SOLAFANS 96V 65A MPPT Solar Charging Controller User Manual

June 16, 2024
SOLAFANS

SOLAFANS 96V 65A MPPT Solar Charging Controller

Specifications

  • Product Name: Solar Charging Controller
  • Distance of Communication: 1km
  • Maximum Power Point Tracking (MPPT) Technology
  • Input Voltage Range: 11-15V
  • Output Voltage Range: 11-15V

Product Description

The Solar Charging Controller is designed to extract the maximum power from a solar array and charge the battery efficiently. It utilizes the Maximum Power Point Tracking (MPPT) technology to automatically track the maximum power point of the array, ensuring that the maximum energy is obtained from the solar array throughout the day.

Features:

  • Maximum Power Point Tracking technology for efficient charging
  • Increases charge current for higher system performance
  • Professional, high efficiency, and energy-saving design

MPPT Technology

The MPPT controller extracts the maximum power from the solar array by tracking the maximum power point. It does not require any user adjustment and automatically adjusts to changes in ambient conditions. By maximizing the energy input from the solar array, it ensures efficient charging of the battery.

Increased Current

The MPPT technique increases the charge current of the solar system. The energy input to the MPPT controller is equal to its output energy. The input voltage multiplied by the input current is equal to the output voltage multiplied by the output current.

Professional – High Efficiency – Energy Saving

The Solar Charging Controller offers advanced features compared to traditional controllers. It operates at the maximum power point of the solar array, reducing energy waste and ensuring optimal performance.

Controller Installation

Before installing the Solar Charging Controller, please consider the following:

Selection of Installation Position

When selecting the installation position, consider the size, environment conditions, and safety distance:

Size

Ensure that the installation location can accommodate the size of the controller. Environment Condition

Choose a location that is suitable for the environmental conditions, such as temperature and humidity.

Safety Distance

Maintain a safety distance between the controller and other components to ensure proper ventilation and prevent overheating.

FAQ

Q: What is the maximum communication distance of the Solar Charging Controller?

A: The maximum communication distance is 1km.

Q: Does the MPPT controller generate current?

A: No, the MPPT controller does not generate current. The energy input to the MPPT controller is equal to its output energy.

Q: Can I use the Solar Charging Controller with a 12V system?

A: Yes, the Solar Charging Controller is compatible with a 12V system. The range of battery voltage is usually 11-15V, which is suitable for the controller’s operation.

Q: How does the MPPT controller reduce energy waste?

A: The MPPT controller always operates at the maximum power point of the solar array, reducing energy waste compared to conventional controllers that do not always operate at the maximum power point.

Product Description

Thank you very much for choosing our MPPT controller. The new generation MPPT which
we produce, it is the brand new product developed based on the newest technology which represents the newest high-level photovoltaic development. Excellent performances are listed as below:

  • Excellent heat dissipation design and cooling fan of intelligent control;
  • Creative maximum power point tracking technology can significantly increase the energy utilization rate of the solar system and can reach transfer efficiency of 97%;
  • Quickly scan the entire I-V curve; track the maximum power point within several seconds;
  • Three types of lead-acid batteries include sealed, Gel, AGM, Flooded and lithium battery series charging program can be selected;
  • Controller protection function: over charge, over discharge, over-load, short circuit self-protection;
  • RS485 communication interface realizes multi-machine communication with communication distance of 1km and communication with host computer which enables you to check operating parameters of controller conveniently.

The controller is used in solar off-grid system (independent system) which automatically switches to the mode of charge or discharge. MPPT controller has an advanced tracking algorithm to obtain the maximum power of the solar cell module so as to charge battery; at the same time, its low-voltage disconnect (LVD) function can prevent the damage caused by over-discharge of the battery. The charging process of MPPT controller’s battery is optimized which can extend battery Life and improve system performance. Its comprehensive self- test function and electronic protection function can avoid damage caused by installation error and system fault. Although the TY-series MPPT controller is easy to operate and use, it would be better for you to take some time to learn the instructions and specification of this manual in order to use all the functions better improve your PV system.

