KARCHER IVC 60-24-2 Ap Industrial Vacuum Cleaner Instructions

June 4, 2024
Karcher

KARCHER IVC 60-24-2 Ap Industrial Vacuum Cleaner

KARCHER IVC 60-24-2 Ap Industrial Vacuum Cleaner-PRO

Environmental protection

  • The packaging material can be recycled. Please do not throw the packaging material into household waste; please send it for recycling.
  • Old appliances contain valuable materials that can be recycled; these should be sent for recycling. Batteries, oil, and similar substances must not enter the environment. Please dispose of your old appliances using appropriate collection systems.

Notes about the ingredients (REACH)
You will find current information about the ingredients at: www.kaercher.com/REACH

Danger or hazard levels

  • DANGER
    Pointer to immediate danger, which leads to severe injuries or death.

  • WARNING
    Pointer to a possibly dangerous situation, which can lead to severe injuries or death.

  • CAUTION
    Pointer to a possibly dangerous situation, which can lead to minor injuries.

  • ATTENTION
    Pointer to a possibly dangerous situation, which can lead to property damage

Proper use

WARNING
The appliance is not suitable for vacuuming dust which endangers health.

  • The machine is meant for dry and wet cleaning of floors and walls.
  • This appliance is suited for commercial and industrial use, e.g. in storage and assembly areas and on production machines.
  • The appliance is not approved for crane loading.

Device elements

KARCHER IVC 60-24-2 Ap Industrial Vacuum Cleaner-1

  1. Power cord
  2. Nameplate
  3. Filter dedusting
  4. Flat fold filter
  5. Suction head
  6. Handle of the suction head
  7. Right unlocking of the placement mechanics
  8. Intermediate ring
  9. Steering roller of the dirt container
  10. Stopper
  11. Dirt receptacle
  12. Left unlocking of the placement mechanics
  13. Wheel
  14. Suction headlock
  15. locking door of the suction nozzle
  16. Steering roller of the chassis with the parking brake
  17. Floor nozzle holder
  18. Chassis
  19. Drain pan
  20. Handle of the dirt container
  21. Suction support
  22. Holder for the suction pipe
  23. Rotating knob
  24. Filter cover
  25. Button for filter shake-off system
  26. Cable clamp
  27. Push handle

Startup

  • Bring the appliance to a working position – secure it, if required, with parking brakes.
  • Insert the suction hose (not included) into the suction hose connection.
  • Check the fill level in the dirt container prior to starting work and empty the container if necessary.
  • Ensure that the dirt container has been inserted properly.
  • Attach the desired accessories (not included).

Operation

CAUTION
The flat pleated filter must always be in place while vacuuming.

Dirt receptacle
Note: The dirt container needs to be emptied if it is full until about 3 cm below the upper rim.

  • Check the fill level of the dirt container at regular intervals, as the appliance does not shut off automatically

Dry vacuum cleaning

CAUTION
Please note the following when switching from wet to dry vacuum cleaning: If you vacuum dry dust while the filter element is still wet the filter will become obstructed and may be damaged beyond repair.

  • Dry the wet filter properly before use or replace it with a dry one.
  • Change the filter, if required, according to instructions under the section “Maintenance and Care”.

Wet vacuum cleaning

Caution: Constantly monitor the fill level in the dirt receptacle when vacuuming high volumes of liquid, as the receptacle can be filled within a matter of seconds and could overflow.
CAUTION
Please observe the local provisions regarding wastewater treatment.

  • If wet dirt is vacuumed with the crevice nozzle or if high volumes of liquid are sucked up from a container, it is recommended to deactivate the “Semiautomatic filter dedusting” function.
  • After the wet vacuuming: Clean the flat folded filter with the filter cleaning. Clean the flat-fold filter. Clean the container with a damp rag and dry it

Rotating knob

  • Appliance ON

  • Appliance OFF

Turning on the Appliance

  • Plug in the mains plug.
  • Switch on the appliance at the rotating knob.

Semi-automatic filter dedusting

Note: A filter dedusting every 5 to 10 minutes will increase the life of the flat folded filter.
Note: The semi-automatic filter dedusting function can only be switched on when the appliance is switched on. Illustration

  • Close the locking door of the suction nozzle.
  • Press the semi-automatic filter dedusting key five times. The flat folded filter is automatically cleaned through an air jet (pulsating sound).
  • Reopen the locking door of the suction nozzle

Turn off the appliance

  • Actuate the key for the semi-automatic filter dedusting 5 x with the locking door of the suction nozzle closed. Reopen the locking door.
  • Switch off the appliance at the rotating knob.
  • Pull out the mains plug.

After each operation

  • Lock parking brakes. Illustration
  • Pull the locks of the placement mechanics up.
  • Pull the push handle upward. The container is unlocked and lowered. IllustrationKARCHER IVC 60-24-2 Ap Industrial Vacuum Cleaner-4
  • Pull the container out by the handle.
  • Empty the container.
  • Reinsert the container and lock it with the push handle.

