ALT PL175 E Alerta Powerlifter User Manual
- June 4, 2024
- alerta
Table of Contents
Maxi 175 Electric Legspread
ALT PL175 E Alerta Powerlifter
User Manual
ALT-PL175-E Alerta Powerlifter
UK Version
Features, warranty & technical service
This product is intended by the manufacturer to be used on humans for the
purpose of lifting, lowering, and moving users. If the buyer or user allows
unauthorized personnel to operate the product or fails to observe the cleaning
and maintenance recommendations contained in this manual, all warranty rights,
and liability claims will be forfeited.
Our products have a 2-year warranty against ny manufacturing fault (12 months
in the case of batteries and electrical equipment).
Alerta Medical sells all its products through a network of distributors. In
the event of a problem, the end user should contact the DISTRIBUTOR from whom
they have purchased the product. Alerta Medical provides distributors with the
spare parts needed to undertake maintenance work on the products.
Alerta Medical operates a policy of continuous improvement of all its
products. Hence, device specifications may change without prior notice.
Safety precautions
Any person using or assembling these items must first read and understand the
assembly, operating, and cleaning instructions provided. Read all safety
information contained in this manual (highlighted with the symbol ) carefully.
Failure to follow these instructions may result in damage to property and/or
personal injury.
2.1 Recommendations
Familiarise yourself with the safety controls and devices before operating the
hoist. Use a sling that is CE marked and check that its size and other
characteristics are appropriate to the patient. Do not use a sling that is
frayed or worn, and always follow the instructions provided with it.
Check that the combined weight of the patient and the sling does not exceed
the maximum working load displayed on the hoist. Preferably, the patient
should be as close to the floor as possible prior to transferring him or her.
A loaded hoist should always be used on flat, smooth surfaces that are free of
obstacles. If moving a patient along a sloping surface, the gradient must not
be greater than 5° and it is recommended to use the assistance of a helper.
Never leave a hoist loaded with a patient on a sloping surface. Transfer the
patient with the hoist legs in a parallel position at a maximum speed of 3
km/h (0.8 m/s). Keep the hoist away from water, humidity, splashes, and
corrosive atmospheres (indoor swimming pools, the sea, etc.). Do not use the
electric hoist in the shower or recharge the battery in the bathroom.
Do not force the safety controls and devices. Do not push the mast, the boom
or the patient to move the hoist.
2.2 Braking and moving
**While the hoist is stationary, the brakes should always be on, except
when lifting or lowering a patient. If the wheels are free to rotate during
these operations, the hoist will find the center of gravity of the hoist
patient unit. On the other hand, if the wheels are locked, the patient will be
dragged to the center of gravity of the hoist patient unit, which will result
in discomfort.
2.3 Before moving a patient
**Consider individual hazards, including:
- Risk of crushing/squeezing.
- Potential falls.
- Disturbed patients.
- Patients with learning difficulties.
- Small children and pregnant women.
- Persons without the mental capacity to recognize unsafe behavior.
- Unauthorized persons.
Anybody who is authorized to use the hoist must be able to do so in a safe and
controlled way.
**Due to the continuous, smooth lifting action of the moving parts, there
is a risk of entrapment. When operating these parts, the user and/or the carer
must make sure that there are no body parts in the areas where they may become
trapped.
2.4 Identifying risk patients**
The following recommendations are aimed at care personnel to help reduce the
specific risks that may affect certain patients. These hazards are listed in a
number of reports drawn up by national government agencies with
recommendations to reduce them.
It is recommended to establish a patient admission procedure that enables
identifying risk profiles and applying measures suited to the health condition
and behavior of such patients. Risk profiles include:
- Elderly and/or disabled patients.
- Patients with dementia, mental illness, hydrocephaly or disorientation.
- Agitated and/or aggressive patients. The measures tested and approved include establishing a protocol with the following points:
- When and for what purpose the hoist may be used, as well as the type of sling, immobilization equipment, and any other specific measures.
