OPTI CLIMATE Revomax II Smart Remote Controller User Guide
- May 15, 2024
- OPTI CLIMATE
Table of Contents
Revomax II Smart Remote Controller
User Guide
Installation
Installation spacing
To guarantee proper air suction, leave at least 15cm of space between the wall
and the backside of the unit, where the carbon & dust filters and air inlet are
located. At least 15cm of space should also be left between the topside of the
unit and the ceiling. Larger spaces are preferred. The unit must stand free
from the wall to avoid contact noises. Installation
The unit can be hung from a ceiling or placed on a stand or frame.
Ceiling
To hang the unit from a ceiling, remove both side panels and pinch a hole
through the insulation at the position of the 4 holes in the bottom of the
unit. Use an M8 or M10 metal threaded rod with a nut, washer and rubber damper
to prevent unwanted noise or vibration.
Stand or frame
Make or buy a stand or frame to hold the weight of the Opticlimate. (see
nameplate )
You can use the rubber damper or a vibration damper (not incuded)
Pinch a hole through the insulation at the position of the 4 holes in the
bottom of the unit. Use an M8 bolt and washer to mount the rubber or damper.
Make sure the side of the condensation outlet is 1 cm lower than the opposite side.
Routing the Cables
First, the panel at the left
side near the manometer should be removed to make the various electrical
connections.
A magnetic valve, water leakage sensor, automatic moisture meter, remote
control and room temperature sensor are supplied with the unit. Their cables
can be led to the outside through the opening at the bottom of the panel.
The power cable for the power supply can be led through the black feed-through
rubber at the side of the unit.
ELECTRICAL CONNECTION
Automatic Humidity Sensor with light cell
The Automatic Humidity Sensor with light cell supplied with the unit can be
found in the connection set supplied with Revomax. The cable should be led
through the opening in the front panel and connected to the circuit board (see
picture) The sensor should be hung in the room and may not be covered. The
light cell determents if it’s night or day.
Room temperature sensor
The connection set also contains a room temperature sensor, which needs to be
connected to the printed circuit-board. This sensor should be led to the
outside through the opening in the panel and should be hung at the level of
the upper side of the vegetation. The sensor should be protected against heat
radiation and must be put in the shade. A protective cover over the sensor is
sufficient.
The Smart Remote Controller
The smart remote controller can be found in a separate black box, the cable to
connect the smart remote controller can be found in the connection set. The
cable must be led through the opening in the panel and the UTP connector must
be connected to the circuit board (see picture) The USB side of the cable can
be plugged in one of the USB ports on the smart remote controller.
Power supply specifications
4 different OptiClimate models are available. For your safety and the safety
of the OptiClimate, the following specifcations should be observed when
connecting the power supply: use the circuit breakers (MCB) and cable
thickness specifed.
The cables for the supply voltage should be led through the grommet at the
side of the unit and connected to the green screw terminal on the circuitboard
as described in the illustration. The grounding can be connected to the PE at
the bottom right of the metal back plate.When it’s not possible to use a 3 phase power supply but only a
single phase power supply is available the phase L1 + L2 + L3 need to be
looped using a correct diameter wire. (only 6000 and 10000 models)
WATER CONNECTIONS
Water-in and water-out connections of the cooling water.
The unit can be used by connecting the water in and out connections to a cold
water supply and a drain or can be used using the Opticlimate water cooler to
cool the water in a closed loop. (connections and discription of a water
cooler setup need to be obtained in the water cooler manual. Only the setup
using a cold water supply and a drain are discribed in this manual.
Using a water cooler or other closed loop systems skip to page *
The unit has a water inlet and outlet. The inlet needs to be connected to a
cold water supply (max 25°C) with a solenoid valve installed at the beginning
of the piping going to the Opticlimate water-in connection. In case of a
waterleak the valve will close.
Mounting the valve at the end of the piping (near the Opticlimate) is
pointless. (always check the flow direction arrow on the valve!).
