PRISM MI13 Wi-Fi Dual Radio In Wall AP User Guide

June 16, 2024
PRISM

PRISM MI13 Wi-Fi Dual Radio In Wall AP

Specifications

  • Model: MI13
  • Wi-Fi Standard: Wi-Fi 6
  • Wireless Technology: Dual-Radio
  • Frequency Range:
    • 2.4 GHz: 2412-2472 MHz, Maximum E.I.R.P: 18.09 dBm
    • 5 GHz:
    • 5180-5240 MHz, Maximum E.I.R.P: 22.03 dBm
    • 5260-5320 MHz, Maximum E.I.R.P: 22.08 dBm
    • 5500-5700 MHz, Maximum E.I.R.P: 24.93 dBm
    • 5745-5825 MHz, Maximum E.I.R.P: 13.67 dBm

Your AP

No. ****

1| WAN: For PoE Power IN/data transfer
2| Reset
3| LAN1: For PoE Power OUT/data transfer
4| LAN2~LAN4: Data transfer
5| LED
LED Status| ****
---|---
Flash Green / Off every second| The device is booting up
Flash Green / Blue every second| The device has lost network connectivity
Steady Green| The device is operated in standalong mode
Flash Blue / Off every second| The device is connecting to PrismX
Steady Blue| The device is operated in cloud mode
Flash Red / Off every second| The device status abnormal
Flash Green / Red every second| FW upgrading

Installing the Wall Mount

  1. Installing the Wall Mount
  2. Connect RJ45 cable (with PoE) to the WAN port of your AP
  3. Secure your AP to the mounting bracket ****

Accessing the AP’s Settings Menu via WAN (RJ-45)
FACTORY DEFAULT OF MI13 IS AP MODE. MAKE SURE FOLLOWING THE INSTRUCTION BELOW WITH PHYSICAL RJ45 CABLE TO ACCESS YOUR MI13

  1. Configure your PC’s IP setting to static and then set the IP address to any address from 192.168.19.2 to 192.168.19.250.
  2. Connect your PC’s network port to the WAN port on the AP.
  3. Enter the IP address 192.168.19.1 in your browser.
  4. In the PRISM login screen use the following login:
    • Username: prism
    • Password: prism

FCC

Regulatory Statements
IC Warning: This device complies with Industry Canada license-exempt RSS standard(s).

Operation is subject to the following two conditions:

  1. this device may not cause interference,
  2. this device must accept any interference, including interference that may cause undesired operation of the device.

Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotopically radiated power (e.i.r.p.) is not more than that necessary for successful communication.

STATEMENT OF RADIATION EXPOSURE:
This equipment complies with the limits of exposure to IC radiation established for an uncontrolled environment. This equipment must be installed and used with a minimum of 20cm distance between the radiation source and your body.

The device for operation in the band 5150–5250 MHz is only for indoor use to reduce the potential for harmful interference to co-channel mobile satellite systems.

FCC statement
This equipment has been tested and found to comply with the limits for a Class B digital device, under Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used under the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

This device complies with Part 15 of the FCC Rules.

Operation is subject to the following two conditions:

  1. this device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

FCC Radiation Exposure Statement
The equipment complies with FCC Radiation exposure limits set forth for uncontrolled environments. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body.

RED 2014/53/EU
Declaration of Conformity Hereby, Suzhou WINTECH Electronics Technology Co., Ltd. declares that this Wi-Fi 6 AX1800 Dual-Radio In-Wall AP product complies with essential requirements and other relevant provisions of Directive 2014/53/EU.

  • 2.4GWi-Fi Frequency range: 2412-2472MHz, Maximum E.I.R.P: 18.09dBm
  • 5G Wi-Fi Frequency range: 5180-5240MHz, Maximum E.I.R.P: 22.03dBm
    • 5260-5320MHz, Maximum E.I.R.P: 22.08dBm
    • 5500-5700MHz, Maximum E.I.R.P: 24.93dBm
    • 5745-5825MHz, Maximum E.I.R.P: 13.67dBm

The device complies with RF specifications when the device is used at 20cm from your body.
The device supports Wlan 5G(5150-5250MHz), and Wlan 5G(5180-5240MHz) is only used indoors.

QR SCAN

Wi-Fi 6 AX1800 Dual-Radio In-Wall AP
Model: MI13

FAQ

  • 1. How do I reset my MI13 to factory defaults?
  • To reset your MI13 to factory defaults, locate the reset button on the device and press and hold it for at least 10 seconds. The device will reboot and all settings will be restored to their default values.
  • 2. What is the maximum distance between the radiation source and my body?
  • The equipment should be installed and used with a minimum distance of 20cm between the radiation source and your body to comply with radiation exposure limits.
  • 3. How can I contact customer support?
  • You can contact our worldwide enterprise support team at +886-3-6006899 or email us at sales@prismwifi.com.
  • 4. Is the MI13 compliant with regulatory standards?
  • Yes, the MI13 complies with the essential requirements and relevant provisions of Directive 2014/53/EU. It also complies with IC Warning, CAN ICES-3 (B)/NMB-3(B), and FCC Radiation exposure limits.

Contact Us