TCS3 Solar Charge Controller

Thank you for purchasing the solar charge controller TCS3. Please confirm the voltage of the battery and the solar panel is in accordance with the working voltage of the controller (24V) before you use the controller. The TCS3 is specially designed for solar charge controlling and battery discharge controlling in automatic gate opener system. It is integrated with multiple safety protection for battery, such as: over charge protection and over discharge protection.
Capacity: 10 Amps

Wire connection

The battery is only charged by solar panel (the adapter is not used)

TCS3 Solar Charge Controller Wire Connection

Firstly connect the battery to the controller and then connect the solar panel to the “SOL” terminal of the controller. Connect the “BAT” terminal of Control Board of gate opener to the “LOAD” terminal of the controller by the extension cord as wiring diagram above. Don’t use the cord which is smaller than 0.75mm2 (18 AWG) when the length is longer than 22.5m (75’). The 2mm2 (14 AWG) or 3.3 mm2 (12 AWG) is strongly recommended for 30m (100’) or 45m (150’) extension distance. Please note the polarity of all the appliances while connecting.
NOTE: Maximum current of the load or the solar panel should not exceed 10A.
NOTE: Solar panel can not be connected in series. It will damage the controller.

The battery is charged by solar panel and the adapter at the same time

TCS3 Solar Charge Controller Wire Connection

Firstly connect the battery to the controller and then connect the solar panel to the “SOL” terminal of the controller. Connect the “BAT” terminal of Control Board of gate opener to the battery as wiring diagram above. The 2 wires of “LOAD” terminal of the controller are not used. Never short the two wires of the “LOAD” terminal. Don’t use the cord which is smaller than 0.75mm2 (18 AWG) when the length is longer than 22.5m (75’). The 2mm2 (14 AWG) or 3.3 mm2 (12 AWG) is strongly recommended for 30m (100’) or 45m (150’) extension distance. Please note the polarity of all the appliances while connecting.
NOTE: Maximum current of the load or the solar panel should not exceed 10A.
NOTE: Solar panel can not be connected in series. It will damage the controller.

Indicators

TCS3 Solar Charge Controller Indicators

LED1 is ON when the battery is not full-charged and it is OFF when the battery is full-charged. LED2 is ON when the battery is over-discharged and it is OFF when the battery could power the gate opener normally.

TOPENS Website
www.topens.com
Any question, please do not hesitate to contact us: E-mail:support@topens.com
Kindly include your Product Model, Purchasing Date & Site, Order #, and your contact information. All your concerns will be replied within 24 hours.
Tel: +1 (888) 750 9899 (Toll Free USA & Canada)

TOPEN-Logo.png

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals