YIPIN HEXHA DC 24V Step Down to DC 12V 30A 360W DC-DC Converter User Guide
- June 16, 2024
- YIPIN HEXHA
Table of Contents
YIPIN HEXHA DC 24V Step Down to DC 12V 30A 360W DC-DC Converter User
Guide
Warm Tip
①The load connected to the output of the power conditioner should not exceed
the maximum load power listed
②Do not reverse the polarity of the wiring. Otherwise the power supply will be
burned ou
③If there are multiple output lines, do not combine loads.
④Use a cable large enough to avoid voltage drops
⑤Leave room for the power supply to ensure long-termst able operation.
The converter can operate between -40° and 85°C. The converter is automatically protected when the case temperature exceeds 85°. When using this power supply, it should be placed in an environment with air circulation and as much cooling space as possible to extend its service life.
QUICK CONNECT TERMINAL
Wiring terminal instructions
Before using the quick connect terminal [please strip the wire with the core exposed 0.4 inch (about 10 mm)], and then insert the wire into the connector, be sure to insert in place