electriQ ECOSILENT8 Portable Air Conditioner User Manual

June 17, 2024
ElectriQ

electriQ ECOSILENT8 Portable Air Conditioner

electriQ-ECOSILENT8-Portable-Air-Conditioner-product

Product Information

  • Specifications
    • Model: Electric Portable Air Conditioner
    • Models: ECOSILENT8, ECOSILENT8E (8,000 BTU), ECOSILENT10, ECOSILENT10E (10,000 BTU)
  • Features and Parts List
    • The electric Portable Air Conditioner comes with the following features and parts:
  • Control Panel
    • Louvers
    • Front Cover
    • Top Cover Rear Housing
    • Castors
    • Upper-Air Inlet
    • Exhaust Outlet
    • Lower Air Inlet
    • Power Cable
    • Carry Handle
    • Exhaust Hose
    • Window Slide Bar
  • Safety Instructions
    • Please follow these safety instructions before using the portable air conditioner:
    • Read the user manual before using the product.
    • Keep the unit upright for at least 3-4 hours before use.
    • Ensure that there are no obstructions to the air inlets and outlet grills.
    • Keep the outlet vent well-ventilated and not obstructed.
  • Installation
    • To install the portable air conditioner, follow these steps:
    • Attach the fishtail connector to the end of the hose by extending the end and twisting until firmly attached (at least 3 full rotations).
    • Attach the connector on the opposite end of the pipe to the exhaust outlet on the rear of the appliance by putting it into position and twisting it to lock it in place.
    • Ensure that the unit is upright and there are no obstructions to the air inlets and outlet grills.
  • Installation of Window Kit
    • The window kit (slide bar and fishtail) can be used with sliding windows and doors. For other types of windows, the fishtail should be used on its own. Follow these steps:
    • Partially open the window and place the extended slide bar in position before closing the window onto it.
    • Fix the fishtail adaptor into the opening on the slide bar.
    • Fix the exhaust connector on the opposite end of the exhaust hose to the exhaust outlet on the rear of the air conditioner.
  • Operation
    • To operate the portable air conditioner, use the control panel and remote control:
    • Press the POWER button to turn the unit ON or OFF.
    • Press the SPEED button repeatedly to cycle through the five fan speeds (F1 to F5).
    • Use the MODE button to select different modes (Cool, Dry, Fan).
    • Use the SLEEP button to activate sleep mode.
    • Use the TIMER button to set a timer for automatic shutdown.
  • Cleaning and Maintenance
    • Regular cleaning and maintenance is important for optimal performance. Follow these steps:
    • Ensure the unit is turned off and unplugged before cleaning.
    • Remove the front cover and clean it with a soft cloth and mild detergent.
    • Clean the louvers, air inlets, and outlet grills using a soft brush or vacuum cleaner.
    • Empty the internal water tank regularly.
  • Troubleshooting
    • If you encounter any issues with the portable air conditioner, refer to the troubleshooting section in the user manual or contact our support team.
  • Error Codes
    • If you see any error codes on the display, refer to the user manual for detailed information on each code.
  • Support
    • If you need further assistance or have any questions, please contact our support team. Visit our website www.electriQ.co.uk. for more information.

FAQs

  • Q: Can the portable air conditioner be used in multiple rooms?
    • A: Yes, the unit can easily be moved from one room to another. Just ensure it is kept upright during transportation.
  • Q: How do I install the window kit for non-sliding windows?
    • A: For other types of windows, use the fishtail adaptor on its own and follow the installation steps provided in the user manual.
  • Q: How often should I empty the internal water tank?
    • A: The internal water tank should be regularly emptied to prevent overflowing. Monitor it and empty it as needed. Permanent plumbing or an external water pump can also be used for uninterrupted use.
  • Q: What should I do if the unit overheats?
    • A: Ensure that the outlet vent is well-ventilated and not obstructed. Keep the air hose as straight and short as possible to avoid reducing the performance of the unit.

SAFETY INSTRUCTIONS

Important!

  • Carefully read the instructions before operating the unit
  • This appliance is for indoor use only.
  • Rating: This unit must be only connected to a 220-240 V / 50 Hz earthed outlet.
  • Installation must be by the regulations of the country where the unit is used.
  • If you are in any doubt about the suitability of your electrical supply have it checked and, if necessary, modified by a qualified electrician.
  • This air conditioner has been tested and is safe to use. However, as with any electrical appliance – use it with care.
  • Disconnect the power from the appliance before dismantling, assembling, or cleaning.
  • Avoid touching any moving parts of the appliance.
  • Never insert fingers, pencils, or any other objects through the guard
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities.
  • It is also not intended for use by those with a lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
  • Do not leave children unsupervised with this appliance.
  • Do not clean the unit by spraying it or immersing it in water.
  • Never connect the unit to an electrical outlet using an extension cord. If an outlet is not available, one should be installed by a qualified electrician.
  • Never operate this appliance if the cord or plug is damaged. Ensure the power cord is not stretched or exposed to sharp objects/edges.
  • A damaged supply cord should be replaced by the manufacturer or a qualified electrician to avoid a hazard.
  • Any service other than regular cleaning or filter replacement should be performed by an authorized service representative. Failure to comply could result in a voided warranty.
  • Do not use the appliance for any purpose other than its intended use.
  • The air conditioner unit must always be stored and transported upright, otherwise irreparable damage may be caused to the compressor; if in doubt we suggest waiting at least 24 hours before starting the unit.
  • Avoid restarting the air conditioning unit unless 3 minutes have passed since being turned off. This prevents damage to the compressor.
  • Never use the mains plug as a switch to start and turn off the air conditioning unit. Use the provided ON/OFF button located on the control panel.
  • Always place the unit on a dry and stable surface.
  • The appliance should not be installed in the laundry or wet rooms.
  • The appliance must be placed in a room without sources of ignition (for example: open flames, an operating gas appliance or an operating electric heater).
  • R290 refrigerant gas complies with European environmental directives.
  • R290 has a low GWP (Global Warming Potential) of 3.
  • The ECOSILENT8 / 8E contains about 220 g of R290 refrigerant gas.
  • The ECOSILENT10 / 10E contains about 280 g of R290 refrigerant gas.
  • Do not use or store in an unventilated space with an area smaller than 10.6 m2 per unit (ECOSILENT8 / 8E) or 13.4 m2 per unit (ECOSILENT10 / 10E).
  • The room must be such as to prevent stagnation of possible leaks of refrigerant gas as there could be a danger of fire or explosion should the refrigerant come into contact with electric heaters, stoves or other sources of ignition.
  • Refrigerant gas may be odorless.
  • Do not use the product and contact the retailer for advice, if damage has occurred to the unit which may have compromised the refrigerant system.
  • Any repairs or maintenance must only be carried out on the unit by a suitably qualified engineer. Before opening and servicing the unit the authorized engineer must have a copy of the manufacturer’s service manual and must follow the safety information contained within it to ensure all hazards are minimized.
  • The refrigerant system should not be perforated or punctured. Energy Saving and Unit Safety Protection Tips
  • Do not cover or restrict the airflow from the outlet or inlet grills.
  • For maximum performance, the minimum distance from a wall or object should be 50cm.
  • Keep the filters clean. Under normal conditions, filters should only need cleaning once every three weeks (approximately). Since the filters remove airborne particles, more frequent cleaning may be necessary, depending on the air quality.
  • For the initial start-up set the fan speed to maximum and the thermostat to 5 degrees lower than the current room temperature. After, set the appliance to your desired settings.
  • To protect the unit, we recommend not using the cooling function when the ambient temperature is higher than 35oC.