The features of the maximum power point tracking technology

Our MPPT controller utilizes maximum power point tracking technology to extract the maximum power from the solar array to charge the battery. The maximum power point tracking mode is fully automatic and does not require user to adjust. When the maximum power point of the array changes with ambient conditions, the controller automatically tracks the maximum power point of the array to ensure that the maximum energy of the day is obtained from the solar array.

Increase current

In most cases, the maximum power point tracking technique will “increase” the charge current of the solar system. Assuming that a system may have 10 amps of current flowing from the solar array into the MPPT controller and 12 amps of current flowing from the MPPT controller into battery. MPPT controller does not generate current! The energy input to the MPPT controller is equal to its o utput energy. Since the power is the product of voltage and current (volts x amperes), the following situations are true:

  1. MPPT controller input energy = MPPT controller output energy
  2. Input voltage x Input current = Output voltage x Output current

Assume that the efficiency is 100% and ignore the power loss caused by wire and conversion. If the maximum power point voltage Vmp of the solar array is larger than the battery voltage, the battery charge current must be proportionally larger than the solar array output current so that the input and output power can be balanced. The greater the difference between the Vmp voltage and the battery voltage, the greater the current boost. Current boost is extremely important in the system because the maximum power point voltage Vmp voltage of the solar panel in the solar power system is usually higher than the battery voltage.

The advanced condition compared with traditional controller.

The traditional controller directly connects the solar array to the battery when charging. It requires the solar array to operate normally below the Vmp voltage range. Take 12V system as an example. The range of battery voltage is usually 11-15V, but the Vmp voltage of solar array is usually about 16 or 17V.
The diagram below shows curve of current, voltage and output power of off-grid solar battery of typical nominal rated voltage 12V .

SOLAFANS-96V-65A-MPPT-Solar-Charging-Controller-fig-1

Nominal 12V solar cell I-V curve and output power diagram

Maximum power point voltage Vmp of solar PV array is the voltage of maximum output power (Amp x Volts), which is showed in the “knee” of the left diagram of above,the solar PV array I-V curve.
Since the conventional controller does not always operate in the solar PV array Vmp, the energy is wasted which originally can be used to charge battery and supply power to the system load. The greater the difference between the battery voltage and the Vmp of the solar PV array, the more energy will be wasted. The MPPT controller will always operate at the maximum power point which reduces energy waste compared with conventional controllers.

The limitating factor of the maximum power point tracking controller:
The Vmp of the solar PV array will decrease as the temperature of the array increases. In hot weather, Vmp may be close to or even lower than the battery voltage. In this case, the MPPT controller will have little or no access to energy compared with conventional controllers. However, as long as the nominal voltage of the system PV module is higher than the battery voltage, the Vmp of the PV module will be always higher than the battery voltage. In addition, decrease of the current of the solar array saves wires which enables the MPPT controller also has obvious advantages even in hot weather.

Matters needing attention

This manual describes the operation related to the MPPT solar charge controller.

  1. Effectiveness
    This manual is applicable to all models of MPPT solar charge controller of our company

  2. Target groups
    This manual applies to installers and operators

  3. Before installing and operating the controller, please read this manual and keep it carefully.

  4. Symbol Description

The followings are descriptions of the type of logo that appears in this manual:

  • Warning!
    If not avoided, it might lead to the machine failure or accident

  • Danger!
    If not avoided, it might lead to the machine failure or accident

  • Attention!
    In order to operate MPPT controller effectively, please read the controller operating instructions carefully.

Safety instructions

Warning!

  • Input voltage range of this controller is large. It will lead to personal injuries if it is not operated cautiously;
  • All work on the charge controller must be carried out by a technician;
  • The device can not be operated by children or people lack of body sensibility and those who are poor in their minds, lack of experience and knowledge of the operation; Keep away from children and make sure children can not touch.

Warning!
High heat shell parts.

Please install in a well ventilated environment.

Warning!
Radiation is harmful to health
Do not stay near the solar charge controller within 20cm for a long time.

Logo Description
T his section shows all instructions displayed on all device labels.

Logo

Instruction:
Risk of electric shock;
The energy stored in the capacitor will remain after five minutes of disconnection, and after the break, do not touch internal components within 5 minutes.

