CH-STLS-14AC Mobile Air Conditioner Local Air Conditioner Owner’s Manual

June 16, 2024
CH

MOBILE AIR CONDITIONER(Local Air Conditioner)
Owner’s Manual & Installation ManualCH-STLS-14AC Mobile Air Conditioner
Local Air ConditionerSmart Kit User’s Manual
https://scnv.io/2HQY?qr=1

IMPORTANT NOTE:
Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference.

Safety Precautions

Read Safety Precautions Before Operation and Installation
To prevent death or injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of  instructions may cause death, harm or damage.

WARNING
This symbol indicates the possibility of personnel injury or loss of life.
CAUTION
This symbol indicates the possibility of property damage or serious consequences.
WARNING

  • Installation must be performed according to the installation instructions. Improper installation can cause water leakage, electrical shock, or fire.
  • Use only the included accessories and parts, and specified tools for the installation. Using nonstandard parts can cause water leakage, electrical shock, fire, and injury or property damage.
  • Make sure that the outlet you are using is grounded and has the appropriate voltage.
  • The power cord is equipped with a three-prong grounding plug to protect against shock.
  • Voltage information can be found on the nameplate of the unit.
  • Your unit must be used in a properly grounded wall receptacle.
  • If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker (the fuse 0or circuit breaker needed is determined 2by the maximum current of the unit.
  • The20 maximum current 02 is indicated on the nameplate located on unit), have a qualified electrician install the proper receptacle.
  • Install the unit on a flat, sturdy surface. Failure to do so could result in damage or excessive noise and vibration.
  • The unit must be kept free from obstruction to ensure proper function and to mitigate safety hazards.
  • Do not modify the length of the power cord or use an extension cord to power the unit.
  • Do not share a single outlet with other electrical appliances. Improper power supply can cause fire or electrical shock.
  • Do not install your air conditioner in a wet room such as a bathroom or laundry room. Too much exposure to water can cause electrical components to short circuit.
  • Do not install the unit in a location that may be exposed to combustible gas, as this could cause fire.
  • The unit has wheels to facilitate moving. Make sure not to use the wheels on thick carpet or to roll over objects, as these could cause tipping.
  • Do not operate a unit that it has been dropped or damaged.
  • The appliance with electric heater shall have at least 1 meter space to the combustible  materials.
  • Do not touch the unit with wet or damp hands or when barefoot.
  • If the air conditioner is knocked over during use, turn off the unit and unplug it from the main power supply immediately.
  • Visually inspect the unit to ensure there is no damage. If you suspect the unit has been damaged, contact a technician or customer service for assistance.
  • In a thunderstorm, the power must be cut off to avoid damage to the machine due to lightning.
  • Your air conditioner should be used in such a way that it is protected from moisture. e.g. condensation, splashed water, etc. Do not place or store your air conditioner where it can fall or be pulled into water or any other liquid. Unplug immediately if it occurs.
  • All wiring must be performed strictly in accordance with the wiring diagram located inside of the unit.
  • The unit’s circuit board(PCB) is designed with a fuse to provide overcurrent protection. The specifications of the fuse are printed on the circuit board, such as: T 3.15A/250V, etc.
  • When the water drainage function is not in use, keep the upper and the lower drain plug firmly to the unit to get rid of choking. When the drain plug is not in use, keep it carefully to prevent children from choking.

CAUTION

  • This appliance can be used by children aged from 8 years and above and person with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. (be applicable for the European Countries)
  • This appliance is not intended for use by persons (including childern) with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
  • Children must be supervised around the unit at all times.(be applicable for other countries except the European Countries )
  • If the supply cord is damaged, it must be replaced by the manufacturer,its service agent or similarly qualified persons in order to avoid a hazard.
  • Prior to cleaning or other maintenance, the appliance must be disconnected from the supply mains.
  • Do not remove any fixed covers. Never use this appliance if it is not working properly, or if it has been dropped or damaged.
  • Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings.
  • Do not route cord under furniture or appliances. Arrange cord away from traffic area and where it will not be tripped over. \
  • Do not operate unit with a damaged cord, plug, power fuse or circuit breaker.
  • Discard unit or return to an authorized service facility for examination and/or repair.
  • To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device.
  • The appliance shall be installed in accordance with national wiring regulations.
  • Contact the authorised service technician for repair  or maintenanceof this unit.
  • Contact the authorised installer for installation of this unit.
  • Do not cover or obstruct the inlet or outlet grilles.
  • Do not use this product for functions other than those described in this instruction manual.
  • Before cleaning, turn off the power and unplug the unit.
  • Disconnect the power if strange sounds, smell, or smoke comes from it.
  • Do not press the buttons on the control panel with anything other than your fingers.
  • Do not remove any fixed covers. Never use this appliance if it is not working properly, or if it has been dropped or damaged.
  • Do not operate or stop the unit by inserting or pulling out the power cord plug.
  • Do not use hazardous chemicals to clean or come into contact with the unit. Do not use the unit in the presence of inflammable substances or vapour such as alcohol, insecticides, petrol,etc.
  • Always transport your air conditioner in a vertical position and stand on a stable, level surface during use.
  • Always contact a qualified person to carry out repairs. If the damaged power supply cord must be replaced with a new power supply cord obtained from the product manufacturer and not repaired.
  • Hold the plug by the head of the power plug when taking it out.
  • Turn off the product when not in use.

Note about Fluorinated Gasses(Not applicable to the unit using R290 Refrigerant)

  1. Fluorinated greenhouse gases are contained in hermetically sealed equipment. For specific information on the type, the amount and the CO2 equivalent in tonnes of the fluorinated greenhouse gas(on some models), please refer to the relevant label on the unit itself.
  2. Installation, service, maintenance and repair of this unit must be performed by a certified technician.
  3. Product uninstallation and recycling must be performed by a certified technician.

Sociable Remark
When using this appliance in the European countries, the following information must be followed:
DISPOSAL: Do not dispose this product as unsorted municipal waste.
Collection of such waste separately for special treatment is necessary.
It is prohibited to dispose of this appliance in domestic household waste.
For disposal, there are several possibilities:

  • The municipality has established collection systems, where electronic waste can be disposed of at least free of charge to the user.
  • When buying a new product, the retailer will take back the old product at least free of charge.
  • The manufacture will take back the old appliance for disposal at least free of charge to the user.
  • As old products contain valuable resources, they can be sold to scrap metal dealers. Wild disposal of waste in forests and landscapes endangers your health when hazar do us substances leak into the ground-water and find their way into the food chain.

UV-C lamp(Applicable to the unit contains an UV-C lamp only)
This appliance contains a UV-C lamp. Read the maintenance instructions before opening the appliance.

  1. Do not operate UV-C lamps outside of the appliance.
  2. Appliances that are obviously damaged must not be operated.
  3. Unintended use of the appliance or damage to the housing may result in the escape of dan gerous UV-C radiation. UV-C radiation may, even in small doses, cause harm to the eyes and skin.
  4. Before opening doors and access panels bearing the ULTRAVIOLET RADIATION hazard symbol for the conducting USER MAINTENANCE, it is recommended to disconnect the power.
  5. The UV-C lamp can not be cleaned, repaired and replaced.
  6. UV-C BARRIERS bearing the ULTRAVIOLET RADIATION hazard symbol should not be removed.

