Warmme UTR82WE WiFi Thermostat App User Guide
- June 17, 2024
- Warmme
Table of Contents
Warmme UTR82WE WiFi Thermostat App
INSTALL
APP for WiFi thermostat
THERMOSTAT DESCRIPTION
The 82 series is a smart thermostat used to control your electric floor heating system or water heating system. It will keep your home at comfortable tempera- ture whilst minimizing energy use. Install the app on your smart phone to control your electric heating system remotely with the WiFi thermostat.
MAIN FUNCTIONS
- Auto mode
- Holda mode
- Holiday mode
- Anti-frozen function
- Floor temperature limit
- Open window detection function
- Key-lock
- Brightness
- Sensor selection
- Adaptive function
TECHNICAL SPECIFICATION
- Supply voltage: 85-265Vac 50/60Hz
- Standby power: < 2W
- IP rating: IP20
- Max load: 16A(electric heating)/3A(water heating)
- Wire diameter: ≤2.5mm²
DISPLAY SYMBOLS
WIFI CONNECTIONION
FUNCTION & USER OPERATION
On/Off
Press the button ont the right side of the thermostat to turn on/off.
Note : When anti-frozen function is active, the thermostat will maintain
the anti-frozen temperature when power off.
Temporarily override temperature
In the page of detected temperature, press or to change the current event
temperature setting. The thermostat will revert to the parameters of schedule
at the start-time of the next event in auto mode.
Mode selection
In the page of detected temperature, press the key in the up left corner to
select the mode.
There are 3 modes:
Auto mode: It is the default mode. Thermostat runs according to event
parameters set in Edit Setting to save energy.
Steps : Press Auto Mode to confirm and back to the page of detected
temperature.
Manual mode: Thermostat will run with the set temperature for ever.
Steps:
Press Manual Mode to enter temperature setting.
Press Δ or ∇ to set the temperature.
Press done to confirm and enter the page of detected temperature.
Holiday mode: Thermostat will run with the set temperature until the holiday
time ends.
Menu **
**
In the page of detected temperature, press the key ≡ to enter Menu.
There are 5 parameter settings.
Time
Day and clock are set here.
Steps:
- Press Time to enter day setting.
- Press the day you want to enter hour setting.
- PressΔ or ∇to set hour.
- Press to confirm and enter minute setting.
- Press Δ or ∇ to set minute.
- Press done to confirm and back to Menu.
- Press done to back to the page of detected temperature.
- If the thermostat is WiFi version, it will update time automatically after connecting to WiFi.
Key lock
Lock all keys to prevent the settings from being changed.
Lock Steps:
Press Key Lock to enter key lock setting.
Press Δ or ∇ to select lock.
Press done to confirm and back to the page of detected temperature.
Unlock steps:
In the page of detected temperature, press any key then (in the down right
corner) will flash 3 times.
Press and hold for 3 seconds to unlock.
Brightness
This option allows you to change the brightness of the display.
Steps:
Press Brightness to enter brightness setting.
Press done to move up/down or touch any part of the line to set the
brightness.
Press done to confirm and back to Menu.
Edit setting
Edit setting can set and change the parameters. If you don’t choose Holiday
Mode or Hold Mode. The thermostat runs according to the parameters of Edit.
Steps:
Press Edit Setting to enter days selection.
Press the day you want to set.
Press done to enter event selection.
Default parameters
Day | Wake | Leave | Back | Sleep |
---|---|---|---|---|
Mon- Fri | 07:00 | 22.0°C | 08:30 | 19.0°C |
Sat/Sun | 08:00 | 22.0°C | 08:30 | 22.0°C |
Advanced Setting
The thermostat provides advanced settings to suit various special situations.
These are normally set by technicians during initial installation.
Steps:
- Press Advanced Setting to enter the page of warning.
- Press done to enter the page of advanced setting.
- Press Δ or ∇ to switch page.
- Press the item to set its parameters.
