Thank you for purchasing the Alinco switching mode DC-regulated power supply, DM-330MV. The DM-330MV instruction manual contains important safety and operating instructions. Read this manual carefully before using this product. Keep the manual for future reference.

INTRODUCTION

Alinco’s DM-330MV is a high-efficiency, compact, lightweight, high-performance switching mode power supply. It is also engineered to minimize the switching noise specifically for communication use. Even when noise occurs, it may be eliminated with the Noise-Offset function. Also convenient functions like pre- set voltage. remote control and a highly visible backlit meter are standard in this power supply.

CAUTION

  1. Even though the chassis of the unit is negatively grounded, use the correct term- minerals to connect the cable.
  2. When plugging the unit into a wall, it must be turned off.
  3. Place the unit in a dry and well-ventilated area.
  4. Never touch the unit while in use. Even though it is designed for high efficiency, the unit will still get hot.
  5. If the unit reaches- es a certain temperature, the “extreme temperature protection” function will protect the unit by automatically dropping– ping the current down to a safe level and the protection indicator will light up.
  6. A current limiting system will protect the unit from overloading. If a short circuit occurs at the output, the unit is protected by a short-circuit protection function.
  7. Immediately turn off the unit and repair the cause of the short circuit, then turn it back on.
  8. Do not use the unit for devices that require high current input at the start, such as motorized equipment. Do not use the unit to charge a car battery.
  9. Do not use a car cigarette lighter in the cigarette plug socket on the unit.
  10. Before replacing a fuse make sure the unit is turned off. Be sure to use the specified type of fuse.
  11. Make sure the product is always suitably grounded to prevent electric shock and to reduce noise. (The unit can be grounded by connecting a grounding cable to the appropriate screw).
  12. Never disassemble, modify, ör touch the inside of the unit unnecessarily.
  13. This could cause damage to the product and will void the warranty.

PRESET FUNCTION

When this function is activated, a preset voltage will be supplied regardless of the current voltage setting. To store the preset voltage, turn the switch to the preset position and adjust the preset voltage to the desired output level. When this function is selected the vol- The stage adjustment control on the front panel will be deactivated to protect from overvoltage.

SPECIFICATIONS

  • Input voltage: 120VAC (MVT) /230VAC (MVZ)
  • Output voltage: 5~15VDC variable
  • Output voltage regulation: less than 2%
  • Protection: short-circuit, Automatic current limiting over 32A over-temperature
  • Output current: 32A (max), 30A (continuous)
  • Ripple: less than 15mVp-p at rated load
  • Fuse: 8A (MVT)/ 4A(MVZ)
  • Meter: single volt / current meter, back-lit
  • Dimensions: 175(W) X67(H) X 165 (D)mm
  • Weight: approx. 2kg

REMOTE CONTROLLER
The DM-330MV does not include a remote controller. Nor is it available as an optional accessory. It can be easily assembled using the diagram provided. The adjustable voltage ranges from approximately 5~15 volts.

CAUTION
The remote controller must be assembled exactly as the diagram shows. Using SP resistors of different values can damage the unit and will void the warranty. When the remote controller is connected, the unit must be turned off. The maximum length of cable. that should be used is 1.5m or 5ft.

PART NAMES AND FUNCTIONS

Alinco-DM-33OMV-Switching-Mode-DC-Regulated-Power-Supply-
fig-2

  • Power switch: Tums the unit on and off.

  • Meter switch: Select the position to indicate voltage (V) or current (A).

  • Meter. Displays the voltage or current.

  • Snap-in output terminal: 5A max. Red positive, black negative.

  • Cigarette plug terminal: 10A max.

  • Preset indicator: Lights up when the preset function is activated.

  • Protection indicator, Lights up as a warning when the current limiting system is activated.

  • Power indicator. Lights up when the unit is turned on.

  • Voltage adjustment: Adjusts voltage between 5.0 and 15.0 volts. Tum clockwise to increase and counterclockwise to decrease the voltage. When it is set at the center position it will supply 13.8 volts.

  • Noise off-set volume control: Adjust to eliminate the pulse noise of the switching circuit. This patent pending function is specially designed for communication use. (its effectiveness may vary depending on the frequency and mode.)

  • Cooling fan: The fan turns on and off automatically.

  • Remote control terminal: By connecting a remote controller, the output voltage can be remotely controlled.
    Note : When the remote control is connected to the unit, the unit must be turned off. When the remote control is being used the voltage adjustment knob and preset function will be deactivated.

  • Preset switch: To store the preset voltage, turn this switch to the preset position and adjust the preset volume to the desired output level.

  • Heat sink: Do not touch the surface when the unit is in use. Let the unit cool down completely before touching it.

  • Grounding screw: Used to connect the Earth grounding cable to the unit.

  • Output terminal: 32A max. Red positive, black negative.

  • Power cable: 120VAC outlet (MVT)/ 230VAC outlet (MVZ)

  • Fuse: 8A(MVT)/ 4A(MVZ)

FOR YOUR SAFETY
The following pages explain how to avoid possible accidents and damage to the user and his property. They will explain the proper manner in which to use this product.

Explanation of caution indications

Alinco-DM-33OMV-Switching-Mode-DC-Regulated-Power-Supply-
fig-3

  1.  injuries, skin bums, electric shocks, etc, not requiring hospitalization or extensive medical treatment.
  2. excels and perage to buildings and possessions; injury to domesticated

Explanation of sumbols

Alinco-DM-33OMV-Switching-Mode-DC-Regulated-Power-Supply-
fig-4

Before using this product, please note that we shall not assume any responsibility whatsoever for purely economic losses, such as lost communication opportunities, resulting from breakdowns, incorrect operation, product problems, or external causes- es such as power cuts.

Warning
This unit should only be used with a standard wall outlet 120VAC(MVT)/230VAC(MVZ). If it is used in any other manner electric shock and fire could occur.

Compulsory
Never touch the chassis of the unit during use. The sur- the face of the product may become very hot, especially the heat sink. A burn to the skin may occur.

Prohibited
Wash immediately with water if any liquid leaks from inside the unit and comes in contact with skin and or clothes. It may initiate the skin and could stain clothing. If any liquid gets into the eye, wash it immediately and contact a doctor. It may cause injury to the eye. Do not short-circuit the cables. Make sure the cables are connected to the correct terminal. (Positive to positive and negative is negative)

Danger

  • Do not disassemble, modify or repair the unit unless otherwise specified in the manual. Only an authorized technician may do this. Nev-modify the cable to extend or shorten it.
  • This may cause fire and or electric shock and will void the warranty.
  • Always hold the plug when plugging and unplugging the unit. Never unplug the unit by pulling the cable. It may cause fire, shock and damage- age to the unit.
  • Do not plug/unplug the unit with wet hands. It may easily- ly cause electric shock.
  • Do not use the unit where there may be flammable gas. This may cause fire and explosion.
  • Unplug the cable when replacing the fuse. Use the specified fuse only. Using the wrong fuse could cause heat and fire.
  • Never use the unit outside, in a bathroom, or any other place where the unit could become wet. Do not rest any- the thing that contains liquid on the product.
  • If liquid gets inside the unit, it could cause fire, shock and damage to the unit. If this happens, unplug the unit immediately. Do not use the unit in a humid environment.
  • If dew condenses on the unit, dry it completely before use.
  • Unplug the unit during maintenance. Otherwise, it may cause shock and damage to the product.
  • Unplug immediately if anything noticeably unusual happens, such as smoke and or strange odours coming from the unit. Contact our authorized service centres immediately for service.

Caution

  • Use this unit only at room temperature. (10 to 35 degrees cen- grade or 50 to 95 degrees Fah- Fahrenheit) Keep the unit in a dry and well-ventilated place.
  • Do not use the unit in direct sunlight, where it may come in contact with water or a poorly ventilated area. It may cause heat, fire and damage to the unit.
  • Never leave the unit within a child’s reach. This may injure them or bum their skin.
  • Make sure that the devices that are to be connected meet the specifications of this unit, otherwise, it may cause damage to
  • the product. Never insert any metal or flammable objects inside the unit.
  • It may cause damage, shock and fire.
  • If any foreign objects get into the unit, turn it off unplug it and contact an authorized service centre.
  • Place the unit on a secure and horizontal surface.
  • If it is placed on an unstable surface, the unit may drop and cause damage and injury. This will also help get accurate meter readings.
  • Do not cover the air vent on the chassis or the fan. This may cause extreme heat, fire and damage.
  • Do not use the unit for devir.- es that require high current input at the start, such as motorized equipment. Do not use the unit to charge the car battery.
  • This may cause damage to the unit.
  • Never try to use a car cigarette lighter in the cigarette lighter socket of this product. Otherwise, the product may become damaged.
  • Insert the cigarette plug securely and completely into the socket.
  • Insufficient connection may cause.

Head Office: “TWIN 21” MID Tower Building 25F
1-61, 2-Chome, Shiromi, Chuo-ku, Osaka 540-8580, Japan
Phone: 06-6946-8150 Fax: 06-6946-8175
E-mail: [email protected]

U.S.A.
Phone: 300-6 18-8616 F17: 3 To-648-8754 90501-6201, U.S.A. http://www.alinco.com/

Germany
Eschbomer Landstrasse 55,60489 Frankfurt am Main, Germany
Phone: 089-786018 Fax: 089-789-60788 http://www.alinco.de/
01999 Alinco, Inc., Osaka, Japan. All rights reserved.

Although Ainco has designed this manual to be as comprehensive and accurate as possible, we reserve the right to make changes at any time to the contents or our specications. Please note that certain products and accessories may not be
available in all countries of distribution. Please consult your Authorized Alinco Dealer for information.

References

Read User Manual Online (PDF format)