FEATURES AND PARTS LIST FEATURES

  • 3 in 1 Cooling, Fan, and Dehumidifier are great for Rooms up to 20 sqm.
  • 5-speed DC fan: balancing quiet operation with performance.
  • Smartwool Logic for Improved Energy Efficiency.
  • 24 Hours Start / Stop Timer
  • Digital Thermostat.
  • Remote Control.
  • Castors and Handles for Enhanced Portability.
  • Auto-Restart to retain the settings in the event of power failure.

electriQ-ECOSILENT8-Portable-Air-Conditioner-fig-1
\(1\)

INSTALLATION

WARNING:

  • Before using this unit, please keep it upright for at least 3-4 hours.
  • This unit can easily be moved from one room to another.
  • While moving the unit please note that it must always be kept upright and then placed on an even surface.
  1. Attach the fishtail connector to the end of the hose, by extending the end and twisting until firmly attached (At least 3 full rotations).
  2. Attach the connector on the opposite end of the pipe to the exhaust outlet on the rear of the appliance by putting into position and twisting to lock in place.
  3. Make sure the unit is upright and there are no obstructions to the air inlets and outlet grills.

INSTALLATION OF WINDOW KIT

The window kit (slide bar and fishtail) can be used with sliding windows and doors. For other types of window, the fishtail should be used on its own.

  1. Partially open the window and place the extended slide bar in position before closing the window onto it.
  2. Fix the fishtail adaptor into the opening on the slide bar
  3. Fix the exhaust connector on the opposite end of the exhaust hose to the exhaust outlet on the rear of the air conditioner.

NOTES:

  • The window kit is only designed to be installed with sliding or sash windows or doors. The window kit is not designed to be used with any other style of windows.
  • The fish tail adaptor can be used without the slide bar with most windows/doors.
  • When using the air conditioner ensure that the opening around the fishtail adaptor is as small as possible to ensure the efficiency of the unit is not reduced.
  • The best form of installation is through a wall duct. By properly venting you expel hot air from your room while efficiently cooling it.
  • Your air conditioner should be used without the vent pipe in dry mode.
  • When using dry mode ensure that an external water tank is used, monitored, and regularly emptied before overflowing.
  • Permanent plumbing can be also installed or an external uplift water pump can be set up to allow for uninterrupted use.

IMPORTANT SAFEGUARDS

  • The length of the soft hose extends from approximately 30 cm to 180 cm.
  • If the hose is extended above this length, the unit may malfunction which can invalidate the warranty.
  • The outlet vent must be well ventilated and not obstructed as this will cause the unit to overheat.
  • Keep the hose as straight and short as possible and avoid bending the air hose by more than 30 degrees in order not to reduce the performance of the unit.

OPERATION

electriQ-ECOSILENT8-Portable-Air-Conditioner-fig-1
\(8\) electriQ-ECOSILENT8-Portable-Air-
Conditioner-fig-1 \(9\)

REMOTE CONTROL

POWER Press to turn the unit on or off.
TIMER Press to set the timer.
DOWN Press to decrease the desired temperature or timer duration.
UP Press to increase the desired temperature or timer duration.
SLEEP Press the sleep button to enter sleep mode.
FAN Press to enter fan/air purifying mode.
COOL Press to enter cool mode.
DRY Press to enter dry (dehumidify) mode.
HIGH Press to enter high (F5) speed fan.
LOW Press to enter low (F1) speed fan.

NOTE: The design of the remote may vary from the diagram, due to continuous product improvement.

MULTI PROTECTIVE FUNCTIONS

  • FROST PROTECTION
    • In COOL, DRY, or SMART COOL modes, if the temperature of the exhaust is too low, the machine will automatically stop operating until the temperature has risen.
  • OVERFLOW PROTECTION
    • When the water in the internal water tank exceeds the warning level, the machine will stop operating and sound an alarm with the LCD display showing “E7”.
    • To resume operation empty the internal water tank. After the water is emptied, the machine will automatically return to its original state.
  • AUTO-DEFROST
    • The machine has an automatic defrosting function.
    • If during operation the temperature of the internal coils drops too low, the unit will enter auto defrost and the heating symbol will flash on the control panel.
  • AUTOMATIC THERMAL PROTECTION
    • To protect the service life of the machine, the machine has automatic thermal protection.
    • If the temperature within the unit is outside of the specified range, the compressor and the lower motor will stop operation.
    • The appliance will automatically return to normal operation after the temperature of the machine recovers.
  • COMPRESSOR PROTECTION
    • To prevent damage to the compressor there is a 3-minute delay start protection function.