WARNING This appliance contains an UV emitter. Do not stare at the light source. WARNING

WARNING for Using R32/R290 Refrigerant

  • Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
  • The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater).
  • Do not pierce or burn.
  • Be aware that the refrigerants may not contain an odour.
  • Appliance should be installed, operated and stored in a room with a floor area according to the amount of refrigerant to be charged
  • For specific information on the type of gas and the amount, please refer to the relevant label on the unit itself.
  • When there are differences between the lable and the manual on the Min. room area description, the description on label shall prevail.

For R290(Not applicable for North America)

amount of refrigerant (kg)| Min. room area(m2)| amount of refrigerant (kg)| Min. room area(m2)
---|---|---|---
0.0836| 4| >0.1881 and 0.2090| 10

0.0836 and 0.1045| 5| >0.2090 and 0.2299| 11
0.1045 and 0.1254| 6| >0.2299 and 0.2508| 12
0.1254 and 0.1463| 7| >0.2508 and 0.2717| 13
0.1463 and 0.1672| 8| >0.2717 and 0.2926| 14
0.1672 and 0.1881| 9| >0.2926 and 0.3040| 15

For R32 frigerant models:

  • Appliance shall be installed, operated and stored in a room with a floor area larger than 4 m2.
  • Appliance shall not be installed in an unvertilated space, if that space is smaller than 4 m2.
  • Compliance with national gas regulations shall be observed.
  • Keep ventilation openings clear of obstruction.
  • The appliance shall be stored so as to prevent mechanical damage from occurring.
  • A warning that the appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation.
  • Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry-accredited assessment authority, which authorises their competence to handle refrigerants safely in accordance with an industry recognised assessment specification.
  • Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants.
  • Please follow the instruction carefully to handle, install, clear, service the air conditioner to avoid any damage or hazard. Flammable Refrigerant R32 is used within air conditioner. When maintaining or disposing the air conditioner, the refrigerant (R32 or R290) shall be recovered properly, shall not discharge to air directly.
  • No any open fire or device like switch which may generate spark/arcing shall be around air conditioner to avoid causing ignition of the flammable refrigerant used.
  • Please follow the instruction carefully to store or maintain the air conditioner to prevent mechanical damage from occurring.
  • Flammable refrigerant -R32 is used in air conditioner. Please follow the instruction carefully to avoid any hazard.For speci-c information on the type of gas and the amount,please to the relevant label on the unit itself.
  • The appliance shall be stored in a room without continuously operating open flames (for example an operating gas appliance) and ignition sources (for example an operating electric heater).

Caution: Risk of fire/flammable materials
(Required for R32/R290 units only)
Warning: low burning velocity material
(For R32 models apply to IEC60335-2-40:2018)
Explanation of symbols displayed on the unit(For the unit adopts R32/R290 Refrigerant only):
WARNING
This symbol shows that this appliance used a flammable refrigerant. If the refrigerant is leaked and exposed to an external ignition source, there is a risk of fire.
CAUTION
This symbol shows that the operation manual should be read carefully.
CAUTION
This symbol shows that a service personnel should be handling this equipment with reference to the installation manual.
CAUTION
This symbol shows that information is available such as the operating manual or installation manual.

  1. Transport of equipment containing flammable refrigerants
    See transport regulations

  2. Marking of equipment using signs
    See local regulations

  3. Disposal of equipment using flammable refrigerants
    See national regulations.

  4. Storage of equipment/appliances
    The storage of equipment should be in accordance with the manufacturer’s instructions.

  5. Storage of packed (unsold) equipment
    Storage package protection should be constructed such that mechanical damage to the equipment inside the package will not cause a leak of the refrigerant charge. The maximum number of pieces of equipment permitted to be stored together will be determined by local regulations.

  6. Information on servicing

  7. Checks to the area
    Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimised. For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work on the system.

  8. Work procedure
    Work shall be undertaken under a controlled procedure so as to minimise the risk of a flammable gas or vapour being present while the work is being performed.
    Work shall be undertaken under a controlled procedure so as to minimise the risk of a flammable gas or vapour being present while the work is being performed.

  9. General work area
    All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confined spaces shall be avoided. The area around the workspace shall be sectioned off. Ensure that the conditions within the area have been made safe by control of flammable material.

  10. Checking for presence of refrigerant
    The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the technician is aware of potentially flammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants, i.e. non-sparking, adequately sealed or intrinsically safe.

  11. Presence of fire extinguisher
    If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fire extinguishing equipment shall be available to hand. Have a dry powder or CO2 fire extinguisher adjacent to the charging area.

  12. No ignition sources
    No person carrying out work in relation to a refrigeration system which involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion. All possible ignition sources, including cigarette smoking, should be kept sufficiently far away from the site of installation, repairing, removing and disposal, during which flammable refrigerant can possibly be released to the surrounding space. Prior to work taking place, the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks. No Smoking signs shall be displayed.

  13. Ventilated area
    Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere.

  14. Checks to the refrigeration equipment
    Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer’s maintenance and service guidelines shall be followed. If in doubt consult the manufacturer’s technical department for assistance. The following checks shall be applied to installations using flammable refrigerants:
    The charge size is in accordance with the room size within which the refrigerant containing parts are installed;
    The ventilation machinery and outlets are operating adequately and are not obstructed;
    If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant; Marking to the equipment continues to be visible and legible. Markings and signs that are illegible shall be corrected;
    Refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant containing components, unless the components are co nstructed of materials which are inherently resistant to being corroded or are suitably protected against being so corroded.

  15. Checks to electrical devices
    Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution shall be used. This shall be reported to the owner of the equipment so all parties are advised.
    Initial safety checks shall include:
    That capacitors are discharged: this shall be done in a safe manner to avoid possibility of sparking;
    That there no live electrical components and wiring are exposed while charging, recovering or purging the system; That there is continuity of earth bonding.

  16. Repairs to sealed components

  17. During repairs to sealed components, all electrical supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers, etc. If it is absolutely necessary to have an electrical supply to equipment during servicing, then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation.

  18. Particular attention shall be paid to the following to ensure that by working on electrical components, the casing is not altered in such a way that the level of protection is affected. This shall include damage to cables, excessive number of connections, terminals not made to original specification, damage to seals, incorrect fitting of glands, etc. Ensure that apparatus is mounted securely. Ensure that seals or sealing materials have not degraded such that they no longer serve the purpose of preventing the ingress of flammable atmospheres. Replacement parts shall be in accordance with the manufacturer’s specifications.
    NOTE: The use of silicon sealant may inhibit the effectiveness of some types of leak detection equipment. Intrinsically safe components do not have to be isolated prior to working on them.

  19. Repair to intrinsically safe components
    Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will not exceed the permissible voltage and current permitted for the equipment in use. Intrinsically safe components are the only types that can be worked on while live in the presence of a flammable atmosphere. The test apparatus shall be at the correct rating. Replace components only with parts specified by the manufacturer. Other parts may result in the ignition of refrigerant in the atmosphere from a leak.

