INTERMATIC KM2 Series In Wall Timers Instruction Manual
- June 16, 2024
- Intermatic
Table of Contents
INTERMATIC KM2 Series In Wall Timers
Product Information
Specifications
- Clock Input: 120VAC, 60Hz
- Switch Rating: SPST and SPDT
- 20A @ 120VAC, 60Hz
- 1HP @ 120VAC
- Wiring Connections: Three #14AWG lead wires
Product Features
- 24-hour time switch program
- Captive trippers with 20-minute switching interval
- Reliable synchronous timer motor
- SPST or SPDT 20A, 1HP @ 125V switch
- OFF/ON/AUTO manual switch
- Mounts to standard electrical wall boxes
- Available with various wall plate options
- Three-way (SPDT) switch available
- UL and Canadian UL Listed
Product Usage Instructions
Installation Instructions
-
1. Check the input and output ratings on unit to make sure this product is suitable for your application.
WARNING: To avoid fire, shock, or death, turn off power at circuit breaker and test that power is off before wiring.
- Wire in accordance with all national and local electrical codes (see wiring diagrams below).
- Verify that all connections are secure. Double check all twist-on wire connectors.
- Mount timer into wall box using the supplied screws.
- Mount wall plate onto timer using the supplied screws.
Programming Instructions
The timer dial contains 72 trippers, each representing a 20 minute timer
interval.
-
1. Setting the clock time – Rotate the dial gradually clockwise until the current time is aligned with the triangle marker at the 3 o’clock position.
NOTICE! Do not rotate the dial counter-clockwise. Doing so will damage the timer.
FAQ
Where can I find warranty information for this product?
This warranty service is available by either (a) returning the product to
the dealer from whom the unit was purchased, or (b) completing a warranty
claim online at www.intermatic.com. This warranty
is made by: Intermatic Incorporated, Customer Service 7777 Winn Rd. Spring
Grove, Illinois 60081-9698. For warranty service go to:
www.intermatic.com or call
815-675-7000.
What are the available ordering options for this product?
Description | Switch |
---|---|
single gang | 20A, SPST |
three-way single gang | 20A, SPDT |
2-gang/toggle opening | 20A, SPST |
2-gang/receptacle opening | 20A, SPST |
2-gang/decorator opening | 20A, SPST |
3-gang/decorator opening | 20A, SPST |
3-gang/toggle openings | 20A, SPST |
4-gang/toggle openings | 20A, SPST |
KM2 Series In-Wall Timers
Replaces standard wall switch to provide automatic control of out-door or
indoor lighting, fans, pumps, office machines, and other types of circuits.
Captive trippers are easy to set, can’t be lost. 72 trippers provide up to 36
ON/OFF events in 24 hour period. OFF/ON/AUTO over-ride switch provides
continuous ON or OFF positions. UL Listed. Easy wiring and installation.
FEATURES
- 24 hour time switch program
- Captive trippers with 20 minute switching interval
- Reliable synchronous timer motor
- SPST or SPDT 20A, 1HP @ 125V switch
- OFF/ON/AUTO manual switch
- Mounts to standard electrical wall boxes
- Available with 1, 2, 3, or 4-gang wall plates with toggle switch openings, 2-gang or 3-gang wall plates with decorator opening or 2-gang wall plate with duplex receptacle opening.
- Three way (SPDT) switch available
- UL and Canadian UL Listed
SPECIFICATIONS
Clock Input: 120VAC, 60Hz
Switch Rating: SPST and SPDT 20A @ 120VAC, 60Hz 1HP @ 120VAC
Environmental Ratings:
- Operating Temperature Range: –40°F to 180°F (–40°C to 85°C)
- Operating Humidity : 0 – 95% RH, non-condensing
- Wiring Connections : Three #14AWG lead wires
Installation Instructions
- Check the input and output ratings on unit to make sure this product is suitable for your application.
- WARNING : To avoid fire, shock or death, turn off power at circuit breaker and test that power is off before wiring.