MAINTENANCE AND CLEANING

  • PLEASE SHUT OFF THE UNIT AND UNPLUG FROM THE MAINS BEFORE CLEANING OR PERFORMING ANY MAINTENANCE

CLEAN THE SURFACE

  • Clean the surface of the machine with a wet soft cloth. Do not use chemicals, such as benzene, alcohol, gasoline, etc; otherwise, this may cause damage to the surface and or the internal workings of the machine

AIR FILTER CLEANING

  • If the filter screen is clogged with dust, the effectiveness of the air conditioner is reduced.
  • The filter screen should be cleaned once every two weeks or as often as necessary in your environment.electriQ-ECOSILENT8-Portable-Air-Conditioner-fig-1 \(11\)

CLEAN THE UPPER FILTER SCREEN FRAME

  • Grip the edge of the evaporator filter screen frame with both hands. Pull out to remove the filter screen from its frame.
  • If present, unscrew the screws fixing the filter before removing it (as shown in the above figure).
  • Put the evaporator filter screen into warm water with neutral detergent (about 40oC /104oF) and dry it in the shade after rinsing clean.

CLEAN THE LOWER FILTER SCREEN FRAME

  • Hold the handle of the air inlet filter screen frame, and pull it outward gently to remove it.
  • Put the filter screen into warm water with neutral detergent (about 40oC / 104 oF) and dry it in the shade after rinsing clean.

EMPTYING THE INTERNAL WATER TANK

MANUAL DRAINAGE:

  • When the internal water tank is full the unit will stop working, and the unit will display E7.
  • Turn off the unit and unplug. Try not to move the model abruptly as this may cause the water in the internal tank to spill out.
  • Place a tray under the lower water plug or place the unit in a drainage area.
  • Unscrew the drain plug cap and remove the rubber stopper – water will drain from the internal tank. Put the rubber stopper back and screw the drain plug cap back into place.

CONTINUOUS DRAINAGE:

  • Unscrew the drain plug cap and remove the rubber stopper.
  • Connect a water pipe to the upper water outlet.
  • You can plumb this pipe into your current plumbing system, lead it outside, and use gravity fall or a water pump.

NOTE: This model has a self-evaporative function, which reduces the need to empty the water tank in cooling mode. If the unit is vented correctly most of the water is reused to cool the condenser coils and any excess is evaporated. Please do not use continuous drainage if you intend to use the self-evaporating facility.

END-OF-SEASON MAINTENANCE

  1. Remove the rubber stopper from the drainage hole and empty the internal tank. You can also drain the water by leaning the unit backward.
  2. Run the unit in fan mode, with a low fan speed, with the rubber stopper still removed, and a container under the drain port.
  3. Keep the unit in this mode for half a day – until the conduit is dried. Doing this helps to keep the inside of the unit dry and prevents mold from developing.
  4. Turn off the unit and pull out the plug.
  5. Replace the rubber stopper.
  6. Coil the wire and bind it together, then put it into the accessory space.
  7. Separate the vent pipe and store it safely.
  8. Cover the unit and keep it in a dry place.
  9. Take the batteries out of the remote control and store or dispose of them safely. Keep all accessories with the unit ready for next season.

TROUBLESHOOTING

  • Do not repair or disassemble the air conditioning.
  • Unqualified repair will invalidate the warranty and may lead to failure, causing injuries and property damage.
  • Only use it as directed in this user manual and only perform operations advised here.
Problems Reasons Solutions
The air conditioner does not work. There is no electricity. Turn it on after

connecting it to a socket with electricity.
The display shows “E7”.| Discharge the water inside.
The ambient temperature is too low or too high| Only use to usethemachinewithin the temperature range of 7-35oC(44-95oF).
In cooling mode, the room temperature is lower than the desired temperature| Change the desired temperature.
In dry mode, the ambient temperature is low.| The ambient temperature must be above 17 C. (62 oF).
The cooling effect is not good| There is direct sunlight.| Use curtains to reduce the direct sun heat
Doors or windows are open; there are a lot of people; or in cooling mode, there are other sources of heat (e.g. fridges)| Close doors and windows; increase air conditioning power
The filter screen is dirty.| Clean or replace the filter screen.
The air inlet or outlet is blocked.| Clear obstructions; make sure venting is correct as described in this user manual and the hose is not bent
Loud Noise| The air conditioning is not placed on a flat

surface.

| Put the air conditioning on a flat and hard place (to reduce noise).
The compressor does not work.| Overheat protection starts.| Wait for 3 minutes until the temperature is lowered, and then restart the machine.