  20. Cabling
    Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges or any other adverse environmental effects. The check shall also take into account the effects of aging or continual vibration from sources such as compressors or fans.

  21. Detection of flammable refrigerants
    Under no circumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks. A halide torch (or any other detector using a naked flame) shall not be used.

  22. Leak detection methods
    The following leak detection methods are deemed acceptable for systems containing flammable refrigerants. Electronic leak detectors shall be used to detect flammable refrigerants, but the sensitivity may not be adequate, or may need re-calibration. (Detection equipment shall be calibrated in a refrigerant-free area.) Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant used. Leak detection equipment shall be set at a percentage of the LFL of the refrigerant and shall be calibrated to the refrigerant employed and the appropriate percentage of gas (25 % maximum) is confirmed. Leak detection fluids are suitable for use with most refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the copper pipe-work. If a leak is suspected, all naked flames shall be removed/ extinguished. If a leakage of refrigerant is found which requires brazing, all of the refrigerant shall be recovered from the system, or isolated (by means of shut off valves) in a part of the system remote from the leak. Oxygen free nitrogen (OFN) shall then be purged through the system both before and during the brazing process.

  23. Removal and evacuation
    When breaking into the refrigerant circuit to make repairs or for any other purpose conventional procedures shall be used. However, it is important that best practice is followed since flammability is a consideration. The following procedure shall be adhered to:
    Remove refrigerant; Purge the circuit with inert gas; Evacuate; Purge again with inert gas; Open the circuit by cutting or brazing.
    The refrigerant charge shall be recovered into the correct recovery cylinders. The system shall be flushed with OFN to render the unit safe.
    This process may need to be repeated several times. Comp ressed air oroxygen shall not be used for this task.
    Flushing shall be achieved by breaking the vacuum in the system with OFN and continuing to fill until the working pressure is achieved, then venting to atmosphere, and finally pulling down to a vacuum.
    This process shall be repeated until no refrigerant is within the system. When the final OFN charge is used, the system shall be vented down to atmospheric pressure to enable work to take place.
    This operation is absolutely vital if brazing operations on the pipe-work are to take place.
    Ensure that the outlet for the vacuum pump is not close to any ignition sources and there is ventila tion available.

  24. Charging procedures
    In addition to conventional charging procedures, the following requirements shall be followed. Ensure that contamination of different refrigerants does not occur when using charging equipment. Hoses or lines shall be as short as possible to minimise the amount of refrigerant contained in them.
    Cylinders shall be kept upright.
    Ensure that the refrigeration system is earthed prior to charging the system with refrigerant.
    Label the system when charging is complete (if not already).
    Extreme care shall be taken not to overfill the refrigeration system. Prior to recharging the system it shall be pressure tested with OFN. The system shall be leak tested on completion of charging but prior to commissioning. A follow up leak test shall be carried out prior to leaving the site.

  25. Decommissioning
    Before carrying out this procedure, it is essential that the technician is completely familiar with the equipment and all its detail. It is recommended good practice that all refrigerants are recovered safely.
    Prior to the task being carried out, an oil and refrigerant sample shall be taken in case analysis is required prior to re-use of reclaimed refrigerant. It is essential that electrical power is available before the task is commenced.
    a) Become familiar with the equipment and its operation.b) Isolate system electrically.c) Before attempting the procedure ensure that: Mechanical handling equipment is available, if required, for handling refrigerant cylinders;All personal protective equipment is available and being used correctly;
    The recovery process is supervised at all times by a competent person; Recovery equipment and cylinders conform to the appropriate standards.d) Pump down refrigerant system, if possible.e) If a vacuum is not possible, make a manifold so that refrigerant can be removed from various parts of the system.f) Make sure that cylinder is situated on the scales before recovery takes place.g) Start the recovery machine and operate in accordance with manufacturer’s instructions.h) Do not overfill cylinders. (No more than 80 % volume liquid charge).i) Do not exceed the maximum working pressure of thecylinder, even temporarily.j) When the cylinders have been filled correctly and the process completed, make sure that the cylinders and the equipment are removed from site promptly and all isolation valves on the equipment are closed off.k) Recovered refrigerant shall not be charged into another refrigeration system unless it has been cleaned and checked.

  26. Labelling
    Equipment shall be labelled stating that it has been de-commissioned and emptied of refrigerant. The label shall be dated and signed. Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant.

  27. Recovery
    When removing refrigerant from a system, either for servicing or decommissioning, it is recommended good practice that all refrigerants are removed safely. When transferring refrigerant into cylinders, en sure that only appropriate refrigerant recovery cylinders are employed. Ensure that the correct number of cylinders for holding the total system charge is available. All cylinders to be used are designated for the recovered refrigerant and labelled for that refrigerant (i.e. special cylinders for the recovery of refrigerant). Cylinders shall be complete with pressure relief valve and associated shut-off valves in good working order. Empty recovery cylinders are evacuated and, if possible, cooled before recovery occurs. The recovery equipment shall be in good working order  with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of flammable refrigerants. In addition, a set of calibrated weighing scales shall be available and in good working order. Hoses shall be com plete with leak- free disconnect couplings and in good condition. Before using the recovery machine, check that it is in satisfactory working order, has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release. Consult manufacturer if in doubt. The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder, and the relevant Waste Transfer Note arranged. Do not mix refrigerants in recovery units and especially not in cylinders. If compressors or compressor oils are to be removed, ensure that they have been evacuated to an acceptable level to make certain that flammable refrig erant does not remain within the lubricant. The evacuation process shall be carried out prior to ret urning the compressor to the suppliers. Only electric heating to the compressor body shall be empl oyed to accelerate this process. When oil is drained from a system, it shall be carried out safely.

Operation of Current Device

The power supply cord contains a current measuring device that detects damage to the power cord. Test your power supply cord as follows:

  1. Plug in the air conditioner.

  2. The power supply cord will have TWO buttons on the plug head. Press the TEST button. You will notice a click as the RESET button pops out.
    CH-STLS-14AC Mobile Air Conditioner Local Air Conditioner -
Plug

  3. Press the RESET Button. You will notice a click as the button engages.

  4. The power supply cord is now supplying electricity to the unit. (On some products this is also indicated by a light on the plug head.)CH-STLS-14AC Mobile Air Conditioner Local Air Conditioner - Plug 1

NOTICE
The power supply cord with this air conditioner contains a current detection device designed to reduce the risk of fire.In the event that the power supply cord is damaged, it can not be repaired. It must be replaced with a cord from the manufacturer

NOTICE

  • Do not use this device to turn the unit on or off.
  • Always make sure the RESET button is pushed in for correct operation.
  • The power supply cord must be replaced if it fails to reset when either the TEST button is pushed, or it can not be reset. Please contact Customer Service.

Installation Instructions

Preparation
NOTE:

All the illustrations in the manual are for explanation purpose only. Your machine may be slightly different.
The actual shape shall prevail. The unit can be controlled by the unit control panel alone or with the remote controller. This manual does not include Remote Controller Operations, see the <> packed with the unit for details.

CH-STLS-14AC Mobile Air Conditioner Local Air Conditioner -
Preparation Design Notice
In order to ensure the optimal performance of our products, the design specifications of the unit and remote control are subject to change without prior notice.
Exhaust Hose Installation
The exhaust hose and adaptor must be installed or removed in accordance with the usage mode. For COOL,HEAT(heat pump type) or AUTO mode must be installed exhaust hose. For FAN, DRY or HEAT (electrical heat type) mode must be removed exhaust hose.

AmbientTemperature Range For Unit Operating

MODE Temperature Range MODE Temperature Range
Cool 60-95°F (16-35°C) Heat(pump heat mode) 41-86°F(5-30°C )
Dry 55-95°F (13-35°C) Heat(electrical heat mode) 86°F(30°C )

Choosing The Right Location
CH-STLS-14AC Mobile Air Conditioner Local Air Conditioner - Choosing The
Right Location Your installation location should meet the following requirements:
-Make sure that you install your unit on an even surface to minimize noise and vibration.
-The unit must be installed near a grounded plug, and the Collection Tray Drain (found on the back of the unit) must be accessible.
-The unit should be located at least 25cm (9.8”) from the nearest wall to ensure proper air conditioning. The horizontal louver blade should be at least 50cm(19.7”) away from obstacles.
-DO NOT cover the Intakes, Outlets or Remote Signal Receptor of the unit, as this could cause damage to the unit.
Recommend Installation

NOTICE
The appearance of your unit might be slightly different.
CH-STLS-14AC Mobile Air Conditioner Local Air Conditioner - Choosing The
Right Location 1 WARNING
This air-conditioning unit is a hermetically sealed unit that contains fluorinated gasses. For specific information on the type of gas and the amount, please refer to the relevant label on the unit itself.
Service, maintenance or repair of this unit must be performed by a certified technician.
Product recycling must be done according to local regulations.

Energy Rating Information
Mobile air conditioner with combined exhaust hose need the Exhuast Adaptor to test the condenser inlet and outlet airflows. The Exhuast Adaptor must be provided by the manufacturer. The Exhuast Adaptor connect the condenser inlet and outlet airflows to the airflow measuring instrument in laboratory.
How to Stay Cool with a New Portable Air Conditioner(For the models comply with the requirements of Department Of Energy in US)
Because of a new federal test procedure for Portable Air Conditioners, you may notice that the cooling capacity claims on portable air conditioner packaging are significantly lower than that of models produced prior to 2017. This is due to changes in the test procedure, not to the portable air conditioners themselves.
What should I look for first when purchasing a portable air conditioner?
The right air conditioner helps you cool a room efficiently. An undersized unit won’t cool adequately while one that’s too large will not remove enough humidity, leaving the air feeling damp. To find the proper air conditioner, determine the square footage of the room you want to cool by multiplying the room length by its width. You also need to know the air conditioner’s BTU (British Thermal Unit) rating, which indicates the amount of heat it can remove from a room. A higher number means more cooling power for a larger room. (Be sure you are comparing only newer models to each other- older models may appear to have a higher capacity, but are actually the same). Be sure to “size up” if your portable air conditioner will be placed in a very sunny room, in a kitchen, or in a room with high ceilings. After you’ve found the right cooling capacity or your room, you can look at other features.
Why is the cooling capacity lower on newer models than on older units?
Federal regulations require manufacturers to calculate cooling capacity based on a specific test procedure, which was changed just this year. Models manufactured before 2017 were tested under a different procedure and cooling capacity is measured differently than in prior years’models. So, while the BTUs may be lower, the actual cooling capacity of the air conditioners has not changed.
What is SACC ?
SACC is the representative value of Seasonally Adjusted Cooling Capacity, in Btu/h, as determined in accordance with the DOE test procedure at title 10 Code of Federal Regulations (CFR) 430, subpart B, appendix CC and applicable sampling plans.

Tools Needed
-Philips screwdriver;
-Tape measure or ruler;
Accessories
NOTE: Your window Installation Kit fits windows 19.1’’-63.8’’(48.4-162cm). Please doublecheck all packaging materials to make sure accessories do not get accidentally thrown away. Items with (*) are on some models. Slight variations in design may occur.
-Knife or scissors;
-Saw (optional, to shorten window adaptor for narrow windows)

Shape

| Name of Accessories| Qty.| Shape| Name of Accessories|

Qty.

---|---|---|---|---|---
| Air exhaust adapter| 1 pc| | Window Slider Foam (adhesive)| 2 pc()
| Bolt| 1 – 8 pc| | Security Bracket and 2 Screws| 1 set
| Window Sliders(model dependent)| 2-5 pc(
)| | Drain Hose| 1 pc
| Window Kit Brace| 1 pc()| | Drain Hose Adaptor (only for heat pump model)| 1 pc()
| Sliding Window Adapter–Front| 1 pc()| | Power Cord Buckle (only for cooling model)| 1 pc()
| Sliding Window Adapter–Rear| 1 pc()| | Remote Controller and Battery (only for remote control models)| 1 set
| Sliding Window Adapter–Air Divider| 1 pc(
)| | Heat pump hose insulation foam (optional)| 1 set()
| Foam Seal A (Adhesive)| 4 or 2pc| | 1 Screw ( on Exhaust adaptor)| 1 pc(
)
| Foam Seal B (Adhesive)| 2 pc| | Foam Seal C (Non-adhesive)| 2 or 1pc

Window Installation Kit

1. For Hung Window types only
Insert the Air Exhaust Adapter into the exhaust of the hose (the circular opening) for optimal performance. Rotate the adapter clockwise until the locking tabs click and it no longer rotates.
Skip this step if installing into a horizontal sliding window. The Air Exhaust adapter may interfere with some window screens, and can be removed if desired (Please note this may slightly decrease performance).
CH-STLS-14AC Mobile Air Conditioner Local Air Conditioner - For Hung Window
types only 2. Preparing the adjustable window slider

  1. Depending on the size of your window, adjust the size of the window slider.Use the combination of panels that best fits your window opening.
    CH-STLS-14AC Mobile Air Conditioner Local Air Conditioner - adjustable
window slider

  2. If the length of the window requires two or more window sliders, use the bolt to fasten the window sliders once they are adjusted to the proper length.

  3. If installing in a sliding window, bolts should be installed on both sides of the window sliders.

TYPE ONE
Three Window Sliders with side holes
Two Window Sliders without side hole Use the table below to determine what combinationof Window Sliders is correct for your window
Table 1(For some units)

window slider window dimension(mm) window dimension (inch)
a+b 484 ~
b+c 592 ~
a+b+c 696 ~
b+e 802 ~
a+b+e 896 ~
a+b+c+d 998 ~
a+b+c+d+e 1210 ~

CH-STLS-14AC Mobile Air Conditioner Local Air Conditioner - Three Window
Sliders 3 TYPE TWO

Three Window Sliders with side holes                           CH-STLS-14AC
Mobile Air Conditioner Local Air Conditioner - Three Window Sliders
4Two Window Sliders without side hole CH-STLS-14AC Mobile Air Conditioner Local Air
Conditioner - Three Window Sliders 5Use the table below to determine what combination of Window Sliders is correct for your window
Table 2(For some units)

window slider window dimension (mm) window dimension (inch)
a+b 675 ~

CH-STLS-14AC Mobile Air Conditioner Local Air Conditioner - Three Window
Sliders 6 3. Applying insulation to the window slider(For some units)
After assembling the window slider to your proper dimension, cut and apply the foam insulation sheets to the exterior side of the window slider. CH-STLS-
14AC Mobile Air Conditioner Local Air Conditioner - window
slider

NOTICE
Once the Exhaust Hose assembly and Adjustable Window Slider are prepared, choose from one of the following two installation methods.

