TAKARA BELMONT Yume Noble Washing System Instruction Manual

June 16, 2024
TAKARA BELMONT

TAKARA BELMONT logo YUME ESPOIR
YUME SUITE
YUME NOBLE
Installation Instructions

Yume Noble Washing System

  • Basin body
    EX-ESYM* [For Back wash (same as YUME basin)]

  • Seat body
    SC-ESF [ESPOIR Fixed Legrest] SC-ESL [ESPOIR Movable Legrest] SC-YMSIN* [SUITE]

  • Seat
    SU-ESB [ESPOIR Basic] SU-YMSI [SUITE] SU-YMNB*[NOBLE]

  • Base plate
    EA-ESBP

TAKARA BELMONT Yume Noble Washing SystemTAKARA
BELMONT Yume Noble Washing System ImageTAKARA BELMONT Yume Noble Washing System Image
1 To the installer

  • The instructions should be thoroughly read and  understood before installation to ensure that the product is installed correctly.
  • After installation, give these instructions to the customer.

To the customers

  • Customers must not install the product by themselves.

  • Customers must store these instructions in a safe place so as not to lose them.

  • The actual shape of the product and the images and dimensions listed in these instructions may be modified and are subject to change without notice.

    • The precautions listed here are to ensure that the product can be installed safely, and to prevent any danger or risk to the person installing the product or those around them. All of these precautions are important for safety. Takara Belmont is not responsible for any damage or risk to the person installing the product or those around them due to accidents if the product is installed without adhering to the precautions.

Precaution
If the product is installed after ignoring this symbol, “there is the risk of light or moderate injury or physical damage”.

Before installation

Overall layout diagram : YUME ESPOIR
Basin body: EX-ESYM* [For Back wash (same as YUME basin)] Seat body: SC-ESBF [ESPOIR fixed legrest] Seat: SU-ESB[ESPOIR Basic]

  • Top view

TAKARA BELMONT Yume Noble Washing System - Top view Side viewTAKARA BELMONT Yume Noble Washing System - Side
view

  1. The dimensions listed above may vary slightly from product to product.
  2.  Ensure that there is ample space surrounding the seat for extremely tall customers or if the surrounding area is used as a passageway.

TAKARA BELMONT Yume Noble Washing System - Side view 1 Overall layout diagram : YUME ESPOIR
Basin body: EX-ESYM* [For Back wash(same as YUME basin)] Seat body: SC-ESBL [ESPOIR Movable legrest] Seat: SU-ESB [ESPOIR Basic] Top viewTAKARA
BELMONT Yume Noble Washing System - Side view 2 Side viewTAKARA BELMONT Yume Noble Washing System - Side
view 3

  1. The dimensions listed above may vary slightly from product to product.
  2. Ensure that there is ample space surrounding the seat for extremely tall customers or if the surrounding area is used as a passageway.

TAKARA BELMONT Yume Noble Washing System - Side view 4 Overall layout diagram : YUME SUITE
Basin body: EX-ESYM* [For Back wash(same as YUME basin)] Seat body: SC-YMSI [SUITE] Seat: SU-YMSI [SUITE] Top view

TAKARA BELMONT Yume Noble Washing System - Side view 5 Side viewTAKARA BELMONT Yume Noble Washing System - Side view
6

  1. The dimensions listed above may vary slightly from product to product.
  2.  Ensure that there is ample space surrounding the seat for extremely tall customers or if the surrounding area is used as a passageway.

TAKARA BELMONT Yume Noble Washing System - Side view 7 Overall layout diagram : YUME NOBLE
Basin body: EX-ESYM* [For Back wash(same as YUME basin)] Seat body: SC-YMSI [SUITE] Seat: SU-YMNB [NOBLE] Top viewTAKARA BELMONT Yume Noble Washing
System - Side view 8 Side viewTAKARA
BELMONT Yume Noble Washing System - Side view 9

  1. The dimensions listed above may vary slightly from product to product.
  2. Ensure that there is ample space surrounding the seat for extremely tall customers or if the surrounding area is used as a passageway.

TAKARA BELMONT Yume Noble Washing System - Side view
10 Power
To turn the power on, install the C-4 plug.
When the plug is changed due to a reason related to the customer, install a power plug that is suitable for the product.

[Rated current] [Rated frequency] [Rated electricity consumption]
230V Specifications 50/60Hz 1.9/1.6A

Connecting to ground
To prevent accidents from occurring in the unlikely event of electrocution, and to improve noise resistance within control circuits,
always install the ground designed for this product.

  • Do not connect the ground cable to any of the following:
  • Water pipes: any PVC pipes within the plumbing system will prevent a proper ground connection.
  • Gas pipes: there is a risk of an explosion or fire.
  • Telephone cables, lightning rods: there is a risk of a large current if there is a lightning strike.