- When and for what purpose the patient should be immobilized or the use of other means to reduce the risk of falls is required (e.g. laying foam on the floor).
- If special means are used to immobilize a patient, closely follow the instructions and advice provided by the manufacturer.
- How a patient should be monitored or immobilized, including during intervals.
2.5 Electrical safety precautions
All the hoist’s electrical connections must comply with the International
Electrotechnical Commission (IEC) standards. The power supply should be
equipped with an earth leakage circuit breaker with a maximum operating
current of 30 mA, as prescribed by standard IEC 364-5-53.
This product complies with the standards EN 60601-1 and EN 60601-1-2 on
electrical apparatus and the electromagnetic interference of medical devices.
Therefore, it does not interfere or does not interfere when combined with
other medical devices that also comply with electromagnetic standards.
Some apparatus, particularly older devices, that do not comply with
electromagnetic compatibility standards may, however, causer be affected by
interference when used with this hoist. If using such apparatus, you must make
sure that any potential malfunction will not harm the patient or any other
person.
****Before moving the hoist, make sure the power supply cable is unplugged
from the mains. Any work on electrical parts may only be undertaken by
authorized, qualified personnel.
Assembly
**No tools are necessary to assemble the hoist, although some parts are
considerably heavy. It is therefore advisable to use the assistance of a
helper when handling such parts. Pay attention to avoid being knocked or
trapped.
3.1. Components (see page 07)
Carefully remove the packaging and place the wo pre-assembled structures
supplied in a clear area. (Picture 1)
BASE STRUCTURE**
-
Mast base
-
Cover protection motors opening legs
-
Rear wheels (with brakes)
-
Legs
-
Front wheels (without brake)
MAST-BOOM STRUCTURE -
Mast
-
Arm
-
Handle
-
Two-hook spreader bar
-
Hooks for a 4-point harness
-
Electric actuator
-
Battery charging base (control box)
-
Removable battery
-
Manual control knob
-
Handle (initially placed in the frame)
-
Mast bracket (actuator lower support)
-
Boom bracket (actuator top support)
Model Alerta Powerlifter
3.2 Joining the pre-assembled structures
Carefully remove the packaging.
Place the base structure on the floor with the brakes on the rear wheels (3).
Remove the locking knob (15)(B), DON’T REMOVE THE GREY PLASTIC PIECES OF THE
MAST BASE, and insert the mast-boom structure in the mast base (1). Align the
holes in the mast (6) and base and put the locking knob (15)(B) back in place,
making sure it is tight and secure.
Check with the buttons (H) that the legs open and close normally and that the
wheels rotate correctly. Check that the spreader bar rotates and swings freely
and is firmly stened to the arm.
4. Operating Instructions (see images on page 08)
4.1 Spreading and narrowing the legs
To open/close the legs you have to use the lower buttons of the control box or
the control (H), which activate the motors (Q). These two motors work
simultaneously using a Y-type cable(P). To transfer patients and/or pass
between doors or through narrow corridors it is recommended that the legs are
closed.
4.2 Lifting and lowering
Use the top buttons (G) on the box or control for lifting or lowering the
hoist arm. During the descent or hoisting of the patient, it is recommended
that the wheels are not braked. In this way, the patient-hoist assembly will
look for the center of gravity avoiding discomfort to the patient.
When the arm reaches its lower or upper limit it stops automatically.
It is advisable to avoid repeatedly pressing the buttons (G-H), since the
successive start-ups of the motor consume more battery, reducing its useful
life.
The computer goes into standby mode if no button is pressed. To reactivate it,
press any button.
4.3 Emergency stop and safety lowering
The electrical equipment has a red emergency stop button (F). With the button
released the battery is ready to work. With the button pressed the battery
does not act. To release, the button must be rotated clockwise and released.
In case of battery failure, the actuator has a manual emergency descent
system. To do this, the red wheel (E) of the actuator must be pressed down,
while turning clockwise to slowly descend the patient.
4.4 Recharging the battery
During hoisting or descent, the load state pilots (I) of both the load base
and the command are illuminated. Two green pilots indicate capacity between
66-100%, 1 green pilot indicates capacity between 33-66% and 1 orange pilot
indicates capacity less than 33%).
The system emits an acoustic warning when the battery is about to run out,
allowing several complete cycles to be performed. If you only have a removable
battery and a charging base you must bring the hoist to a power outlet and
connect the cable to the charging base (N) and then connect to the network
(220V-240V).
**While the battery is being recharged the hoist motor is not working, the
emergency stop should not be pressed and the pilot (I) of the control box and
the control light up. The stripes of the battery flash. When it is fully
charged the 3 rays will remain fixed and then turn off.
Do not disconnect the charger plug by pulling the cable as it could be
damaged.
If you use the hoist daily it is recommended to recharge the battery at night.
The charger does not allow the battery to be overloaded. If you are not going
to use the hoist for a long time it is advisable to recharge the battery at
least every three months so that it is in its optimal state of use.
If you have an additional charging base (on request) you can recharge the
battery by removing it from the charging base installed on the hoist and
placing it in an additional charging base (O) installed next to a power
outlet.
4.5 Changing the battery
To remove the battery, hold it by the top handle (J) and release the metal
guide from the control box holder. To place it back in the charging dock, rest
the battery in the charging dock and insert the guide again until you hear a
“click”.
4.6 Overload
The control box stops working if the actuator is overloaded (due to excess
load or excess continuous operating time). It will work again after a few
minutes when the overload has been removed. Duty cycle approx.: 2 minutes in
continuous use and 18 minutes in rest.
4.6 Improper use**
Improper use of this hoist may cause injury to users and/or deteriorate
equipment, in addition to invalidating the product warranty. Examples:
- Use by a person who has not read this manual or who has not been trained by an authorized team member.
- Use of the hoist, functions, accessories, or movement of the hoist by persons not qualified to use it safely.
- Use of electrical functions by several people at the same time.
- Use of the hoist with a load higher than that identified on the hoist.
- Irregular connection to the mains when charging the battery.
- The connection of devices to the hoist is not authorized by the manufacturer.
- Displacement of the hoist by pulling the power cable.
- Wash with too much water, with jet pressure, or in a washing tunnel.
- Use outside or to transport a patient in a vehicle.
- Displacement on unconditioned soft ground.
- Displacement with the patient in terrain with an inclination greater than 5°.
- Extreme use of the motor without respecting the maximum load indicated on its label.
- Use of accessories or equipment other than those recommended by the manufacturer.
- Any other use of the hoist is not in accordance with the intended purposes.
- Not respecting the work cycle of the equipment: 2 minutes in continuous use and 18 minutes in rest.
Maintenance
5.1 Safety rules for cleaning and disinfecting
****The hoist has been designed for easy cleaning and optimal disinfection.
Failure to observe any of the following recommendations may result in damage
jeopardizing the proper operation of the hoist and the warranty of the
material.
- Make sure the hoist is immobilized and disconnected from the electricity mains.
- Press the red stop button to shut off the electrical functions.
- Never clean the hoist with copious water, with a high-pressure jet, or in a wash tunnel.
- Do not use water at a temperature above 60°C.
- Avoid any excess water on the connector sockets.
- Dry the hoist thoroughly before using it again.
5.2 Recommended products and materials for cleaning and disinfecting
- Clean cloths, disposable or recyclable. Cleaning gloves.
- A diluted solution of detergent or disinfectant, or a spray on disinfectant.
5.3 Recommended method for cleaning and disinfecting
- Use a cloth to clean from top to bottom and from the cleaner to the dirtier parts
- Dampen the cloth as often as necessary and wring out excess water.
- Allow the product to dry for the period of time recommended by the manufacturer to ensure maximum efficiency.
- If necessary, rinse following the instructions provided by the disinfectant supplier.
- Change the cloth when cleaning from the less dirty to the medium dirty or very dirty parts.
- Change the cloth to start Cleaning another hoist.
- Dry the hoist after cleaning.
5.4 Safety rules for maintenance
Before performing any maintenance or repair operation:
- Make sure the hoist is immobilized (if no movement is envisaged) and disconnected from the electricity mains.
- Press the red stop button to shut off the electrical functions.
- Do not under any circumstances open or puncture an electric motor.
5.5 Preventative maintenance
It is advisable to carry out a yearly maintenance check of the hoist and its
accessories to ensure they are kept in Good working order. Special attention
should be paid to the following aspects:
- Operating controls and mechanisms.
- The hinges are where the hoist and accessories move.
- The condition of the electric cables and the water tightness of the electrical devices.
- The condition of the sling (wear and fraying, tears, distortion, etc.).
It is recommended to grease the hoist’s hinges regularly.
Adapt the frequency and intervals of maintenance checks to the condition of
the hoist, the specific circumstances of its use and in line with local laws.
5.6 List of spare parts
Replacements for the electrical Equipment (including the battery) and parts
are available on request.
5.7 Transport and storage
All necessary precautions must be taken to ensure the safe transport of the
hoist and its accessories, avoiding knocks and dust. During transport, the
hoist must be in a low position, with its functions disconnected and the
brakes on the wheels on. Additionally, it must be secured with straps and
protected against water and humidity (75%), at a
temperature between -20°C and +50°C.
5.8 Troubleshooting
PROBLEM | CAUSE | REMEDY |
---|---|---|
The actuator is not working | The red emergency stop is activated | Turn the red |
button clockwise to deactivate
---|---|---
The battery is connected to the electricity mains for recharging| Unplug the
black power supply cable from the mains
The battery is low| Recharge the battery
The battery is not properly connected| Remove the battery and put it back in
place
The hand control or actuator cables are not properly connected| Insert the
cables correctly to the bottom
Hand control and/or actuator failure| Replace the hand control and/or the
actuator
The battery will not charge| Mains failure| Check mains supply
Malfunctioning battery and/or charging base| Replace the battery and/or the
charging base
The actuator stops| Hoist overloaded| Reduce the load and wait a few minutes
The battery is low| Recharge the battery
Noisy hinges| Lubrication is required| Apply lubricant to the hinges
The patient cannot be lowered| Actuator and/or hand control failure while the
boom was raised| Lower slowly the patient turning the collar on the actuator
(see 4.3. above)
The mast has too much clearance with the mast base| The grey plastic pieces of
the mast base are been removed| Put the grey plastic pieces on the mast base
again
The wheels do not rotate or brake properly| Dirt| Clean the wheels
Technical specifications
Powerlifter Maxi 175 Electric Legspread
Approx. size (cm) | A | B | C | D | E | F | G | H | I | J | K | L |
---|---|---|---|---|---|---|---|---|---|---|---|---|
64 | 100 | 116 | 55.5 | 63 | 52 | 34 | 94 | 24 | 70 | 75° | 63 | |
M | N | P | 0 | R | S | T | U | V | W | X | Y | |
11,5 | 6.5 | 186 | 133 | 128 | 45 | 157.5 | 132 | 140 | 120 | 140 | 0100 |
Notes …………………………………
EU 2017/745
EC REP Lifesciences Europe Ltd
The Black Church
St. Mary’s Place
Dublin 7
D07 P4AX
Ireland
eurep@cslifesciences.com
Making cutting-edge
medical equipment
affordable
Head Office
Alerta Medical
4 Symington Place
Riverside Business Park
Irvine
KA11 5DE
United Kingdom
www.alertamedical.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>