LATT CD-5048 Automatic Hand Soap Dispenser Wall Mount Touchless Hand Washer User Manual

June 17, 2024
LATT

CD-5048 Automatic Hand Soap Dispenser Wall Mount Touchless Hand Washer
User Manual

 features

please read user manual carefully before using

AS automatic soap dispenser, this item is adapting high-end electronic controlled infrared sensor technology and energy-saving devices with advantage of safety and stable. It enables people to prevent cross-infection from hand touching Avoid contact with the hand, prevent cross infectiono

  1. Materials as well as the whole manufacturing process meet the international standards. It is environmental without any harmful constituents.
  2. lt’s more confidence with lock design for public places using. Meanwhile.cap can isolate the air and water which protects iquid to be damaged.
  3. Product consists of separate parts which is very easy to be installed and convenient for after-sales.
  4.  This item supports 3 kinds fluid production adjustment which is easy to operate.
  5. Product enjoys the advantages of Long standby with energy – saving design (After 3 seconds it will automatically enter sleep mode) and low power alarm buzzer.

 Specification

Item NO Automatic Soap Dispenser CD-5048
Size L85XW87XH207mm
Capacity 400m1
Fluid production (adjustable) 1.1.3g (one time) 2.1.69 (one time) 3.2.0g (

one time)
Working principle| Infraredsensor
Sensing distance| 0.5-10 cm
Voltage| DC6V(1.5 x 4pcs)
Power| 2.4W
Battery type| Size AA 1.5 V
Battery life| More than 30.000 times
Low battery alarm| Once the product is less than the operating voltage of 4.4v, the the alarm will ring.
Memory retention time| About 2 minutes after shutdown
Waterproof Rate| IPX5

Precautions

  1. This product is suitable for indoor use. Please keep space more than 40cm below the product when you install.
  2. Choose an appropriate location to install the soap dispenser. Do not put it in the strong reflective surface such as mirror, or humid environment.
  3. If the liquid is left about 1 cm, please join the liquid. Product sensor effective range is about 1 Ocm.If product beeps when there s no obstacle in the sensing area within 14cm, please replace the battery.
  4.  Do not use soap under the strong light, because the strong light will damage the nfrared sensor.
  5. To prevent any object blocking the liquid outlet, please keep the soap clean and make sure no bulk impurities.
  6.  Please do not keep the product off work in a long time, liquid may be solidified.
  7.  Cleaning:
    A: When not use the product, please take out the liquid and battery, clean inside with a rag.
    B: Please don’t flush the product appearance directly, it will damage the circuit board.
    C: Please clean the product’s surface with a damp cloth and dry towel, clean the battery can only with a dry towel.
    D: To avoid damage to the surface.please do not use corrosive chemical solvents to clean the product (Low concentration alcohol or medical alcohol can be used .

Installation Instructions

  1. As shown n Fig A, rotate the battery cover in counterclockwise direction align the dot on the panel to open and take out the battery box, then place four batteries, close cover, press the power button. Power indicator flashing with blue light three times which shows power turning on, which default is the first gear in sleep mode.
  2. As shown n Fig B, using key to open the soap dispenser cover in counterclockwise direction, then pushed outwardly the back of the bottle and taking out by slide it down.
  3. As shown n Fig C, marking on the wall with the help of black plane prepares for drilling holes
  4. As shown n Fig D, using impact drill make a hole on the mark and nsert the piston we offered, and then use the screws to fix the back plane (as shown in Fig E).
  5. As shown n Fig F, fill the bottle and then swirl key counterclockwise to close the cap (as shown in Fig G).
  6. As shown n Fig H, test within the effective range of 0.5cm to 1 Ocm.

Function Settings

  1. Pressing the power button, then the power indicator flashing with blue light three times which shows power turning on, which default is the first gear in sleep mode.
  2. When put your hand n the effective sensor range of 0.5cm to 1 Ocm, the machine will flash with blue light and start work with fluid production of 1.3g.
  3. The setting way of second gear:
    a. Pressing” ” the fist time, the machine will enter into the second gear with the fluid production of 1.6g.
    b. Pressing” ” the second time, the machine will enter into the third gear with the fluid production of 2.0g.
    c. Pressing” the third time, the machine will back into the first gear.

Tips

  1. The first time to turn on the machine, t will take about 1.5 second to enter operating mode.

  2. After adding liquid into the bottle, it needs to be sensed a few times to drain air inside.

  3. If the machine does not work:
    a.Close your hand to the detector.
    b.Check the batteries
    c.Check the power
    d.Check the machine below, if there are obstacle, especially strong light, please remove the machine or install in a higher place.

  4. lfthere is no liquid come out:
    a.For the first time, because liquid is not in the pump, please try more few times.
    b.The liquid may caking and blocking the outlet in winter, in this case, you can put some hot water about 60°C into the liquid.
    c. The liquid is nearly running out.