Make sure that the black magnetic coil of the solenoid valve is positioned
upwards (preferred) or to the side. If it is positioned downwards, condensate
from the cold valve might enter the coil. Make sure that the solenoid valve is
installed at a fxed point that is always easily accessible to the user. A strainer should be
placed in the water inlet. This strainer prevents blockage in the heat
exchanger inside the unit. It is recommended to insulate the cold water supply
line in order to prevent condensation build-up. The upper water connection is
the water-outlet. The water-outlet can be connected directly to the drain
(sewer). Alternatively, the warm water can be used for heating purposes. The
water is aprox 35°C- 40°C.
The water flow (water usage) is automatic regulated by an electronic flow
regulator inside the unit.
When you use and alternative cold water supply such as a well or water from a
river , leak or pond, make sure the water is filtered and clean the heat
exchanger on regulare base. Contact tech support for more information
regarding cleaning the heat exchanger.
CONDENSATION WATER
Discharge of the condensation water
The unit will dehumidify the air during cooling and in dehumidify mode. The
moisture extracted from the air is collected in the condensation an. The
condensation pan has an ¾ drain pipe where the condensate will run off. The
condensate can be used as irrigation water.
The cooling block has been modified to prevent metals or oxides from entering
the condensate water.The location
of the drain pan is on the negative pressure side of the unit, meaning that
air can enter into the unit through the condensation drain, It’s highly
recommended to use a “P-trap” on the condensation outlet to prevent air
entering the unit and to prevent condensate run-off problems.
Not using a p trap also results in loss of capacity and bypassing non
processed air.If the unit is installed
at the same level or lower than the drain or sewer, a condensation lift pump
can collect the water. This small lift pump pumps the water through a hose of
9mm to a height of 4 metres into the drain or collecting tank. Stronger pumps
are also available.
SMART RExMOTE CONTROLLER
Connecting the Smart Remote Controller Power
Connect the power supply and USB connector from the remote cable to the Smart
Remote controller. Connections
At the back of the Smart Remote Controller you find the USB, HDMI, Ethernet and
power supply connections.
CONNECTIONG THE SMART REMOTE CONTROLLER Connect the RJ45 side of the remote control cable to
the RJ45 plug at the left upper corner of the circuit board (see image)
Powering up the unit
- Power on the Smart Remote Controller
- Power on the Opticlimate by switching on the power supply.
- Open the water supply.
After powering up the Opticlimate, the unit will first initialize, this can
take a few minutes.
All valves and sensor are tested prior to startup. The remote controller
cannot be operated during initializing of the Opticlimate.
After powering up the Smart remote controller, the remote will first
initialize, this can take a few minutes. You will see several screens pop-up
and close again, this is normal.
The unit is now installed and ready to use
OPERATING BY USING THE SMART REMOTE CONTROLLER
After both Smart controller and Opticlimate are initialised, the Smart Remote
controller will display the Home screen *1 Alarm
The ALARM icon will display an alarm (power failure) this is normal after
startup and will show each time you power up the unit or in the case of a
power failure.during initializing of the Opticlimate. After powering up the
Smart remote controller, the remote will first initialize, this can take a few
minutes. You will see several screens popup and close again, this is normal.
Reading and deleting the alarm
You can obtain more information regarding this alarm by pushing on the
“enlarge button .
You can erase the alarm by pushing on the alarm icon and then press the bin .
In the right upper corner you find the home icon you can toggle between home 1
(basic) and home 2 (advanced)
Homescreen 1
You can obtain more information regarding this alarm by pushing
on the “enlarge button” .| Homescreen 2
You can obtain more information regarding this alarm by pushing
on the “enlarge button” .
Setting the basic parameters
Go to home 1 or home 2 by pressing the home icon.Touch the Temperature area to enlarge the window for
temperature day/night settings. Setting
day temperature setpoint.
Touch the sun icon to set daymode temperature and use + and – to change the
daymode temperature. Setting night temperature
setpoint.
Touch the moon icon to set nightmode temperature and use + and – to change the
nightmode temperature.
Touch the X to return to home.
Setting day and night dehumidify setpoint
Go to home 1 or home 2 by pressing the home icon. Setting day and night temperature setpoint.
Touch the dehumidify area to enlarge the window for dehumidify day/night
settings.Setting day temperature setpoint.
Touch the sun icon to set daymode humidity and use + and – to change the
daymode humidity setpoint.Setting
night temperature setpoint.
