VUZIX 492 Shield Smart Glasses User Manual

June 4, 2024
VUZIX

VUZIX 492 Shield Smart Glasses User Manual

Overview

Whats include

Charging

Your 7uzix Shield™ is shipped with a partial charge, It is recommended that the battery be fully charged for first time use,
To charge the device, connect the USB-C Port to a USB 5V power source with the USB-C cable

Power on

To power the device on, press and hold the Power Button on the bottom of the right temple for 3 secondsi

Powering Off

To power the device off, press and hold the Power Button for 3 secondsi
Select and tap “Power Off” from the menui

Battery State

If the device does not power on, the following icons may appear:

Touchpad Gestures

Touchpad Gestures, CONTINUED

Home

 Launcher

On boot-up, Home will display automatically with the Launcher selectedi Swipe left/right to select an app, tap to launchi
Note: Actual interface and icons may vary,

Notifications

Quick Settings

To navigate to Notifications or Quick Settings, swipe down from the Launcher, left/right to select the icon, then one-finger tapi
Note: Actual interface and icons

WiFi Quick Connect

The easiest and fastest method to connect your Vuzix smart glasses to WiFi is by using a QR code:
Visit www.vuzix.com/wifiQR on your phone or computer to securely generate a QR code for your WiFi settings.
Launch the Scanner app on your smart glasses and look at the QR code to connect to your network.

Applications / Standards

The Vuzix Shield safety spectacles are designed to protect the user against eye injuries through mechanical impact and flying particlesi The Vuzix safety spectacles will ensure a secure and comfortable fit and protect against common hazardsi
This product can be used in a wide range of applications including:

  • Construction
  • Engineering
  • eneral assembly
  • Inspection work
  • Light duty maintenance and repair

These safety spectacles do not provide unlimited eye protectioni For your own protection read these instructions completely before using this eye protectioni
This protective eyewear has been shown to meet the basic safety requirements under Directives 2001/95/EC and comply with the requirements of (EU) Regulation 2016/425i This
product has been examined at the design stage by DIN CERTCO esellschaft für Konformitätsbewertung mbH,
Alboinstri 56, 12103 Berlin, ermany; Notified Body: 0196i This product was tested, and approved against EN 166:2001 and EN 170:2002 ANSI_ISEA Z87i1:2015i
The applicable regulations can be viewed at the EU Declaration of Conformity link: https://www.vuzix.com/support/legal4

Eye Protection Marking

prune Markings

Note: If the symbols of the marking are not common to different parts of the protection equipment, the lower protection level shall be assigned to the complete protection equipment,
Note: If the General Field of Use is not a T, then the eye protector shall only be used against high speed particles at room temperature,

Optical Quality and Useful Life

The Vuzix Shield design provides excellent coverage and good field of visioni

Optical class 1 lenses are particularly suitable when a high level of visual performance is required while protecting the human eye against damage that could result in defective vision, even when worn for prolonged periods of timei

EN166 Optical properties

Optical class Class 1 Class 2 Class 3
Spherical refractive power
± 0.06 dpt. ± 0.12 dpt. ± 0.12, -0.25 dpt.
Astigmatic reflective power

± 0.06 dpt. ± 0.12 dpt. ± 0.25 dpt.
When stored correctly at a cool and dry place without use, the maximum lifetime of a safety eyewear product is 6 yearsi Depending on the intensity of use and wear caused by external influences, the maximum life of a product is 2 yearsi If protective eyewear has been scratched or otherwise damaged it must be replacedi

General Warnings

  • Always perform a visual inspection of the glasses prior to
  • Pitted or scratched lenses reduce vision and seriously reduce protection and should be immediately
  • Eye and face protectors that have been subjected to an impact should not be used and should be discarded and
  • This product is for eye protection against moderate impact hazards but is not
  • Do not use this product against hazards other than those specified in this
  • Do not modify or alter the
  • Always check with supervisory personnel to ensure you are being given the proper protection relative to working
  • No parts of the safety spectacles which are in contact with wearer are made of materials which are known to cause any skin The material of the eye-protection, which is directly in contact with skin, will not do any harm to the skin. But to those who are easily allergic, there might be allergic reactions.
  • Safety spectacles that protect against high speed particles worn over ophthalmic spectacles may transmit impacts, thus creating a hazard to the
  • In accordance with EN 166:2001 and EN 170:2002 safety spectacles cannot be tested and approved for use against liquid Where liquid protection is specified a suitable product should be considered, for example safety goggles.
  • This product is not suitable for grinding or

This eye protector only protects against physical hazards

Cleaning

Treat your Shield as you would any quality eyeweari It is mostly maintenance free and only requires to be wiped down periodically, using only a microfiber cloth to clean the devicei
Caution: Do not spray with cleaners, If required, use microfiber cloth moistened with standard eyeglass cleaner, Avoid spills, Solvents, household cleaners and paper towels should never be used on your 7uzix Shield,
Caution: 7uzix Shield is not water resistant, Avoid submerging or exposure to moisture, Excessive moisture will damage the device,
Caution: Do not pack loose objects in the zipper case with the Shield, hoose objects may cause damage to the device,

Climate Usage

SAR limits are usually expressed in units of W/kgi Shield has been tested at its highest transmission
levels and placed in a position that simulates use against the head with no separationi
Shield maximum determined SAR value over all possible transmission modes is 1i06 W/kg, averaged over 1gm of tissuei

Support

For further documentation and support scan the QR code or visit vuzix.com/pages/shield-support
For safety, warranty and regulatory
information, go to the Vuzix legal page at:www.vuzix.com/support/legal

SCAN QR FOR SUPPORT
For more information on Vuzix products and accessories visit:
vuzix.com | vuzix.eu | vuzix.uk | vuzix.jp
Vuzix Corporation

25 Hendrix Road
West Henrietta, NY, USA 14586
UK Importer – Vuzix (Europe) Limited St. John’s House, 5 South Parade Summertown, Oxford, OX2 7JL
© 2022 Vuzix Corporation. These instructions are subject to change. Please read the Safety and Warranty booklet before operating this product. All trademarks belong to the respectve owners

FCC and ISED Compliance

This device complies with part 15 of the FCC Rules and with the Radio Standards Specifications (RSS) for licence‐exempt transmitters/receivers of Innovation, Science and Economic Development Canada (ISED). Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving
  • Increase the separation between the equipment and
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is
  • Consult the dealer or an experienced radio/TV technician for

This equipment complies with the FCC(US) and ISED(CAN) radio frequency (RF) exposure limits set forth for an uncontrolled environment, when used as intended, described and instructed in the user guidance. User guidance is part of the delivered package and provided through our home page. SAR limits are usually expressed in units of W/kg.
The Vuzix Shield has been tested at its highest transmission levels and placed in a position that simulates use against the head with no separation
The maximum determined SAR value over all possible transmission modes is 1.06 W/kg, averaged over 1g of tissue.

Canada

The installer of this radio equipment must ensure that the antenna is located or pointed such that it does not emit RF field in excess of Health Canada limits for the general population; consult Safety Code 6, obtainable from Heath Canada’s website: https://www.canada.ca/en/h ealth‐canada/services/environmental‐workplace‐health/reportspublications/radiation/understanding‐safety‐code‐6.htm l
Operation of 5150-5350 MHz is restricted to indoor use only.

Read More About This Manual & Download PDF:

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

VUZIX User Manuals

Related Manuals