LAARS A0078800 Tanks For Volume Water Heater User Manual
- June 4, 2024
- LAARS
Table of Contents
LAARS A0078800 Tanks For Volume Water Heater
Specially designed for installations where the peak demands require stored water. Both dependable and versatile, the storage tank is perfect for simple installations or for needed replacements. The tank can become a storage system by simply manifolding several tanks together when larger quantities of stored water are necessary. The Commercial Storage Tank meets the stringent efficiency performance criteria for energy-consuming appliances set forth in ASHRAE 90.1b (current standard).
Features
Check these quality features:
-
2” Non-CFC Foam Insulation:
The insulation covers the sides and top of the tank, reducing the amount of heat loss. This results in less energy consumption, improved operation efficiencies and jacket rigidity. -
Steel Tank:
Heavy gauge steel is automatically formed, rolled, and welded. -
Glass-Lined Tanks:
An exclusively engineered enamel formula that provides superior tank protection from the highly corrosive effects of hot water. This formula is fused to the steel surface by firing at a temperature of over 1600°F (871°C). -
T & P Valve Openings:
A separate 1″ NPT opening is provided for the installation of a temperature and pressure relief valve. -
Pressure Rating:
150psi (1034kPa) working pressure rating (certified at 300psi (2068kPa) test pressure). -
ASME Construction:
Models A0070101, A0073101 and A2086000 come standard with ASME construction. -
Two Protective Magnesium Anode Rods:
Provide added protection against corrosion for long trouble-free service. -
Rear Water Connection:
119-gallon models (A0078800 and A0070101) have a 2” NPT rear water connection for cold water make-up to the tank. -
Dielectric Fittings:
Factory-installed true dielectric fittings extend water heater life and ease installation. -
Handhole Cleanout:
Provides easy access for periodic inspection of the interior of the tank. -
High Temperature:
Designed for storage of potable water up to 180°F (82°C). -
¾” NPT Aquastat Fitting
Brass Drain Valve
APPLICATION NOTE: Local code or system design may require that a pressure and temperature relief valve be installed on the tank. When required, such devices should be sized to the output capacity of the boiler(s) heating the tank using the steam pressure rating of the relief valve.
Jacketed Small Volume Models
Model Number| Capacity
U.S. Imp. Gal. Gal.
| A
Floor-to-Heater Top
in.
| B
Jacket Dia.
in.
| C
Floor to T &P Conn.
in.
| D
Floor to Hot Water Conn.
in.
| E
Floor to Aquastat & Top Circ. Conn.
in.
| F
Floor to Bottom Circ. Conn. in.
| G
Floor to Drain
in.
| H
Floor to Hand Hole Cleanout
in.
| J
Floor to Rear Water Conn.
in.
| Water Conn. Size.†
in.
| Approx. Shipping Weight
lbs.
---|---|---|---|---|---|---|---|---|---|---|---|---
A0073100| 80 67| 583/4| 24| 521/2| 593/4| 141/4| 91/4| 43/4| 71/4| —|
2(F&T)| 192
A0073101| 80 67| 583/4| 24| 521/2| 593/4| 141/4| 91/4| 43/4| 71/4| —|
2(F&T)| 278
A0078800| 119 100| 621/2| 28| 553/4| 631/2| 141/2| 91/2| 5| —| 91/2|
2(F&T), 2(R)| 312
A0070101| 119 100| 621/2| 28| 553/4| 631/2| 141/2| 91/2| 5| 71/2| 91/2|
21/2(F&T), 2(R)| 366
A2086000*| 200 167| 77| 32| 66| 78| 161/4| 111/4| 63/4| 91/4| —|
21/2(F&T)| 633
Model Number| Capacity
Liters
| A
Floor-to-Heater Top
mm.
| B
Jacket Dia.
mm.
| C
Floor to T &P Conn.
mm.
| D
Floor to Hot Water Conn.
mm.
| E
Floor to Aquastat & Top Circ. Conn. mm.
| F
Floor to Bottom Circ. Conn. mm.
| G
Floor to Drain
mm.
| H
Floor to Hand Hole Cleanout
mm.
| J
Floor to Rear Water Conn.
mm.
| Water Conn. Size.†
mm.
| Approx. Shipping Weight
kg.
---|---|---|---|---|---|---|---|---|---|---|---|---
A0073100| 303| 1492| 610| 1334| 1518| 362| 235| 121| 184| —| 51(F&T)| 87
A0073101| 303| 1492| 610| 1334| 1518| 362| 235| 121| 184| —| 51(F&T)| 126
A0078800| 450| 1588| 711| 1416| 1613| 368| 241| 127| —| 241| 51(F&T), 51(R)|
142
A0070101| 450| 1588| 711| 1416| 1613| 368| 241| 127| 191| 241| 64(F&T),
51(R)| 166
A2086000*| 751| 1956| 813| 1676| 1981| 413| 286| 171| 235| —| 64(F&T)| 287
- Meets American Society of Mechanical Engineers (ASME) Code.
† F=Front Water Connections. R= Rear Water Connections.
General
Water connections 2″ (51mm) NPT (except where noted). T&P tapping 1″ (25mm)
NPT. Aquastat tapping 3⁄4″ (19mm) NPT.
All models are certified at 300 psi test pressure (2068 kPa) and 150 psi
working pressure (1034 kPa).
Dimensions and specifications are subject to change without notice in accordance with our policy of continuous product improvement.
Customer Service and Product Support: 800.900.9276
- Fax 800.559.1583
- Headquarters: 20 Industrial Way, Rochester, NH, USA 03867
- 603.335.6300
- Fax 603.335.3355
9 Brigden Gate, Halton Hills, Ontario, Canada L7G 0A3 905-203-0600 Fax: 905-636-0666
www.Laars.com
References