LK-HCU 3-22 HP Air Cooled Condensing Units User Manual
- June 16, 2024
- LK-HCU
Table of Contents
- 3-22 HP Air Cooled Condensing Units
- Product Usage Instructions
- FAQs
- FEATURES & BENEFITS
- ELECTRICAL OPTIONS
- 3-22 HP AIR COOLED CONDENSING UNITS
- Capacity BTUH @ 100°F Ambient by SST
- ELECTRICAL DATA
- DIMENSIONAL DRAWINGS
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
3-22 HP Air Cooled Condensing Units
Specifications
- Product Name: LK-HCU
- Release Date: February 2023
- Replaces: March 2022
- HP Range: 3 – 22
- Cooling Method: Air-Cooled
- Condensing Units: Yes
Product Usage Instructions
Features & Benefits
- Enhanced grill design gives 25% to 40% increase in free-air area
- Electrical box located out of air stream
- Vertical receiver needs less refrigerant for liquid seal
- Base valve and high & low pressure taps on outside of unit for faster access
- Removable grill for access to all serviceable parts
- Improved access to fan motors & components
- Lighter, one-piece top
- Easy-to-view sight glass location
- Better access to components for easier repair
- Compact design allows for better jobsite placement & installation
- Dual isolation valves on receiver
- Floating TubeTM coil design eliminates tube-sheet leaks
- Pre-bent tubing reduces mechanical joints
- State-of-the-art factory leak-detection ensures highest quality
- Separate subcooling circuit in condenser for added capacity and vapor free liquid
- Spring mounted compressors (DiscusTM and Bitzer Semi-Hermetic compressors only) with suction and discharge eliminators and electronic oil failure switch (DiscusTM compressors only)
- Floating TubeTM Coil design to eliminate tube sheet leaks
- Painted steel cabinet for superior strength and corrosion resistance
- Fixed high and low pressure cutouts for added safety
Nomenclature
The product is identified as LK-HCU.
Preferred Option Packages & Standard Features
Detailed information on preferred option packages and standard features can be found in the product manual.
Electrical & Mechanical Options
Details regarding electrical and mechanical options are provided in the product manual.
Scroll Compressor Models
Performance data for different temperature ranges using scroll compressor models can be found in the product manual.
Medium Temperature (R-404A/R-507A)
Performance data for medium temperature range using R-404A/R-507A refrigerant is provided in the product manual.
Medium Temperature (R-448A/R-449A)
Performance data for medium temperature range using R-448A/R-449A refrigerant is provided in the product manual.
Medium Temperature (R-407A/R-407F)
Performance data for medium temperature range using R-407A/R-407F refrigerant is provided in the product manual.
Medium Temperature (R-407C)
Performance data for medium temperature range using R-407C refrigerant is provided in the product manual.
Low Temperature (R-404A/R-507A)
Performance data for low temperature range using R-404A/R-507A refrigerant is provided in the product manual.
Low Temperature (R-448A/R-449A)
Performance data for low temperature range using R-448A/R-449A refrigerant is provided in the product manual.
Low Temperature (R-407A/R-407F)
Performance data for low temperature range using R-407A/R-407F refrigerant is provided in the product manual.
Low Temperature (R-407C)
Performance data for low temperature range using R-407C refrigerant is provided in the product manual.
Unit Specifications
Detailed unit specifications can be found in the product manual.
Electrical Data
Detailed electrical data can be found in the product manual.
DiscusTM Compressor Models
Performance data for different temperature ranges using DiscusTM compressor models can be found in the product manual.
Semi-Hermetic Compressor Models
Performance data for different temperature ranges using Semi-Hermetic compressor models can be found in the product manual.
Replacement Parts
Information on replacement parts is provided in the product manual.
Dimensional Diagrams
Dimensional diagrams for the product can be found in the product manual.
FAQs
Q: What is the release date of the product?
A: The product is scheduled to be released in February 2023.
Q: What are the cooling methods available for the product?
A: The product utilizes air-cooled condensing units.
Q: Are there different HP ranges available?
A: Yes, the product is available in HP ranges from 3 to 22.
Q: What refrigerants are compatible with the product?
A: The product is compatible with various refrigerants including R-404A, R-507A, R-448A, R-449A, R-407A, R-407F, and R-407C.
LK-HCU | FEBRUARY 2023 Replaces March 2022
3 – 22 HP AIR-COOLED CONDENSING UNITS
Technical Guide
Now including DOE compliant models
FEATURES & BENEFITS
BETTER PERFORMANCE Enhanced grill design gives 25% to 40% increase in
free-air area Electrical box located out of air stream Vertical receiver needs
less refrigerant for liquid seal
FASTER ACCESS Base valve and high & low pressure taps on
outside of unit Removable grill for access to all serviceable parts Improved
access to fan motors & components Lighter, one-piece top Easy-to-view sight
glass location
EASIER SERVICE Better access to components for easier repair Compact design
allows for better jobsite placement &
installation Dual isolation valves on receiver
GREATER RELIABILITY Floating TubeTM coil design eliminates tube-sheet leaks
Pre-bent tubing reduces mechanical joints State-of-the-art factory leak-
detection ensures
highest quality
OUTSTANDING FEATURES
Separate subcooling circuit
in condenser for added capacity and vapor free liquid
Spring mounted compressors (DiscusTM and Bitzer Semi-Hermetic compressors
only) with
suction and discharge
eliminators and electronic
oil failure switch (DiscusTM
compressors only)
Floating TubeTM Coil
design to eliminate tube sheet leaks
Painted steel cabinet
for superior strength and corrosion resistance
Fixed high and
adjustable low
pressure switches
ServiceMateTM diagnostic module standard on all
non-intelliGenTM / Beacon IITM
condensing units
Lifting and mounting holes on four corners
Large electrical panel to
facilitate ease of access
3
3-22 HP AIR COOLED CONDENSING UNITS
NOMENCLATURE
BRAND L = Larkin
CONDENSING UNIT STYLE H = Outdoor Horizontal N = Indoor Horizontal
TEMP RANGE M = Medium Temperature L = Low Temperature
REVISION
COMPRESSOR STYLE D = DiscusTM Z = Scroll X = Bitzer Semi-Hermetic
L C H 0030 L C A C D A PRODUCT IDENTIFIER C = Condensing Unit
HP 0030 = 3 hp 0040 = 4 hp 0041 = 4 hp 0050 = 5 hp 0051 = 5 hp 0056 = 5.5 hp 0060 = 6 hp 0061 = 6 hp 0062 = 6 hp 0065 = 6.5 hp 0070 = 7 hp 0075 = 7.5 hp 0076 = 7.5 hp
0080 = 8 hp 0086 = 8.5 hp 0090 = 9 hp 0091 = 9 hp 0100 = 10 hp 0101 = 10 hp 0120 = 12 hp 0121 = 12 hp 0130 = 13 hp 0131 = 13 hp 0141 = 14 hp 0150 = 15 hp 0220 = 22 hp
VOLTAGE C = 208-230/3/60 D = 460/3/60 E = 575/3/60
COMPRESSOR MANUFACTURER C = Copeland B = Bitzer
FACTORY INSTALLED OPTION PACKAGES A#### = Preferred Option Packages C#### = A la Carte Options X#### = Custom Option Packages
FACTORY INSTALLED: PREFERRED OPTION PACKAGES
Please see Price Book or The HUB for availability
Option Code
Description (All Preferred Options include Standard Base +)
A0100
Defrost Timer Air
A0300
Defrost Timer – Contactor
A0302
Defrost Timer – Contactor Low Amps
A0303
Defrost Timer – Contactor High Amps
A0400
intelliGenTM / Beacon II
A1002
Replaceable Core Filter-Accumulator + Liquid Standard + Replaceable Core Filter Drier
STANDARD FEATURES
ServiceMateTM Diagnostic Module
Manual Pump Down Switch
Electronic Oil Failure Switch (DiscusTM Compressors Only) Fixed Head Pressure
Control Valve (C4 & C5 cabinets only) · Low temp – Revision A 100 psi · Med.
temp – Revision A 145 psi · Low temp – Revision B 145 psi Adjustable Head
Pressure Control Valve (C6 cabinet only) Spring Mounted Compressors with
Suction and Discharge Vibration Eliminators (DiscusTM and Bitzer Compressors
only)
Crank Case Heater Adjustable Low Pressure Control Fixed High Pressure Control Liquid Line Sight Glass Permanent Liquid Line Filter Outdoor Painted Cabinet Floating TubeTM Design
4
ELECTRICAL OPTIONS
Smart Defrost KitTM (SDK) Crankcase Heater on Indoor Units Fan cycling Defrost
Timer for Air Defrost Defrost Timer and Contactor for Electric Defrost (C6
cabinet includes evaporator sub fusing as standard in kit) intelliGenTM/Beacon
IITM Kits (see intelliGenTM/Beacon IITM section for details) Electric Defrost
Fusing (includes evaporator fan fusing on C4 and C5 cabinets) Dual-Pressure
Control Adjustable High Pressure Control with Manual Reset Phase-Loss
Monitor Compressor Fusing Circuit Breaker Circuit Protection for Compressor,
Condenser Fan and Control Circuit
MECHANICAL OPTIONS
Adjustable Head Pressure Valve Head Pressure Valve on Indoor Units Mounted
Liquid Line Solenoid Valve Replaceable Core Liquid Line Filter/Drier Permanent
Suction Line Filter Replaceable Core Suction Line Filter Suction Accumulator
Oil Separator BohnguardTM Fin Protection Copper Finned Coil Oversized Receiver
Slanted Louver for Snowbelt Regions (not available with indoor unit) 12″
Extended Legs for Snowbelt Regions Hail Guards Standard receiver with low
ambient kit (heated/insulated receiver & low pressure bypass time delay relay)
NEMA contactors Compressor Unloading (one step)*
- Available on C6 cabinet only
5
3-22 HP AIR COOLED CONDENSING UNITS
PERFORMANCE DATA R-404A/R-507A
Medium Temperature Models – Scroll Compressors
Please consult AWEF table on page 17 to confirm DOE compliance per model
R-404A/R-507A
Capacity BTUH @ 90°F Ambient by SST
Model
Compressor +40°F +35°F +30°F +25°F +20°F +15°F +10°F
LC*0065M@ACZ ZB48KCE 77,170 71,490 66,240 61,130 56,270 51,710 47,250
LC*0070M@ACZ ZB58K5E 97,540 90,190 83,040 76,350 69,890 63,750 57,930
LC*0075M@ACZ ZB66K5E 110,080 102,060 94,260 86,900 79,720 72,820 66,510
LC*0086M@ACZ ZB76K5E 123,580 114,420 105,850 97,690 89,890 82,600 75,480
LC*0100M@ACZ ZB95K5E 142,810 133,070 123,590 114,100 105,300 96,760 88,420
LC*0141M@ACZ ZB114K5E 180,210 167,570 154,860 142,890 131,330 120,170 109,580
+5°F 43,000 52,330 60,360 68,760 80,420 99,210
+0°F 39,010 46,990 54,570 62,470 72,550 89,310
-10°F 31,710 36,810 43,810 50,390 57,420 70,820
R-404A/R-507A
Capacity BTUH @ 95°F Ambient by SST
Model
Compressor +40°F +35°F +30°F +25°F +20°F +15°F +10°F
LC*0065M@ACZ ZB48KCE 73,500 68,140 63,120 58,300 53,650 49,320 45,020
LC*0070M@ACZ ZB58K5E 93,370 86,310 79,680 73,150 66,890 60,920 55,260
LC*0075M@ACZ ZB66K5E 105,140 97,520 90,130 83,150 76,300 69,760 63,720
LC*0086M@ACZ ZB76K5E 118,020 109,330 101,270 93,530 86,120 79,070 72,450
LC*0100M@ACZ ZB95K5E 135,530 126,360 117,350 108,370 100,010 91,840 83,780
LC*0141M@ACZ ZB114K5E 171,520 159,570 147,440 136,120 125,040 114,370 104,240
+5°F 41,000 49,840 57,820 66,070 76,200 94,260
+0°F 37,200 44,590 52,280 60,090 68,590 84,720
-10°F 30,240 34,550 41,930 48,590 53,860 66,760
R-404A/R-507A
Capacity BTUH @ 100°F Ambient by SST
Model
Compressor +40°F +35°F +30°F +25°F +20°F +15°F +10°F
LC*0065M@ACZ ZB48KCE 69,790 64,690 59,970 55,390 50,980 46,730 42,770
LC*0070M@ACZ ZB58K5E 89,000 82,390 76,050 69,770 63,750 58,060 52,480
LC*0075M@ACZ ZB66K5E 100,090 92,920 85,930 79,310 72,760 66,630 60,770
LC*0086M@ACZ ZB76K5E 112,400 104,210 96,600 89,280 82,450 75,720 69,400
LC*0100M@ACZ ZB95K5E 128,170 119,540 110,990 102,480 94,500 86,750 79,280
LC*0141M@ACZ ZB114K5E 162,640 151,360 139,850 129,070 118,540 108,400 98,680
+5°F 38,950 47,180 55,220 63,370 71,780 89,120
+0°F 35,340 42,030 49,920 57,700 64,460 79,920
-10°F —
32,110 39,990 46,800
— —
R-404A/R-507A
Model
Compressor
LC*0065M@ACZ ZB48KCE
LC*0070M@ACZ ZB58K5E
LC*0075M@ACZ ZB66K5E
LC*0086M@ACZ ZB76K5E
LC*0100M@ACZ ZB95K5E
LC*0141M@ACZ ZB114K5E
+40°F —
80,120 89,850
— — —
Capacity BTUH @ 110°F Ambient by SST
+35°F +30°F +25°F +20°F +15°F +10°F
—
— 49,390 45,400 —
—
74,120 68,360 62,600 56,960 51,660 46,470
83,480 77,480 71,350 65,490 60,140 54,830
93,780 87,090 80,680 74,590 68,740 63,160
—
—
—
— 76,000 69,310
—
—
— 104,980 96,090 86,990
+5°F —
41,420 49,820 57,900
— 78,240
+0°F —
36,540 45,020
— — —
Notes: * H = Outdoor, N = Indoor @ C = 208-230/3/60, D = 460/3/60, E =
575/3/60
20°F Max Superheat
-10°F — — — — — —
6
PERFORMANCE DATA R-448A/R-449A
Medium Temperature Models – Scroll Compressors
Please consult AWEF table on page 17 to confirm DOE compliance per model
R-448A/R-449A
Capacity BTUH @ 90°F Ambient by SST
Model
Compressor +40°F +35°F +30°F +25°F +20°F +15°F +10°F
LC*0065M@ACZ ZB48KCE 78,750 72,150 65,840 59,920 54,250 48,990 44,090
LC*0070M@ACZ ZB58K5E 96,260 87,510 79,120 71,240 63,930 57,190 51,010
LC*0075M@ACZ ZB66K5E 108,670 99,160 89,840 81,060 72,860 65,370 58,480
LC*0086M@ACZ ZB76K5E 122,870 112,200 102,050 92,310 83,240 74,870 67,290
LC*0100M@ACZ ZB95K5E 146,390 133,550 121,290 109,740 99,090 88,870 79,190
LC*0141M@ACZ ZB114K5E 184,480 167,570 151,530 136,480 122,610 109,520 97,230
+5°F 39,590 45,450 52,340 60,470 69,950 85,630
+0°F 35,490 40,490 46,930 54,460 60,840 74,580
-10°F 28,390 32,300 38,460 44,960 43,070 53,090
R-448A/R-449A
Capacity BTUH @ 95°F Ambient by SST
Model
Compressor +40°F +35°F +30°F +25°F +20°F +15°F +10°F
LC*0065M@ACZ ZB48KCE 75,790 69,490 63,540 57,760 52,340 47,320 42,650
LC*0070M@ACZ ZB58K5E 93,110 84,710 76,690 69,140 62,120 55,640 49,680
LC*0075M@ACZ ZB66K5E 104,710 95,730 86,910 78,590 70,810 63,700 57,180
LC*0086M@ACZ ZB76K5E 118,360 108,350 98,810 89,620 81,080 73,220 66,110
LC*0100M@ACZ ZB95K5E 139,890 127,630 115,900 104,740 94,230 84,490 74,970
LC*0141M@ACZ ZB114K5E 176,950 160,710 145,280 130,740 117,260 104,440 92,310
+5°F 38,430 44,300 51,370 59,750 65,820 80,790
+0°F 34,590 39,490 46,290 54,200 56,650 69,790
-10°F 28,090 31,520 38,410
— — 48,120
R-448A/R-449A
Capacity BTUH @ 100°F Ambient by SST
Model
Compressor +40°F +35°F +30°F +25°F +20°F +15°F +10°F
LC*0065M@ACZ ZB48KCE 72,860 66,830 61,120 55,620 50,470 45,720 41,320
LC*0070M@ACZ ZB58K5E 89,530 81,720 74,080 66,900 60,200 54,030 48,320
LC*0075M@ACZ ZB66K5E 100,600 92,180 83,870 76,050 68,740 62,080 56,000
LC*0086M@ACZ ZB76K5E 113,700 104,350 95,450 86,880 78,940 71,680 65,130
LC*0100M@ACZ ZB95K5E
— 121,450 110,210 99,510 89,320 79,840 70,420
LC*0141M@ACZ ZB114K5E 169,080 153,570 138,700 124,650 111,570 99,030 87,080
+5°F 37,380 43,170 50,600 59,330 61,360 75,450
+0°F 33,830 38,560 45,900 54,360 52,280 64,520
-10°F 27,980
— — — — 42,850
R-448A/R-449A
Capacity BTUH @ 110°F Ambient by SST
Model
Compressor +40°F +35°F +30°F +25°F +20°F +15°F +10°F +5°F +0°F
LC*0065M@ACZ ZB48KCE
—
—
—
51,520 46,970 42,800 39,030 35,710
—
LC*0070M@ACZ ZB58K5E 81,970 75,100 68,310 61,900 55,940 50,490 45,400 40,830 —
LC*0075M@ACZ ZB66K5E 91,880 84,620 77,440 70,730 64,480 58,880 53,840 49,460 —
LC*0086M@ACZ ZB76K5E
—
— 88,480 81,290 74,710 68,800 63,640 59,250 —
LC*0100M@ACZ ZB95K5E
—
—
—
—
— 69,660 60,650 51,760 —
LC*0141M@ACZ ZB114K5E
—
—
—
— 99,290 87,260 75,660 64,260 —
Notes: * H = Outdoor, N = Indoor @ C = 208-230/3/60, D = 460/3/60, E =
575/3/60
20°F Max Superheat
-10°F — — — — — —
7
3-22 HP AIR COOLED CONDENSING UNITS
PERFORMANCE DATA R-407A/R-407F