Precaution
Handling power plugs
Check the power plugs are free from dust, and insert the plug all the way to the base so that there is no rattle. Dusty power plugs or improper connections can cause electrocution or fires.
Handling power cables
Do not subject power cables to excessive forces, modify, twist or bend them.
Power cables can become severed if they are placed under heavy objects or become trapped within tight areas, and can cause electrocution or fires.
Handling power outlets
Use power outlets for one appliance only, and always connect the ground terminal.
The use of multi-outlet extension cords can generate heat where the power outlet is divided, and can cause fires.
Handling circuit breakers and fuses
Always install a circuit breaker and fuse with the power outlet. Check that the white cable is neutral, and that the circuit breaker and fuse are connected properly to the neutral side of the power outlet. Installing circuit breakers off users incorrectly can cause electrocution.
Remove the power plug during inspections
Remove the power plug before conducting inspections or adjusting settings within the main body of this product. Coming into contact with electrical part while the power is connected may cause electrocution.
Floor surface

  • Ensure that the material or finishing of the floor surface is waterproof or has a waterproof coating applied.
  • Always ensure that the floor surface is horizontally level.
  • Ensure that the floor surface is smooth and free from bumps around the attachment areas.
  • Installing pipes

[Pipe specifications]

Hot water supply, water supply Rc 1 / 2“
Drain VU40 / VP40

[Height from floor]

  • Only height H is available for the Back Wash basin

| Underfloor pipe specifications
---|---
Hot water supply, water supply| 100 mm
Drain| 100 mm

  • If the floor surface is tiled, cracks may occur when fastening the bolts during installation of this product main body. If this looks likely to happen, use the main body attachment diagram and template as a reference and change the material of the attachment area that is in contact with the floor to another such as plywood or mortar.
    Take care during installation as the entire base surface of the seat body is not in contact with the floor.

  • The following levels of strength are required for the floor surface.

Wooden floor| Plywood thickness of 30 mm or more (two 15 mm sheets joined together)
---|---
Mortar floor| A foundation with levels of strength listed above around the installation areas is required.
Special floor (stone finish)| Mortar thickness of 50 mm or more

Preventing water leakage

  • If this product is to be installed upstairs, ensure that the installation area has been coated with waterproof materials (waterproof finish, installation of a stainless steel pan or a water leakage sensor).
  • Fill the space between the installation area and pipe with caulking materials.

Installation of pipes
The following are important points to adhere to during the installation of pipes.
Read through the details carefully and ensure that the pipes are installed correctly.

  • When installing this product, ensure that installation of pipes adheres to the instructions outlined in “Precautions during installation of pipes”. Installing pipes without reading through the precautions will mean water may not mix properly, and a set temperature will not be achieved.
  • This product is designed for indoor installation. Always install this product indoors.

Precautions during installation of pipes

  • Do not use pipes made of materials that may introduce rust for the water supply pipe.  In general, VP pipes or other materials specified by regulations in that particular region, are recommended for installation.

  • In general, Type L deoxidized copper pipes are recommended for hot water pipes.

  • In general, the same diameter and same pressure is recommended for hot water pipes and water supply pipes.

  • Always use a reamer to deburr the ends of cut pipes.

  • Avoid using inverted U-shaped pipes (siphon) as these can cause air to become trapped.

  • Always connect hot water pipes and water supply pipes after removing all contaminants such as dirt, sand and oil as these can cause problems.

  • After connecting the pipes and testing water flow, clean the filter and shower head.

  • Ensure that the drain pipe is installed at a gradient of 1/50 for a diameter of φ75 or less, or 1/100 for a diameter of φ75 or more.

  • Do not connect the hot water pipes and water supply pipes in reverse.
    Connecting pipes in reverse will mean the temperature of water cannot be controlled properly by the water taps, which can cause problems including burns.

  • Ensure that the hot water pipes from water boilers are only run over a short distance so as to minimize resistance. Longer pipes can cause fluctuations in temperature and poor hot water delivery.

  • Always wrap pipes with lagging material after installation is complete.

  • Water boiler pipes

  •  In general, the same diameter and same pressure is recommended for main hot water pipes and main water supply pipes.

  • Equipment comes with hair catchers installed.

Usage conditions

Hot water supply and water supply conditions

Water used| •Public water supply (do not use non-drinkable well water or water that contains rust or sand.)
•If the water hardness is 80 ppm or higher, install a water softener to prevent the buildup of scale within the basin body. Aeration may be minimal when using shampoo even if drinkable well water is used, so a water softener should be installed.
---|---
Hot water supply, water supply pressure| •Use a pressure set between 0.1 to 0.4 MPa (1 to 4 kgf/cm2). If multiple units of this product are used, ensure that the pressure does not drop below 0.1 MPa (1 kgf/cm2).
•Set the water supply pressure hot water supply pressure.
•Set the difference between the hot water supply pressure and water supply pressure to within 0.2 MPa (2 kgf/cm2).
Hot water temperature into the product| •Set the hot water temperature to 80°C or less.
•Set the temperature 10°C or higher than the shower temperature used.
Water boiler| •Do not use steam with the hot water supply.