  • There is not self-repair parts inside the machine, so do not try to remove the cover; only professional personnel can operate and maintain the equipment; please use the insulation tool to drop risk of harm during operation.
  • Beware of high heat shell;
    The solar charger controller becomes hot during operation. Avoid contact during operation; It is forbidden to place any items on the equipment and to block the fan vents.

Safety instructions
When using this equipment, please keep the following information in mind so as to avoid fire, lightning or other personal injuries:

Warning!
Make sure that the input DC voltage = the specified maximum voltage, the voltage is too high may cause permanent, Damage to the solar controller, the above situation will not be included in the warranty period. This chapter contains important safety and operating instructions. Read and keep this manual for future use.

Warning!
The technician if you want to maintain or clean the solar controller or connect to the circuit, must first follow the relevant steps.

  • Before using the solar charge controller, read all instructions and warning signs on the solar charge controller and the corresponding sections of this manual
  • Please use the parts recommended or sold by our company
  • Make sure the existing lines are in good conditions and wire size are suitable in order to avoid the risk of fire and electric shock; do not operate when solarcontroller is damaged and wiring is qualified;
  • Do not disassemble the solar charge controller by yourself. Attempts to repair a solar charge controller may result in further risk of damage or accident and loss of quality of warranty;
  • Keep away from flammable and explosive materials in order to avoid fire;
  • The installation location should be kept away from moisture or corrosive substances;
  • In order to reduce the rate of short circuit, the technician must use the insulation tool to operate the equipment.

Included components

The following accessories are included after purchasing the equipment

Item Quantity Remark
Controller 1
Screw 4 Options
communicaton wiring/disk 1 Options
Temperature sensor 1
User Manual 1

Please contact distributor when you find the missing parts.

Check if it is damaged during transportation
After receiving device, please do not rush to sign at first, please open the sealing and check whether there is damage or crack appearance, if there is, please refuse to sign and contact distributor.

Charging controller
The label of charging controller is pasted on the side of case, If you find the device does not matched the one you purchase, please contact distributor.

Controller Installation

Installation must be done by professional technician.

Selection of installation position

| Danger:

The case of charging controller will become hot during operation.

Do not install on the flammable building material; Do not install nearby the highly flammable material;

Do not install in the potentially dangerous explosion area;

Do not install the charging controller in direct sunlight in order to avoid the loss caused by overheating.

---|---
!| Warning:

The controller has built-in thermal storage module components.

Do not touch the controller while it is working and the case is open.

Size

Model 20A 30A 40A 45A 55A 65A 70A 80A 100A 120A
Size                  
N.W.                  
G.W.                  

Environmental Condition

  • Install on solid surface;
  • Installation position must be approachable anytime;
  • Installation position can be removed anytime;
  • Only temperature of -20°C~ 50°C can confirm the best working environment;
  • Do not install the charging controller in direct sunlight in order to avoid power damage causedby overheating.

Safety Distance
Observe the following safety gap, make sure other equipment or object are not in this range and make sure there is enough room for heat dissipation.

SOLAFANS-96V-65A-MPPT-Solar-Charging-Controller-fig-2

MPPT Controller Connection

 | Danger!

If it is input high voltage and operation is not correct, solar charge controller may lead to life-threatening.

Disconnecting the solar panels should use a circuit breaker and avoid accidental activation.

Disconnect the circuit breaker and make sure it can not be connected again; Make sure there is no voltage in system.

---|---

| Warning::

Over-voltage can damage system

Thunderstorms and lightning will increase the risk of damage to external over- voltage protection areas.

Solar Charging System components

SOLAFANS-96V-65A-MPPT-Solar-Charging-Controller-fig-3

Wiring

Wiring Steps

SOLAFANS-96V-65A-MPPT-Solar-Charging-Controller-fig-4

Battery Connection

Warning: Short circuit of battery’s positive and negative terminals and wires of positive and negative electrode will lead to fire or risk of explosion. Please operate carefully.

SOLAFANS-96V-65A-MPPT-Solar-Charging-Controller-fig-5

Attention: The operation of connecting batteries must be done under the situation that the circuit breaker is disconnected.