Medium Temperature Models – Scroll Compressors
Please consult AWEF table on page 17 to confirm DOE compliance per model
R-407A/R-407F
Capacity BTUH @ 90°F Ambient by SST
Model
Compressor +40°F +35°F +30°F +25°F +20°F +15°F +10°F
LC*0065M@ACZ ZB48KCE 78,690 72,600 66,610 60,880 55,240 49,890 44,790
LC*0070M@ACZ ZB58K5E 96,810 88,720 80,910 73,690 66,900 60,630 54,560
LC*0075M@ACZ ZB66K5E 109,470 100,600 92,040 83,620 75,530 67,810 60,620
LC*0086M@ACZ ZB76K5E 125,510 115,590 105,720 96,180 86,680 77,590 68,930
LC*0100M@ACZ ZB95K5E 143,590 133,110 122,480 111,830 101,300 91,190 81,190
LC*0141M@ACZ ZB114K5E 182,540 168,040 153,710 139,770 126,400 113,490 101,240
+5°F 40,010 48,660 53,840 61,020 71,730 89,780
+0°F 35,620 42,810 47,570 53,730 62,930 79,160
-10°F 27,830 30,800 36,710 41,930 48,410 61,000
R-407A/R-407F
Capacity BTUH @ 95°F Ambient by SST
Model
Compressor +40°F +35°F +30°F +25°F +20°F +15°F +10°F
LC*0065M@ACZ ZB48KCE 75,410 69,590 63,860 58,370 52,960 47,810 42,930
LC*0070M@ACZ ZB58K5E 93,110 85,390 78,030 71,130 64,550 58,450 52,450
LC*0075M@ACZ ZB66K5E 105,220 96,680 88,430 80,280 72,510 65,170 58,200
LC*0086M@ACZ ZB76K5E 120,630 111,020 101,470 92,240 83,110 74,420 66,200
LC*0100M@ACZ ZB95K5E 136,880 126,830 116,640 106,440 96,620 86,710 77,190
LC*0141M@ACZ ZB114K5E 174,860 160,930 147,150 133,610 120,870 108,480 96,730
+5°F 38,320 46,560 51,730 58,760 68,290 85,770
+0°F 34,110 40,650 45,770 52,050 60,070 75,660
-10°F 26,670 28,320 35,580 41,540 46,830 58,630
R-407A/R-407F
Capacity BTUH @ 100°F Ambient by SST
Model
Compressor +40°F +35°F +30°F +25°F +20°F +15°F +10°F
LC*0065M@ACZ ZB48KCE 72,060 66,510 61,190 55,800 50,630 45,700 41,030
LC*0070M@ACZ ZB58K5E 89,230 82,020 75,020 68,390 62,030 56,080 50,130
LC*0075M@ACZ ZB66K5E 100,840 92,810 84,710 76,900 69,440 62,420 55,780
LC*0086M@ACZ ZB76K5E 115,630 106,360 97,180 88,310 79,570 71,350 63,640
LC*0100M@ACZ ZB95K5E
— 120,400 110,660 100,950 91,580 82,200 73,230
LC*0141M@ACZ ZB114K5E 166,980 153,690 140,470 127,760 115,250 103,390 92,180
+5°F 36,620 44,250 49,640 56,720 64,920 81,770
+0°F 32,580 38,260 44,020 50,610 57,350 72,220
-10°F 25,480 25,640 34,550 41,650 45,550 56,380
R-407A/R-407F
Model
Compressor
LC*0065M@ACZ ZB48KCE
LC*0070M@ACZ ZB58K5E
LC*0075M@ACZ ZB66K5E
LC*0086M@ACZ ZB76K5E
LC*0100M@ACZ ZB95K5E
LC*0141M@ACZ ZB114K5E
+40°F —
81,530 91,810
— — —
Capacity BTUH @ 110°F Ambient by SST
+35°F +30°F +25°F +20°F +15°F +10°F
—
—
— 45,840 41,380 37,160
74,890 68,520 62,430 56,530 50,750 44,940
84,480 77,100 69,990 63,180 56,940 51,070
— 88,760 80,600 72,850 65,690 59,170
—
—
—
—
— 65,520
—
—
—
— 93,120 83,090
+5°F 33,180 39,030 45,610 53,520 58,490 73,810
+0°F 29,560 32,900 40,770 48,860 52,490 65,600
-10°F 23,170 19,760 32,920 43,450 44,140 52,460
Notes: * H = Outdoor, N = Indoor @ C = 208-230/3/60, D = 460/3/60, E =
575/3/60
20°F Max Superheat
8
PERFORMANCE DATA R-407C
Medium Temperature Models – Scroll Compressors
Please consult AWEF table on page 17 to confirm DOE compliance per model
R-407C
Capacity BTUH @ 90°F Ambient by SST
Model
Compressor +40°F +35°F +30°F +25°F +20°F +15°F +10°F
LC*0065M@ACZ ZB48KCE 71,130 65,160 59,300 53,610 48,150 42,820 —
LC*0070M@ACZ ZB58K5E 90,610 82,250 74,430 67,060 60,330 53,930 48,010
LC*0075M@ACZ ZB66K5E 102,960 93,420 84,540 76,210 68,450 61,330 54,690
LC*0086M@ACZ ZB76K5E 118,020 107,560 97,670 88,460 79,780 71,780 64,380
LC*0100M@ACZ ZB95K5E 138,290 125,810 113,930 102,750 92,270 82,520 73,440
LC*0141M@ACZ ZB114K5E 168,890 153,790 139,360 125,770 113,200 101,460 —
+5°F —
42,400 48,420 57,560 64,780
—
+0°F —
37,070 42,500 51,300 56,570
—
-10°F — — — — — —
R-407C Model
LC0065M@ACZ LC0070M@ACZ LC0075M@ACZ LC0086M@ACZ LC0100M@ACZ LC0141M@ACZ
Capacity BTUH @ 95°F Ambient by SST
Compressor +40°F +35°F +30°F +25°F +20°F +15°F +10°F
ZB48KCE 68,560 62,800 57,120 51,590 46,270 41,070 —
ZB58K5E 87,950 79,790 72,110 64,840 58,170 51,910 46,080
ZB66K5E 100,160 90,850 82,160 74,010 66,460 59,440 52,940
ZB76K5E 114,660 104,520 94,890 85,960 77,540 69,770 62,600
ZB95K5E 133,550 121,390 109,830 98,980 88,780 79,280 70,430
ZB114K5E 163,670 148,980 134,950 121,730 109,490 —
—
+5°F —
40,550 46,820 56,010 62,000
—
+0°F —
35,310 41,010 49,970
— —
-10°F — — — — — —
R-407C
Capacity BTUH @ 100°F Ambient by SST
Model
Compressor +40°F +35°F +30°F +25°F +20°F +15°F +10°F
LC*0065M@ACZ ZB48KCE 65,940 60,350 54,860 49,560 —
—
—
LC*0070M@ACZ ZB58K5E 85,190 77,190 69,620 62,490 55,910 49,780 43,990
LC*0075M@ACZ ZB66K5E 97,290 88,190 79,710 71,740 64,360 57,490 51,130
LC*0086M@ACZ ZB76K5E 111,260 101,430 92,120 83,460 75,290 67,780 60,840
LC*0100M@ACZ ZB95K5E 128,670 116,870 105,680 95,100 85,180 75,940 67,340
LC*0141M@ACZ ZB114K5E 158,310 144,070 130,420 117,580 —
—
—
+5°F —
38,560 45,140 54,470 59,120
—
+0°F —
33,400 — — — —
-10°F — — — — — —
R-407C
Capacity BTUH @ 110°F Ambient by SST
Model
Compressor +40°F +35°F +30°F +25°F +20°F +15°F +10°F +5°F +0°F -10°F
LC*0065M@ACZ ZB48KCE
—
—
—
—
—
—
—
—
—
—
LC*0070M@ACZ ZB58K5E 79,270 71,560 64,270 57,410 50,950 44,970 39,430 —
—
—
LC*0075M@ACZ ZB66K5E 91,280 82,750 74,590 66,990 59,940 53,380 47,320 —
—
—
LC*0086M@ACZ ZB76K5E
—
— 86,540 78,440 70,810 63,820 —
—
—
—
LC*0100M@ACZ ZB95K5E
—
—
—
— 77,730 69,150 —
—
—
—
LC*0141M@ACZ ZB114K5E 147,200 133,880 —
—
—
—
—
—
—
—
Notes: * H = Outdoor, N = Indoor @ C = 208-230/3/60, D = 460/3/60, E =
575/3/60
20°F Max Superheat
9
3-22 HP AIR COOLED CONDENSING UNITS
PERFORMANCE DATA R-404A/R-507A
Low Temperature Models – Scroll Compressors
Please consult AWEF table on page 18 to confirm DOE compliance per model
R-404A/R-507A
Model
Compressor
LC*0075L@ACZ ZF25K4E
LC*0100L@BCZ ZF34K5E
LC*0130L@BCZ ZF41K5E
LC*0150L@BCZ ZF49K5E
+0°F 42,170 52,610 70,440 79,070
-5°F 38,520 48,550 64,440 72,190
Capacity BTUH @ 90°F Ambient by SST
-10°F
-15°F
-20°F
-25°F
34,960 31,610 28,460 25,560
44,450 40,530 36,780 33,240
58,730 53,360 48,150 43,250
65,690 59,530 53,680 48,300
-30°F 22,850 29,880 38,600 43,250
-35°F 20,350 26,690 34,130 38,430
-40°F 18,060 23,670 29,850 33,920
R-404A/R-507A
Model
Compressor
LC*0075L@ACZ ZF25K4E
LC*0100L@BCZ ZF34K5E
LC*0130L@BCZ ZF41K5E
LC*0150L@BCZ ZF49K5E
+0°F 40,420 49,970 67,440 75,530
-5°F 36,880 46,190 61,770 69,040
Capacity BTUH @ 95°F Ambient by SST
-10°F
-15°F
-20°F
-25°F
33,580 30,400 27,430 24,660
42,350 38,660 35,140 31,790
56,400 51,230 46,320 41,640
62,880 57,040 51,480 46,380
-30°F 22,100 28,620 37,180 41,550
-35°F 19,740 25,590 32,880 36,950
-40°F 17,580 22,730 28,740 32,650
R-404A/R-507A
Model
Compressor
LC*0075L@ACZ ZF25K4E
LC*0100L@BCZ ZF34K5E
LC*0130L@BCZ ZF41K5E
LC*0150L@BCZ ZF49K5E
+0°F 38,650
— 64,340 71,890
-5°F 35,360
— 59,000 65,770
Capacity BTUH @ 100°F Ambient by SST
-10°F
-15°F
-20°F
-25°F
32,190 29,190 26,390 23,770
—
—
33,430 30,290
53,880 49,050 44,390 39,940
59,980 54,460 49,190 44,350
-30°F 21,360 27,320 35,670 39,790
-35°F 19,140 24,460 31,550 35,430
-40°F 17,130 21,760 27,570 31,330
R-404A/R-507A
Model
Compressor
LC*0075L@ACZ ZF25K4E
LC*0100L@BCZ ZF34K5E
LC*0130L@BCZ ZF41K5E
LC*0150L@BCZ ZF49K5E
+0°F — —
57,840 —
-5°F — — 53,100 —
Capacity BTUH @ 110°F Ambient by SST
-10°F
-15°F
-20°F
-25°F
—
—
—
22,020
—
—
—
—
48,750 44,400 40,240 36,250
—
—
—
—
-30°F 19,930
— 32,400
—
-35°F 18,020
— 28,640 32,250
-40°F 16,300
— 24,980 28,570
Notes: * H = Outdoor, N = Indoor models only available as model Rev A @ C =
208-230/3/60, D = 460/3/60, E = 575/3/60
10
PERFORMANCE DATA R-448A/R-449A
Low Temperature Models – Scroll Compressors
Please consult AWEF table on page 18 to confirm DOE compliance per model
R-448A/R-449A
Model
Compressor
LC*0075L@ACZ ZF25K4E
LC*0100L@BCZ ZF34K5E
LC*0130L@BCZ
ZF41K5E
+0°F 40,360 51,380 66,930
LC*0150L@BCZ ZF49K5E 79,680
-5°F 36,240 46,450 60,210
71,820
Capacity BTUH @ 90°F Ambient by SST
-10°F
-15°F
-20°F
-25°F
32,420 28,870 25,650 22,720
41,790 37,360 33,220 29,350
53,960 48,140 42,730 37,720
64,430 57,440 50,980 44,940
-30°F 20,090 25,770 33,110
39,430
-35°F 17,770 22,410 28,820
34,370
-40°F 15,730 19,280 24,840
29,790
R-448A/R-449A
Model
Compressor
LC*0075L@ACZ ZF25K4E
LC*0100L@BCZ ZF34K5E
LC*0130L@BCZ ZF41K5E
LC*0150L@BCZ ZF49K5E
+0°F 38,980 49,560 64,930 77,100
-5°F 35,020 44,820 58,420 69,550
Capacity BTUH @ 95°F Ambient by SST
-10°F
-15°F
-20°F
-25°F
31,350 27,930 24,870 22,090
40,370 36,150 32,190 28,490
52,430 46,780 41,550 36,700
62,410 55,680 49,450 43,640
-30°F 19,610 25,040 32,240 38,320
-35°F 17,440 21,810 28,080 33,450
-40°F 15,570 18,800 24,230 29,050
R-448A/R-449A
Model
Compressor
LC*0075L@ACZ ZF25K4E
LC*0100L@BCZ ZF34K5E
LC*0130L@BCZ
ZF41K5E
LC*0150L@BCZ ZF49K5E
+0°F 37,600 47,620 62,830 74,380
-5°F 33,800 43,160 56,580 67,150
Capacity BTUH @ 100°F Ambient by SST
-10°F
-15°F
-20°F
-25°F
30,280 27,030 24,110 21,500
38,930 34,920 31,140 27,590
50,820 45,370 40,320 35,650
60,330 53,860 47,880 42,300
-30°F 19,180 24,300 31,350 37,190
-35°F 17,170 21,210 27,340 32,530
-40°F 15,470 18,340 23,630 28,310
R-448A/R-449A
Model
Compressor
LC*0075L@ACZ ZF25K4E
LC*0100L@BCZ ZF34K5E
LC*0130L@BCZ
ZF41K5E
LC*0150L@BCZ ZF49K5E
+0°F — —
58,440 —
-5°F — — 52,700 —
Capacity BTUH @ 110°F Ambient by SST
-10°F
-15°F
-20°F
-25°F
—
—
—
—
—
—
—
—
47,420 42,400 37,760 33,470
—
—
—
39,530
-30°F 18,480
— 29,510 34,860
-35°F 16,820 20,030 25,830 30,630
-40°F 15,480 17,460 22,420 26,830
Notes: * H = Outdoor, N = Indoor models only available as model Rev A @ C =
208-230/3/60, D = 460/3/60, E = 575/3/60
11
3-22 HP AIR COOLED CONDENSING UNITS
PERFORMANCE DATA R-407A/R-407F
Low Temperature Models – Scroll Compressors
Please consult AWEF table on page 18 to confirm DOE compliance per model
R-407A/R-407F
Model
Compressor
LC*0075L@ACZ ZF25K4E
LC*0100L@BCZ ZF34K5E
LC*0130L@BCZ ZF41K5E
LC*0150L@BCZ ZF49K5E
+0°F 40,540 50,640 64,250 77,330
-5°F 36,530 45,740 57,740 69,510
Capacity BTUH @ 90°F Ambient by SST
-10°F
-15°F
-20°F
-25°F
32,690 29,060 25,710 22,680
41,010 36,500 32,250 28,410
51,630 45,840 40,450 35,570
62,070 54,980 48,490 42,590
-30°F 20,000 25,010 31,270 37,470
-35°F 17,720 22,080 27,590 33,150
-40°F 15,920 19,710 24,590 29,820
R-407A/R-407F
Model
Compressor
LC*0075L@ACZ ZF25K4E
LC*0100L@BCZ ZF34K5E
LC*0130L@BCZ ZF41K5E
LC*0150L@BCZ ZF49K5E
+0°F 39,200 48,630 62,220 74,630
-5°F 35,300 43,920 55,900 67,080
Capacity BTUH @ 95°F Ambient by SST
-10°F
-15°F
-20°F
-25°F
31,590 28,070 24,840 21,900
39,370 35,040 30,950 27,260
49,940 44,340 39,100 34,370
59,860 52,990 46,680 40,990
-30°F 19,330 24,000 30,200 36,040
-35°F 17,160 21,170 26,630 31,870
-40°F 15,440 18,910 23,740 28,670
R-407A/R-407F
Model
Compressor
LC*0075L@ACZ ZF25K4E
LC*0100L@BCZ ZF34K5E
LC*0130L@BCZ ZF41K5E
LC*0150L@BCZ ZF49K5E
+0°F 37,800 46,510 60,100 71,820
-5°F 34,040 42,000 53,970 64,520
Capacity BTUH @ 100°F Ambient by SST
-10°F
-15°F
-20°F
-25°F
30,460 27,050 23,920 21,100
37,630 33,480 29,560 26,020
48,240 42,750 37,660 33,070
57,530 50,870 44,770 39,260
-30°F 18,620 22,870 29,030 34,480
-35°F 16,540 20,180 25,580 30,490
-40°F 14,900 18,020 22,780 27,420
R-407A/R-407F
Model
Compressor
LC*0075L@ACZ ZF25K4E
LC*0100L@BCZ ZF34K5E
LC*0130L@BCZ ZF41K5E
LC*0150L@BCZ ZF49K5E
+0°F — —
55,540 —
-5°F — — 49,780 —
Capacity BTUH @ 110°F Ambient by SST
-10°F
-15°F
-20°F
-25°F
—
—
—
—
—
—
—
—
44,380 39,260 34,520 30,170
—
—
—
—
-30°F 17,060
— 26,380 30,920
-35°F 15,160
— 23,140 27,210
-40°F 13,670 15,980 20,520 24,380
Notes: * H = Outdoor, N = Indoor models only available as model Rev A @ C =
208-230/3/60, D = 460/3/60, E = 575/3/60
12
PERFORMANCE DATA R-407C
Low Temperature Models – Scroll Compressors
Please consult AWEF table on page 18 to confirm DOE compliance per model
R-407C Model
LC0075L@ACZ LC0100L@BCZ LC0130L@BCZ
LC0150L@BCZ
Compressor ZF25K4E ZF34K5E ZF41K5E
+0°F 35,540 48,670 63,520
ZF49K5E 72,880
-5°F 31,870 43,870 56,880
65,250
Capacity BTUH @ 90°F Ambient by SST
-10°F
-15°F
-20°F
-25°F
28,370 25,120 22,110 19,440
39,370 35,140 31,230 27,620
50,790 45,090 39,900 35,150
57,970 51,150 44,920 39,330
-30°F 17,140 24,370 30,850
34,590
-35°F 15,250 21,370 26,960
30,790
-40°F 13,840 18,660 23,460
28,020
R-407C Model
LC0075L@ACZ LC0100L@BCZ LC0130L@BCZ LC0150L@BCZ
Compressor ZF25K4E ZF34K5E ZF41K5E ZF49K5E
+0°F 34,560 47,080 61,690 70,750
-5°F 30,970 42,470 55,240 63,280
Capacity BTUH @ 95°F Ambient by SST
-10°F
-15°F
-20°F
-25°F
27,550 24,390 21,450 18,850
38,150 34,090 30,330 26,860
49,370 43,870 38,830 34,240
56,180 49,510 43,430
0
-30°F 16,640 23,710 30,090 33,400
-35°F 14,830 20,830 26,320 29,730
-40°F 13,500 18,220 22,920 27,090
R-407C Model
LC0075L@ACZ LC0100L@BCZ LC0130L@BCZ LC0150L@BCZ
Compressor ZF25K4E ZF34K5E ZF41K5E ZF49K5E
+0°F 33,540 45,480 59,790 68,540
-5°F 30,040 41,060 53,620 61,220
Capacity BTUH @ 100°F Ambient by SST
-10°F
-15°F
-20°F
-25°F
26,720 23,620 20,770 18,250
36,910 33,020 29,390 26,060
47,920 42,610 37,740 33,310
54,280 47,770 41,800
0
-30°F 16,110 23,040 29,300 32,090
-35°F 14,380 20,280 25,660 28,550
-40°F 13,110 17,760 22,390 26,020
R-407C Model
LC0075L@ACZ LC0100L@BCZ LC0130L@BCZ LC0150L@BCZ
Compressor ZF25K4E ZF34K5E ZF41K5E ZF49K5E
+0°F 31,380
— 55,880
—
-5°F 28,050
— 50,170
—
Capacity BTUH @ 110°F Ambient by SST
-10°F
-15°F
-20°F
-25°F
24,910 21,990 19,300 16,930
—
—
—
—
44,850 39,970 35,450 31,340
—
—
—
—
-30°F 14,930
— 27,630 29,050
-35°F 13,350
— 24,260 25,720
-40°F 12,220 16,770 21,230 23,420
Notes: * H = Outdoor, N = Indoor models only available as model Rev A @ C =
208-230/3/60, D = 460/3/60, E = 575/3/60
13
3-22 HP AIR COOLED CONDENSING UNITS
UNIT SPECIFICATIONS
Medium & Low Temperature Models – Scroll Compressors
Please consult AWEF table on pages 17-18 to confirm DOE compliance per model
Model
LC0065M@ACZ LC0070M@ACZ LC0075M@ACZ LC0086M@ACZ LC0100M@ACZ LC0141M@ACZ
LC0075L@ACZ LC0100L@BCZ LC0130L@BCZ LC0150L@BCZ
Compressor
ZB48KCE ZB58K5E ZB66K5E ZB76K5E ZB95K5E ZB114K5E ZF25K4E ZF34K5E ZF41K5E
ZF49K5E
Refrigerant Line Rec. Capacity Connections (OD) @90% full (lbs) Cabineth
Dimensions (In.)
Net Wt.
Sound Data
Liquid Suction Std Opt
Depth Width Height (lbs.) dBa
1/2 1 1/8 28 52
C4 36.75 51.75 39.25 574 78
5/8 1 3/8 67 78
C5 36.75 63.75 39.25 800 80
5/8 1 3/8 67 78
C5 36.75 63.75 39.25 813 80
5/8 1 3/8 67 78
C5 36.75 63.75 39.25 818 80
5/8 1 3/8 67 78
C5 36.75 63.75 39.25 908 82
7/8 1 5/8 87 98
C6 41.75 75.125 48.75 1,235 82
1/2 1 1/8 28 52
C4 36.75 51.75 39.25 671 82
1/2 1 1/8 28 52
C4 36.75 51.75 39.25 671 82
5/8 1 3/8 67 78
C5 36.75 63.75 39.25 910 84
5/8 1 3/8 67 78
C5 36.75 63.75 39.25 891 83
Notes: * H = Outdoor, N = Indoor models only available as model Rev A @ C =
208-230/3/60, D = 460/3/60, E = 575/3/60 Estimated sound pressure values are
10 feet from the unit. For estimating sound pressure from the unit at
different distances, deduct the following from the unit values: 20 feet,
deduct 6 dBA; for 40 feet, deduct 12 dBA; for 80 feet, deduct 18 dBA. This
data is typical of “free field” conditions for horizontal air cooled
condensing units at the outlet of the discharge air. The actual sound
measurements may vary depending on the condensing unit installation. Factors
such as reflecting walls, background noise and mounting conditions may have a
significant influence on this data.