Content of Packing

< Basin body>
Content of packaging
TAKARA BELMONT Yume Noble Washing System -
Packing* The Urea screws are held down the main body with the maintenance cover. (Urea screw M5 × 15)
Precaution
An air mat is attached to the basin, andprotective tape applied to the main body  cover. In order to protect the basin and main body cover, do not remove these until immediately before installation of the pipes.
AccessoriesTAKARA BELMONT Yume Noble Washing System -
Accesseries

  • Instruction manual, installation manual (this document)
  • YUME SPA Technical  Manual(except for China)

< Seat body>

  • Content of packaging

TAKARA BELMONT Yume Noble Washing System - Accesseries
1 < Seat>

  • Content of packaging
    【ESPOIR】
    [Fixed legrest type]

TAKARA BELMONT Yume Noble Washing System - Accesseries
2 Packaging shape and size, weight

Basin body 37 kg, Wood frame 30 kg![TAKARA BELMONT Yume Noble Washing System - Accesseries 3](https://manuals.plus/wp-content/uploads/2024/01/TAKARA-BELMONT- Yume-Noble-Washing-System-Accesseries-3.jpg) Basin body 46.5 kg, Wood frame 30 kg![TAKARA BELMONT Yume Noble Washing System - Accesseries 4](https://manuals.plus/wp-content/uploads/2024/01 /TAKARA-BELMONT-Yume-Noble-Washing-System-Accesseries-4.jpg) Basin body 48 kg, Wood frame 30 kg![TAKARA BELMONT Yume Noble Washing System - Accesseries 5](https://manuals.plus/wp- content/uploads/2024/01/TAKARA-BELMONT-Yume-Noble-Washing-System- Accesseries-5.jpg) Basin body 48 kg, Wood frame 30 kg![TAKARA BELMONT Yume Noble Washing System - Accesseries 6](https://manuals.plus/wp-content/uploads/2024/01/TAKARA-BELMONT- Yume-Noble-Washing-System-Accesseries-6.jpg)

Carrying the main body

Carrying the basin

  1. Unpack the wood frame.
  2. Remove the maintenance cover from the main body.
    Remove the protective tape and the Urea screws from the maintenance cover.
  • Remove the maintenance cover keeping the protective tape taped to the main body cover.
    Precaution
    Do not lose the Urea screws holding down the maintenance cover.
    The Urea screws are used for holdimg down the maintenance cover  later.(see page 8)

    1. Remove the main body from the wood frame.
      Remove the screw attaching the base and skid while holding the basin. (4 points)
      Precaution
      Always have at least two people to carry the main body and hold the basin when remove the bold.

    2. When carrying the basin
      Do not take off the air mat and the protective tape.
      Carry the body by holding the edge of under the basin. Do not hold the main body cover. Always have two at least people to carry the main body. (see image on right)

TAKARA BELMONT Yume Noble Washing System - Maim Bpdy Carrying the seat

  1. Unpack the wood frame.

  2. Remove the seat from the wood frame.
    Remove the screw attaching the foot part and skid while holding the seat. (4 points)

  3. When carrying the seat
    Hold the specified points only. (see page 9)
    Always have at least two people to carry the seat. (see image on right)

Precaution

  • Never hold the backrest.
    Doing so may cause incorrect operation or malfunctions in the seat.

  •  Do not drag the seat.
    The feet of the seat are made of steel, so dragging it may damage the floor surface, damage the foot part, cause incorrect operation or malfunctions in the seat or toppling.

TAKARA BELMONT Yume Noble Washing System - Maim Bpdy 1

Installation of main body

  • The basin or seat may not be able to be installed correctly depending on installation procedures of the main body. Always install the main body using the following procedures.

    • Main body installation procedur e

TAKARA BELMONT Yume Noble Washing System - Procedre Precaution

  • Always use the template to mark the floor when fixing the basin and the seat. Also, always final confirm the fixing position of the seat by using the base plate H as a guideline.
  •  If the seat is to be fixed using anchor bolts, check the distance between the seat and the basin with the actual unit.