DC Load Connection
The DC load terminal can be connected to a rated working voltage appliance, which is a DC electric appliance with the same voltage as the battery. The controller supplies electricity based on battery voltage.

SOLAFANS-96V-65A-MPPT-Solar-Charging-Controller-fig-6

Photovoltaic modules connection

Warning: Electric shock danger! Photovoltaic modules may produce very high voltage, so be careful electric shock when wiring.

Controller can match 12V, 24V, 48V off-grid system solar modules, it’s also can use a grid-connected modules that open-circuit voltage does not exceed the specified maximum input voltage. The solar modules voltage in the system must be not lower than the system voltage.

SOLAFANS-96V-65A-MPPT-Solar-Charging-Controller-fig-7

Attention: The operation of connecting photovoltaic modules must be done under the situation that the circuit breaker is disconnected.

Specifications of cable and miniature circuit breaker

Specification 20A 30A 40A 45A 55A 65A 70A 80A 100A 120A
Cable 4mm² 6mm² 6mm² 10mm² 10mm² 10mm² 10mm² 16mm² 25mm² 25mm²
2P circuit breaker 32A 32A 32A 63A 63A 80A 80A 100A 125A 125A

Temperature sensor and MPPT controller connected to PC

SOLAFANS-96V-65A-MPPT-Solar-Charging-Controller-fig-8

Rs485 communication wire is optional accessory
If necessary, install host computer software (need to be purchased separately). Accessories have detailed instructions for use and installation.

Power trial run

Attention: please make sure that all the positive and negative poles of the DC connection are connected correctly before the trial run,

Proceed as the followings

  1. Make sure that the positive and negative terminals of the cable are fully connected and measure if the open circuit voltage of the PV module is within the operating range of the controller;
  2. Turn on the circuit breaker connected with the controller and battery;
  3. Turn on the circuit breaker connected with the controller and solar panel;
  4. Then the controller starts to enter the self-test mode; if system conditions are correct, the controller automatically enter the working mode; If the system conditions are not correct, the controller will have fault indications, refer to the chapter of fault elimination.
  5. Battery type: the factory setting defaults lead-acid maintenance-free battery, refer to the battery type settings.

MPPT controller operating instructions

Surface show

No Name No Name
1 LCD Display 5 Wiring Cover
2 Charging indicator light 6 Up
3 Function Menu 7 Enter
4 Down 8 DC Load indicator light

Indicator Light State Description

Name State Description

Charging indicator

| Flashing| Maximum power tracking mode charging
Low Flashing| Float charging mode
Putout| Stop charging
DC Load indicator light| Lighting| Normal Output
Flashing| Battery undervoltage indication
Putout| Stop output

LCD Display

Main interface

SOLAFANS-96V-65A-MPPT-Solar-Charging-Controller-fig-10

SOLAFANS-96V-65A-MPPT-Solar-Charging-Controller-fig-32

SOLAFANS-96V-65A-MPPT-Solar-Charging-Controller-fig-11

SOLAFANS-96V-65A-MPPT-Solar-Charging-Controller-fig-33

View the Main Interface
In the default main interface, press DOWN or UP to look through other interfaces.

SOLAFANS-96V-65A-MPPT-Solar-Charging-Controller-fig-12

Main Menu
In the default main interface, press MENU to enter the main menu and press DOWN or UP to view the submenu.

SOLAFANS-96V-65A-MPPT-Solar-Charging-Controller-fig-13

Main Menu

SOLAFANS-96V-65A-MPPT-Solar-Charging-Controller-fig-14

Parameter settings

Language setting

In the default main interface, press MENU to enter the main menu, press ENTER to enter the language setting, press DOWN to select the language and then press the ENTER key to confirm and press MENU to return to the main interface after hearing continuous indicative sound.

SOLAFANS-96V-65A-MPPT-Solar-Charging-Controller-fig-15

Time and Date Settings

In the default main interface, press MENU to enter the main menu, press DOWN to select the time setting, press ENTER to enter time setting, press UP to move the cursor, press DOWN to modify the value, press ENTER after confirming the modified value and press MENU to return to the main interface after hearing continuous indicative sound.