- Wire in accordance with all national and local elec-trical codes (see wiring diagrams below).
- Verify that all connections are secure. Double check all twist-on wire connectors.
- Mount timer into wall box using the supplied screws.
- Mount wall plate onto timer using the supplied screws.
Programming Instructions
The timer dial contains 72 trippers, each representing a 20 minute timer
interval.
ORDERING DATA
24 Hour Model|
Description
|
Switch
KM2ST-1G| single gang| 20A, SPST
KM2STU-1G| three-way single gang| 20A, SPDT
KM2ST-2G| 2-gang/toggle opening| 20A, SPST
KM2ST-2R| 2-gang/receptacle opening| 20A, SPST
KM2ST-2D| 2-gang/decorator opening| 20A, SPST
KM2ST-3D| 3-gang/decorator opening| 20A, SPST
KM2ST-3G| 3-gang/toggle openings| 20A, SPST
KM2ST-4G| 4-gang/toggle openings| 20A, SPST
WARNING
- To avoid fire, shock or death, turn off power at circuit breaker and test that power is off before wiring or servicing.
- Read instructions completely before installation and retain for future reference.
- Observe all national and local electrical codes.
- Alterations or modifications to the device will void the warranty.
Setting the clock time
Rotate the dial gradually clockwise until the current time is aligned with the
tri-angle marker at the 3 o’clock position.
NOTICE! Do not rotate the dial counter-clockwise. Doing so will damage the timer.
Programming the timer
Move the slide switch to the right AUTO position. Move the tripper,
correspond-ing to the start of the desired ON time, inward. Move each adjacent
tripper inward until the desired OFF time is reached. Repeat for all desired
ON/OFF cycles.
Manual Override Instructions
The slide switch provides manual operation of the load, overriding the timer
programming. If set to the OFF position, the load will be continuously off. If
set to the ON position the load will be continuously on. For automatic on/off
function, set the switch to the AUTO position.
Wiring Diagrams
Standard Installation
3-Way Installation
LIMITED ONE-YEAR WARRANTY
If within the warranty period specified, this product fails due to a defect in material or workmanship, Intermatic Incorporated will repair or replace it, at its sole option, free of charge. This warranty is extended to the original purchaser only and is not transferable.
This warranty does not apply to:
- (a) damage to units caused by accident, dropping or abuse in handling, acts of God or any negligent use;
- (b) units that have been subject to unauthorized repair, opened, taken apart or otherwise modified;
- (c) units not used by instructions;
- (d) damages exceeding the cost of the product;
- (e) sealed lamps and/or lamp bulbs, LED, and batteries;
- (f) the finish on any portion of the product, such as surface and/or weathering, as this is considered normal wear and tear;
- (g) transit damage, initial installation costs, removal costs, or reinstallation costs.
INTERMATIC INCORPORATED WILL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS OR IMPLIED WARRANTIES. ALL IMPLIED WARRANTIES, INCLUDING THE WARRANTY OF MERCHANTABILITY AND THE WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY MODIFIED TO EXIST ONLY AS CONTAINED IN THIS LIMITED WARRANTY, AND SHALL BE OF THE SAME DURATION AS THE WARRANTY PERIOD STATED ABOVE. SOME STATES DO NOT ALLOW LIMITATIONS ON THE DURATION OF AN IMPLIED WARRANTY, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU.
This warranty service is available by either (a) returning the product to the dealer from whom the unit was purchased, or (b) completing a warranty claim online at www.intermatic.com.
This warranty is made by:
Intermatic Incorporated, Customer Service 7777 Winn Rd. Spring Grove, Illinois
60081-9698. For warranty service go to: http://www.intermatic.com or call
815-675-7000.
Distributed by: INTERMATIC INCORPORATED Spring Grove, IL 60081-9698 www.intermatic.com
http://waterheatertimer.org/Intermatic-timers-and-manuals.html#KM2
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>