Install the basin

Installation

  1. Marking the bolt (anchor) fixing position
    Use supplied template to check and make preparations for the dimensions and method for installation of the piping.
  • If the power cable (for installation) is to be installed from the water supply pipe and drain pipe area, mark their position in the same way as below.
    (1) Place the supplied template on the floor and set it to the position of the water supply pipe, hot water supply pipe and drain pipe.
    (2) Mark the fixing position of the basin and seat bolts (anchor).
    (3) Drill out the fixing position holes for the basin bolts (anchor).
    (4) Remove the template from the floor.TAKARA BELMONT Yume Noble Washing
System - Procedre Basin

    1. Attach pipe gasket
      (1) Cut a slit in the pipe gasket to suit the position of the pipes to be installed.
      (2) Peel away the sheet from the adhesive surface of the pipe gasket and stick to the floor surface.
      (3) Cut out a circle around the slit cut in the pipe gasket to suit the pipe surface, and fill in any gaps with caulking materials.
      Precaution
      • Always attach pipe gasket and apply caulking materials to the areas around the pipes so that there are no gaps, in order to prevent condensation within this product or water seeping on the floor in the event of water leaks.
      • If pipe gasket is not used, condensation may cause water to pool on the floor, structural parts may start degrading and malfunctions may occur.
      • If the power cable (for installation) is to be installed from the water supply pipe and drain pipe area, apply caulking materials to any gaps in the same way as above.TAKARA BELMONT Yume Noble Washing System -
Gasket

    2. Install the basin
      (1) Hold the stepped section at the bottom of the basin, align it with the hole position that was opened previously, and install the basin.
      Precaution
      Do not pull the basin when attempting to move it. Doing so may damage the floor.

  • If the power cable (for installation) is being installed from the water upply pipe and drain pipe area, pass the cable through the gap in the center of the base and through to the seat side.TAKARA BELMONT Yume Noble Washing System - Gasket 1 * If the power cable (for installation) is being installed from the water supply pipe and drain pipe area, pass the cable through to the seat side. (able must be 1300 mm or longer from the installation 
    position) Precaution

    Ensure that the power cable (for installation) is not trapped by the base. Doing so may cause fires, electrocution or angled basin.
    (2) If the pipe gasket is trapped under the basin (base), move the basin away temporarily and cut the pipe gasket that is trapped.
    Precaution
    The basin may be installed at an angle, or may even topple over if the basin (base) is attached with the pipe gasket trapped underneath.
    (3) Attach the basin with bolts (anchor).
    Adjust the basin so that it is not installed at an angle.

Installation process for anchor bolts
Precaution

  • The strength of the anchor bolts will be reduced if they are hammered into the hole while touching the bottom. Open up a gap.
  •  When installing anchor bolts, insert them so that there is 2 to 5 mm of the threaded section of the head protruding. If the bolts are inserted with more than 5 mm protruding, the head may interfere with the cover.
  1. Drill open a hole of the specified diameter and depth.
  2. Remove the dust from each anchor hole by cleaning with a vacuum cleaner.
  3. Insert the anchor bolt and tap it with a hammer until the center pin makes contact with the base plate.
  4. Adjust the fastening strength of the nut using a wrench.

Attach piping

  1. Attach drain hose to installed drain pipe
    Precaution
    • Check that the drain hose is not bent or damaged. This may affect water flow or damage the drain hose.
    • Check that the drain hose clamp is firmly fastened. If it is not fastened, water may leak or the drain hose may come loose.
    • Check that the hose is not in the shape of an S trap. An S trap can adversely affect the flow of drainage water. If the drain pipe layout causes an S trap to be formed, check the installation position of the basin body and piping dimensions, and make the necessary adjustments.

TAKARA BELMONT Yume Noble Washing System - PipingTAKARA BELMONT Yume Noble Washing System - Piping
1 * Drain trap
If water leaks due to damage to the drain trap, contact your closest dealer or Takara Belmont directly. Attach the water supply pipe and hot water supply pipe
Precaution

  • Always connect the pipe after removing all contaminants on the pipe such as dirt, sand and oil.
  •  Check that the space around the pipe is completely filled with caulking materials.
  1. Check that pipe installation suits product specifications (position, pipe, height) and that it matches the pipe installation diagram and template. (see page 28)
  2. Attach the stop valve to the installed hot water supply pipe and installed water supply pipe. Take note of the orientation of the stop valve.
  3. Bend the flexible pipe to suit the position of the filtered check valve and stop valve.
  4. Insert the supplied packing to the flexible pipe and attach to the filtered check valve.
  5.  Insert the supplied packing to the flexible pipe and attach to the stop valve.TAKARA BELMONT Yume Noble Washing System - Piping 4

Precaution

  • When attaching the water supply pipe and hot water supply pipe, ensure that they do not come in contact with the basin pipes. Doing so will may cause water leaks.
  •  Always attach the supplied packing. Using this product without installing the supplied packing may cause water leaks.
  • Do not connect the hot water supply pipe and water supply pipe in reverse.
  •  Check that water is not leaking from the joint.

Checks after installation of pipes

  1. Test water flow
    Precaution
    Always test the water flow to prevent accidents during use.
  • Test the water flow and inspect the following items. The hot water may be slightly tainted at the start of the water flow test, however this does not indicate any problem.

