KeepRite REFRIGERATION KEH A 006-L-H Generation C Condensing Units User Guide
- May 15, 2024
- KeepRite REFRIGERATION
Table of Contents
- PRICE LIST
- KEH-LINE, “C” GENERATION INDOOR AND OUTDOOR AIR COOLED HERMETIC
- KEZ-LINE, “C” GENERATION INDOOR AND OUTDOOR AIR COOLED SCROLL CONDENSING
- KES-LINE, “C” GENERATION INDOOR AND OUTDOOR
- KEH/S/Z-LINE “C” GENERATION CONDENSING UNITS – FACTORY INSTALLED OPTIONS
- PRODUCT SUPPORT RESOURCES
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
“C” GENERATION
SMALL CONDENSING UNITS
VOL 2C
PRICE LIST
EFFECTIVE DATE:
01 MARCH 2023
SUPERCEDES:
KLP-2022-3
Bulletin KLP-2023-2C
Part # 1090869-2C
http://docs.k-rp.com/1090869-2.pdf
Prices are F.O.B. shipping point. Freight is allowed via lowest common carrier
to nearest freight station in Canada and U.S.A. (except to Alaska or Hawaii)
on shipments of $7000 NET or more.
Shipments of less than $7000 NET are F.O.B. shipping point and are not freight
allowed. Prices, weights and specifications subject to change without notice.
Terms: Net 30 days. Subject to Terms and Conditions of Sale / General Warranty
/Claims Procedures
INCLUDES MODELS FOR DOE & NRCAN
AWEF- EXEMPT APPLICATIONS
KEH-LINE, “C” GENERATION INDOOR AND OUTDOOR AIR COOLED HERMETIC
CONDENSING UNITS
web: www.k-rp.com/keh
email: smcu@k-rp.com
call: 1-844-893-3222 x521
NOMENCLATURE
A = Standard Features (see below)
B = Standard Features (see below)
Plus Sealed Liquid Line Filter Drier and Sight Glass
C = Standard Features (see below)
Plus Sealed Liquid Line Filter Drier and Sight Glass
Plus Suction Accumulator
Plus Electric Defrost Kit
D = Standard Features (see below)
Plus Sealed Liquid Line Filter Drier and Sight Glass
Plus Heated and Insulated Receiver
E = Standard Features (see below)
Plus Sealed Liquid Line Filter Drier and Sight Glass
Plus Heated and Insulated Receiver
Plus Suction Accumulator
Plus Electric Defrost Kit
F = Standard Features (see below)
Plus Sealed liquid line filter drier and sight glass
Plus Electric Defrost Kit
G = Standard Features (see below)
Plus Sealed liquid line filter drier and sight glass
Plus Electric Defrost Kit
Plus Heated and insulated receiver
H = Standard Features (see below)
Plus Sealed Liquid Line Filter Drier and Sight Glass
Plus Timeclock
J = Standard Features (see below)
Plus Sealed Liquid Line Filter Drier and Sight Glass
Plus Heated and insulated receiver
Plus Suction Accumulator
Please see pages 17-19 for complete details of available factory installed
options
KEH-LINE, “C” GENERATION INDOOR AND OUTDOOR AIR COOLED HERMETIC CONDENSING UNITS
STANDARD FEATURES
Indoor Unit:
-
Weatherproof electrical control box with compressor contactor and fused control circuit
-
Welded-hermetic compressor
-
High efficiency enhanced tube and fin condenser design
-
Pre-formed piping
-
Quiet fan motor operation
-
Energy efficient PSC condenser fan motor
-
Electrical control panel away from air flow stream
-
Wide-open front design, spring latches and handle on 5Hp MT & HT or larger
-
Unit leak tested and shipped with helium holding charge
-
Painted cabinet
-
Receiver with fusible plug and liquid shut off valve
-
Suction service valve
-
Copper tubing secured with cushion clamps
-
Fixed high and low pressure control
Outdoor Unit: All Standard Features of Indoor Unit, Plus: -
Painted weather-resistant housing with removable hood
-
Flooded head pressure control (non adjustable)
-
Crankcase heater
AVAILABLE OPTIONS
- Sealed suction filter
- Suction accumulator
- Suction accumulator with boil-out coil
- Heated and insulated receiver
- Sealed liquid line filter drier and sight glass