14
ELECTRICAL DATA R-404A
Medium Temperature Models – Scroll Compressors
Please consult AWEF table on page 17 to confirm DOE compliance per model
Model LC*0065MCACZ
Compressor ZB48KCE-TF5
Power 208-230/3/60
Remote Loads- Low Amps Remote Loads- High Amps
Compressor RLAc LRA
Condenser
No. FLA Fans (ea)
intelliGenTM/ Beacon II
MCA MOPD
Evap. Defrost
Fan Htrs. Amps Amps
Electric Defrost
MCA MOPD
Evap. Fan Amps
Defrost
Htrs. Amps
Electric Defrost
MCA MOPD
22.8 164.0 1 2.7 31.1 50.0 —
—
— — 15 40 (1) 50.0 60
LC*0065MDACZ ZB48KCE-TFD 460/3/60 12.2 100.0 1 1.9 20.0 25.0 —
—
—-
8 20 (1) 25.2 35
LC*0065MEACZ1,2 ZB48KCE-TFE 575/3/60 9.0 78.0 1 1.2 15.0 20.0 —
— — — 6.4 16 (1) 20.0 25
LC*0070MCACZ ZB58K5E-TFC 208-230/3/60 30.8 195.0 2 2.7 43.9 70.0 —
—
— — 20 48 (1) 63.9 90
LC*0070MDACZ ZB58K5E-TFD 460/3/60 16.0 95.0 2 1.9 23.8 35.0 —
—
— — 10 25 (1) 33.8 45
LC*0070MEACZ1 ZB58K5E-TFE 575/3/60 12.2 80.0 2 1.2 20.0 25.0 —
— —-
8 20 (1) 25.6 35
LC*0075MCACZ ZB66K5E-TFC 208-230/3/60 35.3 225.0 2 2.7 49.5 80.0 —
—
— — 20 48 (1) 69.5 100
LC*0075MDACZ ZB66K5E-TFD 460/3/60 15.4 114.0 2 1.9 23.0 35.0 —
—
— — 10 25 (1) 33.0 45
LC*0075MEACZ1 ZB66K5E-TFE 575/3/60 12.8 80.0 2 1.2 20.0 30.0 —
— —-
8 20 (1) 26.4 35
LC*0086MCACZ ZB76K5E-TFC 208-230/3/60 38.6 239.0 2 2.7 53.6 90.0 —
—
— — 20 70 (2) 87.5 110
LC*0086MDACZ ZB76K5E-TFD 460/3/60 18.6 125.0 2 1.9 27.0 45.0 —
—
—-
13 35 (1) 43.8 50
LC*0086MEACZ1 ZB76K5E-TFE 575/3/60 13.1 80.0 2 1.2 20.0 30.0 —
— — — 10.4 28 (1) 35.0 40
LC*0100MCACZ ZB95K5E-TWC 208-230/3/60 47.4 298.0 2 2.7 64.7 110.0 —
—
— — 20 70 (2) 87.5 125
LC*0100MDACZ ZB95K5E-TFD 460/3/60 21.8 150.0 2 1.9 31.0 50.0 —
—
—-
13 35 (1) 44.0 60
LC*0100MEACZ1 ZB95K5E-TFE 575/3/60 18.7 123.0 2 1.2 25.7 40.0 —
— — — 10.4 28 (1) 36.1 50
LC*0141MCACZ3 ZB114K5E-TWC 208-230/3/60 56.5 321.0 2 4.4 79.5 125.0 15 70(2) 94.5 150 20 80 (2) 100 150
LC*0141MDACZ3 ZB114K5E-TFD 460/3/60 24.4 179.0 2 2.2 34.8 50.0 15 40(1) 50.0 70 15 60 (2) 75.0 80
LC*0141MEACZ1 ZB114K5E-TWE 575/3/60 20.1 132.0 2 1.8 28.8 45.0 12 32(1) 40.8 60 12 48 (1) 60.0 60
Notes: * H = Outdoor, N = Indoor Per UL and NEC, RLA values have been
calculated by dividing the Maximum Continuous Current (MCC) by 1.56.
Unless otherwise noted, model is available for 50 Hz. Consult factory for
details. = Number of defrost heater contactors in parentheses 1 R407F not
available in 575/3/60. 2 R407C not available in 575/3/60. 3 R407C not
available in 208-230/3/60 or 460/3/60.
15
3-22 HP AIR COOLED CONDENSING UNITS
ELECTRICAL DATA R-404A
Low Temperature Models – Scroll Compressors
Please consult AWEF table on page 18 to confirm DOE compliance per model
Model LC*0075LCACZ
Compressor
Power
Compressor Condenser
RLAc
LRA
No. FLA Fans (ea)
ZF25K4E-TF5 208-230/3/60 24.0 224.0 1 2.7
intelliGenTM/ Beacon II
MCA MOPD
32.7 50.0
Remote Loads- Low Amps
Evap. Fan Amps
Defrost Htrs. Amps
Electric Defrost
MCA MOPD
—
— —-
Remote Loads- High Amps
Evap. Fan Amps
Defrost
Htrs. Amps
Electric Defrost
MCA MOPD
20 60 (2) 75.0 80
LC*0075LDACZ ZF25K4E-TFD 460/3/60 10.6 99.0 1 1.9 20.0 25.0 —
— —-
10 30 (1) 37.5 40
LC*0075LEACZ ZF25K4E-TFE 575/3/60 8.1 82.4 1 1.2 15.0 15.0 —
— —-
8 24 (1) 30.0 30
LC*0100LCBCZ3 ZF34K5E-TFC 208-230/3/60 33.3 239.0 1 2.7 44.4 70.0 —
—
— — 20 60 (2) 75.0 90
LC*0100LDBCZ ZF34K5E-TFD 460/3/60 16.0 100.0 1 1.9 21.9 35.0 —
— —-
10 30 (1) 37.5 45
LC*0100LEBCZ1 ZF34K5E-TFE 575/3/60 12.8 100.0 1 1.2 20.0 30.0 —
— —-
8 24 (1) 30.0 35
LC*0130LCBCZ ZF41K5E-TFC 208-230/3/60 37.8 248.0 2 2.7 52.7 90.0 —
— — — 20 70 (2) 87.5 110
LC*0130LDBCZ ZF41K5E-TFD 460/3/60 17.3 125.0 2 1.9 25.4 40.0 —
— —-
13 35 (1) 43.8 50
LC*0130LEBCZ ZF41K5E-TFE 575/3/60 14.0 100.0 2 1.2 20.0 30.0 —
— — — 10.4 28 (1) 35.0 40
LC*0150LCBCZ1 ZF49K5E-TFC 208-230/3/60 45.5 338.7 2 2.7 62.3 100.0 —
—
— — 20 70 (2) 87.5 125
LC*0150LDBCZ ZF49K5E-TFD 460/3/60 18.1 139.0 2 1.9 26.5 40.0 —
— —-
13 35 (1) 43.8 50
LC*0150LEBCZ1 ZF49K5E-TFE 575/3/60 16.3 123.0 2 1.2 22.8 35.0 —
— — — 10.4 28 (1) 35.0 45
Notes: * H = Outdoor, N = Indoor models only available as model Rev A Per UL
and NEC, RLA values have been calculated by dividing the Maximum Continuous
Current (MCC) by 1.56. Unless otherwise noted, model is available for 50 Hz.
Consult factory for details. = Number of defrost heater contactors in
parentheses 1 R407F not available in 575/3/60. 2 R407C not available in
575/3/60. 3 R407C not available in 208-230/3/60 or 460/3/60.
16
AWEF DATA MEDIUM TEMPERATURE
Scroll Compressor Models – Indoor/Outdoor
If model has a numerical value in the table below, the following statement
applies: This refrigeration system is designed and certified for use in walk-
in cooler applications
Model
LC0065MCACZ LC0065MDACZ LC0065MEACZ LC0070MCACZ LC0070MDACZ LC0070MEACZ
LC0075MCACZ LC0075MDACZ LC0075MEACZ LC0086MCACZ LC0086MDACZ LC0086MEACZ
LC0100MCACZ LC0100MDACZ LC0100MEACZ LC0141MCACZ LC0141MDACZ LC0141MEACZ
R-404A/ R-507A
— — — 5.61 5.61 5.61 5.61 5.61 5.61 — — — — — — — — —
Indoor
R-448A R-449A R-407A R-407C R-407F
5.61 5.61 5.61
X
5.61
5.61 5.61 5.61
X
5.61
5.61 5.61 5.61
X
5.61
5.61 5.61 —
X
5.61
5.61 5.61 —
X
5.61
5.61 5.61 —
X
5.61
5.61 5.61 5.61
X
5.61
5.61 5.61 5.61
X
5.61
5.61 5.61 5.61
X
5.61
5.61 5.61 — 5.61 5.61
5.61 5.61 — 5.61 5.61
5.61 5.61 — 5.61 5.61
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
5.61
—
—
—
—
5.61
—
—
—
—
5.61
—
R-404A/ R-507A 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60
Outdoor
R-448A R-449A R-407A R-407C R-407F
7.60 7.60 7.60
X
7.60
7.60 7.60 7.60
X
7.60
7.60 7.60 7.60
X
7.60
7.60 7.60 7.60
X
7.60
7.60 7.60 7.60
X
7.60
7.60 7.60 7.60
X
7.60
7.60 7.60 7.60
X
7.60
7.60 7.60 7.60
X
7.60
7.60 7.60 7.60
X
7.60
7.60 7.60 7.60 7.60 7.60
7.60 7.60 7.60 7.60 7.60
7.60 7.60 7.60 7.60 7.60
7.60 7.60 7.60 7.60 7.60
7.60 7.60 7.60 7.60 7.60
7.60 7.60 7.60 7.60 7.60
7.60 7.60 7.60 7.60 7.60
7.60 7.60 7.60 7.60 7.60
7.60 7.60 7.60 7.60 7.60
Notes: *H = Outdoor, N = Indoor X = model not suitable for this refrigerant —
= model is not DOE AWEF compliant If model has a numerical value in the table,
the following statement applies. “This refrigeration system is designed and
certified for use in walk-in cooler applications.”
17
3-22 HP AIR COOLED CONDENSING UNITS
AWEF DATA LOW TEMPERATURE
Scroll Compressor Models – Indoor/Outdoor
If model has a numerical value in the table below, the following statement
applies: This refrigeration system is designed and certified for use in walk-
in freezer applications
Model
LC0075LCACZ LC0075LDACZ LC0075LEACZ LC0100LCBCZ LC0100LDBCZ LC0100LEBCZ
LC0130LCBCZ LC0130LDBCZ LC0130LEBCZ LC0150LCBCZ LC0150LDBCZ LC0150LEBCZ
R-404A/ R-507A 2.40 2.40
— — — — 2.40 2.40 — — — —
Indoor
R-448A R-449A R-407A R-407C R-407F
—
—
2.40 2.40 —
—
—
2.40 2.40 —
—
—
2.40 2.40 —
—
—
— 2.40 —
—
—
— 2.40 —
—
—
—
—
—
—
—
R-404A/ R-507A
3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15
Outdoor
R-448A R-449A R-407A R-407C R-407F
3.15 3.15 3.15 3.15 3.15
3.15 3.15 3.15 3.15 3.15
3.15 —
— 3.15 3.15
3.15 3.15 —
—
3.15
3.15 3.15 —
—
3.15
3.15 3.15 —
—
3.15
3.15 3.15 — 3.15 3.15
3.15 3.15 — 3.15 3.15
3.15 3.15 —
—
3.15
3.15 3.15 —
—
3.15
3.15 3.15 —
—
3.15
3.15 3.15 —
—
3.15
Notes: *H = Outdoor, N = Indoor models only available as model Rev A X = model
not suitable for this refrigerant — = model is not DOE AWEF compliant If model
has a numerical value in the table, the following statement applies. “This
refrigeration system is designed and certified for use in walk-in freezer
applications.”
18
PERFORMANCE DATA R-404A/R-507A
Medium Temperature Models – DiscusTM Compressors
Please consult AWEF table on page 38 to confirm DOE compliance per model
R-404A/R-507A
Capacity BTUH @ 90°F Ambient by SST
Model
Compressor +40°F +35°F +30°F +25°F +20°F +15°F +10°F
LC*0050M@ACD 2DC3R53KE 60,650 55,700 50,840 46,270 41,940 37,750 33,860
LC*0051M@ACD 2DD3R63KE 69,020 64,010 58,800 53,620 48,820 44,230 39,810
LC*0075M@ACD 2DL3R78KE 81,700 75,800 70,110 64,340 58,670 53,440 48,450
LC*0076M@ACD 2DA3R89KE 101,530 93,490 86,120 78,770 71,990 65,420 59,280
LC*0080M@ACD 3DA3R10ME 118,200 109,220 100,350 92,040 84,200 76,540 69,330
LC*0100M@ACD 3DB3R12ME 133,270 124,030 114,660 105,400 96,850 88,670 80,800
LC*0120M@ACD 3DF3R15ME 153,030 142,480 132,770 123,400 113,810 104,640 95,640
LC*0150M@ACD 3DS3R17ME 184,960 171,910 159,010 146,210 134,330 122,900 111,960
+5°F 30,210 35,720 43,710 53,490 62,450 73,300 87,180 101,600
+0°F 26,820 31,930 39,290 48,110 56,100 66,170 79,020 91,680
-10°F 20,890 25,270 31,270 38,250 44,430 52,670 63,780 73,230
R-404A/R-507A
Capacity BTUH @ 95°F Ambient by SST
Model
Compressor +40°F +35°F +30°F +25°F +20°F +15°F +10°F
LC*0050M@ACD 2DC3R53KE 57,640 52,950 48,340 44,010 39,820 35,880 32,200
LC*0051M@ACD 2DD3R63KE 65,520 60,810 55,880 50,970 46,440 42,160 37,960
LC*0075M@ACD 2DL3R78KE 77,580 72,090 66,720 61,260 55,910 50,960 46,160
LC*0076M@ACD 2DA3R89KE 96,770 89,370 82,030 75,370 68,750 62,560 56,620
LC*0080M@ACD 3DA3R10ME 112,800 104,340 95,970 88,100 80,650 73,250 66,450
LC*0100M@ACD 3DB3R12ME 126,880 118,250 109,390 100,660 92,580 84,810 77,290
LC*0120M@ACD 3DF3R15ME 145,390 135,490 126,380 117,620 108,580 99,680 91,400
LC*0150M@ACD 3DS3R17ME 175,390 163,700 151,600 139,560 128,330 117,540 107,330
+5°F 28,710 34,010 41,630 51,130 59,950 70,110 83,340 97,310
+0°F 25,490 30,410 37,440 45,940 53,870 63,310 75,760 87,870
-10°F 19,840 24,120 29,840 36,430 42,630 50,400 61,010 70,230
R-404A/R-507A
Capacity BTUH @ 100°F Ambient by SST
Model
Compressor +40°F +35°F +30°F +25°F +20°F +15°F +10°F
LC*0050M@ACD 2DC3R53KE 54,630 50,080 45,860 41,820 37,840 34,030 30,530
LC*0051M@ACD 2DD3R63KE 62,020 57,590 52,940 48,330 44,050 40,000 36,070
LC*0075M@ACD 2DL3R78KE 73,540 68,370 63,320 58,200 53,140 48,450 44,000
LC*0076M@ACD 2DA3R89KE 92,020 84,780 78,110 71,780 65,490 59,560 53,920
LC*0080M@ACD 3DA3R10ME 107,440 99,240 91,590 84,160 76,970 70,260 63,650
LC*0100M@ACD 3DB3R12ME 120,520 112,460 104,130 95,910 88,260 80,940 73,910
LC*0120M@ACD 3DF3R15ME — 128,520 119,960 111,790 103,350 95,230 87,180
LC*0150M@ACD 3DS3R17ME 166,390 155,510 144,200 132,840 122,310 112,180 102,500
+5°F 27,230 32,350 39,720 48,730 57,450 67,110 79,560 93,030
+0°F 24,180 28,920 35,640 43,760 51,650 60,490 72,370 84,090
-10°F 18,790 22,990 28,410 34,600 40,840 48,120 58,310 67,200
Notes: * H = Outdoor, N = Indoor @ C = 208-230/3/60, D = 460/3/60, E =
575/3/60
19
3-22 HP AIR COOLED CONDENSING UNITS
PERFORMANCE DATA R-404A/R-507A
Medium Temperature Models – DiscusTM Compressors (cont.)
Please consult AWEF table on page 38 to confirm DOE compliance per model
R-404A/R-507A
Model
Compressor
LC*0050M@ACD 2DC3R53KE
LC*0051M@ACD 2DD3R63KE
LC*0075M@ACD 2DL3R78KE
LC*0076M@ACD 2DA3R89KE
LC*0080M@ACD 3DA3R10ME
LC*0100M@ACD 3DB3R12ME
LC*0120M@ACD 3DF3R15ME
LC*0150M@ACD 3DS3R17ME
+40°F 48,700
— — 82,170 96,740 — — —
Capacity BTUH @ 110°F Ambient by SST
+35°F +30°F +25°F +20°F +15°F +10°F
44,710 41,070 37,360 33,760 30,460 27,300
51,180 47,110 43,050 39,380 35,630 32,230
— 56,580 52,070 47,590 43,440 39,490
76,160 70,240 64,570 58,920 53,630 48,690
89,570 82,850 76,310 69,970 63,850 57,980
— 93,580 86,320 79,630 73,250 66,850
—
—
—
— 85,610 78,700
—
— 119,440 110,270 101,400 92,860
+5°F 24,350 28,960 35,650 43,930 52,460 60,700 72,060 84,410
+0°F 21,600 25,960 32,040 39,400 47,130 54,780 65,630 76,360
-10°F 16,760 20,770 25,560 30,920 37,140 43,510 52,960 61,200
Notes: * H = Outdoor, N = Indoor @ C = 208-230/3/60, D = 460/3/60, E =
575/3/60
20
PERFORMANCE DATA R-448A/R-449A
Medium Temperature Models – DiscusTM Compressors
Please consult AWEF table on page 38 to confirm DOE compliance per model
R-448A/R-449A
Model
Compressor
LC*0050M@ACD 2DC3R53KE
LC*0051M@ACD 2DD3R63KE
LC*0075M@ACD 2DL3R78KE
LC*0076M@ACD 2DA3R89KE
LC*0080M@ACD 3DA3R10ME
LC*0100M@ACD 3DB3R12ME
LC*0120M@ACD 3DF3R15ME
LC*0150M@ACD 3DS3R17ME
+40°F 60,640 68,070 83,020 100,200 119,190 135,650 152,510 187,720
Capacity BTUH @ 90°F Ambient by SST +35°F +30°F +25°F +20°F +15°F +10°F
55,060 49,740 44,780 40,050 35,750 31,770 62,120 56,390 50,940 45,890 41,110
36,750 76,130 69,580 63,380 57,540 52,140 46,930 91,440 83,200 75,180 67,550
60,630 53,980 109,550 100,040 90,900 81,920 73,340 65,310 125,280 115,000
104,920 95,110 85,840 76,820 141,100 129,740 118,290 107,400 96,880 86,760
173,320 158,990 144,930 131,260 118,240 105,600
+5°F 28,190 32,730 41,980 47,900 57,790 68,400 77,310 93,600
+0°F 24,940 29,150 37,290 42,350 50,940 60,530 68,390 82,440
-10°F 19,460 23,280 28,290 32,640 39,130 47,080 53,050 62,440
R-448A/R-449A
Capacity BTUH @ 95°F Ambient by SST
Model
Compressor +40°F +35°F +30°F +25°F +20°F +15°F +10°F +5°F +0°F -10°F
LC*0050M@ACD 2DC3R53KE 58,260 52,860 47,730 42,930 38,370 34,230 30,440 26,980 23,860 18,660
LC*0051M@ACD 2DD3R63KE 65,400 59,670 54,160 48,940 44,070 39,480 35,270 31,450 28,050 22,520
LC*0075M@ACD 2DL3R78KE 79,850 73,270 66,980 61,030 55,400 50,180 45,140 40,390 35,780 27,010
LC*0076M@ACD 2DA3R89KE 96,350 88,030 80,100 72,380 65,050 58,300 51,950 46,110 40,730 31,330
LC*0080M@ACD 3DA3R10ME 114,580 105,350 96,230 87,440 78,760 70,530 62,660 55,390 48,650 36,960
LC*0100M@ACD 3DB3R12ME 130,570 120,350 110,520 100,830 91,390 82,430 73,680 65,470 57,790 44,550
LC*0120M@ACD 3DF3R15ME 146,130 135,290 124,410 113,400 102,940 92,790 83,010 73,830 65,060 50,070
LC*0150M@ACD 3DS3R17ME 180,690 166,950 153,270 139,780 126,620 114,040 101,780 90,090 79,120 59,330
R-448A/R-449A
Capacity BTUH @ 100°F Ambient by SST
Model
Compressor +40°F +35°F +30°F +25°F +20°F +15°F +10°F
LC*0050M@ACD 2DC3R53KE 55,880 50,690 45,740 41,120 36,790 32,740 29,110
LC*0051M@ACD 2DD3R63KE 62,730 57,250 51,950 46,950 42,270 37,850 33,860
LC*0075M@ACD 2DL3R78KE 76,690 70,410 64,380 58,640 53,230 48,200 43,330
LC*0076M@ACD 2DA3R89KE 92,560 84,580 76,980 69,550 62,530 56,010 49,940
LC*0080M@ACD 3DA3R10ME 109,990 101,150 92,390 83,930 75,550 67,580 59,940
LC*0100M@ACD 3DB3R12ME 125,140 115,370 105,930 96,640 87,550 78,920 70,430
LC*0120M@ACD 3DF3R15ME — 129,470 119,030 108,440 98,390 88,600 79,130
LC*0150M@ACD 3DS3R17ME 173,650 160,610 147,520 134,620 121,990 109,820 97,920
+5°F 25,790 30,230 38,710 44,270 52,870 62,490 70,220 86,530
+0°F 22,820 27,000 34,250 39,080 46,250 54,910 61,720 75,760
-10°F 17,880 21,800 25,690 30,010 34,750 41,930
— 56,150
Notes: * H = Outdoor, N = Indoor @ C = 208-230/3/60, D = 460/3/60, E =
575/3/60
21
3-22 HP AIR COOLED CONDENSING UNITS
PERFORMANCE DATA R-448A/R-449A
Medium Temperature Models – DiscusTM Compressors (cont.)
Please consult AWEF table on page 38 to confirm DOE compliance per model
R-448A/R-449A
Model
Compressor
LC*0050M@ACD 2DC3R53KE
LC*0051M@ACD 2DD3R63KE
LC*0075M@ACD 2DL3R78KE
LC*0076M@ACD 2DA3R89KE
LC*0080M@ACD 3DA3R10ME
LC*0100M@ACD 3DB3R12ME
LC*0120M@ACD 3DF3R15ME
LC*0150M@ACD 3DS3R17ME
+40°F 51,190
— — 84,890 — — — —
Capacity BTUH @ 110°F Ambient by SST
+35°F +30°F +25°F +20°F +15°F +10°F
46,410 41,910 37,530 33,560 29,880 26,550
52,450 47,630 43,120 38,790 34,780 31,160
—
— 53,880 48,890 44,230 39,670
77,610 70,660 63,860 57,450 51,390 45,810
92,710 84,670 76,850 69,050 61,520 54,350
—
— 88,100 79,700 71,680 63,580
—
—
—
— 80,110 71,170
—
— 124,370 112,860 101,400 90,210
+5°F 23,530 27,900 35,310 40,590 47,670 56,080 62,730 79,460
+0°F 20,830 25,030 31,150 35,780 41,350 49,060 54,560 68,990
-10°F 16,460 20,530 22,980 27,350 30,140
— — —
Notes: * H = Outdoor, N = Indoor @ C = 208-230/3/60, D = 460/3/60, E =
575/3/60
22
PERFORMANCE DATA R-407A/R-407F
Medium Temperature Models – DiscusTM Compressors
Please consult AWEF table on page 38 to confirm DOE compliance per model
R-407A/R-407F
Capacity BTUH @ 90°F Ambient by SST
Model
Compressor +40°F +35°F +30°F +25°F +20°F +15°F +10°F
LC*0050M@ACD 2DC3R53KE 61,510 55,840 50,430 45,430 40,600 36,300 32,310
LC*0051M@ACD 2DD3R63KE 69,070 62,720 56,950 51,480 46,440 41,660 37,280
LC*0075M@ACD 2DL3R78KE 83,660 76,600 69,730 63,420 57,490 52,060 46,880
LC*0076M@ACD 2DA3R89KE 101,470 92,620 84,110 76,210 68,650 61,680 55,100
LC*0080M@ACD 3DA3R10ME 120,960 110,860 101,140 91,870 83,220 74,930 67,240
LC*0100M@ACD 3DB3R12ME 137,510 126,310 115,860 105,810 96,220 87,160 78,670
LC*0120M@ACD 3DF3R15ME 152,510 140,890 129,520 118,480 107,610 97,570 88,020
LC*0150M@ACD 3DS3R17ME 186,520 171,360 157,130 143,430 130,330 117,860 106,210
+5°F 28,740 33,290 42,120 49,050 59,960 70,560 79,010 95,060
+0°F 25,490 29,720 37,890 43,510 53,350 62,960 70,770 84,550
-10°F 19,970 23,830 30,440 33,610 41,340 49,410 55,990 65,380
R-407A/R-407F
Model
Compressor
LC*0050M@ACD 2DC3R53KE
LC*0051M@ACD 2DD3R63KE
LC*0075M@ACD 2DL3R78KE
LC*0076M@ACD 2DA3R89KE
LC*0080M@ACD 3DA3R10ME
LC*0100M@ACD 3DB3R12ME
LC*0120M@ACD 3DF3R15ME
LC*0150M@ACD 3DS3R17ME
+40°F 58,900 66,130 80,100 97,350 116,030 131,700 145,760 178,920
Capacity BTUH @ 95°F Ambient by SST +35°F +30°F +25°F +20°F +15°F +10°F
53,430 48,240 43,410 38,800 34,660 30,830 60,070 54,530 49,290 44,450 39,880
35,710 73,380 66,840 60,820 55,160 49,900 45,070 88,820 80,740 73,140 65,880
59,120 52,810 106,360 97,020 88,100 79,710 71,690 64,120 120,950 110,950
101,290 92,050 83,230 75,020 134,660 123,760 113,160 102,660 92,980 83,700
164,500 150,900 137,770 125,080 113,310 101,820
+5°F 27,420 31,900 40,580 47,020 57,130 66,980 74,970 90,830
+0°F 24,310 28,520 36,600 41,630 50,560 59,550 66,900 80,600
-10°F 19,080 22,970 29,660 32,030 38,590 46,050 52,360 61,600
R-407A/R-407F
Capacity BTUH @ 100°F Ambient by SST
Model
Compressor +40°F +35°F +30°F +25°F +20°F +15°F +10°F
LC*0050M@ACD 2DC3R53KE 56,300 51,060 46,060 41,440 37,020 33,040 29,430
LC*0051M@ACD 2DD3R63KE 63,120 57,430 52,140 47,130 42,500 38,130 34,140
LC*0075M@ACD 2DL3R78KE 76,570 69,990 63,960 58,240 52,870 47,940 43,310
LC*0076M@ACD 2DA3R89KE 93,360 85,100 77,490 70,070 63,030 56,590 50,510
LC*0080M@ACD 3DA3R10ME 111,100 101,840 92,870 84,250 76,170 68,280 60,980
LC*0100M@ACD 3DB3R12ME 125,840 115,880 105,960 96,670 87,750 79,230 71,210
LC*0120M@ACD 3DF3R15ME — 128,380 117,970 107,790 97,920 88,280 79,270
LC*0150M@ACD 3DS3R17ME 171,390 157,600 144,670 132,100 119,900 108,510 97,330
+5°F 26,130 30,550 39,090 44,950 54,130 63,430 70,790 86,650
+0°F 23,180 27,360 35,320 39,750 47,660 56,130 62,710 76,490
-10°F 18,240 22,170 28,930 30,440 35,710 42,580 48,410 57,680
Notes: * H = Outdoor, N = Indoor
@ C = 208-230/3/60, D = 460/3/60, E = 575/3/60
23
3-22 HP AIR COOLED CONDENSING UNITS
PERFORMANCE DATA R-407A/R-407F
Medium Temperature Models – DiscusTM Compressors (cont.)
Please consult AWEF table on page 38 to confirm DOE compliance per model
R-407A/R-407F
Model
Compressor
LC*0050M@ACD 2DC3R53KE
LC*0051M@ACD 2DD3R63KE
LC*0075M@ACD 2DL3R78KE
LC*0076M@ACD 2DA3R89KE
LC*0080M@ACD 3DA3R10ME
LC*0100M@ACD 3DB3R12ME
LC*0120M@ACD 3DF3R15ME
LC*0150M@ACD 3DS3R17ME
+40°F 51,180
— — 84,940 — — — —
Capacity BTUH @ 110°F Ambient by SST
+35°F +30°F +25°F +20°F +15°F +10°F
46,400 41,910 37,590 33,580 29,930 26,660
— 47,450 42,920 38,720 34,770 31,210
—
— 53,190 48,400 44,010 39,930
77,640 70,680 63,890 57,540 51,510 45,940
92,750 84,500 76,490 68,910 61,610 54,540
—
—
87,180 78,840 70,860 63,210
—
—
—
— 78,670 70,190
—
— 120,450 109,330 98,690 88,120
+5°F 23,690 28,020 36,240 40,810 47,910 55,650 62,260 77,890
+0°F 21,040 25,200 33,000 35,970 41,500 48,710 54,310 68,170
-10°F 16,680 20,730 27,670 27,250 29,730 35,350 40,220 49,410
Notes: * H = Outdoor, N = Indoor @ C = 208-230/3/60, D = 460/3/60, E =
575/3/60
24
PERFORMANCE DATA R-407C
Medium Temperature Models – DiscusTM Compressors
Please consult AWEF table on page 38 to confirm DOE compliance per model
R-407C Model
LC0050M@ACD LC0051M@ACD LC0075M@ACD LC0076M@ACD LC0080M@ACD LC0100M@ACD
LC0120M@ACD LC0150M@ACD
Compressor 2DC3R53KE 2DD3R63KE 2DL3R78KE 2DA3R89KE 3DA3R10ME 3DB3R12ME 3DF3R15ME 3DS3R17ME
+40°F 57,780 65,540 79,980 95,180 111,190 128,190 144,160 172,680
Capacity BTUH @ 90°F Ambient by SST +35°F +30°F +25°F +20°F +15°F +10°F
51,970 46,480 41,390 36,630 32,380 28,510 58,940 52,830 47,140 41,950 37,130
32,870 72,320 65,210 58,530 52,340 46,730 41,530 86,060 77,480 69,300 61,730
54,710 48,400 101,710 92,460 83,570 75,140 67,170 59,670 117,670 107,230
97,360 87,910 78,960 70,560 132,710 121,330 110,250 99,550 89,240 79,660
158,620 144,820 131,450 118,640 106,580 95,020
+5°F 25,040 29,080 36,880 42,670 52,760 62,630 70,740 84,170
+0°F 22,020 25,770 32,800 37,510 46,370 55,430 62,620 74,130
-10°F 17,290 20,550 26,300 29,010 35,480 42,750 48,580 56,110
R-407C Model
LC0050M@ACD LC0051M@ACD LC0075M@ACD LC0076M@ACD LC0080M@ACD LC0100M@ACD
LC0120M@ACD LC0150M@ACD
Compressor 2DC3R53KE 2DD3R63KE 2DL3R78KE 2DA3R89KE 3DA3R10ME 3DB3R12ME 3DF3R15ME 3DS3R17ME
+40°F 55,770 63,320 77,360 92,130 107,430 123,800 138,930 166,970
Capacity BTUH @ 95°F Ambient by SST +35°F +30°F +25°F +20°F +15°F +10°F
50,110 44,760 39,810 35,180 31,050 27,310 56,900 50,950 45,420 40,370 35,760
31,600 70,060 63,040 56,560 50,560 45,120 40,090 83,290 74,930 66,950 59,530
52,780 46,590 98,260 89,310 80,690 72,490 64,640 57,350 113,640 103,530 93,950
84,750 76,020 67,780 127,880 116,880 106,120 95,730 85,660 76,310 153,460
140,150 127,210 114,770 103,030 91,680
+5°F 23,960 27,950 35,660 41,010 50,480 60,000 67,670 80,980
+0°F 21,070 24,760 31,800 35,980 44,170 52,740 59,430 71,050
-10°F 16,570 19,850 25,690 27,720 33,230 40,000 45,620 52,950
R-407C Model
LC0050M@ACD LC0051M@ACD LC0075M@ACD LC0076M@ACD LC0080M@ACD LC0100M@ACD
LC0120M@ACD LC0150M@ACD
Capacity BTUH @ 100°F Ambient by SST Compressor +40°F +35°F +30°F +25°F +20°F
+15°F +10°F
2DC3R53KE 53,810 48,310 43,100 38,230 33,780 29,780 26,130 2DD3R63KE 61,140
54,910 49,130 43,770 38,850 34,360 30,380 2DL3R78KE 74,800 67,600 60,920
54,640 48,830 43,580 38,780 2DA3R89KE 89,150 80,550 72,420 64,640 57,420
50,840 44,780 3DA3R10ME 103,650 94,810 86,140 77,760 69,750 62,060 54,910
3DB3R12ME 119,370 109,550 99,900 90,420 81,450 72,910 64,810 3DF3R15ME 133,640
122,960 112,350 101,900 91,760 81,920 72,760 3DS3R17ME 161,260 148,230 135,390
122,880 110,790 99,320 88,110
+5°F 22,930 26,870 34,510 39,370 48,090 57,140 64,240 77,580
+0°F 20,160 23,830 30,840 34,470 41,870 49,870 56,210 67,760
-10°F 15,890 19,200 25,130 26,430 30,860 37,070 42,140 49,620
Notes: * H = Outdoor, N = Indoor
@ C = 208-230/3/60, D = 460/3/60, E = 575/3/60
25
3-22 HP AIR COOLED CONDENSING UNITS
PERFORMANCE DATA R-407C
Medium Temperature Models – DiscusTM Compressors (cont.)
Please consult AWEF table on page 38 to confirm DOE compliance per model
R-407C Model
LC0050M@ACD LC0051M@ACD LC0075M@ACD LC0076M@ACD LC0080M@ACD LC0100M@ACD
LC0120M@ACD LC0150M@ACD
Compressor 2DC3R53KE 2DD3R63KE 2DL3R78KE 2DA3R89KE 3DA3R10ME 3DB3R12ME 3DF3R15ME 3DS3R17ME
+40°F 50,020
— — 83,320 96,150 — — —
Capacity BTUH @ 90°F Ambient by SST
+35°F +30°F +25°F +20°F +15°F +10°F
44,830 39,960 35,380 31,170 27,390 23,980
51,080 45,650 40,660 35,960 31,800 28,120
—
— 50,990 45,580 40,690 36,250
75,210 67,510 60,150 53,300 47,090 41,370
87,860 79,690 71,830 64,070 56,680 49,570
— 92,030 83,170 74,440 66,340 58,310
—
— 93,140 83,480 74,210 65,070
— 125,700 113,930 102,440 91,450 80,600
+5°F 21,010 24,890 32,400 36,170 42,970 50,670 56,600 70,350
+0°F 18,470 22,130 29,120 31,540 36,700 43,640 48,830 60,380
-10°F 14,660 18,060
— 23,910 25,390 30,620
— —
Notes: * H = Outdoor, N = Indoor @ C = 208-230/3/60, D = 460/3/60, E =
575/3/60
26
PERFORMANCE DATA R-404A/R-507A
Low Temperature Models – DiscusTM Compressors
Please consult AWEF table on page 39 to confirm DOE compliance per model
R-404A/R-507A
Model
Compressor
LC*0030L@BCD 2DF3F16KE
LC*0040L@BCD 2DL3F20KE
LC*0060L@BCD 2DB3F25KE
LC*0061L@BCD 3DA3F28KE
LC*0075L@BCD 3DB3F33KE
LC*0090L@BCD 3DF3F40KE
LC*0100L@BCD 3DS3F46KE
LC*0120L@BCD 4DBNF54KE
LC*0150L@BCD 4DHNF63KE
LC*0220L@BCD 4DJNF76KE
+0°F 34,720 38,770 45,520 49,930 58,360 76,720 83,270 97,570 111,010 126,430
-5°F 31,190 34,970 41,220 45,460 53,100 69,450 75,860 88,280 100,980 116,140
Capacity BTUH @ 90°F Ambient by SST
-10°F
-15°F
-20°F
-25°F
27,800 24,530 21,540 18,730
31,360 27,850 24,530 21,480
37,200 33,300 29,560 25,950
41,030 36,820 32,770 28,930
48,160 43,330 38,720 34,260
62,360 55,580 49,230 43,330
68,790 61,820 55,190 48,850
79,570 71,140 63,290 55,790
91,410 82,240 73,570 65,200
105,810 95,900 86,120 76,550
-30°F 16,130 18,630 22,580 25,280 30,010 37,830 42,980 48,690 57,110 67,260
-35°F 13,720 15,980 19,380 21,920 26,050 32,740 37,400 41,680 49,370 57,900
-40°F 11,510 13,510 16,370 18,800 22,290 28,080 32,190 34,670 41,700 48,980
R-404A/R-507A
Model
Compressor
LC*0030L@BCD 2DF3F16KE
LC*0040L@BCD 2DL3F20KE
LC*0060L@BCD 2DB3F25KE
LC*0061L@BCD 3DA3F28KE
LC*0075L@BCD 3DB3F33KE
LC*0090L@BCD 3DF3F40KE
LC*0100L@BCD 3DS3F46KE
LC*0120L@BCD 4DBNF54KE
LC*0150L@BCD 4DHNF63KE
LC*0220L@BCD 4DJNF76KE
+0°F 33,020 36,890 43,290 47,560 55,720 73,480 79,590 93,150 106,100
—
-5°F 29,660 33,270 39,320 43,330 50,740 66,560 72,570 84,320 96,530 110,700
Capacity BTUH @ 95°F Ambient by SST
-10°F
-15°F
-20°F
-25°F
26,390 23,340 20,440 17,720
29,820 26,450 23,320 20,370
35,420 31,700 28,130 24,680
39,100 35,080 31,210 27,460
46,050 41,450 37,040 32,730
59,680 53,300 47,190 41,510
65,870 59,160 52,810 46,760
76,040 67,990 60,370 53,140
87,340 78,640 70,170 62,050
100,820 91,270 81,870 72,590
-30°F 15,180 17,620 21,450 23,970 28,620 36,190 41,110 46,120 54,190 63,410
-35°F 12,840 15,030 18,360 20,710 24,770 31,240 35,710 39,140 46,660 54,500
-40°F 10,680 12,660 15,440 17,630 21,080 26,650 30,640 32,200 39,160 45,610
Notes: * H = Outdoor, N = Indoor models only available as model Rev A
@ C = 208-230/3/60, D = 460/3/60, E = 575/3/60
27
3-22 HP AIR COOLED CONDENSING UNITS
PERFORMANCE DATA R-404A/R-507A
Low Temperature Models – DiscusTM Compressors (cont.)
Please consult AWEF table on page 39 to confirm DOE compliance per model
R-404A/R-507A
Model
Compressor
LC*0030L@BCD 2DF3F16KE
LC*0040L@BCD 2DL3F20KE
LC*0060L@BCD 2DB3F25KE
LC*0061L@BCD 3DA3F28KE
LC*0075L@BCD 3DB3F33KE
LC*0090L@BCD 3DF3F40KE
LC*0100L@BCD 3DS3F46KE
LC*0120L@BCD 4DBNF54KE
LC*0150L@BCD 4DHNF63KE
LC*0220L@BCD 4DJNF76KE
+0°F 31,380 34,990
— — — 70,200 75,830 88,590 — —
-5°F 28,080 31,550 37,290
— — 63,590 69,190 80,280 92,130 —
Capacity BTUH @ 100°F Ambient by SST
-10°F
-15°F
-20°F
-25°F
25,020 22,110 19,330 16,710
28,260 25,060 22,070 19,240
33,610 30,080 26,680 23,410
37,210 33,300 29,580 26,040
43,920 39,550 35,270 31,160
57,120 50,990 45,130 39,670
62,790 56,380 50,370 44,620
72,410 64,670 57,330 50,330
83,380 75,050 66,870 58,990
—
86,680 77,610 68,540
-30°F 14,240 16,600 20,330 22,650 27,240 34,520 39,120 43,450 51,430 59,790
-35°F 11,960 14,100 17,360 19,460 23,460 29,710 33,900 36,540 44,100 50,980
-40°F 9,830 11,810 14,520 16,430 19,810 25,240 28,930 29,690 36,770 42,220
R-404A/R-507A
Model
Compressor +0°F
LC*0030L@BCD 2DF3F16KE
—
LC*0040L@BCD 2DL3F20KE
—
LC*0060L@BCD 2DB3F25KE
—
LC*0061L@BCD 3DA3F28KE
—
LC*0075L@BCD 3DB3F33KE
—
LC*0090L@BCD 3DF3F40KE
—
LC*0100L@BCD 3DS3F46KE
—
LC*0120L@BCD 4DBNF54KE
—
LC*0150L@BCD 4DHNF63KE
—
LC*0220L@BCD 4DJNF76KE
—
Capacity BTUH @ 110°F Ambient by SST
-5°F
-10°F
-15°F
-20°F
-25°F
-30°F -35°F -40°F
—
22,290 19,630 17,050 14,610 12,330 10,150 8,070
—
—
22,290 19,570 16,960 14,530 12,250 10,110
—
—
—
—
20,910 18,100 15,390 12,770
—
—
—
—
22,950 19,770 16,730 13,910
—
—
—
—
28,020 24,380 20,760 17,260
—
—
46,280 41,000 35,930 31,150 26,610 22,380
—
—
—
45,220 39,910 34,840 29,910 25,270
—
—
—
51,000 44,370 37,680 31,070 24,270
—
—
—
—
53,430 46,440 39,470 32,480
—
—
—
—
—
52,250 43,760 —
Notes: * H = Outdoor, N = Indoor models only available as model Rev A @ C =
208-230/3/60, D = 460/3/60, E = 575/3/60
28
PERFORMANCE DATA R-448A/R-449A
Low Temperature Models – DiscusTM Compressors
Please consult AWEF table on page 39 to confirm DOE compliance per model
R-448A/R-449A
Model
Compressor
LC*0030L@BCD 2DF3F16KE
LC*0040L@BCD 2DL3F20KE
LC*0060L@BCD 2DB3F25KE
LC*0061L@BCD 3DA3F28KE
LC*0075L@BCD 3DB3F33KE
LC*0090L@BCD 3DF3F40KE
LC*0100L@BCD 3DS3F46KE
LC*0120L@BCD 4DBNF54KE
LC*0150L@BCD 4DHNF63KE
LC*0220L@BCD 4DJNF76KE
+0°F 30,170 34,930 41,710 46,610 55,730 72,550 78,190 92,720 103,640 125,150
-5°F 26,290 30,890 36,860 41,110 49,480 63,930 68,980 82,620 93,150 111,250
Capacity BTUH @ 90°F Ambient by SST
-10°F
-15°F
-20°F
-25°F
22,820 19,700 16,920 14,420
27,070 23,430 20,110 17,040
32,450 28,300 24,570 21,140
36,090 31,430 27,190 23,350
43,740 38,510 33,570 29,100
55,960 48,610 42,040 36,080
60,530 52,660 45,540 39,090
72,740 63,340 54,530 46,530
83,080 73,250 63,950 55,420
98,440 86,630 75,730 65,580
-30°F 12,210 14,280 17,910 20,020 25,030 30,670 33,260 39,210 47,770 55,760
-35°F 10,210 11,880 14,780 17,090 21,120 25,750 27,890 32,590 40,940 46,390
-40°F 8,370 9,860 11,760 14,540 17,380 21,280 22,990 26,850 35,040 36,730
R-448A/R-449A
Model
Compressor
LC*0030L@BCD 2DF3F16KE
LC*0040L@BCD 2DL3F20KE
LC*0060L@BCD 2DB3F25KE
LC*0061L@BCD 3DA3F28KE
LC*0075L@BCD 3DB3F33KE
LC*0090L@BCD 3DF3F40KE
LC*0100L@BCD 3DS3F46KE
LC*0120L@BCD 4DBNF54KE
LC*0150L@BCD 4DHNF63KE
LC*0220L@BCD 4DJNF76KE
+0°F 28,880 33,480 40,080 44,550 53,460 69,520 74,860 88,540 99,120 119,960
-5°F 25,120 29,570 35,380 39,220 47,380 61,160 66,060 78,830 89,040 106,190
Capacity BTUH @ 95°F Ambient by SST
-10°F
-15°F
-20°F
-25°F
21,790 18,780 16,090 13,670
25,850 22,380 19,140 16,180
31,110 27,090 23,420 20,080
34,370 29,850 25,710 21,990
41,780 36,670 31,840 27,500
53,440 46,250 39,880 34,050
57,720 50,070 43,160 36,850
69,280 60,170 51,720 43,870
79,380 69,890 60,980 52,630
93,800 82,310 71,670 61,640
-30°F 11,520 13,510 16,940 18,770 23,480 28,730 31,090 36,700 45,240 52,220
-35°F 9,570 11,190 13,890 15,920 19,620 23,880 25,840 30,250 38,610 42,850
-40°F 7,760 9,240 10,940 13,430 15,980 19,470 21,050 24,670 32,850 33,380
Notes: * H = Outdoor, N = Indoor models only available as model Rev A
@ C = 208-230/3/60, D = 460/3/60, E = 575/3/60
29
3-22 HP AIR COOLED CONDENSING UNITS
PERFORMANCE DATA R-448A/R-449A
Low Temperature Models – DiscusTM Compressors (cont.)