Installation
Type 1: Hung window installation

  1. Cut the adhesive foam seal A and B strips to the proper lengths, and attach them to the window sash and frame as shown Fig.1. CH-STLS-14AC Mobile Air Conditioner Local Air Conditioner - Fig.1
  2. Insert the window slider assembly into the window track. If the hose opening is covered by the lip of the window frame, rotate the panel so the thicker side faces the window frame.(see Fig.2) CH-STLS-14AC Mobile Air Conditioner Local Air Conditioner - Fig 2For some units, attach the Window Kit Brace to the back of the hose panel to brace against the window so the window slider panels do not lean inward. (see Fig.3)CH-STLS-14AC Mobile Air Conditioner Local Air Conditioner - Fig 3
  3. Cut the non-adhesive foam seal C strip to match the width of the window. Insert the seal between the glass and the window frame to prevent air and insects from getting into the room.(see Fig.4)CH-STLS-14AC Mobile Air Conditioner Local Air Conditioner - Fig 4
  4. If desired, install the security bracket with screws as shown.(see Fig.5)  CH-STLS-14AC Mobile Air Conditioner Local Air Conditioner - Fig 5
  5.  Attach the hose to the window slider panel by inserting the end of the hose into the opening on the slider.(see Fig.6)CH-STLS-14AC Mobile Air Conditioner Local Air Conditioner - Fig 6

Type 2: Sliding window Installation (Optional)

  1. Cut the adhesive foam seal A and B strips to the proper lengths, and attach them to the window sash and frame as shown.(see Fig.7)CH-STLS-14AC Mobile Air Conditioner Local Air Conditioner - Fig 7

  2. Assembling the Sliding Window Adapter (Only needed for Sliding Window applications):
    Align both halves of the sliding window adapter and connect them. Then, attach the air divider to the newly formed window adapter on the outdoor side. The fully assembled adapter should look like the image at the left.(see Fig.8 )CH-STLS-14AC Mobile Air Conditioner Local Air Conditioner - Fig
8

  3. Insert the window slider assembly into the window track. If the hose opening is covered by the window frame, rotate the panel so the thicker side faces the window frame. (see Fig.9)
    CH-STLS-14AC Mobile Air Conditioner Local Air Conditioner - Fig
9For some units, attach the Window Kit Braceto the back of the hose panel to brace against the window so the window slider panels do not lean inward.(see Fig.10)CH-STLS-14AC Mobile Air
Conditioner Local Air Conditioner - Fig 10

  4. Be sure bolts are installed in both sides of the window slider for improved rigidity.

  5. Cut the non-adhesive foam seal C strip to match the window height. Insert the foam seal between the glass and the window frame to prevent air and insects from getting into the room.(see Fig.11)CH-STLS-14AC Mobile Air Conditioner Local Air Conditioner - Fig 11

  6. If desired, install the security bracket with 2 screws as shown.(see Fig.12)
    CH-STLS-14AC Mobile Air Conditioner Local Air Conditioner - Fig
12

  7. Attach the Sliding Window Adapter to the hose by lining up the circles on the adapter the hose. Insert the window slider adapter into the hole of the window slider.(see Fig.13)CH-STLS-14AC Mobile Air Conditioner Local Air Conditioner - Fig 13

HEAT PUMP HOSE INSULATION FOAM(only for heat pump mode)
NOTE: When the unit is at heat mode, the heat pump hose insulation foam must be fixed in the hose of unit.
If you are experiencing condensation on the outer section of the hose during heating operation, apply the included heat pump insulation foam to the outside of the hose. Use the included zip ties to secure the foam around the hose. NOTICE
To ensure proper function, DO NOT overextend or bend the hose. Make sure that there are no objects within 20in (~500mm) of the inlet and outlet hose. All illustrations in this manual are for explanation purposes only, your air conditioner may be slightly different than shown.CH-STLS-14AC Mobile Air
Conditioner Local Air Conditioner - Fig 15

Operating Instructions

Control Panel Features
NOTE: The following control panels are for explanation purpose only. The control panel of the unit you purchased may be slightly different according to the models. Your machine may not contain some indicators or buttons. The actual shape shall prevail. CH-STLS-14AC Mobile Air Conditioner Local Air
Conditioner - Control Panel Features

Power Button

  • Powers the unit on and off.

Swing Button

  • Used to initiate the Auto Swing feature. When the operation is ON, pressing the SWING button can stop the louver at the desired angle.

Wireless connection feature(On some models)
The swing button is also used to initiate the wireless connection mode.For the first time to initiate the wireless connection mode, power on the air conditioner then press the SWING button for 3 seconds.
The LED DISPLAY will show ‘AP’ to indicate the unit is in wireless connection mode.
Refer to the app connection instructions to finish the connection process.If the connection is successful, the unit will exit wireless connection mode and illuminate the wireless LED. If the connection fails, the unit will exit wireless connection mode automatically after 8 minutes and the wireless LED does not illuminate.
NOTE: The wireless connection process must be completed within 8 minutes after entering the wireless connection mode.
When you restart the Wireless function, it may take a period of time to connect to the network automatically.
Timer Button

  • Used to initiate the AUTO ON start time and AUTO OFF stop time program. The timer on or off light will illuminate depending on the selected setting.

Mode Button

  • Selects the desired operating mode. Each time you press the button, a mode is selected in a sequence that goes from AUTO, COOL, DRY, FAN and HEAT (Heat models only). The mode light illuminates and indicates the selected mode.

Up ( ) and Down ( ) Buttons

  • Used to increase/decrease temperature settings in 1° increments in a range of 60°F/16°C to 86°F/30°C or the TIMER setting in a range of 0 ~ 24hrs.
  • To change between °F or °C, simultaneously press and hold the Up and Down buttons for 3 seconds.

Fan Button/Continuous fan(On some models) button

  • Controls the fan speed. Press to control the fan speed in four steps – LOW, MID, HIGH and AUTO. The selected fan speed light will illuminate.

NOTE: Applicable to models with the Constant Fan feature. In COOL or DRY mode, press the Fan button for 3 seconds to turn on or off the constant fan function.
When the function is turned on, the constant fan light will illuminate, indicating the fan will run constantly. When the function is turned off, the constant fan light will go out, indicating that the fan will stop when the compressor stops.
Sleep Button

  • Used to initiate the SLEEP operation.
  • Pressing this button will increase (during cooling operation) or decrease (during heating operation, applicable models) 2°F/1°C after 30 minutes. The temperature will again increase (cooling) or decrease (heating) by another 2°F/1°C after an additional 30 minutes. This new temperature will be maintained for 7 hours before returning to the originally selected temperature. This ends the Sleep mode and the unit will continue to operate as originally programmed.
  • Press SLEEP button for 3 seconds to initiate the filter feature.This feature is a reminder to clean the Air Filter for more efficient operation. The LED(the light above the button) will illuminate after 250 hours of operation.