No. | Name | Default | Ranges |
---|---|---|---|
1 | Room Temperature Calibration | 0°C | -5°C — 5°C |
2 | Floor Temperature Calibration | 0°C | -5°C — 5°C |
3 | Anti-frozen Switch | ON | ON/OFF |
4 | Anti-frozen Temperature | 5°C | 5°C — 15°C |
5 | Floor Temperature Limit | 30°C | 20°C — 50°C |
6 | Temperature Tolerance | 1°C | 0.5°C/1°C/2°C/3°C |
7 | Temperature Unit | °C | °C/°F |
8 | Sensor Selection | Floor | Room/Floor/Both |
9 | Schedule | 5+1+1 | 5+1+1/7 |
10 | Output Delay | 0 Sec | 0S/30S/60S/90S |
No. | Name | Default | Ranges |
--- | --- | --- | --- |
11 | Adaptive Function | OFF | ON/OFF |
12 | Open Window | OFF | ON/OFF |
13 | Power Set | 0 W | 0W — 4500W |
14 | Energy Use | ||
15 | Sensor Type | 0-3950 | 0-3950 |
1-3380
2-3700
3-3600
4-3740
16| Factory Reset| NO| NO/YES
-
Room Temperature calibration: Calibrate the temperature detected by room sensor.
-
Floor Temperature calibration: Calibrate the temperature detected by floor sensor.
-
3&4. Anti-frozen function: If the Anti-frozen function opened, it will keep the room and floor at a lower temperature in order to protect the pets and plants in your house.
-
Also, it can protect your pipe against freezing when using the water heating system.
-
Floor temperature limit: When choose both sensors, you can set the maximum floor temperature value, system will stop heating if the floor temperature exceed this value.
-
Temperature Tolerance: The value is 1°C. The thermostat start to work when the actual temp is 1°C lower than set temp and stop to work when the actual temp is 1°C higher than set temp.
-
Temp unit: °F and °C can be selected.
-
Sensor selection
Room sensor: Run by room sensor.
Floor sensor: Run by floor sensor.
Both sensors: Run by room sensor with floor temp limit. -
Schedule: Select a weekly schedule for the event.
7: each day from Mon to Sun can be set individually.
5+1+1: Mon to Fri have the same events, Sat and Sun can be set individually. -
Output delay: This option help you avoid inadvertent operation on heating.
-
Adaptive function: After several days of installation and use, Adaptive function ensures that the required temp has already been reached when the next event begins.
-
Open window: This function only works when room sensor or both sensors is selected. The thermostat with this function will shut off automatically for 15 min when the window opens, as it can detect that the room temp plummets.
-
13&14. Energy use: This option allows you to enter the various data used to calculate energy use.
-
13&14. Energy use: This option allows you to enter the various data used to calculate energy use.
-
Sensor Type: This thermostat is compatible with the following five floor temperature sensors. The default sensor 0-3950 is in the box.
Temperature
| The resistance value of the floor sensor at the corresponding temperature
point (Ω)
---|---
0-3950| 1-3380| 2-3700| 3-3600| 4-3740
0 °C| 32800| 26050| 30286| 34423| 34720
10 °C| 19733| 17630| 19055| 22217| 22328
25 °C| 10000| 10000| 10000| 12000| 12000
30 °C| 7905| 8331| 8165| 9869| 9854
16. Factory Reset: All parameters are restored to default values.
TROUBLESHOOTING
Room Sensor Error! : Built-in sensor short-circuit or disconnected.
Floor Sensor Error! : Floor sensor short-circuit or disconnected.
DIMENSION (MM)
INSTALLATION AND WIRING INSTRUCTIONS
Installation
- Step 1 Separate the panel from the back section: insert the screwdriver into two holes under the thermostat and pry it like the picture.
- Step 2 Connect the wire as shown in the wiring instruction.
- Step 3 Fix the back section to switch box with screws provided.
- Step 4 Re-install front panel whilst ensuring the pins engage properly in the circuit board socket.