  • For safety reasons, the product’s thermostat is designed so that the hot water does not exceed 53˚C.
    (if the supply pressure is the same, water is 20˚C and hot water is 60˚C)
    (1) Is there no water leaking from the pipe joints
    The pipe joints may come loose during transportation, so check the joints within the basin thoroughly.
    (2) Are the hot water supply and water supply pressures at the same, stable pressure If the pressure is not the same, see “How to adjust faulty temperature regulation” below.
    (3) Can temperature be controlled properly
    (4) Check that the shower outlet flow is sufficient, by the following as a guide for flow rate. Shower outlet flow rate
    Hot water supply pressure, water supply pressure : 0.1 MPa each
    Shower outlet temperature : 40˚C
    Dual function (shower): Approximately 10.0 L/min
    shower head (Aeration): Approximately 6.6 L/min

    1.  Clean
      After the hot water becomes clear during the water flow test, always clean the filter (within the check valve) and shower head.

Precaution
Failure to do so can result in insufficient flow rate and faulty temperature regulation.
Take care not to damage or lose the O-rings and gasket.
Remove and clean any dirt trapped within the shower head Remove and clean any dirt trapped within the filter pipe Attach the maintenance cover to the basin
Precaution
Take care not to hit or trap other parts when installing the cover.
Doing so may damage the parts and cause malfunctions.

  1. Insert the maintenance cover into the main body cover.
  2. Attach the cover with the screws.

(Urea screw M5 × 15, 1 pce)

  • The Urea screws are held down the main body with the maintenance cover. (see page 8 and 13)
  •  Attach the maintenance cover to the basin body in a position so that it is in contact with the floor.

Precaution
Attach the Urea screw by hand without using any tools. Using tools may cause damage to the plastic section.TAKARA BELMONT Yume Noble Washing System -
Precation 2 Install the seat
Installation
Precaution
Ensure that power cannot be turned on to the seat during the installation process.

  1. Install base plate H to the basin
    Press the ribbed section of base plate H to the base of the basin and fasten with the screws. (M6 × 20, 2 pcs, plastic washer (10 × 6), 2 pcs)
  • The plastic washers are supplied with the screws when the product is shipped. Check that the plastic washers have not come loose.

  • If the power cable (for installation) is being installed from the water supply pipe and drain pipe area, pass the cable through the bottom of base plate H and through to the seat side.
    Precaution
    Ensure that the power cable (for installation) is not trapped by base plate H. Doing so may cause electrocution or an angled seat body.
    Precaution
    Always attach the plastic washers. If the washers are not attached, water may leak through, making it difficult to remove the screws.TAKARA BELMONT Yume
Noble Washing System - Precation 3

    1. Install base plate H to the seat
      (1) Hold the specified section at the base of the seat (see page 9), press against the ribbed section of base plate H and fasten with the screws. (M6 × 15,2 pcs)
      Precaution
      • If the seat is attached using anchor bolts, check the distance between the seat and the basin with the actual unit.
      • When attaching the seat, always check that there are no large spaces due to warpage of base plate H or gaps between the floor. If the power cable (for installation) is to be installed from the water supply pipe and drain pipe area, apply caulking materials to any gaps in the same way as above.
      • Ensure that the power cable (for installation) is not trapped by the seat. Doing so may cause electrocution or an angled seat.TAKARA BELMONT Yume Noble
Washing System - Precation 4

    2. Install the seat
      <If the power cable (for installation) is being installed from the water supply pipe and drain pipe area>
      Pass the power cable (for installation) from base plate H through the bottom of the seat base and position at the plugging point.
      <If the power cable (for installation) is being installed from the floor under the seat>
      Pass the power cable (for installation), from the floor and position at the plugging point.
      Attach the seat with bolts (anchor). (see page 15) Check that the seat and basin are set in correct direction.
      Precaution
      • The strength of the anchor bolts will be reduced if they are hammered into the hole while touching the bottom. Open up a gap.
      • When installing anchor bolts, insert them so that there is 2 to 5 mm of the threaded section of the head protruding. If the bolts are inserted with more than 5 mm protruding, the head may interfere with the cover.

Remove PP band

Remove the PP band from the seat.
Precaution

  • Always remove this PP band. Operating this product with this PP band attached may cause incorrect operation or malfunctions in the seat.

  • When moving the seat body at a later date
    Precaution

    • If the seat is to be moved at a later date, always attach the PP band. If this PP band is not attached, the transportation handle (see page 9) cannot be fastened, which can cause malfunctions to the seat or injury.

TAKARA BELMONT Yume Noble Washing System - PP band Fix legrest and link

< SUITE >
(1)Remove the cable ties from the legrest. Fix legrest and link
< NOBLE >
Precaution
Always remove this cable ties. Operating YUME SUITE and NOBLE with cable ties attached may cause incorrect operation or malfunctions in the seat.
(2)Remove the two screws that are temporarily fixed to the legrest.
(3)Use the screws removed in
(2) to secure the legrest and link as shown in the figure on the right.
Precaution
Securely fix the leg rest part and the link so that there is no looseness.
Failure to do so may cause an injury, damage to the device, or abnormal noise.

