US-XG-6POE UniFi Switch User Guide
- June 16, 2024
- Unifi
Table of Contents
- US-XG-6POE Quick Start Guide
- Package Contents
- System Requirements
- Hardware Overview
- Hardware Installation
- Grounding (Recommended)
- Using the Cable Clip (Optional)
- Connecting Power
- Using the Power Adapter
- Using the DC Input (Optional)
- Connecting Ethernet
- Connecting SFP+
- Specifications
- Safety Notices
- Electrical Safety Information
- Limited Warranty
- Compliance
- Online Resources
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
US-XG-6POE Quick Start Guide
Package Contents
| |
---|---|---
UniFi Switch| Mount Brackets (Qty. 2)| Bracket Screws (Qty. 8)
| |
Mounting Screws (Qty. 4)| Screw Anchors (Qty. 4)| Power Adapter
|
Power Cord| Cable Clip
System Requirements
- Linux, Mac OS X, or Microsoft Windows 7/8/10
- Java Runtime Environment 1.8 or above recommended
- Web Browser: Google Chrome (Other browsers may have limited functionality)
- UniFi Network Application v5.8.x (or newer), available at: ui.com/download/unifi
Hardware Overview
(1) System LED
Flashing White| Initializing.
Steady White| Factory defaults, waiting for adoption.
Alternating White/Blue| Device is busy; do not touch or unplug it. This
usually indicates that a process such as a firmware upgrade is taking place.
Steady Blue| Successfully adopted by a network and working properly.
Flashing Blue| This is used to locate a device.
When you click Locate in the UniFi Network Application, the System LED will flash blue. The Application will also display the location of the UniFi Switch on the map.
(2) RJ45 PoE LED (Ports 1 – 4)
Off| PoE Disabled
White| 802.3af/at/bt PoE
(3) RJ45 Link/Speed/Activity LED (Ports 1 – 4)
Off| No Link
Flashing Indicates Activity
White| Link Established at 10 Gbps
Flashing Indicates Activity
(4) SFP+ Link/Speed/Activity LED (Ports 5 – 6)
Off| No Link
Green| Link Established at 1 Gbps
Flashing Indicates Activity
White| Link Established at 10 Gbps
Flashing Indicates Activity
(5) RJ45 Console Port
RJ45 serial console port for Command Line Interface (CLI) management. Use an
RJ45-to-DB9, serial console cable, also known as a rollover cable, to connect
the Console port to your computer. Then configure the following settings as
needed:
• Baud rate 115200
• Data bits 8
• Parity NONE
• Stop bits 1
• Flow control NONE
(6) RJ45 (Ports 1 – 4)
RJ45 ports support 100 Mbps or 1/2.5/5/10 Gbps Ethernet connections and
802.3af/at/bt PoE output.
(7) SFP+ (Ports 5 – 6)
Hot-swappable SFP+ ports support 1/10 Gbps connections.
(8) USB Console Port
USB Type C console port for Command Line Interface (CLI) management.
(9) Reset Button
This button serves two functions for the UniFi Switch:
• Restart Press and release the Reset button quickly.
(10) DC Input
Optional DC input for connecting a stand-alone or redundant DC power source
(not included) with minimum power: 40W, 44 to 57VDC.
Note: Ensure the polarity is correct: red is positive (+) and black is negative (-).
You can use the redundant DC power source as a hot spare; if there is no longer power through the Power port, the UniFi Switch will switch to the DC power source without interrupting its operation.
(11) Power Port
Connect the included Power Adapter to the Power port.
(12) Ground
Ancillary grounding point for enhanced ESD protection.
Hardware Installation
The UniFi Switch can be mounted on a horizontal or vertical surface.
WARNING: The US-XG-6POE must not be stacked. Do not place it on top of another switch. Do not place anything on top of the US-XG-6POE.
Grounding (Recommended)
The UniFi Switch is grounded through the Power Adapter; however, you can add optional ESD grounding for enhanced ESD protection.
Note: You also have the option to use the Cable Clip to secure the cord of the Power Adapter. For instructions, proceed to “Using the Cable Clip (Optional)”.
Using the Cable Clip (Optional)
Connecting Power
You have two options:
- “Using the Power Adapter”
- “Using the DC Input (Optional)”
Using the Power Adapter
Using the DC Input (Optional)
For stand-alone power or redundant backup, connect a DC power source to the UniFi Switch.
Note: Only one power source can be used at any one time. With both power sources connected, the input with the highest voltage will be used; the other power source defaults to backup.
Wire a DC/DC cable (not included) to the DC Input. Ensure the polarity is correct: red is positive (+) and black is negative (-).
Connecting Ethernet
Connecting SFP+
For information about compatible fiber SFP modules, visit: community.ubnt.com/unifi
Specifications
US-XG-6POE
Dimensions| 165 x 268.1 x 31.8 mm
(6.50 x 10.56 x 1.25″)
---|---
Weight| 1.3 kg (2.87 lb)
Interfaces
Networking
Management
|
(4) 100 Mbps or 1/2.5/5/10G RJ45 Ports
(2) 1/10G SFP+ Ethernet Ports
Ethernet In-Band
(1) RJ45 Serial Port Out-of-Band
(1) USB Type C Port Out-of-Band
Power Method| 54VDC, 3.88A Power Adapter (Included)
or 44 to 57VDC, 5.56A DC Input with Terminal Block
Power Supply | External AC/DC Adapter (Included)
or
DC Power Source
Supported Voltage Range| 44 to 57VDC
Max. Power Consumption
(Excluding PoE Output)| 40W
LEDs System
RJ45 Data Ports
SFP+ Data Ports|
Status
PoE; Speed/Link/Activity
Link/Activity
ESD/EMP Protection| Air: ± 18 kV, Contact: ± 12 kV
Shock and Vibration| ETSI300-019-1.4 Standard
Operating Temperature| -5 to 45° C (23 to 113° F)
Operating Humidity| 5 to 95% Noncondensing
Certifications| CE, FCC, IC
PoE
PoE Interfaces| PoE++ IEEE 802.3bt
(Pair A 1, 2+; 3, 6-) (Pair B 4 , 5+; 7, 😎
---|---
Max. 802.3bt Wattage per Port by PSE | 60W
Voltage Range 802.3af Mode| 44-57V
Voltage Range 802.3at/bt Mode| 50-57V
Safety Notices
- Read, follow, and keep these instructions.
- Heed all warnings.
- Only use attachments/accessories specified by the manufacturer.
WARNING: Failure to provide proper ventilation may cause fire hazard. Keep at least 20 mm of clearance next to the ventilation holes for adequate airflow.
WARNING: To reduce the risk of fire or electric shock, do not expose this product to rain or moisture.
WARNING: Do not use this product in location that can be submerged by water.
WARNING: Avoid using this product during an electrical storm. There may be a remote risk of electric shock from lightning.
Electrical Safety Information
- Compliance is required with respect to voltage, frequency, and current requirements indicated on the manufacturer’s label. Connection to a different power source than those specified may result in improper operation, damage to the equipment or pose a fire hazard if the limitations are not followed.
- There are no operator serviceable parts inside this equipment. Service should be provided only by a qualified service technician.
- This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet.
a. Do not substitute the power cord with one that is not the provided approved type. Never use an adapter plug to connect to a 2-wire outlet as this will defeat the continuity of the grounding wire.
b. The equipment requires the use of the ground wire as a part of the safety certification, modification or misuse can provide a shock hazard that can result in serious injury or death.
c. Contact a qualified electrician or the manufacturer if there are questions about the installation prior to connecting the equipment.
d. Protective earthing is provided by Listed AC adapter. Building installation shall provide appropriate short-circuit backup protection.
e. Protective bonding must be installed in accordance with local national wiring rules and regulations.
Limited Warranty
ui.com/support/warranty
The limited warranty requires the use of arbitration to resolve disputes on an
individual basis, and, where applicable, specify arbitration instead of jury
trials or class actions.
Compliance
FCC
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions.
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operations of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
ISED Canada
CAN ICES-3(A)/NMB-3(A)
Australia and New Zealand
Warning: This equipment is compliant with Class A of CISPR 32. In a
residential environment this equipment may cause radio interference.
CE Marking
CE marking on this product represents the product is in compliance with all
directives that are applicable to it.
Online Resources
© 2022 Ubiquiti Inc. All rights reserved.
References
- community.ubnt.com/unifi
- UniFi - Rethinking IT - Ubiquiti
- Ubiquiti - Warranty
- community.ubnt.com/
- community.ubnt.com/unifi
- WEEE Compliance Statement
- Software Downloads - Ubiquiti
- UniFi - Rethinking IT - Ubiquiti
- Ubiquiti - Warranty
Read User Manual Online (PDF format)