- Liquid line solenoid valve with 230-volt coil (shipped loose)
- Compressor circuit breaker
- Compressor time delay relay
- Variable speed EC motors only as head pressure control (see Bulletin K40-HPC-AG or https://docs.k-rp.com/1101110.pdf for details)
- Quick Vac Evacuation and Refrigerant Recovery Valves
- Smart Speed Fan Motor Technology
- Pump down toggle switch
- Electric defrost kit with mechanical time clock and contactors, as required
- Hoffman variable fan speed control
- Lockout control circuit relay (for liquid solenoid valve)
- Disconnect switch (fused or non-fused)
- Electronic phase / voltage monitor
- Leg kit or air discharge hood
MEDIUM TEMPERATURE – R404A R507 R407C R448A R448A
LOW TEMPERATURE – R404A R507
KEZ-LINE, “C” GENERATION INDOOR AND OUTDOOR AIR COOLED SCROLL CONDENSING
UNITS
NOMENCLATURE
STANDARD FEATURES
Indoor Unit:
-
Compatible with Low GWP Refrigerants
-
Weatherproof electrical control box with compressor contactor and fused control circuit
-
Copeland scroll compressor
-
High efficiency enhanced tube and fin condenser design
-
Energy efficient PSC condenser fan motor
-
Receiver with fusible plug and liquid shut off valve
-
Suction service valve
-
Pre-formed copper tubing
-
Liquid injection (low temp. models)
-
Unit leak tested and shipped with helium holding charge
-
Fixed high pressure switch and adjustable low pressure control
-
Receiver inlet valve on 2-fan units models only
-
Discharge thermostat on applicable models only
Painted cabinet -
Anti-short cycle time delay relay
Outdoor Unit: All Standard Features of Indoor Unit, Plus:
- Painted weather-resistant housing with removable hood
- Flooded head pressure control (non adjustable) 150 PSIG for optimal efficiency
- Crankcase heater
- Fan cycling control with flex hose (2 fan units)
AVAILABLE OPTIONS
- Suction accumulator with and without boil-out coil
- Discharge line check valve
- Oil separator with and without oil return filter and solenoid valve
- Adjustable flooded head pressure control valves
- Receiver inlet ball valve
- Heated and Insulated receiver
- Over-sized receiver
- Sealed liquid line filter drier & sight-glass
- Ball valve – liquid line (shipped loose)
- Insulated suction lines
- Leg kits
- Discharge air hood
- Sub cooling circuit on 5 – 17 HP models
- Liquid line solenoid valve (with standard 230 volt coil) – shipped loose
- Variable speed EC motors only as head pressure control (see Bulletin K40-HPC-AG or https://docs.k-rp.com/1101110.pdf for details)
- QuickVac Evacuation and Refrigerant Recovery Valves
- Dual pressure control with flex hoses
- Compressor circuit breaker
- Current sensing relay – for use with oil safety control (where applicable)
- Defrost heater contactor c/w fuse block
- Evaporator fan contactor c/w fuse block
- Disconnect switch
- Disconnect fusing
- Pump down toggle switch
- Lock out control circuit relay
- Hoffmann speed control for condenser fan (replaces flooded valve)
- Mechanical time clock
- Electronic voltage / Phase monitor
- Smart Speed Fan Motor Technology
- Limitrol+ Floating Head Pressure Control System (see Bulletin K40-LIMITROL-AG or https://docs.k-rp.com/1101113.pdf for details)
KES-LINE, “C” GENERATION INDOOR AND OUTDOOR
AIR COOLED SEMI-HERMETIC CONDENSING UNITS
NOMENCLATURE
STANDARD FEATURES
Indoor Unit:
- Compatible with Low GWP Refrigerants
- Weatherproof electrical control box with compressor contactor and fused control circuit
- Spring mounted accessible semi-hermetic compressor with suction and discharge vibration eliminator
- High efficiency enhanced tube and fin condenser design
- Energy efficient PSC condenser fan motor
