SunsGrove USACYN1033919 Wireless Adjustable Base Owner’s Manual
- June 16, 2024
- SunsGrove
Table of Contents
USA CYN 1033919
Wireless Adjustable Base
OWNER’S MANUAL Installation & Operation
Safety & Warranty Warnings
Attention: Read the following information before using this product .
Failure to use a surge protection device could compromise safety or cause
product malfunction and could void the electrical portion of your warranty.
Electrical surges are by far the biggest cause of problems with electrical
circuits.
In order to help protect your investment in case of a power surge or outage,
use an electrical surge protection device (not included).
WARRANTY WARNING!
Do not open or tamper with the transformer, control box, motors, or remote
control (with the exception of battery compartments). The product warranty
will be void if these components are tampered with.
SMALL CHILDREN AND PETS:
Immediately dispose of all packing materials as they can smother small
children and pets. Do not allow any persons or pets under the bed. Children,
convalescents and disabled person should not operate the bed without adult
supervision.
HOSPITAL OR CONVALESCENT USE DISCLAIMER:
Adjustable beds are designed and engineered for a life style of in-home
comfort and are not intended for hospital use or for a bed-ridden patient on
an extended recovery. Adjustable beds are not equipped with bars to help
patients get safely in and out of bed and are not intended to be used around
tent type oxygen therapy or explosive gases.
PRODUCT RATINGS:
The bed liG motors are not designed for continuous use of more than 2 minutes
in an 18 minutes period, or approximately 10% duty cycle. Any attempt to
circumvent or exceed this rating will shorten the life expectancy of the
product and may void the warranty.
WEIGHT UNITS:
The limitation for this adjustable bed is 700 Ibs. The bed will
structurally support these weights, provided weight is evenly distributed
across the head and foot sections. This product is not designed to support or
liG this amount in the head or foot section alone. Exceeding this weight
restriction could damage the bed and/or cause injury and void the warranty.
Enter or exit the bed in a tat position and do not sit on the head or foot
sections while in the raised position.
LIFTING AND LOWERING MECHANISMS:
It is normal for the raising and lowering feature on this bed to emit a
minimal humming sound during operation.
LOCATION ENVIRONMENT:
The level of sound experienced in a room is directly related to the
environment within that location. To reduce the resonance, place a piece of
carpet or rubber casters cups under the legs. The rubber caster cups also
prevent the bed sliding when located on smooth or hard surface tooling.
TO REDUCE THE RISK OF SHOCK, BURNS, FIRE OR INJURY:
Make sure the base is in a tat position and the vibrating motors are turned
off before unplugging the bed base from the power source. Always unplug the
base from the electrical outlet before cleaning or servicing the base . If the
cord or plug is damaged, discontinue use of the bed base.
FCC COMPLIANCE:
This device complies with part 15 of the FCC Rules for residential use.
Operation is subject to the following two conditions: (1) This device may not
cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
Radio Frequency: 2.4 GHz
USA CYN 1033919 PARTS LIST
Assembly Instrutions
Installation Guide
Two people are required to set up the foundation.
NOTE :To avoid damage to the foundation, always open the carton while the
bed is in the flat position.
Open the shipping box and carefully take out the bed frame from packaging and
open it .
TO INSTALL ALL LEGS :
- Thread the 6 bolt of the legs to the nut on the foundation frame, and tighten by hand. ( The legs are adjustable with 2 heights : 9 inch , 14 inch)
- Assembled the parts G (2 PCS) to the head of the foundation frame and tighten by the screws if assemble the bed headboard needed ( for installed the bed headboard required ) .
- Carefully turn the base over without placing weight on the legs , to prevent bending. Assembled the parts D & E by tighten parts F (3 PCS). Attention : Be careful when you turn over the base , lift up the below two parts together !
- Put the protect cover on the installed foundation frame. Secure the mattress retainer bar brackets .Secure the mattress retainer bar brackets.
- Uncoil the input power cord (connected to the control box’s power port) and plug it into the power supply
- Uncoil the power cord and connect it to the power supply.
USACYN 1033919 Remote Control Instructions
ADJUST – PRESS & HOLD
The HEAD arrows liG and lower the head section of the base.
The FOOT Warrows liG and lower the foot section of the base.
ONE TOUCH BUTTONS
One touch FLAT preset position.
One touch ZG preset position.
One touch programmable preset position.
One touch ANTI SNORE Preset Position
Setting Programmable Positions and Pairing Remote
SETTING PROGRAMMABLE POSITIONS
The wireless power bed has a programmable feature that allows you to save
custom positions. Please read all the instructions below before setting your
custom presets on the remote.
STEP 1
Adjust the head and foot to your desired position.
STEP 2
Then press and hold the MEMORY button for 5 seconds until you hear beeps
sound.
STEP 3
To adjust the saved position,repeat step 1 and 2 and the new position will bed
saved.
Pairing Remote
The original remote that comes in the box is already paired to the
foundation. No further action is required. In the event that the remote is not
paired with the foundation,follow the steps below .
Notice : Please do not sit on the bed to setting the programmable
position or pairing remote.
STEP 1
Make sure the batteries work fine, replace them when needed.
STEP 2
Plug power cord to the power source.
STEP 3
Press and hold head lowers and foot liG simultaneously, then press and hold
the blue button of plug cord for 3 seconds until your hear beeps sound, the
remote is then paired.
Synchronizing Two Bases
STEP 1
Plug base A and base B to power source.
STEP 2
- Press and hold head lowers and foot liG simultaneously of one of the remote control, then press and hold the blue button of plug cord of base A for 3 seconds until hear beeps sound , the remote is paired to base A
- Repeat the above actions, using the same remote control press and hold head lowers and foot liG simultaneously then press and hold the blue button of plug cord of base B for 3 seconds until hear beeps sound , the remote is paired to base A and base B.
STEP 3
Notice : The one bed base only following the one remote control , if you
want to operate the bed base separately,only need to pair the remote again.
Specific Degrees
Troubleshooting
In the event that the power foundation fails to operate, assess the symptoms and possible solutions provided in the chart below.
SYMPTOMS | SOLUTIONS |
---|
Remote control illuminates and appears to be operable, but will not activate
bed.| Verify that the power cord is plugged into a working, grounded
electrical outlet. Test the outlet by plugging in another working appliance.
No features of the power foundation will activate.| Program the remote control
(see the Setting Programmable Positions and Pairing Remote section of this
manual for programming procedures).
Unplug the power cord, wait 30 seconds and plug back to reset electronic
components.
The surge protection device or the electrical outlet may be defective. Test
the outlet by plugging in another working appliance.
Wireless remote will not illuminate.| Replace the batteries in the wireless
remote.
Head or foot section will elevate, but will not return to the horizontal (tat)
position.| Bed mechanism may be obstructed. Elevate bed and check for
obstruction. Remove obstruction.
Head section may be too close to the wall.
Headboard may be too close to the edge of the mattress. Verify that there is
enough distance between the headboard brackets and mattress. Adjust if
required.
Head & Foot liG function has minor interference during operation.| Check
bateries in wireless remote control, replace with two (2) new AAA bateries if
necessary.
Make sure that you are following the duty cycle of the motors (do not operate
more than two minutes over a 18-minute period, or approximately 10% duty
cycle).
Press the liG butons squarely and accurately.
Wireless remote control may be experiencing common Radio Frequency
Interference from other radio transmitting devices. Wait several seconds, and
then try pressing appropriate buton again.
A clicking noise is heard under the bed when raising or lowering.| This is
normal. The liG motor relays “click” when they are engaged. No action is
required.
References