Storing the Appliance

  • Wrap the mains cord around the cable holder.
  • Wind the suction hose around the sliding bow.
  • Insert the floor nozzle and the suction pipe into their respective holder.
  • Place the appliance in a dry room and secure it from unauthorized use.

Transport

CAUTION
Risk of injury and damage! Observe the weight of the appliance when you transport it.

  • Release the park brakes and push the appliance by the push handle.
  • Grab the appliance by the chassis, not by the sliding bow to load it.
  • When transporting in vehicles, secure the appliance according to the guidelines from slipping and tipping over.

Storage

CAUTION
Risk of injury and damage! Note the weight of the appliance in case of storage. This appliance must only be stored in interior rooms.

Care and maintenance

DANGER
First pull out the plug from the mains before carrying out any tasks on the machine.

Exchanging the flat pleated filter

  • Open filter door.
  • Replace the flat pleated filter.
  • Close the filter door, it must lock into place

Troubleshooting

DANGER
First pull out the plug from the mains before carrying out any tasks on the machine.

Suction turbine does not run

  • Check the receptacle and the fuse of the power supply.
  • Check the power cable and the power plug of the device.
  • Turn on the appliance.

Suction capacity decreases

  • Remove blockages in the suction nozzle, suction tube, suction hose, or flat pleated filter.
  • Check the suction head and the receptacle for proper seating.
  • Actuate the key for the semi-automatic filter dedusting 5 x with the appliance switched on and the locking door of the suction nozzle closed. Reopen the locking door.
  • Ensure the filter cover properly locks into place.
  • Replace the flat pleated filter.
  • Open the locking door of the suction nozzle

Dust comes out while vacuuming

  • Check for proper installation of the flat pleated filter.
  • Replace the flat pleated filter.

Semi-automatic filter dedusting does not work

  • Close the locking door of the suction nozzle.
  • Clean the suction nozzle if the locking door is blocked.
  • Inform Customer Service.

Warranty

The warranty terms published by the relevant sales company are applicable in each country. We will repair potential failures of your appliance within the warranty period free of charge, provided that such failure is caused by faulty material or defects in manufacturing. In the event of a warranty claim please contact your dealer or the nearest authorized Customer Service center. Please submit the proof of purchase.

Accessories and Spare Parts

Only use original accessories and spare parts, they ensure the safe and trouble-free operation of the device. For information about accessories and spare parts, please visit www.kaercher.com.

  • Accessories are not included in the delivery. The accessories for the device must be ordered separately, depending on the application.
  • The device’s correct function is only ensured when using suction hose nominal widths of DN40 and DN50.
  • You can procure the spare parts and the attachments from your dealer or your KÄRCHER branch office.

EU Declaration of Conformity

We hereby declare that the machine described below complies with the relevant basic safety and health requirements of the EU Directives, both in its basic design and construction as well as in the version put into circulation by us. This declaration shall cease to be valid if the machine is modified without our prior approval.

Product: Wet and dry vacuum cleaner
Type: 1.576-xxx

Relevant EU Directives

  • 2006/42/EC (+2009/127/EC)
  • 2011/65/EU
  • 2014/30/EU

Applied harmonized standards

  • EN 55014–1: 2017 + A11: 2020
  • EN 55014–2: 2015
  • EN 60335–1
  • EN 60335–2 –69
  • EN IEC 61000–3–2: 2019
  • EN 61000–3–3: 2013 + A1: 2019
  • EN 62233: 2008
  • EN IEC 63000: 2018

Kärcher Industrial Vacuuming GmbH
Robert-Bosch-Straße 4-8
73550 Waldstetten (Germany)
Phone: +49 7171 94888-0
Fax: +49 7171 94888-528
Waldstetten, 2020/10/01

Technical specifications

| IVC 60/24-2 Ap

*EU

*CH

| IVC 60/24-2 Ap

*GB

---|---|---
Mains voltage| V| 220-240| 110
Frequency| Hz| 1~ 50/60| 1~ 50/60
Max. performance| W| 2760| 2450
Rated power| W| 2400| 2150
Container capacity| l| 60| 60
Air volume (max.)| l/s| 2x 74| 2x 66
Negative pressure (max.)| kPa (mbar)| 25,4 (254)| 22,0 (220)
Type of protection| —| IP X4| IP X4
Protective class| —| I| I
Suction hose connection (C-DN/C-ID)| DN| 70| 70
Nominal width of suction hose| DN| 40/50| 40/50
Length x width x height| mm| 970 x 690 x 995| 970 x 690 x 995
Filter area| m2| 0,95| 0,95
Typical operating weight| kg| 60| 60
Max. ambient temperature| °C| +40| +40
Values determined to EN 60335-2-69
Sound pressure level LpA| dB(A)| 73| 73
Uncertainty KpA| dB(A)| 1| 1
Hand-arm vibration value| m/s2| <2,5| <2,5
Uncertainty K| m/s2| 0,2| 0,2
Power cord| H07RN-F 3×1,5 mm2|
Part no.:| Cable length
EU| 6.649-915.0| 10 m
CH| 6.650-168.0| 10 m
Power cord| H07RN-F 3×2,5 mm2
Part no.:| Cable length
GB| 6.650-169.0| 10 m

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals