy pad tray and inside the area where it fits in the base, change the aroma pad.
There is white dust in the water tank and/or on top of the humidifier base
You should clean and descale the humidifier regularly. Using purified or
distilled water can help prevent the formation of scale. See the instructions
above about descaling with White Vinegar.
If after the above steps and treatment, the humidifier still does not work
correctly, do not hesitate to contact our after-sales service centre, and our
company will gladly serve you.
For an after-sales service centre, please contact: Deepwave-
aftersales@outlook.com
Warranty
Warranty Policy
- This machine is guaranteed for 1 year under regular use from the date of purchase. (Subject to the date of purchase invoice)
- The free warranty does not cover the following cases, but you can still enjoy the following preferential repair services with material charges only
- Failure to follow the operating procedures and precautions in the manual can cause the product to malfunction.
- Product failure caused by accidental disasters, major forces, and other factors, such as excessive voltage, fire, flood, earthquake, and others
- The warranty period has expired.
- Unauthorized alteration, misuse, or accidental damage by Customer.
- The use environment exceeds the product specifications.