Please consult AWEF table on page 39 to confirm DOE compliance per model
R-448A/R-449A
Model
Compressor
LC*0030L@BCD 2DF3F16KE
LC*0040L@BCD 2DL3F20KE
LC*0060L@BCD 2DB3F25KE
LC*0061L@BCD 3DA3F28KE
LC*0075L@BCD 3DB3F33KE
LC*0090L@BCD 3DF3F40KE
LC*0100L@BCD 3DS3F46KE
LC*0120L@BCD 4DBNF54KE
LC*0150L@BCD 4DHNF63KE
LC*0220L@BCD 4DJNF76KE
+0°F 27,610 31,970 38,420 42,470 51,150 66,410 71,430 84,290 94,590 114,500
-5°F 23,960 28,170 33,880 37,400 45,240 58,340 62,960 74,940 84,930 101,160
Capacity BTUH @ 100°F Ambient by SST
-10°F
-15°F
-20°F
-25°F
20,760 17,860 15,270 12,930
24,630 21,290 18,180 15,320
29,690 25,830 22,290 19,050
32,610 28,310 24,280 20,670
39,780 34,790 30,150 25,840
50,810 43,950 37,680 31,980
54,820 47,460 40,750 34,590
65,650 56,900 48,740 41,120
75,640 66,480 57,830 49,870
89,140 77,980 67,730 57,860
-30°F 10,840 12,750 15,990 17,510 21,880 26,750 28,930 34,090 42,660 48,560
-35°F 8,930 10,520 13,020 14,690 18,110 21,980 23,760 27,800 36,160 39,300
-40°F 7,150 8,660 10,160 12,290 14,540 17,630 19,040 22,350 30,600 30,130
R-448A/R-449A
Model
Compressor
LC*0030L@BCD 2DF3F16KE
LC*0040L@BCD 2DL3F20KE
LC*0060L@BCD 2DB3F25KE
LC*0061L@BCD 3DA3F28KE
LC*0075L@BCD 3DB3F33KE
LC*0090L@BCD 3DF3F40KE
LC*0100L@BCD 3DS3F46KE
LC*0120L@BCD 4DBNF54KE
LC*0150L@BCD 4DHNF63KE
LC*0220L@BCD 4DJNF76KE
+0°F 25,020 28,850 34,970
— — 60,370 64,690 75,530 85,510 —
-5°F 21,720 25,420 30,790 33,560 40,910 52,650 56,770 66,900 76,650
—
Capacity BTUH @ 110°F Ambient by SST
-10°F
-15°F
-20°F
-25°F
18,740 16,060 13,640 11,460
22,150 19,070 16,210 13,570
26,940 23,330 20,030 16,980
29,110 25,070 21,250 17,930
35,750 30,980 26,460 22,440
45,610 39,170 33,220 27,720
49,250 42,260 35,870 29,930
58,300 50,190 42,470 35,210
68,100 59,510 51,610 44,140
79,820 69,280 59,520 49,950
-30°F 9,490 11,230 14,100 14,910 18,600 22,730 24,530 28,620 37,390 41,080
-35°F 7,690 9,200 11,340 12,260 15,020 18,170 19,590 22,660 31,280 32,240
-40°F 5,980 7,530 8,660 10,010 11,650 13,880 14,950 17,400 26,060 23,390
Notes: * H = Outdoor, N = Indoor models only available as model Rev A @ C =
208-230/3/60, D = 460/3/60, E = 575/3/60
30
PERFORMANCE DATA R-407A/R-407F
Low Temperature Models – DiscusTM Compressors
Please consult AWEF table on page 39 to confirm DOE compliance per model
R-407A/R-407F
Model
Compressor
LC*0030L@BCD 2DF3F16KE
LC*0040L@BCD 2DL3F20KE
LC*0060L@BCD 2DB3F25KE
LC*0061L@BCD 3DA3F28KE
LC*0075L@BCD 3DB3F33KE
LC*0090L@BCD 3DF3F40KE
LC*0100L@BCD 3DS3F46KE
LC*0120L@BCD 4DBNF54KE
LC*0150L@BCD 4DHNF63KE
LC*0220L@BCD 4DJNF76KE
+0°F 30,720 35,250 42,080 46,820 55,850 72,680 77,230 93,530 103,910 117,480
-5°F 26,810 31,330 37,310 41,470 49,780 64,500 68,550 83,540 93,780 106,250
Capacity BTUH @ 90°F Ambient by SST
-10°F
-15°F
-20°F
-25°F
23,330 20,170 17,340 14,740
27,510 23,910 20,510 17,350
32,880 28,770 24,920 21,410
36,580 31,990 27,690 23,720
44,160 38,920 34,050 29,410
56,810 49,500 42,890 36,690
60,530 53,020 45,900 39,460
73,940 64,580 55,560 47,270
83,890 74,320 64,930 56,090
95,530 85,250 75,540 66,130
-30°F 12,360 14,430 18,150 20,110 25,110 30,930 33,350 39,530 47,880 57,200
-35°F 10,140 11,760 15,070 16,630 20,880 25,490 27,510 32,330 40,210 48,330
-40°F 8,030 9,410 12,160 13,300 16,660 20,430 21,830 25,840 33,200 39,660
R-407A/R-407F
Model
Compressor
LC*0030L@BCD 2DF3F16KE
LC*0040L@BCD 2DL3F20KE
LC*0060L@BCD 2DB3F25KE
LC*0061L@BCD 3DA3F28KE
LC*0075L@BCD 3DB3F33KE
LC*0090L@BCD 3DF3F40KE
LC*0100L@BCD 3DS3F46KE
LC*0120L@BCD 4DBNF54KE
LC*0150L@BCD 4DHNF63KE
LC*0220L@BCD 4DJNF76KE
+0°F 29,270 33,670 40,280 44,640 53,400 69,700 73,890 89,060 99,100 112,180
-5°F 25,550 29,900 35,680 39,480 47,530 61,680 65,470 79,480 89,410 101,300
Capacity BTUH @ 95°F Ambient by SST
-10°F
-15°F
-20°F
-25°F
22,210 19,190 16,450 13,950
26,260 22,720 19,480 16,440
31,450 27,430 23,720 20,350
34,760 30,320 26,180 22,350
42,070 37,030 32,180 27,680
54,130 47,020 40,560 34,520
57,680 50,300 43,560 37,250
70,210 61,140 52,580 44,480
79,930 70,700 61,680 53,140
91,200 81,500 72,250 63,180
-30°F 11,640 13,630 17,220 18,790 23,500 28,890 31,330 36,930 45,210 54,600
-35°F 9,490 11,060 14,280 15,370 19,350 23,690 25,650 29,970 37,780 46,050
-40°F 7,430 8,810 11,510 12,140 15,280 18,840 20,220 23,660 30,980 37,600
Notes: * H = Outdoor, N = Indoor models only available as model Rev A @ C =
208-230/3/60, D = 460/3/60, E = 575/3/60
31
3-22 HP AIR COOLED CONDENSING UNITS
PERFORMANCE DATA R-407A/R-407F
Low Temperature Models – DiscusTM Compressors (cont.)
Please consult AWEF table on page 39 to confirm DOE compliance per model
R-407A/R-407F
Model
Compressor
LC*0030L@BCD 2DF3F16KE
LC*0040L@BCD 2DL3F20KE
LC*0060L@BCD 2DB3F25KE
LC*0061L@BCD 3DA3F28KE
LC*0075L@BCD 3DB3F33KE
LC*0090L@BCD 3DF3F40KE
LC*0100L@BCD 3DS3F46KE
LC*0120L@BCD 4DBNF54KE
LC*0150L@BCD 4DHNF63KE
LC*0220L@BCD 4DJNF76KE
+0°F 27,890 32,060 38,440 42,440 50,940 66,750 70,480 84,510 94,270 106,410
-5°F 24,300 28,440 34,020 37,470 45,250 58,900 62,480 75,290 85,020 96,140
Capacity BTUH @ 100°F Ambient by SST
-10°F
-15°F
-20°F
-25°F
21,110 18,200 15,570 13,140
24,910 21,590 18,450 15,520
29,960 26,050 22,520 19,290
32,920 28,700 24,660 20,900
39,950 35,040 30,370 25,990
51,520 44,540 38,250 32,360
54,770 47,650 41,130 35,010
66,400 57,630 49,420 41,590
75,890 67,070 58,450 50,150
86,670 77,530 68,780 60,110
-30°F 10,930 12,820 16,300 17,400 21,870 26,910 29,300 34,250 42,490 51,880
-35°F 8,840 10,380 13,510 14,100 17,820 21,890 23,840 27,500 35,290 43,620
-40°F 6,840 8,230 10,890 10,950 13,870 17,250 18,630 21,400 28,690 35,410
R-407A/R-407F
Model
Compressor
LC*0030L@BCD 2DF3F16KE
LC*0040L@BCD 2DL3F20KE
LC*0060L@BCD 2DB3F25KE
LC*0061L@BCD 3DA3F28KE
LC*0075L@BCD 3DB3F33KE
LC*0090L@BCD 3DF3F40KE
LC*0100L@BCD 3DS3F46KE
LC*0120L@BCD 4DBNF54KE
LC*0150L@BCD 4DHNF63KE
LC*0220L@BCD 4DJNF76KE
+0°F 25,170 28,770 34,640
— — 61,050 63,540 75,210 — —
-5°F 21,850 25,380 30,600 33,430 40,620 53,320 56,040 66,880 76,220
—
Capacity BTUH @ 110°F Ambient by SST
-10°F
-15°F
-20°F
-25°F
18,930 16,260 13,830 11,590
22,200 19,200 16,340 13,670
26,860 23,360 20,090 17,170
29,190 25,250 21,440 17,990
35,620 30,990 26,520 22,440
46,330 39,810 33,740 28,170
48,940 42,280 36,230 30,560
58,580 50,510 42,820 35,430
68,020 59,740 51,730 44,130
76,950 68,850 61,140 53,310
-30°F 9,520 11,230 14,480 14,670 18,480 23,050 25,280 28,610 36,950 45,730
-35°F 7,570 9,040 12,000 11,550 14,690 18,380 20,260 22,320 30,220 38,180
-40°F 5,680 7,130 9,710 8,530 11,000 14,140 15,520 16,510 23,940 30,450
Notes: * H = Outdoor, N = Indoor models only available as model Rev A @ C =
208-230/3/60, D = 460/3/60, E = 575/3/60
32
PERFORMANCE DATA R-407C
Low Temperature Models – DiscusTM Compressors
Please consult AWEF table on page 39 to confirm DOE compliance per model
R-407C Model
LC0030L@BCD LC0040L@BCD LC0060L@BCD LC0061L@BCD LC0075L@BCD LC0090L@BCD
LC0100L@BCD LC0120L@BCD LC0150L@BCD LC0220L@BCD
Compressor 2DF3F16KE 2DL3F20KE 2DB3F25KE 3DA3F28KE 3DB3F33KE 3DF3F40KE 3DS3F46KE 4DBNF54KE 4DHNF63KE 4DJNF76KE
+0°F 26,570 30,760 37,130 41,900 49,790 64,030 68,490 82,720 92,760 106,920
-5°F 23,160 27,190 32,760 36,900 44,010 56,580 60,540 72,560 81,950 94,180
Capacity BTUH @ 90°F Ambient by SST
-10°F
-15°F
-20°F
-25°F
20,110 17,360 14,900 12,710
23,830 20,660 17,680 14,920
28,770 25,030 21,650 18,500
32,290 28,000 24,000 20,330
38,740 33,800 29,300 25,060
49,570 42,970 36,740 31,080
53,000 46,050 39,510 33,510
63,010 54,310 46,290 39,020
72,050 62,650 54,240 46,530
82,860 72,640 63,380 55,020
-30°F 10,720 12,430 15,590 17,010 21,240 25,910 28,050 32,490 39,450 47,360
-35°F 8,870 10,160 12,910 13,960 17,650 21,220 22,970 26,480 33,040 39,930
-40°F 7,100 8,170 10,390 11,260 14,350 17,130 18,380 21,110 27,100 32,610
R-407C Model
LC0030L@BCD LC0040L@BCD LC0060L@BCD LC0061L@BCD LC0075L@BCD LC0090L@BCD
LC0100L@BCD LC0120L@BCD LC0150L@BCD LC0220L@BCD
Compressor 2DF3F16KE 2DL3F20KE 2DB3F25KE 3DA3F28KE 3DB3F33KE 3DF3F40KE 3DS3F46KE 4DBNF54KE 4DHNF63KE 4DJNF76KE
+0°F 25,530 29,620 35,790 40,100 47,860 61,670 65,820 79,200 88,830 102,420
-5°F 22,250 26,140 31,530 35,310 42,170 54,300 58,070 69,330 78,370 90,150
Capacity BTUH @ 95°F Ambient by SST
-10°F
-15°F
-20°F
-25°F
19,300 16,650 14,260 12,120
22,890 19,810 16,890 14,210
27,630 23,980 20,690 17,590
30,770 26,610 22,740 19,130
36,990 32,180 27,730 23,530
47,430 40,900 34,850 29,330
50,760 43,930 37,550 31,710
60,040 51,600 43,770 36,730
68,760 59,770 51,480 43,930
79,340 69,530 60,620 52,560
-30°F 10,140 11,750 14,770 15,910 19,770 24,280 26,420 30,320 37,090 45,080
-35°F 8,300 9,540 12,100 12,920 16,310 19,810 21,500 24,480 30,870 37,800
-40°F 6,520 7,560 9,620 10,260 13,090 15,880 17,070 19,210 25,090 30,630
Notes: * H = Outdoor, N = Indoor models only available as model Rev A
@ C = 208-230/3/60, D = 460/3/60, E = 575/3/60
33
3-22 HP AIR COOLED CONDENSING UNITS
PERFORMANCE DATA R-407C
Low Temperature Models – DiscusTM Compressors (cont.)
Please consult AWEF table on page 39 to confirm DOE compliance per model
R-407C Model
LC0030L@BCD LC0040L@BCD LC0060L@BCD LC0061L@BCD LC0075L@BCD LC0090L@BCD
LC0100L@BCD LC0120L@BCD LC0150L@BCD LC0220L@BCD
Compressor 2DF3F16KE 2DL3F20KE 2DB3F25KE 3DA3F28KE 3DB3F33KE 3DF3F40KE 3DS3F46KE 4DBNF54KE 4DHNF63KE 4DJNF76KE
+0°F 24,490 28,410 34,350 38,230 45,930 59,230 62,970 75,540 84,840 97,600
-5°F 21,330 25,030 30,210 33,590 40,320 51,960 55,330 65,960 74,700 85,850
Capacity BTUH @ 100°F Ambient by SST
-10°F
-15°F
-20°F
-25°F
18,470 15,900 13,580 11,460
21,880 18,860 16,030 13,420
26,370 22,860 19,590 16,610
29,190 25,100 21,340 17,910
35,230 30,450 26,050 22,030
45,230 38,810 32,880 27,520
48,320 41,710 35,480 29,860
56,910 48,770 41,120 34,290
65,390 56,570 48,650 41,290
75,520 66,130 57,620 49,790
-30°F 9,520 11,010 13,810 14,710 18,280 22,600 24,670 27,970 34,700 42,470
-35°F 7,670 8,820 11,220 11,840 14,860 18,260 19,970 22,300 28,600 35,490
-40°F —
6,860 8,760 9,210 11,730 14,510 15,700 17,190 23,010 28,450
R-407C Model
LC0030L@BCD LC0040L@BCD LC0060L@BCD LC0061L@BCD LC0075L@BCD LC0090L@BCD
LC0100L@BCD LC0120L@BCD LC0150L@BCD LC0220L@BCD
Compressor 2DF3F16KE 2DL3F20KE 2DB3F25KE 3DA3F28KE 3DB3F33KE 3DF3F40KE 3DS3F46KE 4DBNF54KE 4DHNF63KE 4DJNF76KE
+0°F 22,390 25,760 31,120 34,300 42,070 54,120 56,860 67,840 76,550
—
-5°F 19,390 22,610 27,220 29,930 36,620 47,130 49,680 58,890 67,100 76,560
Capacity BTUH @ 110°F Ambient by SST
-10°F
-15°F
-20°F
-25°F
16,700 14,270 12,010 9,950
19,590 16,760 14,060 11,550
23,580 20,230 17,160 14,240
25,860 21,980 18,460 15,150
31,710 27,080 22,760 18,770
40,540 34,390 28,790 23,590
43,100 36,730 31,020 25,650
50,470 42,590 35,510 28,930
58,260 50,170 42,570 35,690
66,850 58,440 50,460 43,140
-30°F 8,010 9,220 11,560 12,140 15,180 19,000 20,880 23,020 29,470 36,450
-35°F — —
9,050 9,410 11,890 14,950 16,500 17,650 23,750 29,760
-40°F — — — — —
11,510 12,550
— 18,480 23,180
Notes: * H = Outdoor, N = Indoor models only available as model Rev A @ C =
208-230/3/60, D = 460/3/60, E = 575/3/60
34
UNIT SPECIFICATIONS
Medium & Low Temperature Models – DiscusTM Compressors
Please consult AWEF table on pages 38-39 to confirm DOE compliance per model
Model
LC0050M@ACD LC0051M@ACD LC0075M@ACD LC0076M@ACD LC0080M@ACD LC0100M@ACD
LC0120M@ACD LC0150M@ACD LC0030L@BCD LC0040L@BCD LC0060L@BCD LC0061L@BCD
LC0075L@BCD LC0090L@BCD LC0100L@BCD LC0120L@BCD LC0150L@BCD LC0220L@BCD
Refrigerant Line Rec. Capacity Compressor Connections (OD) @90% full (lbs)
Cabinet
Liquid Suction Std Opt
2DC3R53KE 1/2
1 1/8
28 52
C4
2DD3R63KE 1/2
1 1/8
28 52
C4
2DL3R78KE 1/2
1 1/8
28 52
C4
2DA3R89KE 5/8
1 3/8
67
78
C5
3DA3R10ME 5/8
1 3/8
67
78
C5
3DB3R12ME 5/8
1 3/8
67
78
C5
3DF3R15ME 5/8
1 3/8
67
78
C5
3DS3R17ME 7/8
1 5/8
87
98
C6
2DF3F16KE 1/2
1 1/8
28 52
C4
2DL3F20KE 1/2
1 1/8
28 52
C4
2DB3F25KE 1/2
1 1/8
28 52
C4
3DA3F28KE 1/2
1 1/8
28 52
C4
3DB3F33KE 1/2
1 1/8
28 52
C4
3DF3F40KE 5/8
1 3/8
67
78
C5
3DS3F46KE 5/8
1 3/8
67
78
C5
4DBNF54KE 7/8
1 5/8
87
98
C6
4DHNF63KE 7/8
1 5/8
87
98
C6
4DJNF76KE 7/8
1 5/8
87
98
C6
Dimensions (In.)
Net Wt.
Sound Data
Depth Width Height (lbs.) dBa
36.75 51.75 39.25 751
78
36.75 51.75 39.25 751
78
36.75 51.75 39.25 761
78
36.75 63.75 39.25 985
82
36.75 63.75 39.25 1,020 82
36.75 63.75 39.25 1,045 82
36.75 63.75 39.25 1,065 82
41.75 75.125 48.75 1,182
81
36.75 51.75 39.25 737
78
36.75 51.75 39.25 741
78
36.75 51.75 39.25 751
78
36.75 51.75 39.25 781
81
36.75 51.75 39.25 805
81
36.75 63.75 39.25 1,030 82
36.75 63.75 39.25 1,035 82
41.75 75.125 48.75 1,199
82
41.75 75.125 48.75 1,234
82
41.75 75.125 48.75 1,224 82
Notes: * H = Outdoor, N = Indoor models only available as model Rev Ar
@ C = 208-230/3/60, D = 460/3/60, E = 575/3/60
Estimated sound pressure values are 10 feet from the unit. For estimating
sound pressure from the unit at different distances, deduct the following from
the unit values: 20 feet, deduct 6 dBA; for 40 feet, deduct 12 dBA; for 80
feet, deduct 18 dBA. This data is typical of “free field” conditions for
horizontal air cooled condensing units at the outlet of the discharge air. The
actual sound measurements may vary depending on the condensing unit
installation. Factors such as reflecting walls, background noise and mounting
conditions may have a significant influence on this data.