- Receiver with fusible plug and liquid shut off valve
- Fixed high pressure switch and adjustable low pressure control
- Receiver inlet and outlet shutoff valve (8HP and above)
- Suction service valve
- Pre-formed copper tubing
- Unit leak tested and shipped with Helium holding charge
- Electronic liquid injection on L8 units
- Painted cabinet
Outdoor Unit: All Standard Features of Indoor Unit, Plus:
- Painted outdoor weather-resistant housing with removable hood
- Flooded head pressure control (non adjustable) 150 PSIG for optimal efficiency
- Adjustable head pressure control on large 2 fan models
- Crankcase heater
- Fan cycling control (all 2 fan models)
AVAILABLE OPTIONS
- Suction accumulator
- Suction accumulator with boil-out coil
- Discharge line Check valve
- Oil separator
- Oil separator c/w oil return filter & solenoid valve
- Adjustable head pressure control valves
- Receiver inlet ball valve (standard on 2 fan models)
- Heated and Insulated receiver
- Over-sized receiver
- Sealed liquid line filter drier & sight-glass
- Ball valve – liquid line (shipped loose)
- Insulated suction lines
- Leg Kits
- Discharge air hood
- Sub cooling circuit on 5 – 22 HP models
- Variable speed EC motors only as head pressure control (see Bulletin K40-HPC-AG or https://docs.k-rp.com/1101110.pdf for details)
- QuickVac Evacuation and Refrigerant Recovery Valves
- Liquid line solenoid valve-(with standard 230 volt coil)-shipped loose
- Compressor Circuit breaker
- Current sensing relay – for use with Oil safety control (where applicable)
- Defrost heater contactor c/w fuse block
- Evaporator Fan contactor c/w fuse block
- Disconnect switch
- Disconnect Fusing
- Pump down toggle switch
- Lock out control circuit
- Hoffmann Speed control for condenser fan (replaces flooded valve)
- Time delay relay for compressor
- Mechanical Time Clock
- Defrost Kit
- Electronic Voltage/Phase Monitor
- Smart Speed Fan Motor Technology (see page 4)
- Limitrol+ Floating Head Pressure Control System (see page 5 or Bulletin K40-HPC-AG or https://docs.k-rp.com/1101113.pdf for details)
LOW TEMPERATURE – R404A R507 R448A R448A
LOW TEMPERATURE – R404A
LOW TEMPERATURE – R407A R448A
MEDIUM TEMPERATURE – R404A R507 R448A R448A
LOW TEMPERATURE – R404A R507
LOW TEMPERATURE – R448A R407A
KEH/S/Z-LINE “C” GENERATION CONDENSING UNITS – FACTORY INSTALLED OPTIONS
OPTION PACKAGES – ALL COMPRESSOR MODELS
Option Package | HP (Size) | Price |
---|
PACKAGE “A” STANDARD UNIT includes:
● High efficiency PSC fan motors ● Fan Guard ● Enhanced tube condenser coil ●
Adjustable low pressure control
● Copper tubing secured with cushion clamps ● Receiver outlet valve ●
Flooded head pressure control (STD on Outdoor models) ● Crankcase heater (STD
on Outdoor models)| All MODELS| STD.
PACKAGE “B” includes:
– All items in Package “A” + Sealed liquid line filter drier and sight glass|
0.5 – 2.9| 656
3.0 – 12| 763
15 +| 1051
PACKAGE “C” includes:
– All items in Package “A” + Sealed liquid line filter drier and sight glass
+ Electric Defrost Kit(40A max on Htrs) + Suction accumulator| 0.5 – 2.9|
2064
3.0 – 7.5| 2555
7.6 – 12| 3467
15 +| 4827
PACKAGE “D” includes:
– All items in Package “A” + Sealed liquid line filter drier and sight glass
+ Heated and insulated receiver| 0.5 – 2.9| 1110
3.0 – 7.5| 1761
7.6 – 12| 2115
15 +| 2576
PACKAGE “E” includes:
– All items in Package “A” + Sealed liquid line filter drier and sight glass
+ Electric Defrost Kit (40A max on Htrs) + Suction accumulator
+ Heated and insulated receiver.| 0.5 – 2.9| 2518
3.0 – 7.5| 3553
7.6 – 12| 5108
15 +| 6092
PACKAGE “F” includes:
– All items in Package “A” + Sealed liquid line filter drier and sight glass
+ Electric Defrost Kit (40A max on Htrs)| 0.5 – 2.9| 1538
3.0 – 12| 1644
15 +| 1932
PACKAGE “G” includes:
– All items in Package “A” + Sealed liquid line filter drier and sight glass
+ Electric Defrost Kit (40A max on Htrs) + Heated and insulated receiver.|
0.5 – 2.9| 1991
3.0 – 7.5| 2642
7.6 – 12| 2996
15 +| 3457
PACKAGE “H” includes:
– All items in Package “A” + Sealed liquid line filter drier and sight glass
+ Timeclock.| 0.5 – 2.9| 1356
3.0 – 12| 1462
15 +| 1750
PACKAGE “J” includes:
– All items in Package “A” + Sealed liquid line filter drier and sight glass
+ Heated and insulated receiver + Suction accumulator.| 0.5 – 2.9| 1637
3.0 – 7.5| 2672
7.6 – 12| 3939
15 +| 5211
- Electric Defrost Kit includes: Timeclock, defrost heater contactor (40A max.) and fan motor contactor (30A if required depending on matched evaporator)
Individual Options| HP (Size)|
List Price $
---|---|---
Weather hood housing (STD on Outdoor models)| Cabinet A| 530
Cabinet B| 649
Cabinet C| 762
Cabinet D| 1398
Cabinet E| 1539
Cabinet F| 1914
Sealed liquid line filter drier and sight glass| 0.5 – 2.9| 656
3.0 – 12| 763
15 +| 1051
Replaceable Core liquid line filter drier and sight glass| 2.9 – 12| 1073
15 +| 1312
Suction accumulator without heat exchanger| 0.5 – 2.9| 527
3.0 – 7.5| 912
7.6 – 12| 1824
15 +| 2635
Suction accumulator with heat ex- changer| 0.5 – 2.9| 738
3.0 – 7.5| 1264
7.6 – 12| 2527
15 +| 4781
Sealed suction filter| 0.5 – 2.9| 421
3.0 – 7.5| 592
7.6 – 12| 1072
15 +| 1389
Replaceable core suction filter| 2.9 – 7.5| 1139
7.6 – 12| 1394
15 +| 2475
Discharge line check valve| 0.5 – 6.1| 515
7.6 – 12| 708
15 +| 771
Two valve adjustable flooded head pres- sure control| All Models| 794
Oil separator| 2.9 – 7.5| 1258
7.6 – 22| 1769
Oil separator c/w oil filter and solenoid valve| 2.9 – 4.0| 1590
5.0 – 7.5| 1665
7.6 – 15| 2177
20 +| 2537
Oversized Receiver| 0.5 – 2.9| 995
3.0 – 12| 1210
15 +| 1352
Heated and insulated receiver| 0.5 – 2.9| 453
3.0 – 7.5| 998
7.6 – 12| 1353
15 +| 1526
Receiver inlet ball valve| 7.5 HP and below| 579
Liquid line solenoid valve with 230 volt coil (Shipped loose)| 0.5 – 5.0| 650
6.0 – 7.6| 727
8 +| 1192
Individual Options| HP (Size)|
List Price $
---|---|---
Adjustable pressure controls with flex hose
Adj Dual Pressure Control (Danfoss)| All Models| 384
Adj Dual Pressure Control (Johnson)| All Models| 847
Separate Johnson Low Pressure and High Pressure Controls| All Models| 1168
Ball valve (Shipped loose)| All Models| 298
Current Sensing Relay (for use w/oil safety control)| All Models| 765
Compressor circuit breaker| 0.5 – 4.0| 1587
5.0 – 7.5| 2972
7.6 +| 4614
Compressor time delay relay| All Models| 391
Pump down toggle switch| All Models| 298
Lock-out control circuit (for liquid line solenoid)| All Models| 1088
Mechanical Time Clock| All Models| 700
30A or 40A Contactor| All Models| 442
60A Contactor| All Models| 608
Electric Defrost Kit*:
1 Evap per Compressor| Up to 40A Htr, 30A Fans| 881
Up to 60A Htr, 30A Fans| 1048
Up to 80A Htr, 30A Fans| 2283
2 Evaps per Compressor| Up to 40A Htr, 30A Fans| 1323
Up to 60A Htr, 30A Fans| 1645
Up to 80A Htr, 30A Fans| 3222
3 Evaps per Compressor| Up to 60A Htr, 30A Fans| 3318
Up to 80A Htr, 30A Fans| 4476
Hoffman variable fan speed control
(replaces flooding valve) Recommended for use in mild ambients only| All
Models| 2687
Non-fused disconnect| 208 – 230| 834
460 – 575| 975
Disconnect fusing| All Models| 493
3-Lead Phase / voltage monitor| All Models| 696
6-Lead Phase / voltage monitor| All Models| 1381
Discharge Air Hood (Angled front) OR
