Specifications

  • Model: SCT016S
  • Input Current: 50A – 200A
  • Output: 100mA
  • Turns Ratio: 1100 – 14000
  • Load Resistance: 5 – 10
  • Accuracy: 0.5% – 1%
  • Linearity: 1%
  • Weight: 85g

OVERVIEW

Ф16mmAperture Split core current transformer

HYDC-SCT016S-50A-Split-Core-Current-Transformer-FIG-1

Characteristic

  • Safety lock buckle, easy to install
  • Built-in over-voltage protection device (TVS tube)
  • Lead type output and length can be customized
  • Suspended type

Product application

  • Portable instrument
  • Household metering
  • Monitor motor load

Product advantage

  • Small volume, lightweight
  • Low cost
  • High turns, high precision

Installation diagram

Primary threading method(Firing line)

Typical technical index

  • Material of core—— Silicon steel sheet
  • Working voltage—— Phase voltage≤720V
  • Working temperature——- 25℃~+60℃
  • Storage temperature——- 30℃~+90℃
  • Frequency range—— 50Hz~60Hz
  • Dielectric strength—— Input(bare conductor)/output AC 800V/1min 5mA 50Hz Output/Outer shell AC 3.5KV/1min 5mA 50Hz

Electrical parameters:( The following parameters are typical values and actual values will be subject to product testing)

 | Max. continuous input current: 120% of rated input|
Model| Input

current

| Output| Turns ratio| Load

resistance

| Accuracy| Linearity| Weight|
SCT016S|  | 50A| 100mA

100mA

| 1:100| 5Ω| 1%| 1%| 85g

85g

SCT016S| 100A| 1:1000| 5Ω| 0.5%/1%| 1%
SCT016S|  | 120A| 40mA| 1:3000| 10Ω| 0.5%/1%| 1%| 85g
SCT016S|  | 150A| 100mA| 1:1500| 10Ω| 0.5%/1%| 1%| 85g
SCT016S|  | 150A| 50mA| 1:3000| 10Ω| 0.5%/1%| 1%| 85g
SCT016S|  | 160A| 40mA| 1:4000| 10Ω| 0.5%/1%| 1%| 85g
SCT016S|  | 200A| 100mA

50mA

| 1:2000| 10Ω| 0.5%/1%| 1%| 85g

85g

 | 1:4000| 10Ω| 0.5%/1%| 1%
SCT016S| 200A
 |  |  |  |  |  |
Model| Input

current

| Output| Turns ratio| Power| Accuracy| Linearity| Weight|
SCT016S|  | 60A| 1A

1A

| 1:60| 0.1VA| 1%| 1%| 85g

85g

SCT016S| 80A| 1:80| 0.1VA| 1%| 1%
SCT016S| 100A| 1A| 1:100| 0.1VA| 1%| 1%| 85g
 |  |  |  |  |
Model| Input

current

| Output| Turns ratio| Load

resistance

| Accuracy| Linearity| Weight|
SCT016S|  | 50A| 0.333V

0.333V

| –| built-in| 0.5%/1%| 1%| 85g

85g

SCT016S| 100A| –| built-in| 0.5%/1%| 1%
SCT016S| 150A| 0.333V| –| built-in| 0.5%/1%| 1%| 85g

Can be customized parameters/lead length/lead specifications according to user requirements.

Wiring schematic diagram

  • Built-in sampling resistance Voltage output type,
  • Secondary doesn’t allow short circuit

TVS : Transient voltage suppressor Current output type,
Secondary doesn’t allow open circuit

Cable (AWG22)
Specifications of lead wire: 20.3mm black and white twisted pair: (1AOutput: 0.75mm black and white twisted pair)

  • The length of lead wire: 50cm
  • Color of lead wire: white, black

Outline size :  (in: mm)

HYDC-SCT016S-50A-Split-Core-Current-Transformer-FIG-5

www.poweruc.pl

FAQ

  • Can the parameters of the current transformer be customized?
    • Yes, parameters such as lead length and specifications can be customized according to user requirements.
  • What is the maximum continuous input current supported by the SCT016S?
    • The maximum continuous input current supported is 120% of the rated input for optimal performance.

Read User Manual Online (PDF format)