35
3-22 HP AIR COOLED CONDENSING UNITS
ELECTRICAL DATA R-404A
Medium Temperature Models – DiscusTM Compressors
Please consult AWEF table on page 38 to confirm DOE compliance per model
Model
Compressor
Power
Compressor Condenser
RLAc
LRA
No. FLA Fans (ea)
LC*0050MCACD 2DC3R53KE-TFC 208-230/3/60 20.0 120.0 1 2.7
Remote Loads- Low Amps^ Remote Loads- High Amps^
intelliGenTM/ Beacon II
MCA MOPD
Evap. Fan Amps
Defrost
Htrs. Amps
Electric Defrost
MCA MOPD
Evap. Fan Amps
Defrost
Htrs. Amps
Electric Defrost
MCA MOPD
27.7 45.0 —
—
—-
15 40(1) 50.0 60
LC*0050MDACD 2DC3R53KE-TFD 460/3/60 9.4 60.0 1 1.9 15.0 20.0 —
—
—-
8
20(1) 25.0 30
LC*0050MEACD 2DC3R53KE-TFE 575/3/60 6.9 49.0 1 1.2 15.0 15.0 —
—
—-
6.4 16(1) 20.0 20
LC*0051MCACD 2DD3R63KE-TFC 208-230/3/60 20.0 120.0 1 2.7 27.7 45.0 —
—
—-
15 40(1) 50.0 60
LC*0051MDACD 2DD3R63KE-TFD 460/3/60 9.4 60.0 1 1.9 15.0 20.0 —
—
—-
8
20(1) 25.0 30
LC*0051MEACD 2DD3R63KE-TFE 575/3/60
7.1 49.0 1
1.2 15.0 15.0 —
—
—-
6.4 16(1) 20.0 20
LC*0075MCACD 2DL3R78KE-TFC 208-230/3/60 28.3 169.0 1 2.7 38.1 60.0 —
—
—-
20 48(1) 60.0 80
LC*0075MDACD 2DL3R78KE-TFD 460/3/60 12.4 85.0 1 1.9 20.0 25.0 —
—
—-
10 25(1) 31.3 35
LC*0075MEACD 2DL3R78KE-TFE 575/3/60 11.9 67.0 1 1.2 20.0 25.0 —
—
—-
8
20(1) 25.0 35
LC*0076MCACD 2DA3R89KE-TFC 208-230/3/60 28.7 169.0 2 2.7 41.3 70.0 —
—
—-
20 48(1) 61.3 90
LC*0076MDACD 2DA3R89KE-TFD 460/3/60 12.6 85.0 2 1.9 20.0 30.0 —
—
—-
10 25(1) 31.3 40
LC*0076MEACD 2DA3R89KE-TFE 575/3/60 11.9 67.0 2 1.2 20.0 25.0 —
—
—-
8
20(1) 25.3 35
LC*0080MCACD 3DA3R10ME-TFC 208-230/3/60 36.8 215.0 2 2.7 51.4 80.0 —
—
—-
20 70(2) 87.5 100
LC*0080MDACD 3DA3R10ME-TFD 460/3/60 17.9 106.0 2 1.9 26.2 40.0 —
—
—-
13 35(1) 43.8 50
LC*0080MEACD 3DA3R10ME-TFE 575/3/60 14.7 84.0 2 1.2 20.8 35.0 —
—
— — 10.4 28(1) 35.0 45
LC*0100MCACD 3DB3R12ME-TFC 208-230/3/60 39.1 215.0 2 2.7 54.3 90.0 —
—
—-
20 70(2) 87.5 110
LC*0100MDACD 3DB3R12ME-TFD 460/3/60 17.9 106.0 2 1.9 26.2 40.0 —
—
—-
13 35(1) 43.8 50
LC*0100MEACD 3DB3R12ME-TFE 575/3/60 14.8 84.0 2 1.2 20.9 35.0 —
—
— — 10.4 28(1) 35.0 45
LC*0120MCACD 3DF3R15ME-TFC 208-230/3/60 43.2 275.0 2 2.7 59.4 100.0 —
—
—-
20 70(2) 87.5 110
LC*0120MDACD 3DF3R15ME-TFD 460/3/60 21.2 138.0 2 1.9 30.2 50.0 —
—
—-
13 35(1) 43.8 60
LC*0150MCACD 3DS3R17ME-TFC 208-230/3/60 53.5 275.0 2 4.4 75.7 125.0 15 70(2) 90.7 125 20 80(2) 100.0 125
LC*0150MDACD 3DS3R17ME-TFD 460/3/60 26.0 138.0 2 2.2 36.9 60.0 15 40(1) 51.9 70 15 60(2) 75.0 80
LC*0150MEACD 3DS3R17ME-TFE 575/3/60 21.2 110.0 2 1.8 30.0 50.0 12 32(1) 42.0 60 12 48(1) 60.0 60
Notes: * H = Outdoor, N = Indoor Per UL and NEC, RLA values have been
calculated by dividing the Maximum Continuous Current (MCC) by 1.56. Unless
otherwise noted, model is available for 50 Hz. Consult factory for details. =
Number of defrost heater contactors in parentheses ^ = Two fan large units
have ability for a reduced amp electric defrost kit (low amps). Confirm proper
defrost kit prior to ordering or installing.
36
ELECTRICAL DATA
R-404A
Low Temperature Models – DiscusTM Compressors
Please consult AWEF table on page 39 to confirm DOE compliance per model
Model
LC0030LCBCD LC0030LDBCD LC0030LEBCD LC0040LCBCD
Remote Loads- Low Amps^ Remote Loads- High Amps^
Compressor
Power
Compressor RLAc LRA
Condenser
No. FLA Fans (ea)
intelliGenTM/ Beacon II
MCA MOPD
Evap. Fan Amps
Defrost
Htrs. Amps
Electric Defrost
MCA MOPD
Evap. Fan Amps
Defrost
Htrs. Amps
Electric Defrost
MCA MOPD
2DF3F16KE-TFC 208-230/3/60 14.4 102.0 1 2.7 20.6 35.0 —
—
—
—
15 40(1) 50.0 50
2DF3F16KE-TFD 460/3/60 7.1 52.0 1 1.9 15.0 15.0 —
—
—
—
8 20(1) 25.0 25
2DF3F16KE-TFE 575/3/60 6.0 41.0 1 1.2 15.0 15.0 —
—
—
— 6.4 16(1) 20.0 20
2DL3F20KE-TFC 208-230/3/60 23.6 161.0 1 2.7 32.2 50.0 —
—
—
—
15 48(1) 60.0 70
LC*0040LDBCD 2DL3F20KE-TFD 460/3/60 9.2 60.0 1 1.9 15.0 20.0 —
—
—
—
8
25(1) 31.3 35
LC*0040LEBCD 2DL3F20KE-TFE 575/3/60 6.9 49.0 1 1.2 15.0 15.0 —
—
—
— 6.4 20(1) 25.0 25
LC*0060LCBCD 2DB3F25KE-TFC 208-230/3/60 25.3 161.0 1 2.7 34.4 50.0 —
—
—
—
20 60(2) 75.0 80
LC*0060LDBCD 2DB3F25KE-TFD 460/3/60 11.9 80.0 1 1.9 20.0 25.0 —
—
—
—
10 30(1) 37.5 40
LC*0060LEBCD 2DB3F25KE-TFE 575/3/60 8.6 63.0 1 1.2 15.0 20.0 —
—
—
—
8
24(1) 30.0 30
LC*0061LCBCD 3DA3F28KE-TFC 208-230/3/60 24.0 150.0 1 2.7 32.7 50.0 —
—
—
—
20 60(2) 75.0 80
LC*0061LDBCD 3DA3F28KE-TFD 460/3/60 10.8 77.0 1 1.9 20.0 25.0 —
—
—
—
10 30(1) 37.5 40
LC*0061LEBCD 3DA3F28KE-TFE 575/3/60 9.4 62.0 1 1.2 15.0 20.0 —
—
—
—
8
24(1) 30.0 30
LC*0075LCBCD 3DB3F33KE-TFC 208-230/3/60 27.6 161.0 1 2.7 37.2 60.0 —
—
—
—
20 60(2) 75.0 80
LC*0075LDBCD 3DB3F33KE-TFD 460/3/60 14.1 83.0 1 1.9 20.0 30.0 —
—
—
—
10 30(1) 37.5 40
LC*0075LEBCD 3DB3F33KE-TFE 575/3/60 9.9 67.0 1 1.2 15.0 20.0 —
—
—
—
8
24(1) 30.0 30
LC*0090LCBCD 3DF3F40KE-TFC 208-230/3/60 33.2 215.0 2 2.7 46.9 80.0 —
—
—
—
20 70(2) 87.5 100
LC*0090LDBCD 3DF3F40KE-TFD 460/3/60 15.0 106.0 2 1.9 22.6 35.0 —
—
—
—
13
35(1) 43.8 50
LC*0090LEBCD 3DF3F40KE-TFE 575/3/60 14.1 84.0 2 1.2 20.0 30.0 —
—
—
— 10.4 28(1) 35.0 40
LC*0100LCBCD 3DS3F46KE-TFC 208-230/3/60 37.2 215.0 2 2.7 51.9 80.0 —
—
—
—
20 70(2) 87.5 100
LC*0100LDBCD 3DS3F46KE-TFD 460/3/60 16.7 106.0 2 1.9 24.6 40.0 —
—
—
—
13 35(1) 43.8 50
LC0100LEBCD LC0120LCBCD LC*0120LDBCD
3DS3F46KE-TFE 575/3/60 14.6 84.0 2 4DBNF54KE-TSK 208-230/3/60 46.0 220.0 2 4DBNF54KE-TSK 460/3/60 23.0 110.0 2
1.2 20.6 35.0 — 4.4 66.3 110.0 15 2.2 33.2 50.0 15
—
—
— 10.4 28(1) 35.0 45
40(1) 81.3 125 20 70(2) 87.5 125
25(1) 48.2 70 15 40(1) 50.0 70
LCH0120LEBCD 4DBNF54KE-TSE 575/3/60 15.6 106.0 2 3.4 22.9 35.0 12
20 34.9 50 12
32 40.0 50
LC*0150LCBCD 4DHNF63KE-TSK 208-230/3/60 47.2 278.0 2 4.4 67.8 110.0 15 48(1) 82.8 125 25 70(2) 92.8 125
LC*0150LDBCD 4DHNF63KE-TSK 460/3/60 23.6 139.0 2 2.2 33.9 50.0 15 25(1) 48.9 70 15 40(1) 50.0 70
LCH0150LEBCD 4DHNF63KE-TSE 575/3/60 18.8 113.0 2 3.4 26.9 45.0 12
20 38.9 50 12
32 40.0 50
LC*0220LCBCD 4DJNF76KE-TSK 208-230/3/60 57.7 374.0 2 4.4 80.9 125.0 15 48(1) 95.9 150 25 70(2) 105.9 150
LC*0220LDBCD 4DJNF76KE-TSK 460/3/60 28.8 187.0 2 2.2 40.5 60.0 15 25(1) 55.5 80 15 48(1) 60.0 80
LCH0220LEBCD 4DJN764KE-TSE 575/3/60 26.1 135.0 2 3.4 36.0 60.0 12
20 48.0 70 12
38 48.0 70
Notes: * H = Outdoor, N = Indoor models only available as model Rev A Per UL
and NEC, RLA values have been calculated by dividing the Maximum Continuous
Current (MCC) by 1.56.
Unless otherwise noted, model is available for 50 Hz. Consult factory for
details. = Number of defrost heater contactors in parentheses
^ = Two fan large units have ability for a reduced amp electric defrost kit
(low amps). Confirm proper defrost kit prior to ordering or installing.
37
3-22 HP AIR COOLED CONDENSING UNITS
AWEF DATA MEDIUM TEMPERATURE
DiscusTM Compressor Models – Indoor/Outdoor
If model has a numerical value in the table below, the following statement
applies: This refrigeration system is designed and certified for use in walk-
in cooler applications
Model
LC0050MCACD LC0050MDACD LC0050MEACD LC0051MCACD LC0051MDACD LC0051MEACD
LC0075MCACD LC0075MDACD LC0075MEACD LC0076MCACD LC0076MDACD LC0076MEACD
LC0080MCACD LC0080MDACD LC0080MEACD LC0100MCACD LC0100MDACD LC0100MEACD
LC0120MCACD LC0120MDACD LC0120MEACD LC0150MCACD LC0150MDACD LC0150MEACD
R-404A/ R-507A
5.61 5.61 5.61 5.61 5.61 5.61 5.61 5.61 5.61 5.61 5.61 5.61 5.61 5.61 5.61
5.61 5.61 5.61 — —
X — — —
R-448A
5.61 5.61 5.61 5.61 5.61 5.61 5.61 5.61 5.61 5.61 5.61 5.61 5.61 5.61 5.61
5.61 5.61 5.61 5.61 5.61
X 5.61 5.61 5.61
Indoor
R-449A R-407A
5.61 5.61
5.61 5.61
5.61 5.61
5.61 5.61
5.61 5.61
5.61 5.61
5.61 5.61
5.61 5.61
5.61 5.61
5.61 5.61
5.61 5.61
5.61 5.61
5.61 5.61
5.61 5.61
5.61 5.61
5.61 5.61
5.61 5.61
5.61 5.61
5.61
—
5.61
—
X
X
5.61 5.61
5.61 5.61
5.61 5.61
R-407C
5.61 5.61 5.61 5.61 5.61 5.61 5.61 5.61 5.61 5.61 5.61 5.61 5.61 5.61 5.61
5.61 5.61 5.61 5.61 5.61
X 5.61 5.61 5.61
R-407F
5.61 5.61 5.61 5.61 5.61 5.61 5.61 5.61 5.61 5.61 5.61 5.61 5.61 5.61 5.61
5.61 5.61 5.61 5.61 5.61
X 5.61 5.61 5.61
R-404A/ R-507A
7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60
7.60 7.60 7.60 7.60 7.60
X 7.60 7.60 7.60
R-448A
7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60
7.60 7.60 7.60 7.60 7.60
X 7.60 7.60 7.60
Outdoor
R-449A R-407A
7.60 7.60
7.60 7.60
7.60 7.60
7.60 7.60
7.60 7.60
7.60 7.60
7.60 7.60
7.60 7.60
7.60 7.60
7.60 7.60
7.60 7.60
7.60 7.60
7.60 7.60
7.60 7.60
7.60 7.60
7.60 7.60
7.60 7.60
7.60 7.60
7.60 7.60
7.60 7.60
X
X
7.60 7.60
7.60 7.60
7.60 7.60
R-407C
7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60
7.60 7.60 7.60 7.60 7.60
X 7.60 7.60 7.60
R-407F
7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60
7.60 7.60 7.60 7.60 7.60
X 7.60 7.60 7.60
Notes: * H = Outdoor, N = Indoor X = model not suitable for this refrigerant —
= model is not DOE AWEF compliant If model has a numerical value in the table,
the following statement applies. “This refrigeration system is designed and
certified for use in walk-in cooler applications.”
38
AWEF DATA LOW TEMPERATURE
DiscusTM Compressor Models – Indoor/Outdoor
If model has a numerical value in the table below, the following statement
applies: This refrigeration system is designed and certified for use in walk-
in cooler applications
Model
R-404A/ R-507A
R-448A
Indoor
R-449A R-407A
R-407C
R-407F
R-404A/ R-507A
R-448A
Outdoor
R-449A R-407A
R-407C
R-407F
LC*0030LCBCD 2.40 2.40 2.40 2.40 2.40 2.40 3.15 3.15 3.15 3.15 3.15 3.15
LC*0030LDBCD 2.40 2.40 2.40 2.40 2.40 2.40 3.15 3.15 3.15 3.15 3.15 3.15
LC*0030LEBCD 2.40 2.40 2.40 2.40 2.40 2.40 3.15 3.15 3.15 3.15 3.15 3.15
LC*0040LCBCD 2.40 2.40 2.40 2.40 2.40 2.40 3.15 3.15 3.15 3.15 3.15 3.15
LC*0040LDBCD 2.40 2.40 2.40 2.40 2.40 2.40 3.15 3.15 3.15 3.15 3.15 3.15
LC*0040LEBCD 2.40 2.40 2.40 2.40 2.40 2.40 3.15 3.15 3.15 3.15 3.15 3.15
LC*0060LCBCD 2.40 2.40 2.40 2.40 2.40 2.40 3.15 3.15 3.15 3.15 3.15 3.15
LC*0060LDBCD 2.40 2.40 2.40 2.40 2.40 2.40 3.15 3.15 3.15 3.15 3.15 3.15
LC*0060LEBCD 2.40 2.40 2.40 2.40 2.40 2.40 3.15 3.15 3.15 3.15 3.15 3.15
LC*0061LCBCD 2.40 2.40 2.40 — 2.40 2.40 3.15 3.15 3.15 3.15 3.15 3.15
LC*0061LDBCD 2.40 2.40 2.40 — 2.40 2.40 3.15 3.15 3.15 3.15 3.15 3.15
LC*0061LEBCD 2.40 2.40 2.40 — 2.40 2.40 3.15 3.15 3.15 3.15 3.15 3.15
LC*0075LCBCD 2.40 2.40 2.40 2.40 2.40 2.40 3.15 3.15 3.15 3.15 3.15 3.15
LC*0075LDBCD 2.40 2.40 2.40 2.40 2.40 2.40 3.15 3.15 3.15 3.15 3.15 3.15
LC*0075LEBCD 2.40 2.40 2.40 2.40 2.40 2.40 3.15 3.15 3.15 3.15 3.15 3.15
LC*0090LCBCD 2.40 2.40 2.40 2.40 2.40 2.40 3.15 3.15 3.15 3.15 3.15 3.15
LC*0090LDBCD 2.40 2.40 2.40 2.40 2.40 2.40 3.15 3.15 3.15 3.15 3.15 3.15
LC*0090LEBCD 2.40 2.40 2.40 2.40 2.40 2.40 3.15 3.15 3.15 3.15 3.15 3.15
LC*0100LCBCD 2.40 —
—
— 2.40 2.40 3.15 3.15 3.15 3.15 3.15 3.15
LC*0100LDBCD 2.40 —
—
— 2.40 2.40 3.15 3.15 3.15 3.15 3.15 3.15
LC*0100LEBCD 2.40 —
—
— 2.40 2.40 3.15 3.15 3.15 3.15 3.15 3.15
LC*0120LCBCD 2.40 2.40 2.40 2.40 2.40 2.40 3.15 3.15 3.15 3.15 3.15 3.15
LC*0120LDBCD 2.40 2.40 2.40 2.40 2.40 2.40 3.15 3.15 3.15 3.15 3.15 3.15
LC*0120LEBCD
—
—
—
—
—
—
—
—
—
—
—
—
LC*0150LCBCD 2.40 2.40 2.40 2.40 2.40 2.40 3.15 3.15 3.15 3.15 3.15 3.15
LC*0150LDBCD 2.40 2.40 2.40 2.40 2.40 2.40 3.15 3.15 3.15 3.15 3.15 3.15
LC*0150LEBCD
—
—
—
—
—
—
—
—
—
—
—
—
LC*0220LCBCD 2.40 2.40 2.40 2.40 2.40 2.40 3.15 3.15 3.15 3.15 3.15 3.15
LC*0220LDBCD 2.40 2.40 2.40 2.40 2.40 2.40 3.15 3.15 3.15 3.15 3.15 3.15
LC*0220LEBCD
—
—
—
—
—
—
—
—
—
—
—
—
Notes:
- H = Outdoor, N = Indoor models only available as model Rev A X = model not suitable for this refrigerant — = model is not DOE AWEF compliant If model has a numerical value in the table, the following statement applies. “This refrigeration system is designed and certified for use in walk-in freezer applications.”
