FISHER PAYKEL DH9060 Heat Pump Condensing Dryer 9kg Installation Guide

June 15, 2024
Fisher & Paykel

FISHER PAYKEL - logo DH9060 Heat Pump Condensing Dryer 9kg
Installation Guide

DH9060 Heat Pump Condensing Dryer 9kg

FISHER PAYKEL DH9060 Heat Pump Condensing Dryer 9kg FABRIC CARE SOLUTION
DRYER ON PLINTH INSTALLATION
*DH9060, FM2060S1 and FM2060SG1 models
INSTALLATION GUIDE
NZ AU**

ACCESSING YOUR PRODUCT SPECIFICATIONS

FISHER PAYKEL DH9060 Heat Pump Condensing Dryer 9kg - qr
codehttp://fisherpaykel.com/install

For full product, cabinetry and service specifications, refer to the Planning Guide. To access the Planning Guide, scan the QR code or visit fisherpaykel.com/specify. Search by appliance type, product name or model code. FISHER PAYKEL DH9060 Heat Pump
Condensing Dryer 9kg - feager

PRIOR TO INSTALLATION

fisherpaykel.com/specify

  1. Ensure cabinetry and servicing specifications have been met and clearances have been considered. Refer to the Planning Guide for details.FISHER PAYKEL DH9060 Heat Pump Condensing Dryer 9kg - Ensure floor
  2. Ensure floor is level and clear and a finished return has been created.FISHER PAYKEL DH9060 Heat Pump Condensing Dryer 9kg - Ensure power
  3. Ensure power will remain accessible following install to allow access for any future product maintenance.
    Service holes should be smooth with grommets installed where required. Refer to the services section of the Planning Guide for more details.

UNPACK

FISHER PAYKEL DH9060 Heat Pump Condensing Dryer 9kg -
straps

  1. Cut the straps and the line printed on the top of the dryer carton. Lift to remove. Discard braces and corner posts. Remove any packaging and accessories from the drum and base packer. Dispose of packaging responsibly.FISHER PAYKEL DH9060 Heat Pump Condensing Dryer 9kg - straps1
  2. Cut the straps and tape to open the plinth carton from the top. Remove the EPS cap before lifting the plinth out. Set cardboard aside for later use. Ensure accessories are removed from the EPS cap before discarding EPS and rubber spacers responsibly.FISHER PAYKEL DH9060 Heat Pump Condensing Dryer 9kg - straps2
  3. Protect flooring before positioning dryer as close to the installation location as possible, ensuring enough working room is left available.

REVERSE DOOR (OPTIONAL)

The dryer door has reversible hinge and latch fittings and can be switched to open to the left or right, as needed.FISHER PAYKEL DH9060 Heat Pump
Condensing Dryer 9kg - REVERSE DOOR

  1. Unscrew hinge, remove door and place face down on a protected surface. Remove plugs (x 8) from inner door flanges, then remove screws. FISHER PAYKEL DH9060 Heat Pump Condensing Dryer 9kg - straps3

  2. Insert flat-head screwdriver in access slot to pry off inner door. Rotate door 180 degrees and fit back in place.
    Reattach screws, alternating between sides of the door. Replace plugs.FISHER
PAYKEL DH9060 Heat Pump Condensing Dryer 9kg - straps4

  3. On dryer, unscrew and remove latch cover to access latch.FISHER PAYKEL DH9060 Heat Pump Condensing Dryer 9kg - straps5

  4. Unscrew latch, and slide to remove.FISHER PAYKEL DH9060 Heat Pump Condensing Dryer 9kg - straps6

  5. Rotate latch and insert on opposite side of dryer. Secure with screw.
    Refit and secure latch cover with latch cover screws.FISHER PAYKEL DH9060
Heat Pump Condensing Dryer 9kg - Refit door

  6. Refit door hinge and secure with hinge screws.

LEVEL PLINTH

FISHER PAYKEL DH9060 Heat Pump Condensing Dryer 9kg - LEVEL
PLINTH

  1. Push the front of the plinth to open. Remove the divider before closing the drawer. FISHER PAYKEL DH9060 Heat Pump Condensing Dryer 9kg - LEVEL PLINTH 1
  2. Place the plinth in its final install location. Adjust the feet using the supplied spanner until the plinth is level front to back and corner to corner.FISHER PAYKEL DH9060 Heat Pump Condensing Dryer 9kg - LEVEL PLINTH 2
  3. Using the spanner provided, tighten the lock nuts against the base of the plinth to lock the feet in position.
    Recheck that the plinth is level, front to back and side to side. Once level, move the plinth to an accessible location to allow washer/dryer to be installed.