Touch the moon icon to set nightmode humidity and use + and – to change the
nightmode humidity setpoint.
Touch the X to return to home.
On/off switch Setting day and night temperature
setpoint.
In the right upper corner you find the on/off button.
Touching the button will switch the unit on and the icon turns green.
Touching the button again will turn the unit off and the icon will turn red.
Sequence of operation when the unit is turned on.
- The on/off button turns green
- The fan inside the unit turns on.
- The light sensor will determen or the room is in day or nightmode.
In daymode the windows with the sun turn
green (night is black) and there will be an indication or the unit is cooling
or not cooling and or there is a demand to dehumidify when not cooling. (Note:
The unit always dehumidifies when cooling)In nightmode the
windows with the moon turn green (day is black) and there will be an
indication or the unit is cooling or heating and or there is a demand to
dehumidify when not cooling. (Note: The unit always dehumidifies when cooling)
By touching the home button you can go to the advanced screen and you can see
more parameters displayed and also a simple datalog window. The settings for
temperature and humidity is the same as in the basic screen. Home – Advanced
Screen
By touching the home button you can go to the advanced screen and you can see
more parameters displayed and also a simple datalog window. The settings for
temperature and humidity is the same as in the basic screen.
Remote control via AnyDesk
The Revomax can be remotely controlled using any device connected to the
internet. The remote controller uses the Anydesk application by default and
you can access the unit using MIFI (modum using a sim card), Hotspot on a
mobile cellphone, WIFI and LAN.
In a LAN setup, connect the LAN cable between the Smart Remote Controller and
you modem or router. Connect the Smart Remote Cont oller to the network.
Go to Menu > Settings > User preferences > Remote AccessTap “Wi-Fi” to open Network & Internet settings and connect to
your internet access-point. You can skip this step if you use wired internet.
In a wireless setup (MIFI, Hotspot or MIFI) use the manual of the wireless
device you are using and connect through Anydesk.
REMOTE CONTROL VIA ANYDESK
Tap “Set password”Click “Unlock Security Settings …”
Tap the password field to open the on-screen keyboard.
Unfortunately this obscures the password field, but that does not matter. Enter
the password, which is either Maxi Controller for the smart remote controller
with the golden startup logo or Revomax for the smart remote controller with
the silver startup logo (the first letter must be uppercase). Press Enter , or
close the keyboard and tap “Yes”.Tap “Set Password…”Enter the password you want to use to remotely access
his controller in both fields and close the keyboard.
Then tap on the “Permission Profile” box and change it to “Unattended Access”
(This is important!)Close both the settings panels by
tapping the cross in the top right, then tap “Show ID”Enter this number into the AnyDesk client (installed in the
previous section) and press connect. You can now close the AnyDesk panels on
the controller. Use your AnyDesk client to test remote access to your
controller now. It may take a minute before the connection succeeds.
If you get “Client Offline” you have mystyped the number or either your
controller or AnyDesk client has lost internet connection. Do not attempt the
option “Power On” as this has no effect.When connection succeeds, the controller
shows the incoming connection. There’s no need to press Accept on the
controller; entering the password on the AnyDesk client will do the same. Your
client will remember the 9-digit ID from now on.
Additional accessories (sold separately)
Electric solenoid valve
The plug of the solenoid valve should be connected using the black cable
supplied with the unit, as shown in the illustration below.The other end of the
cable is connected to the circuit board (see picture). The third connection of
the solenoid valve can be used as earthing.
ADDITIONAL ACCESSORIES
Water leakage sensor
The connection set contains a loose, 5m long white wire: the water leakage
sensor. This sensor is connected to the terminal on the printed circuit-board.
The sensor cable should be led to the outside through the opening in the panel
and should be placed on the ground at the lowest point. The end of the sensor
cable can be split into several cores using a connector, so that more than one
point is secured against leakage.
If the sensor has a black cap, this should be cut back and stripped 5mm and
the cores should be stripped. Connect the other side to the little white plug
on the printed circuit-board as shown in the illustration. In case of water
leakage, the water supply will be stopped immediately by means of the
electrical valve in the water pipe.
www.theclimatefactory.com
info@theclimatefactory.com
References