39
3-22 HP AIR COOLED CONDENSING UNITS
PERFORMANCE DATA R-404A/R-507A
Medium Temperature Models – Semi-Hermetic Compressors
Please consult AWEF table on page 54 to confirm DOE compliance per model
R-404A/R-507A
Capacity BTUH @ 90°F Ambient by SST
Model
Compressor +40°F +35°F +30°F +25°F +20°F +15°F +10°F
LC*0056M@ABX
4EES-6 86,590 79,740 73,220 66,700 60,620 54,830 49,460
LC*0076M@ABX
4DES-7 103,230 95,180 87,350 79,900 72,530 65,710 59,250
LC*0091M@ABX
4CES-9 130,970 120,260 109,980 99,890 90,490 81,620 73,390
LC*0101M@ABX
4VES-10 136,530 125,260 114,510 103,830 93,750 84,280 75,520
+5°F 44,350 53,300 65,660 67,280
+0°F 39,610 47,690 58,520 59,660
-10°F 31,210 37,730 45,940 46,230
R-404A/R-507A
Capacity BTUH @ 95°F Ambient by SST
Model
Compressor +40°F +35°F +30°F +25°F +20°F +15°F +10°F
LC*0056M@ABX 4EES-6 82,280 75,880 69,670 63,460 57,680 52,260 47,070
LC*0076M@ABX 4DES-7 98,290 90,690 83,240 76,150 69,220 62,640 56,560
LC*0091M@ABX 4CES-9 125,070 114,860 105,060 95,440 86,430 78,020 70,050
LC*0101M@ABX 4VES-10 130,000 119,280 109,010 98,750 89,180 80,260 71,790
+5°F 42,220 50,810 62,650 63,900
+0°F 37,710 45,460 55,790 56,600
-10°F 29,690 35,930 43,700 43,690
R-404A/R-507A
Model
Compressor +40°F
LC*0056M@ABX
4EES-6 78,060
LC*0076M@ABX
4DES-7 93,340
LC*0091M@ABX
4CES-9 119,080
LC*0101M@ABX
4VES-10 123,410
Capacity BTUH @ 100°F Ambient by SST +35°F +30°F +25°F +20°F +15°F +10°F
72,130 66,060 60,240 54,800 49,580 44,670 86,140 79,090 72,300 65,730 59,540
53,780 109,610 100,070 91,080 82,340 74,320 66,710 113,260 103,450 93,880
84,630 76,130 68,060
+5°F 40,070 48,300 59,620 60,530
+0°F 35,780 43,210 53,040 53,520
-10°F 28,130 34,130 41,470 41,200
R-404A/R-507A
Capacity BTUH @ 110°F Ambient by SST
Model
Compressor +40°F +35°F +30°F +25°F +20°F +15°F +10°F
LC*0056M@ABX
4EES-6 69,480 64,150 58,760 53,690 48,820 44,200 39,820
LC*0076M@ABX
4DES-7 83,320 76,980 70,760 64,750 58,770 53,370 48,140
LC*0091M@ABX
4CES-9 106,950 98,480 90,020 81,800 74,160 66,860 59,970
LC*0101M@ABX
4VES-10 110,150 101,350 92,320 83,680 75,630 67,910 60,620
+5°F 35,710 43,230 53,510 53,780
+0°F 31,870 38,640 47,560 47,480
-10°F 25,000 30,440 37,010 36,300
Notes: * H = Outdoor, N = Indoor @ C = 208-230/3/60, D = 460/3/60, E =
575/3/60
40
PERFORMANCE DATA R-448A/R-449A
Medium Temperature Models – Semi-Hermetic Compressors
Please consult AWEF table on page 54 to confirm DOE compliance per model
R-448A/R-449A
Capacity BTUH @ 90°F Ambient by SST
Model
Compressor +40°F +35°F +30°F +25°F +20°F +15°F +10°F
LC*0056M@ABX
4EES-6 86,830 78,910 71,280 64,100 57,430 51,260 45,610
LC*0076M@ABX
4DES-7 101,730 92,350 83,520 75,030 67,270 60,030 53,390
LC*0091M@ABX
4CES-9 128,860 116,720 105,250 94,560 84,580 75,440 67,060
LC*0101M@ABX
4VES-10 134,350 121,660 109,420 97,990 87,330 77,550 68,630
+5°F 40,390 47,270 59,370 60,430
+0°F 35,610 41,670 52,370 52,960
-10°F 27,320 31,910 40,280 40,090
R-448A/R-449A
Capacity BTUH @ 95°F Ambient by SST
Model
Compressor +40°F +35°F +30°F +25°F +20°F +15°F +10°F
LC*0056M@ABX 4EES-6 83,610 75,950 68,560 61,660 55,160 49,190 43,730
LC*0076M@ABX 4DES-7 97,870 88,830 80,290 72,110 64,580 57,570 51,160
LC*0091M@ABX 4CES-9 124,180 112,450 101,340 91,030 81,350 72,490 64,390
LC*0101M@ABX 4VES-10 129,050 116,800 104,970 93,960 83,640 74,280 65,590
+5°F 38,670 45,200 56,950 57,660
+0°F 34,060 39,810 50,170 50,470
-10°F 26,040 30,400 38,490 38,040
R-448A/R-449A
Model
Compressor +40°F
LC*0056M@ABX
4EES-6 80,380
LC*0076M@ABX
4DES-7 94,010
LC*0091M@ABX
4CES-9 119,340
LC*0101M@ABX
4VES-10 123,760
Capacity BTUH @ 100°F Ambient by SST +35°F +30°F +25°F +20°F +15°F +10°F
72,990 65,840 59,200 52,890 47,160 41,840 85,310 77,070 69,240 61,890 55,120
48,920 108,170 97,370 87,430 78,130 69,560 61,730 111,950 100,540 89,860
79,960 70,940 62,570
+5°F 36,960 43,200 54,530 54,930
+0°F 32,510 37,980 47,990 47,990
-10°F 24,780 28,900 36,690 36,020
R-448A/R-449A
Model
Compressor
LC*0056M@ABX
4EES-6
LC*0076M@ABX
4DES-7
LC*0091M@ABX
4CES-9
LC*0101M@ABX
4VES-10
+40°F 74,030 86,320 110,110 113,230
Capacity BTUH @ 110°F Ambient by SST +35°F +30°F +25°F +20°F +15°F +10°F
67,050 60,370 54,180 48,380 43,080 38,130 78,390 70,640 63,430 56,520 50,320
44,520 99,630 89,730 80,370 71,710 63,810 56,470 102,310 91,820 81,880 72,780
64,370 56,610
+5°F 33,590 39,210 49,760 49,530
+0°F 29,460 34,360 43,680 43,100
-10°F 22,280 25,940 33,180 32,030
Notes: * H = Outdoor, N = Indoor
@ C = 208-230/3/60, D = 460/3/60, E = 575/3/60
41
3-22 HP AIR COOLED CONDENSING UNITS
PERFORMANCE DATA R-407A/R-407F
Medium Temperature Models – Semi-Hermetic Compressors
Please consult AWEF table on page 54 to confirm DOE compliance per model
R-407A/R-407F
Capacity BTUH @ 90°F Ambient by SST
Model
Compressor +40°F +35°F +30°F +25°F +20°F +15°F +10°F
LC*0056M@ABX
4EES-6 87,950 80,050 72,420 65,220 58,510 52,280 46,550
LC*0076M@ABX
4DES-7 102,770 93,490 84,750 76,300 68,510 61,130 54,420
LC*0091M@ABX
4CES-9 130,480 118,640 107,100 96,430 86,380 77,140 68,630
LC*0101M@ABX
4VES-10 134,730 122,280 110,300 99,100 88,650 78,920 69,980
+5°F 41,220 48,180 60,780 61,670
+0°F 36,350 42,460 53,590 54,050
-10°F 27,800 32,440 41,100 40,720
R-407A/R-407F
Model
Compressor +40°F
LC*0056M@ABX 4EES-6 84,370
LC*0076M@ABX 4DES-7 98,580
LC*0091M@ABX 4CES-9 125,380
LC*0101M@ABX 4VES-10 129,140
Capacity BTUH @ 95°F Ambient by SST +35°F +30°F +25°F +20°F +15°F +10°F
76,830 69,470 62,480 56,050 50,090 44,510 89,670 81,220 73,010 65,510 58,460
52,000 113,770 102,870 92,560 82,880 73,950 65,750 117,030 105,700 94,800
84,730 75,430 66,720
+5°F 39,380 45,990 58,170 58,720
+0°F 34,680 40,480 51,230 51,380
-10°F 26,440 30,800 39,180 38,520
R-407A/R-407F
Capacity BTUH @ 100°F Ambient by SST
Model
Compressor +40°F +35°F +30°F +25°F +20°F +15°F +10°F
LC*0056M@ABX
4EES-6 80,860 73,600 66,510 59,900 53,630 47,840 42,480
LC*0076M@ABX
4DES-7 94,410 85,840 77,720 69,860 62,590 55,820 49,600
LC*0091M@ABX
4CES-9 120,190 109,230 98,630 88,750 79,360 70,760 62,860
LC*0101M@ABX
4VES-10 123,500 112,060 100,980 90,650 80,810 71,850 63,480
+5°F 37,540 43,810 55,560 55,770
+0°F 33,000 38,500 48,870 48,710
-10°F 25,060 29,190 37,270 36,340
R-407A/R-407F
Model
Compressor
LC*0056M@ABX
4EES-6
LC*0076M@ABX
4DES-7
LC*0091M@ABX
4CES-9
LC*0101M@ABX
4VES-10
+40°F 73,830 86,050 110,160 112,160
Capacity BTUH @ 110°F Ambient by SST +35°F +30°F +25°F +20°F +15°F +10°F
67,140 60,560 54,420 48,670 43,410 38,460 78,190 70,720 63,600 56,790 50,630
44,840 99,910 90,110 80,970 72,370 64,490 57,140 101,720 91,520 81,950 73,060
64,740 57,020
+5°F 33,880 39,490 50,380 49,920
+0°F 29,700 34,590 44,200 43,400
-10°F 22,370 26,010 33,470 32,010
Notes: * H = Outdoor, N = Indoor @ C = 208-230/3/60, D = 460/3/60, E =
575/3/60 35°F Max Superheat
42
PERFORMANCE DATA R-407C
Medium Temperature Models – Semi-Hermetic Compressors
Please consult AWEF table on page 54 to confirm DOE compliance per model
R-407C Model
LC0056M@ABX LC0076M@ABX LC0091M@ABX LC0101M@ABX
Capacity BTUH @ 90°F Ambient by SST Compressor +40°F +35°F +30°F +25°F +20°F
+15°F +10°F
4EES-6 78,590 71,180 64,000 57,360 51,250 45,550 40,240 4DES-7 92,790 84,080
75,890 68,110 60,840 54,170 47,930 4CES-9 117,300 106,200 95,590 85,660 76,570
68,150 60,370 4VES-10 122,430 110,830 99,540 89,230 79,670 70,810 62,570
+5°F 35,380 42,210 53,200 55,020
+0°F 30,920 36,990 46,650 48,080
-10°F 23,020 27,660 35,090 35,740
R-407C Model
LC0056M@ABX LC0076M@ABX LC0091M@ABX LC0101M@ABX
Capacity BTUH @ 95°F Ambient by SST Compressor +40°F +35°F +30°F +25°F +20°F
+15°F +10°F
4EES-6 75,620 68,350 61,550 55,100 49,150 43,660 38,540 4DES-7 89,120 80,750
72,850 65,300 58,390 51,960 45,940 4CES-9 112,850 102,150 91,980 82,370 73,620
65,500 57,960 4VES-10 117,680 106,460 95,690 85,570 76,370 67,830 59,860
+5°F 33,850 40,470 51,070 52,570
+0°F 29,560 35,390 44,750 45,870
-10°F 21,910 26,370 33,570 33,970
R-407C Model
LC0056M@ABX LC0076M@ABX LC0091M@ABX LC0101M@ABX
Compressor 4EES-6 4DES-7 4CES-9 4VES-10
+40°F 72,500 85,480 108,410 112,920
Capacity BTUH @ 100°F Ambient by SST +35°F +30°F +25°F +20°F +15°F +10°F
65,510 58,880 52,770 47,050 41,720 36,820 77,430 69,730 62,560 55,930 49,700
43,940 98,100 88,250 79,150 70,670 62,850 55,580 102,080 91,710 82,010 73,060
64,820 57,120
+5°F 32,310 38,670 48,940 50,110
+0°F 28,190 33,790 42,840 43,700
-10°F 20,790 25,090 32,020 32,210
R-407C Model
LC0056M@ABX LC0076M@ABX LC0091M@ABX LC0101M@ABX
Compressor +40°F 4EES-6 66,280 4DES-7 78,220 4CES-9 99,640 4VES-10 103,530
Capacity BTUH @ 110°F Ambient by SST +35°F +30°F +25°F +20°F +15°F +10°F
59,890 53,780 48,120 42,860 37,930 33,410 70,910 63,760 57,200 51,020 45,250
39,950 90,000 80,930 72,580 64,760 57,490 50,800 93,190 83,560 74,710 66,410
58,700 51,630
+5°F 29,270 35,050 44,660 45,150
+0°F 25,430 30,570 39,030 39,250
-10°F 18,570 22,490 28,940 28,650
Notes: * H = Outdoor, N = Indoor
@ C = 208-230/3/60, D = 460/3/60, E = 575/3/60
43
3-22 HP AIR COOLED CONDENSING UNITS
PERFORMANCE DATA R-404A/R-507A
Low Temperature Models – Semi-Hermetic Compressors
Please consult AWEF table on page 55 to confirm DOE compliance per model
R-404A/R-507A
Model
Compressor
LC*0041L@BBX
4EES-4
LC*0056L@BBX
4DES-5
LC*0061L@BBX
4CES-6
LC*0062L@BBX
4VES-7
LC*0076L@BBX
4TES-9
LC*0101L@BBX
4PES-12
LC*0121L@BBX
4NES-14
LC*0131L@BBX
4JE-15
+0°F 36,520 43,240 54,020 54,370 66,300 74,260 93,290 106,830
-5°F 32,870 38,970 48,340 48,410 59,220 66,200 82,960 95,800
Capacity BTUH @ 90°F Ambient by SST
-10°F
-15°F
-20°F
-25°F
29,430 26,160 23,060 20,250
34,810 30,930 27,370 24,030
42,940 37,970 33,350 29,110
42,710 37,500 32,640 28,110
52,450 46,320 40,580 35,260
58,430 51,390 44,770 38,590
73,480 64,610 56,430 48,890
85,310 75,320 66,230 57,690
-30°F 17,630 20,950 25,190 24,010 30,340 32,970 41,970 49,780
-35°F 15,200 18,070 21,590 20,230 25,820 27,790 35,660 42,400
-40°F 12,940 15,390 18,280 16,780 21,640 23,040 29,870 35,590
R-404A/R-507A
Model
Compressor
LC*0041L@BBX
4EES-4
LC*0056L@BBX 4DES-5
LC*0061L@BBX
4CES-6
LC*0062L@BBX
4VES-7
LC*0076L@BBX
4TES-9
LC*0101L@BBX
4PES-12
LC*0121L@BBX
4NES-14
LC*0131L@BBX
4JE-15
+0°F 34,650 41,050 51,380 51,480 62,850 70,300 88,320 101,480
-5°F 31,190 36,990 45,930 45,690 56,050 62,390 78,520 90,960
Capacity BTUH @ 95°F Ambient by SST
-10°F
-15°F
-20°F
-25°F
27,910 24,790 21,910 19,210
33,060 29,350 25,970 22,790
40,770 36,020 31,620 27,550
40,320 35,360 30,720 26,390
49,640 43,810 38,320 33,240
55,180 48,370 41,990 36,140
69,530 61,070 53,220 45,990
80,850 71,480 62,670 54,470
-30°F 16,710 19,840 23,790 22,470 28,530 30,790 39,420 46,920
-35°F 14,370 17,090 20,360 18,850 24,200 25,870 33,390 39,830
-40°F 12,220 14,540 17,190 15,560 20,230 21,320 27,860 33,300
R-404A/R-507A
Model
Compressor
LC*0041L@BBX
4EES-4
LC*0056L@BBX
4DES-5
LC*0061L@BBX
4CES-6
LC*0062L@BBX
4VES-7
LC*0076L@BBX
4TES-9
LC*0101L@BBX
4PES-12
LC*0121L@BBX
4NES-14
LC*0131L@BBX
4JE-15
+0°F 32,750 38,850 48,720 48,600 59,350 66,150 83,530 96,130
-5°F 29,540 34,930 43,500 43,080 52,880 58,650 74,200 85,960
Capacity BTUH @ 100°F Ambient by SST
-10°F
-15°F
-20°F
-25°F
26,380 23,430 20,720 18,150
31,250 27,810 24,560 21,540
38,580 34,090 29,880 26,000
38,030 33,250 28,770 24,680
46,930 41,300 36,070 31,180
51,840 45,360 39,270 33,710
65,550 57,390 49,960 43,130
76,440 67,540 59,050 51,300
-30°F 15,780 18,740 22,410 20,940 26,730 28,610 36,880 44,010
-35°F 13,550 16,110 19,140 17,520 22,610 23,940 31,130 37,280
-40°F 11,490 13,690 16,120 14,370 18,820 19,620 25,890 31,030
Notes: * H = Outdoor, N = Indoor @ C = 208-230/3/60, D = 460/3/60, E =
575/3/60
44
PERFORMANCE DATA R-404A/R-507A
Low Temperature Models – Semi-Hermetic Compressors (cont.)
Please consult AWEF table on page 55 to confirm DOE compliance per model
R-404A/R-507A
Model
Compressor
LC*0041L@BBX
4EES-4
LC*0056L@BBX
4DES-5
LC*0061L@BBX
4CES-6
LC*0062L@BBX
4VES-7
LC*0076L@BBX
4TES-9
LC*0101L@BBX
4PES-12
LC*0121L@BBX
4NES-14
LC*0131L@BBX
4JE-15
+0°F 28,940 34,410 43,450 42,910 52,520 57,920 73,450 85,490
-5°F 26,100 30,950 38,680 37,910 46,670 51,410 65,330 76,290
Capacity BTUH @ 110°F Ambient by SST
-10°F
-15°F
-20°F
-25°F
23,320 20,750 18,310 16,020
27,680 24,630 21,740 19,030
34,350 30,250 26,450 22,910
33,390 29,080 25,020 21,330
41,390 36,320 31,560 27,190
45,240 39,320 33,920 28,930
57,460 50,250 43,570 37,420
67,800 59,590 52,070 44,920
-30°F 13,870 16,500 19,700 17,950 23,170 24,390 31,800 38,360
-35°F 11,880 14,160 16,740 14,860 19,460 20,180 26,670 32,250
-40°F 10,040 11,980 14,040 12,020 16,060 16,280 21,940 26,570
Notes: * H = Outdoor, N = Indoor
@ C = 208-230/3/60, D = 460/3/60, E = 575/3/60
45
3-22 HP AIR COOLED CONDENSING UNITS
PERFORMANCE DATA R-448A/R-449A
Low Temperature Models – Semi-Hermetic Compressors
Please consult AWEF table on page 55 to confirm DOE compliance per model
R-448A/R-449A
Model
Compressor
LC*0041L@BBX
4EES-4
LC*0056L@BBX
4DES-5
LC*0061L@BBX
4CES-6
LC*0062L@BBX
4VES-7
LC*0076L@BBX
4TES-9
LC*0101L@BBX
4PES-12
LC*0121L@BBX
4NES-14
LC*0131L@BBX
4JE-15
+0°F 33,130 38,760 49,410 49,350 60,470 67,540 84,510 97,990
-5°F 29,210 34,170 43,510 43,170 53,220 59,170 73,940 86,270
Capacity BTUH @ 90°F Ambient by SST
-10°F
-15°F
-20°F
-25°F
25,580 22,270 19,240 16,440
29,900 26,050 22,480 19,190
38,090 33,190 28,690 24,580
37,490 32,310 27,550 23,270
46,550 40,370 34,730 29,550
51,530 44,430 37,900 32,010
64,520 55,820 47,940 40,740
75,590 65,780 56,710 48,410
-30°F 13,880 16,210 20,860 19,400 24,880 26,670 34,250 40,780
-35°F 11,540 13,460 17,440 15,840 20,590 21,820 28,350 33,740
-40°F 9,380 10,930 14,300 12,560 16,670 17,320 22,940 27,260
R-448A/R-449A
Model
Compressor
LC*0041L@BBX 4EES-4
LC*0056L@BBX 4DES-5
LC*0061L@BBX 4CES-6
LC*0062L@BBX 4VES-7
LC*0076L@BBX 4TES-9
LC*0101L@BBX 4PES-12
LC*0121L@BBX 4NES-14
LC*0131L@BBX
4JE-15
+0°F 31,680 36,980 47,280 46,960 57,720 64,220 80,400 93,680
-5°F 27,820 32,530 41,610 40,950 50,650 56,060 70,440 82,490
Capacity BTUH @ 95°F Ambient by SST
-10°F
-15°F
-20°F
-25°F
24,350 21,160 18,240 15,560
28,480 24,730 21,300 18,140
36,390 31,630 27,290 23,330
35,540 30,550 25,970 21,850
44,260 38,320 32,900 27,910
48,720 41,920 35,650 29,990
61,300 52,930 45,310 38,430
72,050 62,580 53,820 45,810
-30°F 13,090 15,270 19,750 18,130 23,420 24,910 32,190 38,430
-35°F 10,840 12,640 16,470 14,720 19,320 20,230 26,530 31,640
-40°F 8,780 10,220 13,470
— — — — —
R-448A/R-449A
Model
Compressor
LC*0041L@BBX 4EES-4
LC*0056L@BBX 4DES-5
LC*0061L@BBX 4CES-6
LC*0062L@BBX 4VES-7
LC*0076L@BBX 4TES-9
LC*0101L@BBX 4PES-12
LC*0121L@BBX 4NES-14
LC*0131L@BBX
4JE-15
+0°F 30,200 35,220 45,170 44,600 54,960 60,880 76,380 89,360
-5°F 26,530 30,940 39,660 38,800 48,140 53,050 66,830 78,500
Capacity BTUH @ 100°F Ambient by SST
-10°F
-15°F
-20°F
-25°F
23,120 20,070 17,260 14,670
27,050 23,440 20,100 17,090
34,670 30,090 25,920 22,100
33,620 28,780 24,410 20,440
42,000 36,290 31,040 26,280
45,950 39,370 33,410 27,990
58,060 50,030 42,710 36,110
68,590 59,390 50,940 43,160
-30°F 12,310 14,350 18,670 16,880 21,960 23,130 30,140 36,090
-35°F 10,160 11,840 15,520 13,590 18,030 18,640 24,710 29,550
-40°F 8,190 9,510 12,650
— — — — —
Notes: * H = Outdoor, N = Indoor @ C = 208-230/3/60, D = 460/3/60, E =
575/3/60 35°F Max Superheat
46
PERFORMANCE DATA R-448A/R-449A
Low Temperature Models – Semi-Hermetic Compressors (cont.)
Please consult AWEF table on page 55 to confirm DOE compliance per model
R-448A/R-449A
Model
Compressor
LC*0041L@BBX
4EES-4
LC*0056L@BBX
4DES-5
LC*0061L@BBX
4CES-6
LC*0062L@BBX
4VES-7
LC*0076L@BBX
4TES-9
LC*0101L@BBX
4PES-12
LC*0121L@BBX
4NES-14
LC*0131L@BBX
4JE-15
+0°F 27,280 31,760 41,000 40,020 49,440 54,000 68,450 80,770
-5°F 23,870 27,810 35,910 34,690 43,260 47,010 59,640 70,740
Capacity BTUH @ 110°F Ambient by SST
-10°F
-15°F
-20°F
-25°F
20,780 17,940 15,330 12,960
24,230 20,900 17,830 15,060
31,320 27,080 23,190 19,700
29,810 25,360 21,330 17,720
37,550 32,290 27,440 23,060
40,430 34,440 29,000 24,090
51,600 44,180 37,510 31,460
61,590 53,060 45,240 38,020
-30°F 10,800 12,550 16,550 14,430 19,120 19,640 26,050
—
-35°F 8,840 10,260 13,680
— — — — —
-40°F 7,040 8,130 11,040
— — — — —
Notes: * H = Outdoor, N = Indoor @ C = 208-230/3/60, D = 460/3/60, E =
575/3/60
35°F Max Superheat
47
3-22 HP AIR COOLED CONDENSING UNITS
PERFORMANCE DATA R-407A/R-407F
Low Temperature Models – Semi-Hermetic Compressors
Please consult AWEF table on page 55 to confirm DOE compliance per model
R-407A/R-407F
Model
Compressor
LC*0041L@BBX
4EES-4
LC*0056L@BBX
4DES-5
LC*0061L@BBX
4CES-6
LC*0062L@BBX
4VES-7
LC*0076L@BBX
4TES-9
LC*0101L@BBX
4PES-12
LC*0121L@BBX
4NES-14
LC*0131L@BBX
4JE-15
+0°F 33,410 39,090 50,060 49,850 61,910 69,060 85,770 94,760
-5°F 29,470 34,430 44,050 43,610 54,460 60,430 75,060 83,130
Capacity BTUH @ 90°F Ambient by SST
-10°F
-15°F
-20°F
-25°F
25,770 22,380 19,260 16,380
30,100 26,150 22,480 19,090
38,550 33,520 28,870 24,610
37,800 32,470 27,510 22,990
47,610 41,220 35,330 29,850
52,590 45,230 38,380 32,110
65,360 56,340 48,050 40,410
72,200 62,040 52,620 43,890
-30°F 13,700 15,970 20,710 18,860 24,840 26,360 33,460 35,760
-35°F 11,250 13,110 17,130 15,080 20,210 21,090 27,050 28,170
-40°F 8,990 10,450 13,830 11,550 15,950 16,180 21,170 21,100
R-407A/R-407F
Model
Compressor
LC*0041L@BBX
4EES-4
LC*0056L@BBX 4DES-5
LC*0061L@BBX
4CES-6
LC*0062L@BBX 4VES-7
LC*0076L@BBX 4TES-9
LC*0101L@BBX
4PES-12
LC*0121L@BBX 4NES-14
LC*0131L@BBX
4JE-15
+0°F 31,820 37,180 47,780 47,280 58,850 65,400 81,540 90,140
-5°F 27,970 32,750 42,050 41,200 51,740 57,190 71,290 78,830
Capacity BTUH @ 95°F Ambient by SST
-10°F
-15°F
-20°F
-25°F
24,450 21,210 18,210 15,440
28,590 24,760 21,230 17,960
36,690 31,860 27,390 23,280
35,710 30,590 25,820 21,490
45,200 39,060 33,390 28,130
49,680 42,610 36,020 30,010
62,000 53,320 45,350 38,020
68,410 58,650 49,600 41,170
-30°F 12,880 14,990 19,550 17,560 23,330 24,500 31,360 33,420
-35°F 10,530 12,250 16,120 13,920 18,900 19,470 25,220 26,160
-40°F 8,370 9,720 12,970 10,550 14,820 14,770 19,610 19,420
R-407A/R-407F
Model
Compressor
LC*0041L@BBX
4EES-4
LC*0056L@BBX
4DES-5
LC*0061L@BBX
4CES-6
LC*0062L@BBX
4VES-7
LC*0076L@BBX
4TES-9
LC*0101L@BBX
4PES-12
LC*0121L@BBX
4NES-14
LC*0131L@BBX
4JE-15
+0°F 30,240 35,300 45,520 44,730 55,980 61,950 77,390 85,460
-5°F 26,550 30,990 39,960 38,890 49,070 54,070 67,670 74,650
Capacity BTUH @ 100°F Ambient by SST
-10°F
-15°F
-20°F
-25°F
23,160 20,050 17,170 14,500
27,060 23,380 20,000 16,860
34,910 30,220 25,930 21,980
33,640 28,670 24,140 20,000
42,810 36,920 31,480 26,430
46,780 39,940 33,690 27,930
58,660 50,320 42,630 35,650
64,680 55,310 46,620 38,540
-30°F 12,060 14,020 18,410 16,250 21,840 22,710 29,280 31,120
-35°F 9,820 11,400 15,130 12,780 17,600 17,880 23,440 24,220
-40°F 7,760 8,990 12,120 9,560 13,710 13,400 18,070 17,780
Notes: Liquid Injection via CIC is required at all operating conditions * H =
Outdoor, N = Indoor @ C = 208-230/3/60, D = 460/3/60, E = 575/3/60 35°F Max
Superheat
48
PERFORMANCE DATA R-407A/R-407F
Low Temperature Models – Semi-Hermetic Compressors (cont.)
Please consult AWEF table on page 55 to confirm DOE compliance per model
R-407A/R-407F
Model
Compressor
LC*0041L@BBX
4EES-4
LC*0056L@BBX
4DES-5
LC*0061L@BBX
4CES-6
LC*0062L@BBX
4VES-7
LC*0076L@BBX
4TES-9
LC*0101L@BBX
4PES-12
LC*0121L@BBX
4NES-14
LC*0131L@BBX
4JE-15
+0°F 27,150 31,620 41,030 39,670 50,080 54,900 69,210 76,690
-5°F 23,750 27,640 35,950 34,430 43,880 47,780 60,340 66,650
Capacity BTUH @ 110°F Ambient by SST
-10°F
-15°F
-20°F
-25°F
20,660 17,780 15,140 12,690
24,060 20,690 17,560 14,720
31,320 27,010 23,060 19,440
29,570 25,000 20,870 17,120
38,080 32,680 27,670 23,090
41,100 34,830 29,120 23,880
52,060 44,420 37,380 31,010
57,400 48,790 40,770 33,430
-30°F 10,460 12,130 16,180 13,700 18,910 19,140 25,210 26,680
-35°F 8,420 9,760 13,190 10,540 15,080 14,760 19,920 20,420
-40°F 6,570 7,580 10,470
— 11,550 10,760 15,060 14,590
Notes: Liquid Injection via CIC is required at all operating conditions * H =
Outdoor, N = Indoor @ C = 208-230/3/60, D = 460/3/60, E = 575/3/60
35°F Max Superheat
49
3-22 HP AIR COOLED CONDENSING UNITS
PERFORMANCE DATA R-407C
Low Temperature Models – Semi-Hermetic Compressors
Please consult AWEF table on page 55 to confirm DOE compliance per model
R-407C Model
LC0041L@BBX LC0056L@BBX LC0061L@BBX LC0062L@BBX LC0076L@BBX LC0101L@BBX
LC0121L@BBX LC0131L@BBX
Compressor 4EES-4 4DES-5 4CES-6 4VES-7 4TES-9 4PES-12 4NES-14 4JE-15
+0°F 28,800 34,550 43,930 44,730 54,800 61,030 75,480 82,820
-5°F 25,110 30,230 38,490 39,060 48,040 53,250 65,850 71,830
Capacity BTUH @ 90°F Ambient by SST
-10°F
-15°F
-20°F
-25°F
21,810
—
—
—
26,250
—
—
—
33,460
—
—
—
33,730
—
—
—
41,710
—
—
—
45,890
—
—
—
56,920
—
—
—
61,740
—
—
—
-30°F — — — — — — — —
-35°F — — — — — — — —
-40°F — — — — — — — —
R-407C Model
LC0041L@BBX LC0056L@BBX LC0061L@BBX LC0062L@BBX LC0076L@BBX LC0101L@BBX
LC0121L@BBX LC0131L@BBX
Compressor 4EES-4 4DES-5 4CES-6 4VES-7 4TES-9 4PES-12 4NES-14 4JE-15
+0°F 27,470 32,980 42,100 42,580 52,280 58,060 72,000 78,850
-5°F 23,940 28,830 36,820 37,140 45,730 50,440 62,730 68,300
Capacity BTUH @ 95°F Ambient by SST
-10°F
-15°F
-20°F
-25°F
20,700
—
—
—
24,990
—
—
—
31,950
—
—
—
31,990
—
—
—
39,690
—
—
—
43,500
—
—
—
54,120
—
—
—
58,450
—
—
—
-30°F — — — — — — — —
-35°F — — — — — — — —
-40°F — — — — — — — —
R-407C Model
LC0041L@BBX LC0056L@BBX LC0061L@BBX LC0062L@BBX LC0076L@BBX LC0101L@BBX
LC0121L@BBX LC0131L@BBX
Compressor 4EES-4 4DES-5 4CES-6 4VES-7 4TES-9 4PES-12 4NES-14 4JE-15
+0°F 26,100 31,370 40,180 40,430 49,830 55,040 68,510 74,950
-5°F 22,730 27,430 35,140 35,140 43,540 47,670 59,510 64,790
Capacity BTUH @ 100°F Ambient by SST
-10°F
-15°F
-20°F
-25°F
19,600
—
—
—
23,720
—
—
—
30,430
—
—
—
30,290
—
—
—
37,670
—
—
—
41,030
—
—
—
51,310
—
—
—
55,250
—
—
—
-30°F — — — — — — — —
-35°F — — — — — — — —
-40°F — — — — — — — —
Notes: * H = Outdoor, N = Indoor @ C = 208-230/3/60, D = 460/3/60, E =
575/3/60 35°F Max Superheat
50
PERFORMANCE DATA R-407C
Low Temperature Models – Semi-Hermetic Compressors (cont.)
Please consult AWEF table on page 55 to confirm DOE compliance per model
R-407C Model
LC0041L@BBX LC0056L@BBX LC0061L@BBX LC0062L@BBX LC0076L@BBX LC0101L@BBX
LC0121L@BBX LC0131L@BBX
Compressor 4EES-4 4DES-5 4CES-6 4VES-7 4TES-9 4PES-12 4NES-14 4JE-15
+0°F 23,450 28,300 36,470 36,200 44,840 48,880 61,430 67,370
-5°F 20,290 24,580 31,720 31,290 38,970 42,260 53,200 57,850
Capacity BTUH @ 110°F Ambient by SST
-10°F
-15°F
-20°F
-25°F
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
-30°F — — — — — — — —
-35°F — — — — — — — —
-40°F — — — — — — — —
Notes: * H = Outdoor, N = Indoor @ C = 208-230/3/60, D = 460/3/60, E =
575/3/60 35°F Max Superheat
51
3-22 HP AIR COOLED CONDENSING UNITS
UNIT SPECIFICATIONS
Medium & Low Temperature Models – BitzerTM Compressors
Please consult AWEF table on pages 54-55 to confirm DOE compliance per model
Model
LC0056M@ABX LC0076M@ABX LC0091M@ABX LC0101M@ABX LC0041L@BBX LC0056L@BBX
LC0061L@BBX LC0062L@BBX LC0076L@BBX LC0101L@BBX LC0121L@BBX LC0131L@BBX
Refrigerant Line Rec. Capacity Compressor Connections (OD) @90% full (lbs)
Liquid Suction Std Opt
4EES-6
5/8
1 3/8
67
78
4DES-7
5/8
1 3/8
67
78
4CES-9
7/8
1 5/8
87
98
4VES-10
7/8
1 5/8
87
98
4EES-4
1/2
1 1/8
28 52
4DES-5
1/2
1 1/8
28 52
4CES-6
5/8
1 3/8
67
78
4VES-7
5/8
1 3/8
67
78
4TES-9
5/8
1 3/8
67
78
4PES-12
5/8
1 3/8
67
78
4NES-14
7/8
1 5/8
87
98
4JE-15
7/8
1 5/8
87
98
Cabinet
C5 C5 C6 C6 C4 C4 C5 C5 C5 C5 C6 C6
Dimensions (In.) Net Wt.
Depth 36.75 36.75 41.75 41.75 36.75 36.75 36.75 36.75 36.75 36.75 41.75 41.75
Width Height 63.75 39.25 63.75 39.25 75.125 48.75 75.125 48.75 51.75 39.25 51.75 39.25 63.75 39.25 63.75 39.25 63.75 39.25 63.75 39.25 75.125 48.75 75.125 48.75
(lbs.) 823 862 993 1,101 595 645 775 865 935 1,000 1,082 1,173
Sound Data dBa 82 82 84 84 78 78 82 82 84 84 84 84
Notes: * H = Outdoor, N = Indoor @ C = 208-230/3/60, D = 460/3/60, E =
575/3/60 Estimated sound pressure values are 10 feet from the unit. For
estimating sound pressure from the unit at different distances, deduct the
following from the unit values: 20 feet, deduct 6 dBA; for 40 feet, deduct 12
dBA; for 80 feet, deduct 18 dBA. This data is typical of “free field”
conditions for horizontal air cooled condensing units at the outlet of the
discharge air. The actual sound measurements may vary depending on the
condensing unit installation. Factors such as reflecting walls, background
noise and mounting conditions may have a significant influence on this data.
52
ELECTRICAL DATA R-404A
Medium & Low Temperature Models – BitzerTM Compressors
Please consult AWEF table on pages 54-55 to confirm DOE compliance per model
Model
LC0076MDABX LC0076MEABX LC0091MCABX LC0091MDABX LC0091MEABX LC0101MCABX
LC0101MDABX LC0101MEABX LC0041LCBBX LC0041LDBBX LC0041LEBBX LC0056LCBBX
LC0056LDBBX LC0056LEBBX LC0061LCBBX LC0061LDBBX LC0061LEBBX LC0062LCBBX
LC0062LDBBX LC0062LEBBX LC0076LCBBX LC0076LDBBX LC0076LEBBX LC0101LCBBX
LC0101LDBBX LC0101LEBBX LC0121LCBBX LC0121LDBBX LC0121LEBBX LC0131LCBBX
LC0131LDBBX LC0131LEBBX
Compressor
4DES-7Y-4SU 4DES-7Y-5SU 4CES-9Y-2DU 4CES-9Y-4SU 4CES-9Y-5SU 4VES-10Y-2NU 4VES-
10Y-2NU 4VES-10Y-5PU 4EES-4Y-2DU 4EES-4Y-4SU 4EES-4Y-5SU 4DES-5Y-2DU 4DES-5Y-
4SU 4DES-5Y-5SU 4CES-6Y-2DU 4CES-6Y-4SU 4CES-6Y-5SU 4VES-7Y-2NU 4VES-7Y-2NU
4VES-7Y-5PU 4TES-9Y-2NU 4TES-9Y-2NU 4TES-9Y-5PU 4PES-12Y-2NU 4PES-12Y-2NU
4PES-12Y-5PU 4NES-14Y-2NU 4NES-14Y-2NU 4NES-14Y-5PU 4JE-15Y-2NU 4JE-15Y-2NU
4JE-15Y-5PU
Power
Compressor Condenser
RLAc
LRA
No. FLA Fans (ea)
460/3/60 15.3 88.0 2 1.9
575/3/60 11.0 63.5 2 1.2
208-230/3/60 37.8 215.0 2 4.4
460/3/60 17.1 88.0 2 2.2
575/3/60 13.7 63.5 2 1.8
208-230/3/60 42.5 222.0 2 4.4
460/3/60 19.2 111.0 2 2.2
575/3/60 15.4 89.0 2 1.8
208-230/3/60 22.2 142.0 1 2.7
460/3/60 9.2 58.0 1 1.9
575/3/60 7.4 41.5 1 1.2
208-230/3/60 22.8 163.0 1 2.7
460/3/60 10.8 66.5 1 1.9
575/3/60 9.0 48.0 1 1.2
208-230/3/60 27.6 215.0 2 2.7
460/3/60 14.2 88.0 2 1.9
575/3/60 11.2 63.5 2 1.2
208-230/3/60 26.9 150.0 2 2.7
460/3/60 12.2 75.0 2 1.9
575/3/60 9.6 60.0 2 1.2
208-230/3/60 31.2 180.0 2 2.7
460/3/60 14.1 90.0 2 1.9
575/3/60 12.2 72.0 2 1.2
208-230/3/60 38.3 222.0 2 2.7
460/3/60 17.3 111.0 2 1.9
575/3/60 14.4 89.0 2 1.2
208-230/3/60 44.0 252.0 2 4.4
460/3/60 19.9 126.0 2 2.2
575/3/60 15.9 101.0 2 1.8
208-230/3/60 55.3 352.0 2 4.4
460/3/60 25.0 176.0 2 2.2
575/3/60 20.0 140.0 2 1.8
Remote Loads- Low Amps Remote Loads- High Amps
intelliGenTM/ Beacon II
MCA MOPD
Evap. Fan Amps
Defrost Htrs. Amps
Electric Defrost
MCA MOPD
Evap. Fan Amps
Defrost Htrs. Amps
Electric Defrost
MCA MOPD
22.9 35.0 — 20.0 25.0 — 56.0 90.0 — 25.7 40.0 — 20.7 30.0 — 61.9 100.0 — 28.4 45.0 — 22.8 35.0 — 30.5 50.0 — 15.0 20.0 — 15.0 15.0 — 31.2 50.0 — 20.0 25.0 — 15.0 20.0 — 39.9 60.0 — 21.5 35.0 — 20.0 25.0 — 39.1 60.0 — 20.0 30.0 — 15.0 20.0 — 44.4 70.0 — 21.4 35.0 — 20.0 25.0 — 53.2 90.0 — 25.4 40.0 — 20.3 30.0 — 63.8 100.0 — 29.2 45.0 — 23.5 35.0 — 78.0 125.0 — 35.7 60.0 — 28.6 45.0 —
—
—-
—
—
—
Notes: * H = Outdoor, N = Indoor
Per UL and NEC, RLA values have been calculated by dividing the Maximum
Continuous Current (MCC) by 1.56.
Unless otherwise noted, model is available for 50 Hz. Consult factory for
details.
53
3-22 HP AIR COOLED CONDENSING UNITS
AWEF DATA MEDIUM TEMPERATURE
BitzerTM Semi-Hermetic Compressor Models – Indoor/Outdoor
If model has a numerical value in the table below, the following statement
applies: This refrigeration system is designed and certified for use in walk-
in cooler applications
Model
LC0056MCABX LC0056MDABX LC0056MEABX LC0076MCABX LC0076MDABX LC0076MEABX
LC0091MCABX LC0091MDABX LC0091MEABX LC0101MCABX LC0101MDABX LC0101MEABX
R-404A/ R-507A
R-448A
5.61 5.61
5.61 5.61
5.61 5.61
5.61 5.61
5.61 5.61
5.61 5.61
5.61 5.61
5.61 5.61
5.61 5.61
5.61 5.61
5.61 5.61
5.61 5.61
Indoor
R-449A R-407A
5.61 5.61 5.61 5.61 5.61 5.61 5.61 5.61 5.61 5.61 5.61 5.61 5.61 5.61 5.61
5.61 5.61 5.61 5.61 5.61 5.61 5.61 5.61 5.61
R-407C
5.61 5.61 5.61 5.61 5.61 5.61 5.61 5.61 5.61 5.61 5.61 5.61
R-407F
R-404A/ R-507A
R-448A
5.61 7.60 7.60
5.61 7.60 7.60
5.61 7.60 7.60
5.61 7.60 7.60
5.61 7.60 7.60
5.61 7.60 7.60
5.61 7.60 7.60
5.61 7.60 7.60
5.61 7.60 7.60
5.61 7.60 7.60
5.61 7.60 7.60
5.61 7.60 7.60
Outdoor
R-449A R-407A
7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60
7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60
R-407C
7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60
R-407F
7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60 7.60
Notes: * H = Outdoor, N = Indoor X = model not suitable for this refrigerant —
= model is not DOE AWEF compliant If model has a numerical value in the table,
the following statement applies. “This refrigeration system is designed and
certified for use in walk-in cooler applications.”
54
AWEF DATA LOW TEMPERATURE
BitzerTM Semi-Hermetic Compressor Models – Indoor/Outdoor
If model has a numerical value in the table below, the following statement
applies: This refrigeration system is designed and certified for use in walk-
in freezer applications
Model
LC0041LCBBX LC0041LDBBX LC0041LEBBX LC0056LCBBX LC0056LDBBX LC0056LEBBX
LC0061LCBBX LC0061LDBBX LC0061LEBBX LC0062LCBBX LC0062LDBBX LC0062LEBBX
LC0076LCBBX LC0076LDBBX LC0076LEBBX LC0101LCBBX LC0101LDBBX LC0101LEBBX
LC0121LCBBX LC0121LDBBX LC0121LEBBX LC0131LCBBX LC0131LDBBX LC0131LEBBX
R-404A/ R-507A
2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40
2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40
R-448A
2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40
— 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40
Indoor
R-449A R-407A
2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40
2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40
2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40 — 2.40 — 2.40
—
R-407C
X X X X X X X X X X X X X X X X X X X X X X X X
R-407F
2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40
2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40
R-404A/ R-507A
3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15
3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15
R-448A
3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15
3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15
Outdoor
R-449A R-407A
3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15
3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15
3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15
3.15 3.15 3.15
R-407C
X X X X X X X X X X X X X X X X X X X X X X X X
R-407F
3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15
3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15 3.15
Notes: * H = Outdoor, N = Indoor X = model not suitable for this refrigerant —
= model is not DOE AWEF compliant If model has a numerical value in the table,
the following statement applies. “This refrigeration system is designed and
certified for use in walk-in freezer applications.”
55
3-22 HP AIR COOLED CONDENSING UNITS
www.interlinkparts.com 800.686.7278
Right source. Right parts. Right now.
InterLinkTM is your link to a complete line of dependable and certified
commercial refrigeration parts, accessories and innovative electronic controls
for all Larkin equipment. At InterLink, we provide our wholesalers with a
comprehensive selection of product solutions and innovative technologies for
the installed customer base. And every product is built to ensure the same
high performance standards with which all Heatcraft Refrigeration Products
brands are built — backed by a dedicated team to serve every customer need,
delivering at the best lead times in the industry.
Dependable. Versatile. Courteous.
Finally, one simple source for all your replacement needs from a name you can
trust.
REPLACEMENT PARTS
Item
PSC Motor, 230/1 PSC Motor, 460/1 PSC Motor, 575/1 EC Motor, 230/1 EC Motor,
460/1 EC Motor, 460/3 Fan Blade Orbus Controller Orbus Transducer, 0-500 psis
Smart Defrost Kit (SDK) SDK Temperature Sensor SDK Transducer, 0-300 psia Fan
Speed Resistor, 230V Fan Speed Resistor, 460V
Replacement Parts
Cabinet
C4
C5
25309004
25309004
25314601
25314601
25309003
25309003
25319104
25319104
25319104*
25319104*
N/A
N/A
7173156
7173156
28962001
28962001
28911204
28911204
28999301
28999301
28902301
28902301
28911202
28911202
N/A
N/A
N/A
N/A
Notes: * = 460/230V transformer is used in unit
56
C6 R033177500 R033177700 25302301 25322601
N/A 25322701 R029218600 28962001 28911204 28999301 28902301 28911202 22542902
22542901
DIMENSIONAL DRAWINGS
C4 CABINET
LEFT
FRONT
36 3/4
C5 CABINET
LEFT
36 3/4
C6 CABINET
LEFT
51 3/4
FRONT
63 3/4
FRONT
39 1/4 39 1/4
48 3/4
41 3/4
75 1/8
49908000
57
2175 West Park Place Blvd. Stone Mountain, GA 30087 Phone: 800.537.7775 · Fax:
770.465.5900
heatcraftrpd.com
Since product improvement is a continuing effort, we reserve the right to make
changes in specifications without notice. LK-HCU-0223 | Version 006
©2023 Heatcraft Refrigeration Products LLC
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>