FIT DRYER TO PLINTH

FISHER PAYKEL DH9060 Heat Pump Condensing Dryer 9kg - FIT
DRYER

  1. Remove the four pre-fitted plinth brackets using a Phillips screwdriver. Set screws aside for later use.FISHER PAYKEL DH9060 Heat Pump Condensing Dryer 9kg - FIT DRYER 1

  2. Fit the two supplied front dryer brackets using the screws removed in step 1.FISHER PAYKEL DH9060 Heat Pump Condensing Dryer 9kg - FIT DRYER 3

  3. Lift the dryer onto the plinth and slot the front feet securely into the front plinth brackets. Ensure dryer and plinth are correctly aligned.FISHER PAYKEL DH9060 Heat Pump Condensing Dryer 9kg - LEVEL PLINTH3

  4. Remove the two screws from the front of the dryer and refit through the plinthFISHER PAYKEL DH9060 Heat Pump Condensing Dryer 9kg - LEVEL PLINTH4

  5. Fit the two supplied rear brackets to the plinth using the screws removed in step 1.
    Set aside any remaining screws.FISHER PAYKEL DH9060 Heat Pump Condensing
Dryer 9kg - LEVEL PLINTH5

  6. Using the two supplied long screws, secure the dryer to the plinth at the rear.

RAISE PRODUCT SET

FISHER PAYKEL DH9060 Heat Pump Condensing Dryer 9kg - PRODUCT
SET

  1. Partially roll stacked products into alcove and check alignment. To do this, use the supplied 6mm hex key, rotate clockwise to lower both sets of wheels via the adjustment screws.FISHER PAYKEL DH9060 Heat Pump Condensing Dryer 9kg - PRODUCT SET1
  2. Ensure all feet are raised off the floor before rolling the plinth to the final install location.FISHER PAYKEL DH9060 Heat Pump Condensing Dryer 9kg - PRODUCT SET2
  3. Using the supplied 6mm hex key, rotate counter-clockwise to raise both sets of wheels via the adjustment screws. Lower the wheels and remove product from alcove.

CONNECT CABLES AND HOSES

fisherpaykel.com/specify

  1. Refer to the Planning Guide for full service information.
    Supply: 220 – 240V, 50Hz Service: 10A
    Outlet: 3-prong grounding-type
    Supply: Hoses provided
    Pressure: 50KPa (7psi) – 1MPa (150psi). Min 6 litres/min.FISHER PAYKEL
DH9060 Heat Pump Condensing Dryer 9kg - CONNECT CABLES

  2. Optional:
    Fit the drain hose extension if dryer can be connected to a drain.FISHER
PAYKEL DH9060 Heat Pump Condensing Dryer 9kg - CONNECT CABLES
1

  3. Connect the angled end of the dryer cold hose to the dryer.
    The washer and dryer cold hoses can be swapped if necessary.FISHER PAYKEL
DH9060 Heat Pump Condensing Dryer 9kg - Ensure power2

  4. Turn off cold water tap for washer, and undo washer cold hose at tap end.FISHER PAYKEL DH9060 Heat Pump Condensing Dryer 9kg - Ensure power3

  5. Connect washer and dryer straight ends to the top of the supplied Y join.FISHER PAYKEL DH9060 Heat Pump Condensing Dryer 9kg - Ensure power4

  6. Connect the dryer straight hose to the bottom of the Y join.FISHER PAYKEL DH9060 Heat Pump Condensing Dryer 9kg - HOSES

  7. Partially push dryer and plinth into the alcove.FISHER PAYKEL DH9060 Heat Pump Condensing Dryer 9kg - HOSES1

  8. Route the power cables and hoses through service holes. Ensure power will remain accessible following install to allow access for any future product maintenance.FISHER PAYKEL DH9060 Heat Pump Condensing Dryer 9kg - HOSES2

  9. Connect the cold hose to cold water tap and turn tap on. If possible, recheck for leaks 24 hours after installation.FISHER PAYKEL DH9060 Heat Pump Condensing Dryer 9kg - HOSES3

  10. 10A. Standpipe Installations Route the drain hose through the guide and place into the standpipe.
    Ensure a maximum of 20mm of the hose rests in the standpipe.FISHER PAYKEL
DH9060 Heat Pump Condensing Dryer 9kg - Spigot
Installations10B. Spigot Installations
    Drill out blanking insert from the spigot.
    Route the drain hose through the guide and place into the spigot. Secure using a hose clamp.FISHER PAYKEL DH9060 Heat Pump Condensing Dryer 9kg -
HOSES4

  11. Connect the power cable and check product is powered on.

INSTALL DRYER

FISHER PAYKEL DH9060 Heat Pump Condensing Dryer 9kg - INSTALL
DRYER

  1. Push dryer into the alcove. Take care not to damage hoses or cords.FISHER PAYKEL DH9060 Heat Pump Condensing Dryer 9kg - INSTALL DRYER 1
  2. Turn the adjustment screw counter-clockwise to retract the wheels. Ensure the wheels are fully raised off the floor.FISHER PAYKEL DH9060 Heat Pump Condensing Dryer 9kg - INSTALL DRYER2
  3. Check alignment and ensure required clearances are maintained. Adjust as required.FISHER PAYKEL DH9060 Heat Pump Condensing Dryer 9kg - INSTALL DRYER3
  4. Once adjustment is complete, fit the plinth bolt hole covers.

FISHERPAYKEL.COM
© Fisher & Paykel Appliances 2023. All rights reserved.
The models shown in this guide may not be available in all markets and are subject to change at any time.
The product specifications in this guide apply to the specific products and models described at the date of issue. Under our policy of continuous product improvement, these specifications may change at any time.
For current details about model and specification availability in your country, please go to our website or contact your local Fisher & Paykel dealer.

FISHER PAYKEL - logo431987A 10.23

Documents / Resources

| FISHER PAYKEL DH9060 Heat Pump Condensing Dryer 9kg [pdf] Installation Guide
DH9060 Heat Pump Condensing Dryer 9kg, DH9060, Heat Pump Condensing Dryer 9kg, Condensing Dryer 9kg, Dryer 9kg
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Fisher & Paykel User Manuals

Related Manuals