INTERMATIC FM1D20 Series 24 Hour or 7 Day 120V Electronic Panel Mount Module Instruction Manual
- June 4, 2024
- Intermatic
Table of Contents
FM1D20 Series 24-Hour or 7-Day 120V Electronic Panel Mount Module
Instruction Manual
Safety precautions
Safety precautions
- The connection and installation of electrical devices may only be carried out by a qualified electrician.
- Interventions in and changes to the device result in the voiding of the warranty claim.
- Observe your national regulations and the respective safety provisions.
- Switch-off commands have priority over switch-on commands.
Program structure
![INTERMATIC FM1D20 Series 24 Hour or 7 Day 120V Electronic Panel Mount Module
- Figure 1](https://manuals.plus/wp-content/uploads/2022/10/INTERMATIC- FM1D20-Series-24-Hour-or-7-Day-120V-Electronic-Panel-Mount-Module- Figure-1.jpg)
Symbols, keys
| : Overview of daily switching program
: Setting of 24h or am/pm
: Summer/winter clock changes
: Weekday display
: Switching status display ON/OFF
---|---
+/-| : Adjustment keys: By pressing the key longer than 2 sec. you can adjust
the timer in steps of 5 units
---|---
Res.| : Reset
Menu| : By pressing the menu key programming is terminated and the system
reverts to automatic operation
OK| : Confirmation of programming
Setting the timer
The setting of this programmable timer is depending of the user’s preference
to use pre-set programs or defining own programming.
Using Pre-set programs (first-time installation)
Using the Reset key you can adjust the following values:
24h or am/pm:
Time (hour and minutes):
Weekday:
Pre-set programs P01 to P03:
User-defined programming by Menu mode
Using the Menu key you can adjust/review the following values:
24h or am/pm:
Time (hour and minutes):
Weekday:
Programs P–:
Setting 24h or am/pm clock, time and weekday
Sequence to follow after selecting programming by pre-set programs or Menu mode.
Pre-set programs
Programs P01-03
The switching on and off times for programs P01 to P03 are preset (pre).
The user can change these programs.
The individual program, P-Under the menu option P– you have the option of
creating a user-defined program.
This program can be changed at any time. There are up to 20 memory locations
available for 10 OFF and 10 ON commands.
You can allocate a corresponding weekday or week block to each memory
location.
Selecting pre-set programs P01 to P03
Sequence to follow after setting time in the Reset mode.
![INTERMATIC FM1D20 Series 24 Hour or 7 Day 120V Electronic Panel Mount Module
- Figure 9](https://manuals.plus/wp-content/uploads/2022/10/INTERMATIC- FM1D20-Series-24-Hour-or-7-Day-120V-Electronic-Panel-Mount-Module- Figure-9.jpg)
Once selected the program is desired there are the following options:
Menu: terminate programming
OK: Going through pre-set programs to modify selection (any program
ON or OFF can be modified by using ”+” or ”-” keys and confirming with OK ) or
accepting it with the OK key to go to the next free memory location in order
to add new user-defined pro- grams (see pg 30).
e.g. after selecting P02 you should also program: Sa-Su 22:30 ON (prog05)
23:00 OFF (prog06)
User-defined programs
Sequence to follow after setting time and weekday while running Menu mode or adding programs to the pre-set P01 to P03.
![INTERMATIC FM1D20 Series 24 Hour or 7 Day 120V Electronic Panel Mount Module
- Figure 11.](https://manuals.plus/wp-content/uploads/2022/10/INTERMATIC- FM1D20-Series-24-Hour-or-7-Day-120V-Electronic-Panel-Mount-Module- Figure-11..jpg)
Shift
Should the OFF command be the following day of the ON command then select the
”+” key then select Menu or OK.
Example:
Mo-Fr
20:00 p.m. – 03:00 a.m. ON
03:00 a.m. – 20:00 p.m. OFF| Mo-Fr
20:00 p.m. – 03:00 a.m. ON
Tu-Sa
03:00 a.m. – 20:00 p.m. OFF
---|---
![INTERMATIC FM1D20 Series 24 Hour or 7 Day 120V Electronic Panel Mount Module
- Figure 14](https://manuals.plus/wp-content/uploads/2022/10/INTERMATIC- FM1D20-Series-24-Hour-or-7-Day-120V-Electronic-Panel-Mount-Module- Figure-14.jpg)
Deleting programs
Select Menu, then select the OK key until getting to the ON time of the program you want to delete.
![INTERMATIC FM1D20 Series 24 Hour or 7 Day 120V Electronic Panel Mount Module
- Figure 16](https://manuals.plus/wp-content/uploads/2022/10/INTERMATIC- FM1D20-Series-24-Hour-or-7-Day-120V-Electronic-Panel-Mount-Module- Figure-16.jpg)
Note:
Switching programs are deleted in ON-OFF pairs. If you delete a single ON
instruction, the corresponding OFF instruction is also deleted.
Daylight Savings time
![INTERMATIC FM1D20 Series 24 Hour or 7 Day 120V Electronic Panel Mount Module
- Figure 18](https://manuals.plus/wp-content/uploads/2022/10/INTERMATIC- FM1D20-Series-24-Hour-or-7-Day-120V-Electronic-Panel-Mount-Module- Figure-18.jpg)
The +1h key is for the change to daylight savings time.
- By pressing the +1h key 1 hour is added to the current time.
- +1h is shown on the display.
- By pressing +1h again 1 hour is subtracted from the current time.
Automatic
![INTERMATIC FM1D20 Series 24 Hour or 7 Day 120V Electronic Panel Mount Module
- Figure 19](https://manuals.plus/wp-content/uploads/2022/10/INTERMATIC- FM1D20-Series-24-Hour-or-7-Day-120V-Electronic-Panel-Mount-Module- Figure-19.jpg)
WARRANTY
Warranty service is available by either (a) returning the product to the dealer from whom the unit was purchased or (b) completing a warranty claim online at www.intermatic.com. This warranty is made by: Intermatic Incorporated, 1950 Innovation Way, Suite 300, Libertyville, IL 60048. For additional product or warranty information go to: http://www.Intermatic.com or call 815-675-7000.
INTERMATIC INCORPORATED
Libertyville, IL 60048
158–02264
Documents / Resources
|
INTERMATIC FM1D20 Series 24 Hour or 7 Day 120V Electronic Panel Mount
Module
[pdf] Instruction Manual
FM1D20 Series, 24 Hour or 7 Day 120V Electronic Panel Mount Module, FM1D20
Series 24 Hour or 7 Day 120V Electronic Panel Mount Module, 120V Electronic
Panel Mount Module, Electronic Panel Mount Module, Panel Mount Module, Mount
Module, Module
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>