ION feature(on some models)

  • Press SWING button and TIME button at the same time for 3 seconds to initiate ION feature and the ION light illumiantes, the LED DISPLAY shows ‘On’ for 3 seconds for some units. The ion generatoris energized and will help to purify the air inside. Press it for 3 seconds again to stop the ION feature and the ION light turn dark, the LED DISPLAY shows ‘OF’ for 3 seconds for some units.

UV feature(on some models)

  • Press SWING button and TIME button at the same time for 3 seconds to initiate UV-C lamp feature and the UV light illumiantes, the LED DISPLAY shows ‘On’ for 3 seconds for some units. The UV-C lamp feature will help to purify the air inside. Press it for 3 seconds again to stop the UV-C lamp feature and the UV light turn dark, the LED DISPLAY shows ‘OF’ for 3 seconds for some units.

LED Display

  • Shows the set temperature in °F (Degrees Fahrenheit)(“°F” no display for some models) or °C (Degrees Celsius) and the Auto-timer settings. While on DRY and FAN modes, it shows the room temperature.
  • Shows Error codes and protection code:

The unit may stop operation or continue to run safely. If the error codes appear, wait for about 10 minutes. The problem may resolve itself. If not, disconnect the power, then connect it again. Turn the unit on. If the problem persists, disconnect the power and contact your nearest customer service center. Error code appears andbegins with the  letters as the following in the window display of indoor unit:EH(xx), EL(xx), EC(xx), PH(xx), PL(xx), PC(xx) P1-Bottom tray is full–Connect the drain hose and drain the collected water away.If protection repeats,call for service.
Note: When one of the above malfunctions occurs, turn off the unit, and check for any obstructions. Restart the unit, if the malfunction is still present, turn off the unit and unplug the power cord. Contact the manufacturer or its service agents or a similar qualified person for service.
COOL operation

  • Press the “MODE” button until the “COOL” indicator light comes on.
  • Press the ADJUST buttons “UP” or “DOWN” to select your desired room temperature. The temperature can be set within a range of 16°C/60°F to 30°C/86°F.
  • Press the “FAN SPEED” button to choose the fan speed.

FAN operation

  • Press the “MODE” button until the”FAN ” indicator light comes on.
  • Press the “FAN SPEED” button to choose the fan speed. The temperature can not be adjusted.

DRY operation

  • Press the “MODE” button until the “DRY” indicator light comes on.
  • Under this mode, you cannot select a fan speed. The fan motor operates at AUTO speed.
  • Keep windows and doors closed for the best dehumidifying effect.

AUTO operation

  • When you set the air conditioner in AUTO mode, it will automatically select cooling, heating(cooling only models without), or fan only operation depending on what temperature you have selected and the room temperature.
  • The air conditioner will control room temperature automatically round the temperature point set by you.
  • Under AUTO mode, you can not select the fan speed.

HEAT operation(cooling only models without)

  • Press the “MODE” button until the “HEAT” indicator light comes on.
  • Press the ADJUST buttons “UP” or ” DOWN” to select your desired room temperature. The temperature can be set within a range of 16°C/60°F to 30°C/86°F.
  • Press the “FAN SPEED” button to choose the fan speed.

TIMER operation

  • When the unit is on, press the Timer button will initiate the Auto-off stop program, the TIMER OFF indicator light illuminates. Press the UP or down button to select the desired time. Press the TIMER button again within 5 seconds, the Auto-on start program is initiated. And the TIMER ON indicator light illuminates. Press the up or down button to select the desired Auto-on start time.
  • When the unit is off, press the Timer button to initiate the Auto-on start program, press it again within 5 seconds will initiate the Auto-off stop program.
  • Press or hold the UP or DOWN button to change the Auto time by 0.5 hour increments, up to 10 hours, then at 1 hour increments up to 24 hours. The control will count down the time remaining until start.
  • The system will automatically revert back to display the previous temperature setting if there is no operation in a 5 seconds period.
  • Turning the unit ON or OFF at any time or adjusting the timer setting to 0.0 will cancel the Auto Start/Stop timer program.

Other features
TEMP SENSING feature(On some models)
NOTE:This feature can be activated from the remote control ONLY. There is no indicator light on the control panel. The remote control serves as a remote thermostat allowing for the precise temperature control at its location.
To activate the Temp Sensing feature, point the remote control towards the unit and press the I SENSE button. The remote control will send this signal to the  air conditioner until press the I SENSE button again.
If the unit does not receive the Temp Sensing signal during any 7 minutes interval, the unit will exit the Temp Sensing mode.
NOTE: This feature is unavailabe under FAN or DRY mode.

AUTO-RESTART
If the unit breaks off unexpectedly due to the power cut, it will restart with the previous function setting automatically when the power resumes.
WAIT 3 MINUTES BEFORE RESUMING OPERATION
After the unit has stopped, it can not be restarted operation in the first 3 minutes. This is to protect the unit. Operation will automatically start after 3 minutes.
AIR FLOW DIRECTION ADJUSTMENT
The louver can be adjusted automatically. Adjust the air flow direction automatically:

  • When the Power is ON, the louver opens fully.
  • Press the SWING button on the panel or remote controller to initiate the Auto swing feature. The louver willl swing up and down automatically.
  • Please do not adjust the louver manually.

Water drainage

  • During dehumidifying modes, remove the upper drain plug from the back of the unit, install the drain hose. For the models without drain connector, just attach the drain hose to the hole. Place the open end of the hose directly over the drain area in your  basement floor.CH-STLS-14AC Mobile Air Conditioner Local Air Conditioner - Water drainage

Water drainage(For Heating Mode)
While operating in heat pump mode, the unit will produce condensate that must be drained. You must install the drain hose when operating in heat mode. To install the drain hose, remove the plug from the drain port and attach the included hose. The universal drain adaptor can be attached to the end of the included hose. A 3/4” hose (not included) can be attached to the adaptor if a longer hose length is required. Place the end of the hose in the drain area you are using.
Note: Make sure the drain hose is lower than the bottom tray drain outlet.
CH-STLS-14AC Mobile Air Conditioner Local Air Conditioner - Water drainage
1 NOTE: Make sure the hose is secure so there are no leaks. Direct the hose toward the drain, making sure that there are no kinks that will stop the warter flowing. Place the end of the hose into the drain and make sure the end of the hose is down to let the water flow smoothly.(See Figs with . √ Do never let it up.(See Figs with ).X When the continuous drain hose is not used, ensure that the corresponding drain plug and knob are installed firmly to prevent leakage.CH-
STLS-14AC Mobile Air Conditioner Local Air Conditioner - Water drainage
2When the water level of the bottom tray reaches a predetermined level, the unit beeps 8 times, the digital display area shows “P1” . At this time the air conditioning/dehumidification process will immediately stop. However, the fan motor will continue to  perate(this is normal). Carefully move the unit to a drain location, remove the bottom drain plug and let the water drain away. Reinstall the bottom drain plug and restart the machine until the “P1” symbol disappears.  If the error repeats, call for service. NOTE: Be sure to reinstall the bottom drain plug firmly to prevent leakage before using the unit.

