OXIDICE DLV28-10 Series Ozone Generator Instruction Manual
Service Timeline
Inspect and clean at these service intervals
Monthly | Inspect and clean fan filter as required |
---|---|
y 1-6 Months | Clean diffuser as required |
1-3 Years (9,000 Hours) | Replace ozone cell and power supply Replace ozone |
outlet fitting Replace ozone check valve Replace delivery hose
Part Number| Description
---|---
AC30| Compressor
CCA1774ASA| Control Board
DIF33| Diffuser
FAN8| Fan
FAN15| Filter
MCD350SA| Ozone Cell
CKV55| Ozone Check Valve
FTP708| Ozone Outlet Fitting
DLV28-10| Delivery Hose (10’)
Internal Components
Identify User Serviceable Components
External Controls and Components
Identify Mounting Hardware and Controls
Fan Filter Service
Be gentle while removing filter guard
Remove the filter:
- Power down the Oxidice
- Gently hook and pry off the fan cover
- Separate the fan guard and the fan filter
Do not pull from center of fan guard. This may result in damage to the fan guard
Fan Filter Service
Rinse, dry, and reuse
Cleaning the fan filter :
- Gently rinse the filter under warm water
- Gently rinse the plastic fan guard
- Let both dry completely before reinstalling
Replace the fan filter:
- Place filter over fan housing
- Attach filter guard. Ensure that it snaps into place.
- Initiate operation of Oxidice
Don’t stretch or agitate the filter too much. This could result in tears in
the filter and premature replacement.
Filter Part ID : FAN15
Cleaning the Diffuser and Tubing
Soak, rinse, and reinstall
Part ID: DIF33
- Remove the diffuser from the water reservoir.
- Soak the diffuser for 30 mins in either:
- Vinegar
- Citric acid* or similar acid (20% solution, approximately one (1) tablespoon of powder per two (2) cups of water)
- Rinse with two (2) cups of tap water or until all of the acid has been washed off.
- Soak the diffuser in 200 ppm of chlorine bleach (approximately 1/2 tsp 6% bleach solution to two (2) cups of water) with liquid at ambient temperature for 30 minutes.
- Rinse with two (2) cups of tap water or until all bleach solution has been washed off.
- Wipe down outside of the delivery tube with the 200ppm bleach solution. Apply so that the tubing remains visibly wet for 20 seconds.
Ensure the stainless-steel diffuser is completely submerged in the acidic solution for the entire 30 minutes.
Replacing the Check Valve
Remove and replace at 9,000 hours
Replace the check valve:
- Power down the unit to stop ozone production
- Disconnect the check valve from tubing
- Determine the direction of flow on new check valve
Note: The flow direction should point toward the diffuser. If unsure of correct direction, blow through it gently.
- Reinstall new check valve inline
- Initiate operation of Oxidice
If bubbles do not appear after check valve replacement, confirm proper orientation of check valve.
Removing the Old Ozone Cell and Power Supply
Removing the Cover
Separate the cover from the chassis
- Power down the system
- Unplug from wall outlet
- Flip unit over, exposing the back side
- Using a Phillips head screwdriver, loosen the cover screw counter clockwise. Set screw aside.
- Slide chassis out horizontally from cover and set cover aside. It’s easiest to slide toward the power cord side.
NOTE: Don’t lose the cover screw! It’s small and will be needed later
Disconnect Ozone Power Supply Wires Disconnect the black and white wires from control board
- Using a small flat head screwdriver, loosen terminal connections counter clock-wise
- Disconnect the BLACK and WHITE wires as shown on the lef
NOTE : Do not pull the wires out until connectors have fully released the wire ends
Remove the Control Board
Unscrew and push aside circuit board
- Using a Phillips head screwdriver, remove each of the 4 screws securing the control board.
- Lift board away from bracket and push aside as shown.
NOTE: Be gentle with the circuit board. Do not scrape on bracket.
Release the Ozone Cell From Bracket
Remove screws counter-clockwise
- Using a small Phillips head screwdriver, remove the 2 screws securing the chamber to the bracket.
- Lift board away from bracket and push aside as shown.
NOTE: Be gentle with the circuit board. Do not scrape on bracket.
Disconnect Ozone Cell Tubing
Release reaction chamber from bracket
- Gently disconnect the tubing from the compressor as shown.
- Perform the same step for the other end of the tubing at the ozone outlet fitting.
NOTE: Do not cut tubing to remove tubing. This tubing can be reused.
Remove the Control Board Mounting Bracket
Release reaction chamber from bracket
- Using a Phillips head screwdriver, remove each of the 3 screws securing the control board bracket.
- Separate bracket from the chassis standoffs and set aside. This will reveal the ozone power supply underneath.
Be careful not to scratch the orange tape on bracket. This insulating tape prevents the ozone cell from shorting.
NOTE: Be careful not to scratch the orange tape on bracket!
Release Ozone Power Supply from Chassis
Remove screws counter-clockwise
- Using a 1/4˝ nut driver, loosen each of the 2 nuts securing the ozone power supply to the chassis
- Separate power supply from the chassis and discard power supply and ozone cell.
NOTE : Don’t lose these Keps nuts. You will reuse them later.
Installing the New Ozone Cell and Power Supply
Reposition Wire on Ozone Cell
Move the Blue wire before installation of new chamber
- Using a Phillips screwdriver, remove the screw securing the BLUE wire onto the ozone cell.
- Reposition the BLUE wire to the opposite corner on the ozone cell as shown.
NOTE : Moving the Blue wire will make installation much easiert
Reinstallation Continued
Reverse steps
Once the blue wire has been repositioned, reverse steps 1 through 7 to
complete reinstallation of the new power supply and ozone cell.
Tips for reinstallation:
- Make sure the RED high voltage wire from the ozone cell is not resting or touching the any items that could conduct electricity. This includes the chassis, brackets, tubing, etc…
- Ensure that ALL orange insulating tape has not been scraped, worn away, or damaged before reinstallation.
- IF your power supply arrives with the insulating tape missing, carefully remove the orange tape from your previous ballast and place onto the new ballast as shown.
- The insulating tape should protect these components from shorting.
- Ensure all electrical items (wires, power supply , ozone cell, etc…) are secured before testing and closing unit
Replacing the Ozone Outlet Fitting
Replace ozone outlet fitting at 9,000 hours of use
- Using a pair of needle nosed pliers, gently remove the nut from the ozone outlet fitting installed on the chassis
- Install the new fitting in the direction as shown
- Tighten the nut until snug
Be careful to not over tighten the nut. This may result in cracking the nut.
NOTE: Don’t over tighten! This can result in cracking the nut.
Replacing the Ozone Outlet Fitting
Replace ozone outlet fitting at 9,000 hours of use
- Using a pair of needle nosed pliers, gently remove the nut from the ozone outlet fitting installed on the chassis
- Install the new fitting in the direction as shown
- Tighten the nut until snug
Be careful to not over tighten the nut. This may result in cracking the nut.
NOTE : Don’t over tighten! This can result in cracking the nut.
Resetting the Service Run Time Indicator
After Servicing, Reset the Service Run Time Indicator
The RED service light will need to be reset by the user after performing service.
How to reset the Service Run Time Indicator:
While the unit is powered and the RED service light is illuminated, press and
hold the mode selection
button for 10 seconds. The service light should no longer be illuminated,
resuming normal operation.