Wiring

  1. Connect power cable
    <If connecting to a power cable (for installation) from the floor under the seat>
    <If connecting to a power cable (for installation) from the water supply pipe and drain pipe area>
    (1) Connect a power outlet to the power cable (for installation).
    (2) Insert the power plug from the seat into the power outlet.
  • When connecting the power plug into the power outlet, do it at the plugging point and bring it to the top of the base. (see page 28)TAKARA BELMONT Yume Noble Washing System - PP band 3
    (1) Fasten the power cable attachment tools to the base with screws. (M5 × 10, 2 pcs)
    (2) Disconnect the power plug of the seat at the connector and connect the connector of the extension power cable (sold eparately) to the seat connector.
    (3) Pass the extension power cable (sold separately) through the hole in base plate U.
  • The fastening methods for base plate U is outlined in number 2 below.
  • Always use the extension power cables (sold separately) specified by Takara Belmont.TAKARA BELMONT Yume Noble Washing System - PP band 4TAKARA BELMONT Yume Noble Washing System - PP band 5 2. Install base plate U to base plate H
    Spread open base plate U and attach to base plate H with screws. (M5 × 14, 2 pcs)
    Precaution
    Take care not to spread open base plate U too far.
    Spreading the base plate out too far can result in the deformation and damage.
    Precaution
    When installing base plate U, ensure that the power cable (for installation) is not trapped.

TAKARA BELMONT Yume Noble Washing System - PP band 6

Attach base cover

Precaution
Take care not to hit or trap other parts when installing the cover.
Doing so may damage the parts and cause malfunctions.

  • Check that there is no damage or dirt on the cover before installing it.
    If there are any problems found in preliminary checks, contact your closest dealer or Takara Belmont directly.

    1. Remove the oil plug from the oil tank.
    2. Attach base cover L and R to the seat
      (1)Attach plate for base cover to base cover L. (M4×10, 2 pcs) (Plastic washer(10×4), 2 pcs)

Tips
If you attach the plate vertically to the end face of the cover, it will be easy to fit with the hole of the base cover R.TAKARA BELMONT Yume Noble
Washing System - TakaraAttach base cover L and R to the seat.
(M5×30, 4 pcs)
(Plastic washer (10×5),4 pcs)
(M4×10, 2 pcs)
(Plastic washer (10×4),2 pcs)
(M4×12, 3 pcs)

  • The plastic washers are supplied with the screws when the product is shipped. Check that the plastic washers have not come loose.
    Precaution

    • Always attach the plastic washers.
      If the washers are not attached, water may leak through, making it difficult to remove the screws.

    • Take care that the main power switch is not turned on when installing the cover. If the foot control is accidentally turned on, the seat will start moving, and may cause accidents or malfunctions to the main body.

TAKARA BELMONT Yume Noble Washing System - Takara 1 Tips
If you fix the plate while pressing the position of the arrow with the finger, the gap between the covers can be made small. (3)Attach the clips to base cover L and R in four locations. (clip, 4 pcs (2 each at the front and rear)

  • Take note of the clip orientation when attaching them.TAKARA BELMONT Yume Noble Washing System - Base Cover Install base plate F to base plate H
    Attach base plate F to base plate H with screws. (Urea screws M6 × 12, 2 pcs, with rubber packing) *The rubber packing is supplied with the screws when the product is
    shipped. Check that the rubber packing has not come loose.
    Precaution
    Always attach the rubber packing to the Urea screws.
    Water may seek into the base plate from the screw attachment holes, causing malfunctions to the main body.
    Precaution
    Attach the Urea screw by hand without using any tools. Using tools may cause damage to the plastic section.TAKARA BELMONT Yume Noble Washing System -
Base Cover 1 Check operation (1) (after assembling the seat)
    Precaution
    • Check once again that the transportation bolt has been removed.
    • Check beforehand that there are no people or objects surrounding the seat.

    1. Turn the main power switch on. Press the right side ( symbol ) of the main power switch.

    2. Press the foot control and check operation of the seat. For operating procedures, see the separate “YUME ESPOIR/YUME SUITE/YUME NOBLE Instruction Manual”.

    3.  Once operation has been confirmed, check the attachment condition of the following items.

      Is there a large step or gap in the join between the covers? Is there a large gap between the cover or base plate and floor? Is the cover or base plate vibrating or resonating while operating?
    4. Hold down (pressing for one second or longer will make the unit “beep”) the foot control Seat lowering switch to raise the seat back frame.

    5.  Turn the main power switch off.

TAKARA BELMONT Yume Noble Washing System - Base Cover
2If there are problems present, check the screws used to attach the parts and reattach when necessary.

Attach backrest and seat

  1. Attach backrest and seat
    (1) Insert the backrest into the supporting column in vertical state, align with the back frame and attach with screws through the attachment holes (middle). (M6 × 15, 4 pcs)
    (2) Turn the main power switch on.
    (3) Hold down (pressing for one second or longer will make the unit “beep”) the Seat lifiting switch of foot cpntrol to recline the backrest and bring the seat to its highest position.
    (4) Check the distance between the end of the seat back and basin. See “Adjusting the distance between the end of the backrest and basin” below for more nformation.
    (5) Turn the main power switch off.

TAKARA BELMONT Yume Noble Washing System - Backrest
SeatAdjusting the distance between the end of the backrest and basin
Check the following with the reclined down.

  1. Does the end of the backrest hit the basin?
  2.  Is there a large gap between the end of the backrest and basin?

Is there a variation in the gap with each main body?
(Install the end of the backrest and basin so that the distance between  them is approximately 10 to 20 mm.) Use the following procedure if the distance between the end of the backrest and basin requires adjustment.

  • To bring the end of the backrest and basin and closer together: use the attachment hole (top)
  • To separate the end of the backrest and basin: use the attachment hole (bottom)

Attach the seat

(1) Attach the seat and seat body with screws. (M8 × 30, 4 pcs) * For models with a fixed legrest, there will be four screws remaining of the seat attachment screw set (M8 × 30).![TAKARA BELMONT Yume Noble Washing System - Backrest Seat 2](https://manuals.plus/wp-content/uploads/2024/01/TAKARA-BELMONT-Yume-Noble-Washing-System-Backrest-Seat-2.jpg)
  1. Attach the seat and seat body with screws. (M8×30, 8 pcs)
    Precaution
    When attaching the seat, take care that the apron does not become trapped.
    Hold down (pressing for one second or longer will make the unit “beep”) the foot control Seat lowering switch to lower the seat back to its lowest position.TAKARA BELMONT Yume Noble Washing System - Backrest Seat
3![TAKARA BELMONT Yume Noble Washing System

< SUITE>

  1. Attach the seat and seat body with screws. (M8×30, 8 pcs)

  2. Hold down (pressing for one second or longer will make the unit “beep”) the foot control Seat lowering switch to lower the seat back to its lowest position.TAKARA BELMONT Yume Noble Washing System - Hold DownTAKARA BELMONT Yume Noble Washing System - Hold Down 1

  3. Attach the apron
    Attach the seat apron to the backrest using screws. (M4 × 12, 2 pcs)

  4. Attach the backrest cover
    Attach the backrest cover so that it is aligned with the backrest.
    (M4 × 30, 8 pcs)TAKARA BELMONT Yume Noble Washing System - Hold Down
2

Precaution
Take care not to hit or trap other parts when installing the apron or cover. Doing so may damage the parts and cause malfunctions.
Check operation (2) (after attaching the backrest and seat)
Precaution
Check beforehand that there are no people or objects surrounding the seat.

  1. Turn the main power switch on. Press the right side ( symbol) of the main power switch.
  2. Press the foot control and check operation of the seat. For operating procedures, see the separate “YUME ESPOIR/ YUME SUITE/YUME NOBLE Instruction Manual”.
  3. Once operation has been confirmed, check the attachment condition of the following items.

TAKARA BELMONT Yume Noble Washing System - Hold Down 3
With the seat back down,

  1. Does the end of the seat back hit the basin?
  2.  Is there a large gap between the end of the seat back and basin?

Is there a variation in the gap with each main body?
Is there a variation in the gap with each main body?
Foot control Main power switch Apron Legrest Seat lifting switch M4 × 12 Backrest
→ Use the “Adjusting the distance between the basin and seat back” on
P 24 if the distance between the end of the seat back and basin requires adjustment.
Is the cover vibrating or resonating while operating?
→ If there are problems present, check the screws used to attach the parts and reattach when necessary.
Does the seat back no toward the rear when it is in its most upright position?
→ If the seat back moves toward the rear there may be a mechanical fault and repairs may be required, so contact your closest dealer or Takara Belmont directly.

After installation

Remove the air mat attached to the basin and protective tape applied to the main body cover.
Precaution
Always conduct the following inspections to prevent accidents during use.
Inspection items (basin body)

  1. Are there any screws that have not been attached?
  2. Is there any rattling? Check the attachment areas again if there is any rattling.
  3. Are there any cracks or dirt on the basin?
  4. Is there any damage or blemishes on the exterior parts?
  5.  Is water leaking onto the floor surface?

Inspection items (seat body)

  1. Are there any screws that have not been attached?
  2. Is the seat body operating correctly?
  3. With the seat back down, does the end of the seat back hit the basin?
  4.  Do the seat back and seat hit each other? Are the seat back and seat bent?
  5.  Are there any blemishes such as damage on the exterior parts

Attach neck cushion

Attach neck cushion

  1. Set the neck cushion to the attachment tool in the direction as shown in the image.TAKARA BELMONT Yume Noble Washing System - Hold Down 4
  2. Attach the seat side snap buttons of the neck cushion to the fastening pins on the attachment tool.
  • Take care not to lose the fastening pins. 3. Adjust the shape of the neck cushion to suit the attachment tool, and attach the basin side snap buttons of the neck cushion to the fastening pins.

Attach head pillow
Insert the head pillow in the direction as shown in the image.TAKARA
BELMONT Yume Noble Washing System - Hold Down 6

Attach hair catchar and drain cap

Attach hair catchar and drain cap
Put the hair catcher into the drain port and place the drain cap on the top as shown in the image.

Main body attachment diagram

The floor surface is tiled, cracks may occur when fastening the bolts during installation of the shampoo unit.
In this case, use materials such as plywood or mortar for the attachment area.

  1. Use the outline of the basin base and seat base, and remove the tiles or glass on the inside.
    Take care when removing these parts. The area that tiles or glass were removed from may be visible.

  2.  Apply concrete panel to the inside area that tiles or glass were removed from. Ensure that the concrete panel sits higher than the surrounding tiles or glass (within 2 to 3 mm).

Location of the position to connect the main body power plug and power outlet

  • Location of the position to connect the main body power plug and power outlet.
  • Floor installation surface.
  • Area for power cable installation position.

Product dimensions (maximum)

  • Distance from drain center to seat end is
    【ESPOIR】 For fixed legrest 1585 mm (maximum distance with seat back in its upright position)
    For movable legrest 1520 mm (maximum distance with seat back down)
    【SUITE】【NOBLE】 1585 mm (maximum distance with seat back down)
    Reference installation dimensions

  •  Distance from drain center to wall surface is
    【ESPOIR】 For fixed legrest 2020 mm (including legroom of 435 mm) For movable legrest 1970 mm (including legroom of 450 mm)
    【SUITE】【NOBLE】 2020 mm (including legroom of 435 mm) * Ensure that there is ample space around the footing for extremely tall customers.
    Product dimensions

  • Distance from drain center to basin rear end is 300 mm

  • Distance from drain center to hose cover rear end 373 m
    Fecommended installation dimensions

  • Distance from drain center to wall surface or furniture is 930 mm or more
    (including workspace of 630 mm)

  • Workspace: Distance from basin rear end to wall surface or furniture (assuming shampoo and treatmentsperformed from behind the basin while sitting on a TAKARA BELMONT Yume Noble Washing System - Hold Down 8

COUNTRY REGISTERED PLACE OF BUSINESS & ADDRESS
GBR Importer in UK TAKARA BELMONT(U.K.)LTD.

BELMONT HOUSE, ONE ST.ANDREWS WAY, BOW LONDON E3 3PA, ENGLAND
DEU| Importeur in Deutschland| TAKARA COMPANY EUROPE GmbH BERNER STRASSE 18, 60437 FRANKFURT/M,GERMANY
FRA| Importateur en France| TAKARA COMPAGNIE PARIS S.A.R.L. 56 rue des Hautes Pâtures 92009 NANTERRE Cedex France
ITA| Importatore in Italia| TAKARA BELMONT ITALY S.R.L. Via Marino Mazzacurati No.4/1, 42019 Scandiano RE, Italy

➢ Declaration of Conformity
We hereby declare that the product listed below complies with the essential requirements of the EMC (electromagnetic compatibility) Directive : 2014/30/EU,Low Voltage Directive : 2014/35/EU, Machinery Directive : 2006/42/EC and RoHS Directive : 2011/65/EU based on category 11 of Annex I. Product : BEAUTY SHAMPOO CHAIR
Model : YUME ESPOIR/YUME SUITE/YUME NOBLE
The product has been designed and manufactured in accordance with the European standards as the listed in the Declaration of Conformity.
DECLARATION OF CONFORMITY
We declare under sole responsibility that the device that is covered by the present declaration is in conformity with the following regulations and, if applicable, with any other relevant UK legislation that provides for the issuing of an UK declaration of conformity.
Product : BEAUTY SHAMPOO CHAIR
Model : YUME ESPOIR/YUME SUITE/YUME NOBLE
Regulations this product conforms to:
The Electrical Equipment (Safety) Regulations 2016, S.I. 2016/110
The Electromagnetic Compatibility Regulations 2016, S.I. 2016/1091
The Supply of Machinery (Safety) Regulations 2008, S.I. 2008/1597
The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment
Regulations 2012, S.I. 2012/3032 based on category 11 of PART 1, SCHEDULE I

EU Authoised representative
TAKARA COMPANY EUROPE GmbH
Berner Strasse 18, 60437
Frankfurt am Main, Germany
UK Authorised representative
TAKARA BELMONT(U.K.)LTD.
BELMONT HOUSE, ONE ST.ANDREWS WAY, BOW
LONDON E3 3PA, ENGLAND
TAKARA BELMONT CORPORATION
2-1-1, Higashishinsaibashi,Chuo-ku,Osaka, 542-0083, Japan