Maintenance

Safety Precautions

  • Always unplug the unit before cleaning or servicing.
  • DO NOT use flammable liquids or chemicals to clean the unit.
  • DO NOT wash the unit under running water. Doing so causes electrical danger.
  • DO NOT operate the machine if the power supply was damaged during cleaning. A damaged power cord must be replaced with a new cord from the manufacturer.

Air Filter Cleaning
CH-STLS-14AC Mobile Air Conditioner Local Air Conditioner - Air Filter
CleaningMaintenance Tips

  • Be sure to clean the air filter every 2 weeks for optimal performance.
  • The water collection tray should be drained immediately after P1 error occurs, and before storage to prevent mold.
  • In households with animals, you will have to periodically wipe down the grill to prevent blocked airflow due to animal hair.

CAUTION
DO NOT operate the unit without filter because dirt and lint will clog it and reduce performance.
Unit Cleaning
Clean the unit using a damp, lint-free cloth and mild detergent. Dry the unit with a dry, lint-free cloth.
Store the unit when not in use

  • Drain the unit’s water collection tray according to the instructions in the following section.
  • Run the appliance on FAN mode for 12 hours in a warm room to dry it and prevent mold.
  • Turn off the appliance and unplug it.
  • Clean the air filter according to the instructions in the previous section. Reinstall the clean, dry filter before storing.
  • Remove the batteries from the remote control.

Note: Be sure to store the unit in a cool, dark place. Exposure to direct sunshine or extreme heat can shorten the lifespan of the unit.
Note: The cabinet and front may be dusted with an oil-free cloth or washed with a cloth dampened in a solution of warm water and mildliquid dishwashing detergent. Rinse thoroughly and wipe dry. Never use harsh cleansers, wax or polish on the cabinet front. Be sure to wring excess water from the cloth before wiping around the controls. Excess water in or around the controls may cause damage to the unit.

Troubleshooting Tips

Solution

Problem Possible Causes Solution
Unit does not turn on when pressing ON/OFF button P1 Protection Code The

Water Collection Tray is full. Turn off the unit, drain the water from the Water Collection Tray and restart the unit.
In COOL mode: room temperature is lower than the set temperature| Reset the temperature
Unit does not cool well| The air filter is blocked with dust or animal hair| Turn off the unit and clean the filter according to instructions
Exhaust hose is not connected or is blocked| Turn off the unit, disconnect the hose, check for blockage and reconnect the hose
The unit is low on refrigerant| Call a service technician to inspect the unit and top off refrigerant
Temperature setting is too high| Decrease the set temperature
The windows and doors in the room are open| Make sure all windows and doors are closed
The room area is too large| Double-check the cooling area
There are heat sources inside the room| Remove the heat sources if possible
The unit is noisy and vibrates too much| The ground is not level The air filter is blocked with dust or animal hair| Place the unit on a flat, level surface Turn off the unit and clean the filter according to instructions
The unit makes a gurgling sound| This sound is caused by the flow of refrigerant inside the unit| This is normal

The warranty should be registered on our website www.cooperandhunter.com
Replacement 2 year Warranty

PRODUCT REGISTRATION:
Model No.: ____
Serial No.: ____
Date of Installation: __
Owner Name: ____
Address of Installation:

Place Of Purchase:
Date of Purchase:

Visit our website for:

  • Product Information
  • Warranty Registration
  • Installation Manual
  • User Guides and more

www.cooperandhunter.us

Visit our YouTube Channel for:

  • Instructional Videos
  • Tutorials and How Tos
  • Product Introductions
  • Advertisement and more

www.youtube.com/cooperandhunterusa

C&H distributor (hereinafter “Company”) warrants this product against failure due to defect in materials or workmanship under normal use and maintenance as follows. All warranty periods begin on the date of original installation. If the date cannot be verified, the warranty period begins one hundred twenty (120) days from date of manufacture. Damage resulting from failure to use, install or maintain the product in a manner consistent with our/ manufacturer’s recommendations shall render the warranty void.

This warranty covers all defects in workmanship and the internal parts contained in this product for 2 years from the date of purchase. Warranty covers the original purchaser of this product only.
The original purchase receipt must be presented in order to obtain the warranty. To claim the warranty, the customer should call our technical support to troubleshoot first, but if there problem cannot be fixed, Cooper&Hunter will replace any unit found to be defective in material or workmanship during two years after purchase for the same make and model. This is a one-time replacement warranty. Defective unit must be returned to the original store of purchase or to Cooper&Hunter office: 3550 NW 113th Ct, Doral, FL 33178.
THIS WARRANTY COVERS PRODUCTS WITHIN THE CONTINENTAL UNITED STATES.
LIMITATIONS OF WARRANTIES: ALL IMPLIED WARRANTIES AND/OR CONDITIONS (INCLUDING IMPLIED WARRANTIES OR CONDITIONS OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR USE OR PURPOSE) ARE LIMITED TO THE  DURATION
OF THIS LIMITED WARRANTY. SOME STATES OR PROVINCES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY OR CONDITION LASTS, SO THE ABOVE MAY NOT APPLY TO YOU. THE EXPRESS WARRANTIES MADE IN  THIS WARRANTY ARE EXCLUSIVE AND MAY NOT BE ALTERED, ENLARGED, OR CHANGED BY ANY DISTRIBUTOR, DEALER, OR OTHER PERSON, WHATSOEVER.

THIS WARRANTY DOES NOT COVER:

  • Damages in shipping
  • Damages caused by improper installation
  • Damages as the result of not using product in accordance with provided instructions
  • Damage from services performed by an unauthorized service center
  • Disposal fees
  • Any performance issues that fall outside of the 2 years warranty
  • Damages incurred to the home during installation, including but not limited to floors, walls, and furniture.
  • Rust on interior or exterior of unit.
  • Products with the product labels/serial numbers that have been removed or altered.
  • Products used in a commercial setting.
  • Display models.

NOTE: Some states do not allow the exclusion or limitation of incidental or consequential damages. This limitation or exclusion may not apply to you.
Design and specifications are subject to change without prior notice for product improvement.
Consult with the sales agency or manufacturer for details.

IMPORTANT NOTE:
Read the manual carefully before connecting your Smart kit(Wireless module).
Make sure to save this manual for future reference.Illustrations in this manual are for explanatory purposes.The actual shape shall prevail.

SPECIFICATION

Unit model:SS
Standard: IEEE 802. 11b/g/n
Antenna Type: Printed PCB Antenna
Frequency Band: 2400-2483.5MHz
Operation Temperature:0 C~45 C/32 F~113
F Operation Humidity: 10%~85%
Power Input: DC 5V/300mA
Maximum TX Power: <20dBm
NOTE:
Company will not be liable for any issues and problems caused by Internet, Wi- Fi/Wireless Router and Smart Devices. Please contact the original provider to get further help.

DOWNLOAD AND INSTALL APP

CAUTION: Use the following QR code t nla APP. It is totally different rm the QR code packed with unit.

|
---|---
https://play.google.com/store/apps/details?id=com.midea.aircondition| https://itunes.apple.com/us/app/nethome- plus/id1008001920?l=zh&ls=1&mt=8

  • Android Phone users: scan Android QR code or go to google play, search App and download it.
  • iOS users: scan iOS QR code or go to APP Store, search app and download it.

PREPARATION

  • Please ensure your mobile device is connected to Wi-Fi/Wireless router. Also, the Wi-Fi/Wireless router has already connected to Internet before doing user registration and network configuration.
  • Make sure your mobile device has already been connected to the Wi-Fi/Wireless network which you want to use. Also, you need to forget other irrelevant Wi-Fi/Wireless network in case it influences your configuration process.

CREATE ACCOUNT

Reminder: When you registerin to use app, read and agree t the Data Privacy Notice.CH-STLS-14AC Mobile Air Conditioner Local Air Conditioner -
Data Privacy

NETWORK CONFIGURATION

Cautions
It is necessary to forget any other around network and make sure the Android or iOS device just connect to the Wi-Fi/Wireless network you want to configure.
Make sure the Android or iOS device Wi-Fi/Wireless function works well and can be connected back to your original Wi-Fi/Wireless network automatically.
Kindly reminder:
User must finish all the steps in 8 minutes after powering on AC, otherwise you need to power on it again.
Using Android or iOS device to do network configuration
Make sure your mobile device has already been connected to the Wi-Fi/Wireless network which you want to use. Also, you need to forget other irrelevant Wi- Fi/Wireless network in case it influences your configuration process.
Disconnect the power supply of AC
Connect the power supply of AC, activate the AP mode (The pictures in the manual are for explanation purpose only. Your machine may be slightly different.Read the WIRELESS MODE IN USER’S MANUAL or INSTRUCTION MANUAL for detailed operations.).
When AP appears in the display, It means that the AC WIRELESS has already entered into AP Mode. User can do the next step configuration.
Note:There are two ways to finish the network configuration:
Network configuration by Bluetooth scan
Network configuration by select appliance type

Network configuration by Bluetooth scan
Note: Make sure the bluetooth of your mobile device is working. CH-STLS-14AC Mobile Air Conditioner Local Air Conditioner - Data Privacy
1

CH-STLS-14AC Mobile Air Conditioner Local Air Conditioner - Data Privacy
2 Network configuration by select appliance type : CH-STLS-14AC Mobile Air Conditioner Local Air
Conditioner - Data Privacy 3 CH-STLS-14AC Mobile Air Conditioner Local Air Conditioner - Data Privacy
4 NOTE: Steps 3 and 4 are applicable to Android system only. iOS system does not need these two steps.
CH-STLS-14AC Mobile Air Conditioner Local Air Conditioner - Data Privacy
5

NOTE:

  • When finishing network configuration, te a will display success cue words on the screen. Due to different internet environments, it is possible that the device status still display  “offline”.
  • If this situation occurs, it is necessary to pull and refresh the device list on the a and make sure the device status becomes “online” . Alternatively, user can turn off the AC power and turn on it again, the device status will become “online” after few minutes.

HOW TO USE APP

Please ensure both your mobile device and air conditioner are connected to the Internet before using app to control the air conditioner via internet, please follow the next steps:CH-STLS-14AC Mobile Air Conditioner Local Air
Conditioner - Data Privacy 6

NOTE:
Not all the functions of the a are is available on air conditioner. For example: ECO, Turbo, Swing function, please check the user manual to find more information.

SPECIAL FUNCTIONS

Schedule
Weekly, user can make an appointment to turn on or off AC on specific time. User also can choose circulation to keep the AC under schedule control every week.CH-STLS-14AC Mobile Air Conditioner Local Air Conditioner - Data
Privacy 7

Sleep
User can customize their own comfortable sleep by setting target temperature. CH-STLS-14AC Mobile Air Conditioner Local Air Conditioner -
Data Privacy 8Check
User can simply check the AC running status with this function. When finishing this procedure, it can display the normal items, abnormal items, and detail information. CH-STLS-14AC Mobile Air Conditioner Local Air Conditioner -
Data Privacy 9

Share Device
The air conditioner can be controlled by multile-users at the same time by Share Device function.  CH-STLS-14AC Mobile Air Conditioner Local Air
Conditioner - Data Privacy 10 CH-STLS-14AC Mobile Air Conditioner Local Air Conditioner -
Data Privacy 11

APP DECLARATION

Applicable system:IOS,Android.

  1. APP can not support the latest software version of Android and IOS system.1

  2. Due to special situations tat may be occur,we explicitly claim below: Not all of the Android and IOS system are compatible with te a. We will not be responsible for any issue as a result of the incompatibility.
    Wireless safety strategy
    Smart kit only support WPA-PSK/WPA2-PSK encryption and none encryption.
    WPA-PSK/WPA2-PSK encryption is recommended.
    Cautions
    Due to different network situations,control process may return time-out sometimes. If this situation occurs,the display between board and app may not be the same.
    Smart Phone camera needs to be 5 million pixels or above to scan QR code.

  3. Due to different network situations sometimes,request time-out could happen,thus,it is necessary to do network configuration again.

  4. The a system is subject to update without prior notice for product function improvement.
    The actual network configuration process may be slightly different from the manual, the actual process shall prevail.

  5. Please Check the service ebsite or more information.
    Hereby, we declare that this AC is in compliance with the essential requirements and other relevant provisions of RE Directive 2014/53/EU. A copy of the full DoC is attached.

NOTE :
All the illustrations in the manual are for explanation purpose only. Your unit may be slightly different. The actual shape shall prevail.

Declaration of conformity

CONTAINS FCC ID: 2ADQOMDNA21
CONTAINS IC : 12575A-MDNA21
This device complies with Part 15 of the FCC Rules and it contains licence- exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic
Development Canada’s licence-exempt RSS(s).
Operation is subject to the following two conditions:
This device may not cause interference; and
This device must accept any interference, including interference that may cause undesired operation of the device.
Only operate the device in accordance with the instructions supplied. Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.This device complies with FCC radiation exposure limits set forth for an uncontrolled environment. In order to avoid the possibility of exceeding the FCC radio frequency exposure limits, human proximity to the antenna shall not be less than 20cm (8 inches) during normal operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
–Reorient or relocate the receiving antenna.
–Increase the separation between the equipment and receiver.
–Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
–Consult the dealer or an experienced radio/TV technician for help.
Company will not be liable for any issues and problems caused by Internet, Wi- Fi/ Wireless Router and Smart Devices. Please contact the original provider to get further help.
The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details. Any updates to the manual will be uploaded to the service website, please check for the latest version.

CP001UI-PTTY

Documents / Resources

| CH CH-STLS-14AC Mobile Air Conditioner Local Air Conditioner [pdf] Owner's Manual
CH-STLS-14AC Mobile Air Conditioner Local Air Conditioner, CH-STLS-14AC, Mobile Air Conditioner Local Air Conditioner, Air Conditioner Local Air Conditioner, Local Air Conditioner, Air Conditioner, Conditioner
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals