HYDC SCT016S 50A Split Core Current Transformer User Guide
- June 17, 2024
- HYDC
Table of Contents
HYDC SCT016S 50A Split Core Current Transformer
Specifications
- Model: SCT016S
- Input Current: 50A – 200A
- Output: 100mA
- Turns Ratio: 1100 – 14000
- Load Resistance: 5 – 10
- Accuracy: 0.5% – 1%
- Linearity: 1%
- Weight: 85g
OVERVIEW
Ф16mmAperture Split core current transformer
Characteristic
- Safety lock buckle, easy to install
- Built-in over-voltage protection device (TVS tube)
- Lead type output and length can be customized
- Suspended type
Product application
- Portable instrument
- Household metering
- Monitor motor load
Product advantage
- Small volume, lightweight
- Low cost
- High turns, high precision
Installation diagram
Primary threading method(Firing line)
Typical technical index
- Material of core—— Silicon steel sheet
- Working voltage—— Phase voltage≤720V
- Working temperature——- 25℃~+60℃
- Storage temperature——- 30℃~+90℃
- Frequency range—— 50Hz~60Hz
- Dielectric strength—— Input(bare conductor)/output AC 800V/1min 5mA 50Hz Output/Outer shell AC 3.5KV/1min 5mA 50Hz
Electrical parameters:( The following parameters are typical values and actual values will be subject to product testing)
| Max. continuous input current: 120% of rated input|
Model| Input
current
| Output| Turns ratio| Load
resistance
| Accuracy| Linearity| Weight|
SCT016S| | 50A| 100mA
100mA
| 1:100| 5Ω| 1%| 1%| 85g
85g
SCT016S| 100A| 1:1000| 5Ω| 0.5%/1%| 1%
SCT016S| | 120A| 40mA| 1:3000| 10Ω| 0.5%/1%| 1%| 85g
SCT016S| | 150A| 100mA| 1:1500| 10Ω| 0.5%/1%| 1%| 85g
SCT016S| | 150A| 50mA| 1:3000| 10Ω| 0.5%/1%| 1%| 85g
SCT016S| | 160A| 40mA| 1:4000| 10Ω| 0.5%/1%| 1%| 85g
SCT016S| | 200A| 100mA
50mA
| 1:2000| 10Ω| 0.5%/1%| 1%| 85g
85g
| 1:4000| 10Ω| 0.5%/1%| 1%
SCT016S| 200A
| | | | | |
Model| Input
current
| Output| Turns ratio| Power| Accuracy| Linearity| Weight|
SCT016S| | 60A| 1A
1A
| 1:60| 0.1VA| 1%| 1%| 85g
85g
SCT016S| 80A| 1:80| 0.1VA| 1%| 1%
SCT016S| 100A| 1A| 1:100| 0.1VA| 1%| 1%| 85g
| | | | |
Model| Input
current
| Output| Turns ratio| Load
resistance
| Accuracy| Linearity| Weight|
SCT016S| | 50A| 0.333V
0.333V
| –| built-in| 0.5%/1%| 1%| 85g
85g
SCT016S| 100A| –| built-in| 0.5%/1%| 1%
SCT016S| 150A| 0.333V| –| built-in| 0.5%/1%| 1%| 85g
Can be customized parameters/lead length/lead specifications according to user requirements.
Wiring schematic diagram
- Built-in sampling resistance Voltage output type,
- Secondary doesn’t allow short circuit
TVS : Transient voltage suppressor Current output type,
Secondary doesn’t allow open circuit
Cable (AWG22)
Specifications of lead wire: 20.3mm black and white twisted pair:
(1AOutput: 0.75mm black and white twisted pair)
- The length of lead wire: 50cm
- Color of lead wire: white, black
Outline size : (in: mm)
FAQ
- Can the parameters of the current transformer be customized?
- Yes, parameters such as lead length and specifications can be customized according to user requirements.
- What is the maximum continuous input current supported by the SCT016S?
- The maximum continuous input current supported is 120% of the rated input for optimal performance.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>