The remote control does not work.

| The distance between the machine and the remote control is too far.| Let the remote control get close to the air conditioner, and make sure that the remote control directly faces the receiver.
The remote control is not aligned with the receiver.
Batteries are dead.| Replace batteries.
Others| No refrigerant or there is very little refrigerant| Refer to Service Centre (check leakage, wielding, vacuum pump, charge refrigerant according to nameplate)
Anti-freezing protection| Waiting for defrosting. The function will recover automatically. No user input is needed.
High-pressure protection| After the inside gas pressure comes down, it will function normally. No user input needed

If problems not listed in the table occur or recommended solutions do not work, please contact the service center.

ERROR CODES

CODE CAUSE SOLUTION
DH Unit in dry mode Not a fault, no action is required.
E4 Room temperature sensor error Check to ensure filters are clean, vent

pipe is not restricted, and room temperature is within operational range.
E2| Coil temperature sensor error
E7| Water full alarm| Empty the water tank
MODE LIGHT FLASHING| Cool/dry / heating mode, the compressor has not started, and the mode light will flash. This is normal| The unit will start operation when the protection period has finished ( approx. 3 minutes)

APPENDIX

Disposal:

  • Do not dispose of this product as unsorted municipal waste.
  • Collection of such waste must be handled separately as special treatment is necessary.
  • Recycling facilities are now available for all customers at which you can deposit your old electrical products.
  • Customers will be able to take any old electrical equipment to participating civic amenity sites run by their local councils.
  • Please remember that this equipment will be further handled during the recycling process, so please be considerate when depositing your equipment.
  • Please contact the local council for details of your local household waste recycling centers.

electric UK SUPPORT

  • www.electriQ.co.uk/support.
  • Please, for your convenience, make these simple checks before calling the service line. If the unit still fails to operate call the number below, or complete the online form.
  • 0871 620 1057
  1. Has the unit been standing upright for at least 2 hours?
  2. Is the unit plugged into the mains?
  3. Is the fuse OK?
  4. Switch the unit off and wait three minutes to see if the issue is resolved. Restart the unit.
  5. Check if the water tank is full.

CONTACT

  • Office hours: 9AM – 5PM Monday to Friday
  • www.electriQ.co.uk.
  • Unit J6, Lowfields Business Park
  • Lowfields Way, Elland
  • West Yorkshire, HX5 9DA

TECHNICAL DATA

Model EcoSilent10 EcoSilent10E EcoSilent8 EcoSilent8E
Capacity Cooling 2930 W 2350W
Rated Input 1090 W 870W
Running Current 5.0 A 4.0 A
Fan DC motor with 5 fan speeds.
Airflow 350m3/h
EER rate A
Refrigerant R290/280g R290/220g
Sound power level 61dB(A)
Thermostat 17-30oC
Maximum working pressure of suction/exhaust side 1.0/3.5MPa
Maximum Allowable Pressure 3.5Mpa
Power Supply AC 220-240V/50Hz
Net Weight 26kg 25kg
Dimension(LDH) 348364689mm

The unit must be vented outside when in Air Cooling mode. For EU regulation EN12102 this is a local air conditioner and produces less than 65dB(A) sound energy.

electric PORTABLE AIR CONDITIONER

  • ECOSILENT8
  • ECOSILENT8E
  • ECOSILENT10
  • ECOSILENT10E
  • 8,000 BTU
  • 10,000 BTU

Thank you for choosing electriQ
Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference. Visit our page www.electriQ.co.uk. for our entire range of Intelligent Electricals

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>