SOLAFANS-96V-65A-MPPT-Solar-Charging-Controller-fig-16

Contrast Setting
In the default main interface, press MENU to enter the main menu, press DOWN to select the contrast setting, press ENTER to enter the contrast setting, press DOWNto reduce the contrast, press UP to increase the contrast, press ENTER to confirm and press MENU to return to the upper menu and the main interface after hearing continuous indicative sound .

Contrast Setting

SOLAFANS-96V-65A-MPPT-Solar-Charging-Controller-fig-17

Brightness Setting

The operations of brightness setting are the same with contrast setting.

Sound Setting
In the default main interface, press MENU to enter the main menu, press DOWN to select the sound setting, press ENTER to enter the sound setting, press DOWN to select the whether the key sound is on or off, press UP to move the cursor to select whether the alarm sound is on or off, press ENTER to confirm and press MENU to return to the main interface after hearing continuous indicative sound.

SOLAFANS-96V-65A-MPPT-Solar-Charging-Controller-fig-18

Record Query

In the default main interface, press MENU to enter the main menu, press DOWN to select record query, press ENTER to enter record query, press DOWN or UP to select the curve record query or fault record query, press ENTER to enter the curve record query or fault record query, press DOWN or UP to check the record and there are 10 records totally. Press MENU to return to the upper and main interface.

Record Query

SOLAFANS-96V-65A-MPPT-Solar-Charging-Controller-fig-19

Delete Record
In the default main interface, press MENU to enter the main menu, press DOWN to select the delete record, press ENTER to enter the delete record, press UP to move the cursor, press DOWN to select whether to delete, press ENTER to delete after selecting and press MENU to return to the upper menu and main interface after hearing continuous indicative sound.

SOLAFANS-96V-65A-MPPT-Solar-Charging-Controller-fig-20

System Information Query
In the default main interface, press MENU to enter the main menu, press DOWN to select the system information, press ENTER to enter the system information, press MENU to return to the main interface.

SOLAFANS-96V-65A-MPPT-Solar-Charging-Controller-fig-21

DC Output Setting

In the default main interface, press MENU to enter the main menu, press DOWN to select the DC output setting, press ENTER to enter the DC output setting, press DOWN to select OFF, Automatic and Time Control. When selecting OFF or Automatic, press ENTER. When selecting Time Control, please set the time period of opening and closing DC Output. Press DOWN to select Time Controland press UP to move the cursor. Press DOWN to input time value. Press ENTER to confirm and press MENU to return to upper menu and main interface after hearing continuous indicative sound.

Note: The key OFF refers to directly turn off the DC output. Automatic refers to turn on the DC output after the MPPT controller connects battery. Except battery undervoltage, Time Control refers to turn on or off the DC output according to the time period set.

SOLAFANS-96V-65A-MPPT-Solar-Charging-Controller-fig-22

Communication settings

In the default main interface, press MENU to enter the main menu, press DOWN to select the correspondence setting, press ENTER to enter the correspondence setting, press UP to select the baud rate setting or the local address setting, press DOWN to set Baud rate and the local address value, press ENTER to confirm and press MENU to return to the upper menu and main interface after hearing continuous indicative sound.

SOLAFANS-96V-65A-MPPT-Solar-Charging-Controller-fig-23

Operating Parameter Setting

Note: The operating parameter setting must be operated by qualified technicians. The MPPT controller will not work or suffer from damage of battery due to wrong operation.

In the default main interface, press MENU to enter the main menu, press DOWN to select the operating parameter setting, press ENTER to enter the password prompt interface, enter the password and then press ENTER to enter the operating parameter setting.

SOLAFANS-96V-65A-MPPT-Solar-Charging-Controller-fig-24

Note: Before setting the operating parameters, you must disconnect the circuit breaker which connects the PV module with the MPPT controller, set 5 parameters: battery type, rated voltage setting, charging voltage setting, charging current setting, discharging lower limit setting, check if parameters displayed on the system information are corresponding and then turned on the PV module circuit breaker.

Battery type setting

In the operating parameters interface, press ENTER to enter the battery type setting, press DOWN to select battery type (Maintenance-free lead acid battery, Gel battery, liquid battery, lithium series battery ), press ENTER to confirm and press MENU to return to upper menu after hearing continuous indicative sound.

Factory setting defaults to maintenance-free lead acid.

SOLAFANS-96V-65A-MPPT-Solar-Charging-Controller-fig-25

Battery rated voltage setting

In the operating parameters interface, press DOWN to select rated voltage setting, press ENTER to enter rated voltage setting interface, press DOWN to select voltage level (Automatically identify, 12V, 24V, 36V, 48V), press ENTER to confirm and press MENU to return to upper menu after hearing continuous indicative sound.

SOLAFANS-96V-65A-MPPT-Solar-Charging-Controller-fig-26

Factory setting defaults to automatically identify the level of rated voltage which can only identify lead acid battery but lithium series battery are not included. When automatically identify the level of rated voltage, charging voltage and discharging lower limit voltage setting are not available. Charging voltage and discharging lower limit voltage setting are only available for manual setting.

Charging voltage setting

In the operating parameters interface, press DOWN to select charging voltage setting, press ENTER to enter rated voltage setting interface, press UP to move cursor, press DOWN to input numeral, press ENTER to confirm and save and press MENU to return to upper menu after hearing continuous indicative sound.

SOLAFANS-96V-65A-MPPT-Solar-Charging-Controller-fig-27

Lithium battery series only have float (constant voltage ) charging mode.
Equalized charging mode can be only used for lead acid battery.

Charging current setting

In the operating parameters interface, press DOWN to select charging current setting, press ENTER to enter charging current setting interface, press UP to move cursor, press DOWN to input value, press ENTER to confirm and save and press MENU to return to upper menu after hearing continuous indicative sound.

SOLAFANS-96V-65A-MPPT-Solar-Charging-Controller-fig-28

The setting point of charging current can not be greater than the current maximum value.

Discharge limited setting

In the operating parameters interface, press DOWN to select discharging limitation setting, press ENTER to enter discharging limitation setting interface, press UP to move cursor, press DOWN to input value, press ENTER to confirm and save and press MENU to return to upper menu after hearing continuous indicative sound.

SOLAFANS-96V-65A-MPPT-Solar-Charging-Controller-fig-29

Restore Factory Setting

In the operating parameters interface, press DOWN to select factory reset, press ENTER to enter factory reset interface, press DOWN to select whether to restore factory setting, press ENTER to confirm and save and press MENU to return to upper menu after hearing continuous indicative sound.

SOLAFANS-96V-65A-MPPT-Solar-Charging-Controller-fig-30

When MPPT solar controller can not operate normally due to fault of operating parameter setting, please restore the operating parameters to factory setting.

Password

Press DOWN for 3 times and then UP for 3 times and press ENTER to enter operating parameters setting interface.

Technical Parameters

Specification

Parameters

|

20A

|

30A

|

40A

|

45A

|

55A

|

65A

|

70A

|

80A

|

100A

|

120A

---|---|---|---|---|---|---|---|---|---|---
Charging mode| MPPT automatic maximum power point tracking
Charging method| 3 stages: Constant charge(MPPT), Equalizing charge, floating charge

The voltage range of system identification 12V\24V\48V\60V\72V\96V

| 12V system( DC9V~DC15V) :24V system( DC18V~30V) Auto
48V system( DC36V~DC60V) :96V system( DC72~120V) Auto
60V system( DC45V~DC75V) :72V system( DC54V~90V) Manual set
Soft-startup time| ≤ 10s
Dynamic response recovery time| ≤ 500us
Static power| ≤ 2W
MPPT efficiency| ≥ 96.50%
PV modules utilization rate| ≤ 99.00%

MPPT working voltage range

| 12V system: DC18V~150V| 24V system: DC36V~150V
48V system: DC65V~150V| 60V system: DC75V~180V
72V system: DC90V~180V| 96V system: DC130V~180V

Under voltage input protection point

| 12V system DC16V| 24V system DC30V
48V system DC60V| 60V system DC75V
72V system DC90V| 96V system DC120V

Under voltage input recovery point

| 12V system DC18V| 24V system DC34V
48V system DC65V| 60V system DC80V
72V system DC96V| 96V system DC130V
Input voltage lim it| 12V/24V/48V:DC170V| 60V/72V/96V:DC225V
Input over voltage proection| 12V/24V/48V:DC175V| 60V/72V/96V:DC230V
Input over voltage recovery| 12V/24V/48V:DC170V| 60V/72V/96V:DC225V
Output characteristic| The DC load output voltge is same as battery voltage
Selectable battery type (The default battery is Lead acid battery)| 1, VRLA (Lead acid battery/鉛酸蓄電池).

2, Gel VRLA (Gel battery/コロイド電池). 3, Liquid (Lead acid liquid battery/

えきたいでんち). 4, Li-ion (Lithium/Lifepo4 battery/リチウム電池)

PV maximum input power| 20A| 30A| 40A| 45A| 55A| 65A| 70A| 80A| 100A| 120A
12V system| 280W| 410W| 550W| 610W| 750W| 890W| 960W| 1100W| 1375W| 1650W
24V system| 550W| 820W| 1100W| 1220W| 1500W| 1780W| 1920W| 2200W| 2750W| 3300W
48V system| 1100W| 1640W| 2200W| 2440W| 3000W| 3560W| 3840W| 4400W| 5500W| 6600W
60V system|  |  |  | 3050W| 3750W| 4450W| 4800W| 5500W| 6875W| 8250W
72V system|  |  |  | 3660W| 4500W| 5340W| 5760W| 6600W| 8250W| 9900W
96V system|  |  |  | 4500W| 5500W| 6500W| 7700W| 8800W| 11000W| 13200W
Specification

Parameters

|

20A

|

30A

|

40A

|

45A

|

55A

|

65A

|

70A

|

80A

|

100A

|

120A

---|---|---|---|---|---|---|---|---|---|---

Floating charge voltage (Lead acid battery)

| 12V system: 13.80V (or Customizable)
24V system: 27.60V (or Customizable)
48V system: 55.20V (or Customizable)
60V system: 69.00V (or Customizable)
72V system: 82.80V (or Customizable)
96V system: 110.4V (or Customizable)

Equalized charge voltage (Lead acid battery)

| 12V system: 14.50V (or Customizable)
24V system: 29.00V (or Customizable)
48V system: 58.00V (or Customizable)
60V system: 72.500 (or Customizable)
72V system: 87.00V (or Customizable)
96V system: 116.0V (or Customizable)
Rated current| 20A| 30A| 40A| 45A| 55A| 65A| 70A| 80A| 100A| 120A
Current-limiting protection| 22A| 32A| 42A| 47A| 57A| 67A| 72A| 82A| 102A| 122A
Output voltage accuracy| ≤ ±1.5%
LCD display| Reference LCD display instructions for details
LED display| Charging status, DC output on or off status indication
PC host computer (communication port)| Rs485 (Selection)
Low voltage input protection| Reference input characteristic
High voltage input protection| Reference input characteristic
Input polarity reverse protection| yes
Output polarity reverse protection| yes
Short circuit protection| After 5 trials start, it enters the protected state, reboot recovery
Overtemperature protection| When the temperature reaches 85℃, it will stop working
Temperature protection| When the temperature is over 80℃, it will reduce output power
Other parameters|
Noise| ≤ 50dB

Heat dissipation

| Forced air cooling, fan speed is adjusted by temperature, when the internal temperature is low, the fan runs slowly or stops, when the controller stops working, the fan stops running

Components

| The components are imported and in line with EU standards. The rated temperature of all selected electrolytic capacitors are not less than 105℃
Smell| No peculiar smell and harmful to health odors
Environmental requirement| Meet 2002/95/EC requirements; No cadmium, cyanide and fluoride
Specification

Parameters

|

20A

|

30A

|

40A

|

45A

|

55A

|

65A

|

70A

|

80A

|

100A

|

120A

---|---|---|---|---|---|---|---|---|---|---
Size| The details are on the random label
Gross weight( kg)| The details are on the random label
Net weight( kg)| The details are on the random label
IP Grade| IP21
Humidity| 0~90%RH (Not condensation)
Altitude| 0~3000m
Environment temperature| – 20℃ ~+40℃
Storage temperature| – 40℃ ~+70℃
Atmospheric pressure| 70~106kpa
Proposed configuration of photovoltaic modules|

System voltage

|

PV module operation voltage( Recommended value)

12V system

| 18V~~150V (Recommend 30V PV modules connection in one series or 36V PV modules connection in one series)

24V system

| 36V~~150V (Recommend 30V PV modules connection in two series or 36V PV modules connection in two series)

48V system

| 72V~~150V (Recommend 30V PV modules connection in three series or 36V PV modules connection in three series)

60V system

| 72V~~180V (Recommend 30V PV modules connection in four series or 36V PV modules connection in four series)

72V system

| 90V~~180V (Recommend 30V PV modules connection in five series or 36V PV modules connection in four series)

96V system

| 120V~~180V (Recommend 30V PV modules connection in six series or 36V PV modules connection in five series)

Photovoltaic power-Conversion efficiency curve

SOLAFANS-96V-65A-MPPT-Solar-Charging-Controller-fig-31

Maintenance & Cleaning

Fuse Replacement
Fuse blown due to excessively high temperature or other faults needs the correct replacement:
pull out the broken fuse from the joint, install the new fuse, check if it is connected correctly and then install equipment.(Fuse is near the connecting box)

Clean fan vent & heat sink
Please regularly clean fan vent and internal heat sink with dry or slightly wet cloth. Please pay attention that washing liquid or corrosive solvent are banned for cleaning and liquid is not allowed to flow into machine to make sure that the air vents are not blocked.

Fault Elimination

When the controller works abnormally, please check conditions listed as below

Fault Situation Fault Elimination

When controller is electrified for the first time, fault prompts: battery voltage is out of normal range| 1.  Check whether the battery voltage is in the range of system voltage identification (See technical parameters for system voltage identification range)

2.  Manually set rated battery voltage level (See the rated battery voltage setting in the operating parameters setting)

Fault indication: over temperature protection

| 1. Check whether the cooling fan is damaged and ventilation vents are blocked by debris; MPPT controller should be installed in a ventilated environment

2. Reasonable PV module configuration can improve conversion efficiency and reduce temperature rise (technical parameters PV module configuration)

Fault indication: battery over discharging protection| The battery is out of power
Fault indication: can not test external temperature sensor| 1 Check whether it is connected to the external temperature sensor. 2 check whether the sensor contact is bad

Charging indicative light and displays of charging current and charging power are off and on

| 1 Check whether PV module voltage is in the MPPT operating voltage range.

2  Check whether the charging voltage parameters shown on system are correct. 3 Correct the charging voltage parameters or restore the factory settings

to restart dynamic MPPT controller.

4 Check whether the fuse is broken and the circuit breaker is disconnected.

Charging indicative light is off and on alternatively; charging current appears alternatively| This situation generally appears in cloudy day or evening when the light is insufficient which is a normal phenomenon
No power curve and current curve display| Check whether the time and date of the MPPT controller are consistent with the time you are in.

(see time and date set)

If the problem is still on the table, please contact customer service personnel:
Please provide the following information: equipment: type, order number, serial number (the label on the back plate); a detailed description of the problem (such as the use of the type system, problems occurred occasionally or frequently, indicating light, display etc.)

Quality Warranty

During the warranty period, our company will repair for free or replace with new products

Evidence
During the quality warranty period, our company requires customers to provide invoices and date of purchased products.
At the same time the trademark on the product should be clearly visible, otherwise we have the right not to guarantee quality.

Condition

  • The rejected products shall be disposed of by our company
  • The customer shall allow reasonable time to repair the faulty equipment

Exemption From Liability
In the following cases, our company will be not responsible for repair:

  • The whole machine or spare parts are beyond the warranty period
  • Transport damage
  • Incorrect installation or modification
  • Operating in a very harsh environment described beyond this manual
  • Failure or damage to the machine caused by the service, repair, alteration or removal of our company
  • Abnormal natural environmental damage

If customers ask for amendment service due to problems caused by faults listed above, our company can provide compensable amendment service after judgment of our service constitute.

Note
The change of product size and parameter is subject to the newest information of our company without further notice.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals