KENTON SYNC-5 1 into 5 Active DIN Sync Splitter Box User Manual
- June 17, 2024
- KENTON
Table of Contents
KENTON SYNC-5 1 into 5 Active DIN Sync Splitter Box
FCC Statement for SYNC-5
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, under Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used by the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Information on Disposal for Users of WEEE
This symbol on the product and/or accompanying documents means that used
electrical and electronic equipment (WEEE) should not be mixed with general
household waste. For proper treatment, recovery and recycling, please take
this product(s) to designated collection points where it will be accepted free
of charge. Alternatively, in some countries, you may be able to return your
products to your local retailer upon purchase of an equivalent new product.
Disposing of this product correctly will help save valuable resources and
prevent any potential negative effects on human health and the environment,
which could otherwise arise from inappropriate waste handling. Please contact
your local authority for further details of your nearest designated collection
point. Penalties may be applicable for incorrect disposal of this waste, by
your national legislation.
For disposal in countries outside of the European Union
This symbol is only valid in the European Union (EU). If you wish to discard
this product, please contact your local authorities or dealer and ask for the
correct method of disposal.
Description
The SYNC-5 has one DIN Sync Input and five DIN Sync output ports to enable you to connect several DIN Sync devices to one DIN Sync controlling device, without the usual problems encountered when daisy-chaining devices. The SYNC-5 outputs are all short circuit proof and each output can drive at least 2 sync inputs if required (however you’ll need a splitter cable). The SYNC-5s active circuitry also restores the quality of signals received at the DIN Sync Input for optimum performance. The SYNC-5 is powered by a mains adaptor (supplied), so it doesn’t need periodic battery changes to keep it working, enabling you to “fit and forget”.
Connecting
Ensure that the power adaptor is plugged in, and the ACTIVE LED on the SYNC-5 is on. Connect the DIN Sync output of your sequencer or drum machine to the DIN Sync the Input of the SYNC-5 and connect one or more of the DIN Sync Out ports of the SYNC-5 to the DIN Sync inputs of the devices you want to synchronise.
Operation
The ‘active’ LED will be lit when the unit is powered on. When sync is applied, the LED will flash with the sync pulses at low tempos, however at higher tempos, the flash will become too fast to see and the LED will just appear to be on, but at a slightly lower brightness. If a ‘start’ signal is present but no sync, the LED will go out. Although intended primarily for use with Roland equipment (24 clocks per quarter note), the SYNC-5 can also be used with Korg equipment (48 clocks per quarter note) although it cannot convert between the two. The DIN Sync outputs of the SYNC-5 give approximately +5 volts when high which is enough to drive all DIN Sync Inputs. The DIN Sync Input of the SYNC-5 will accept any voltage up to +15 volts so can be connected to the output of any DIN Sync equipment without any problem. All 4 signal pins are connected between input and output although in most applications only Stop/Start (pin1) and Clock (pin3) are used. The ground connection (pin 2) is always used.
For your reference, DIN Sync connectors are wired as follows:
Pin
- 1 – Stop / Start
- 3 – Clock
- 4 – Reset & Start (may differ on some devices)
- 5 – Fill In (may differ on some devices)
- 2 – Ground
If looking at the solder terminals of a DIN plug with the pins arranged in a semicircle at the bottom (like a smile) then the PINs going left to right are 3,5,2,4,1.
Specification
- Power 9V DC @ 10mA (regulated or unregulated) – never apply more than 12V (never use an unregulated supply greater than 9V as unregulated supplies typically give a higher output than shown)
- Power Input 2.1mm plug (centre positive)
- Sync In / Out 1 x 5 pin DIN input, 5 x 5 pin DIN outputs
- Weight 110g (excluding power supply)
- Dimensions 100 x 46 x 32 mm
- Power supply An energy-efficient switch-mode PSU is supplied with the unit.
- The unit will be shipped with a power supply appropriate to the destination country. UK, EU, US & Australian types are available.
Warranty
The SYNC-5 comes with a 12-month (from purchase date) back-to-base warranty,
(i.e. customer must arrange and pay for carriage to and from Kenton
Electronics Ltd).
Unit 3, Epsom Downs Metro Centre, Waterfield, Tadworth, KT20 5LR, UK
+44 (0)20 8544 9200 www.kenton.co.uk
tech@kenton.co.uk
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>