Hail Guard (Angled Condenser Cover) OR
Wind Guard (if required, used only with ECM on open roof)| Cabinet A| 467
Cabinet B| 498
Cabinet C| 525
Cabinet D| 609
Cabinet E| 653
Cabinet F| 730
8” Leg Kit (factory mounted)| 0.5 – 2.9| 389
3.0 – 7.5| 504
7.6 +| 756
KEH/S/Z-LINE CONDENSING UNITS – FACTORY INSTALLED OPTIONS
OPTIONAL FIN MATERIAL/COATINGS –
HORIZONTAL AIR COOLED CONDENSING UNITS
**CABINET SIZE *| “Gold Coat Fin”| Copper Fin**|
E-COAT
---|---|---|---
A| 767| Consult Factory for Pricing| 6188
B| 1157| 6188
C| 1545| 7842
D| 1644| 8628
E| 2003| 9095
F| 2620| 10403
FOR KE-LINE CONDENSING UNITS
CABINET| VOLTAGE| | WITH HEATED & INSULATED RECEIVER|
WITH HEATED & INSULATED RECEIVER WITH WIND GUARD
---|---|---|---|---
CABINETS A, B, C| 230V| –| –| –
460V/575V| –| –| –
CABINET D| 230V| 3830| 4828| 5909
460V/575V| 5122| 6121| 7201
CABINET E| 230V| 5808| 7160| 8265
460V/575V| 7057| 8409| 9514
CABINET F| 230V| 7454| 8978| 10160
460V/575V| 10343| 11868| 13049
EC MOTORS FOR KE-LINE CONDENSING UNITS
CABINET
(see table below)| |
VARIABLE SPEED
---|---|---
230V| 230V| 460V| 575V
A| 290| 515| 2189| 2189
B| 441| 762| 2629| 2629
C| 441| 693| 1206| 2560
D| 441| 693| 1206| 2560
E| 882| 1227| 2255| 4515
F| 1461| 1744| 2402| 5032
HERMETIC
MODEL (Copeland)|
CHASSIS
---|---
KEHA006M8| A
KEHA008M8
KEHA009M8
KEHA010M8
KEHA011M8
KEHA013M8| B
KEHA015M6| B
KEHA020M6
KEHA025M6
KEHA029M6
KEHA030M6| C
KEHA035M6
KEHA006L6| A
KEHA008L6
KEHA010L6
KEHA015L6
KEHA020L6
KEHA025L6| B
KEHA030L6
SCROLL
MODEL (Copeland)
|
CHASSIS
---|---
KEZA008L8| A
KEZA010L8
KEZA015L8
KEZA020L8
KEZA025L8| B
KEZA030L8
KEZA035L8
KEZA045L8| C
KEZA055L8
KEZA060L8
KEZA075L8| D
KEZA085L8
KEZA100L8
KEZA130L8| E
KEZA150L8
KEZA170L8| F
SEMI-HERMETIC
MODEL (Copeland)| MODEL (Bitzer)|
CHASSIS
---|---|---
KESA010M8| —–| A
KESA020M8| —–| B
KESA021M8| —–
KESA030M8| —–| C
KESA005L8| —–| A
KESA008L8| —–
KESA010L8| KESB010L 6/8
KESA015L8| KESB015L 6/8| B
KESA020L8| KESB020L 6/8
KESA021L8| KESB025L 6/8
KESA030L8| KESB030L 6/8| C
KESA032L8| KESB031L 6/8
KESA035L 6/8| —–
KESA040L 6/8| KESB039L 6/8
—–| KESB050L 6/8| D
KESA060L 6/8| KESB060L 6/8
KESA061L 6/8| —–
KESA075L 6/8| —–
KESA090L 6/8| KESB080L 6/8| E
KESA100L 6/8| KESB100L 6/8
—–| KESB120L 6/8
KESA120L 6/8| —–| F
KESA130L 6/8| —–
KESA150L 6/8| —–
KESA220L 6/8| —–
PRODUCT SUPPORT RESOURCES
PRODUCT SUPPORT| web: www.k-rp.com/support
email: smcu@k-rp.com
call: 1-844-893-3222 x521
---|---
TROUBLESHOOTING| email:
troubleshooting@k-rp.com
call: 1-844-893-3222 x529
SERVICE PART| web: www.k-rp.com/parts
email: parts@k-rp.com
call: 1-844-893-3222 x504
WARRANTY| web: www.k-rp.com/warranty
email: warranty@k-rp.com
call: 1-844-893-3222 x507
ORDERS| email: orders@k-rp.com
call: 1-844-893-3222 x501
| email: shipping@k-rp.com
call: 1-844-893-3222 x503
KeepRite Refrigeration
Brantford, ON • Longview, TX
1-800-463-9517
info@k-rp.com www.k-rp.com
http://www.k-rp.com
Due to the manufacturer’s policy of continuous product improvement, we reserve
the right to make changes without notice.
References
- Commercial Refrigeration Systems & Solutions | KeepRite Refrigeration
- KEH - Indoor/Outdoor Air Cooled Hermetic Condensing Units - KeepRite Refrigeration
- KES - Indoor/Outdoor Air Cooled Semi-Hermetic Condensing Units - KeepRite Refrigeration
- KEZ - Indoor/Outdoor Air Cooled Scroll Condensing Units - KeepRite Refrigeration
- Tech Support, Refrigeration Parts, Manuals & Warranty - KeepRite
- Tech Support, Refrigeration Parts, Manuals & Warranty - KeepRite
- Tech Support, Refrigeration Parts, Manuals & Warranty - KeepRite
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>