DS-A23 Bodylance Instruction Manual

June 15, 2024
Bodylance

BodyCup Pro
ISTRUCTION MANUAL

BODYCUP PRO SMART CUPPING THERAPY INTRODUCTION
The ancient healing method of cupping has continuously shown powerful benefits in improving cellular immunity, alleviating pain from knots, and dramatically improving blood flow while reducing cellulite. Combining this technique with modern therapy modules such as dynamic suctioning, red light therapy, therapeutic heating, and vibrational massaging, we have designed one of the most powerful all-in-one therapy for convenient at-home use.

DEVICE SPECIFICATIONS

Device BodyCup Pro
Model DS-A23
Device size 90mm90mm78mm
Charging voltage 5V 2A
Suction strength 60~0kPa
Rated power 5W
Executive standard GB4706.1-2005 GB706.10-2008

DS-A23 Bodylance - Overview

OPERATING GUIDELINES

Preparation Before Use

  1. It is recommended to clean and moisturize the skin before using the BodyCup Pro. You can apply essential oils or any moisturizer on targeted areas.
  2. Carefully remove and disinfect the transparent cup/tube by rotating it counter-clockwise, then dry it before and after each use.
  3. Tighten and install the transparent tube.

Power Button

  1. Press and hold for 1 second to turn on your BodyCup Pro. The LCD screen on the control panel will display the 20 minutes countdown, and the temperature indicator will light up. Each device is equipped with a run time of 20 minutes timing and automatically shuts down after 20 minutes.
    NOTE: it is important to only start with a few minutes as a beginner to test skin sensitivity.

  2. To shut your BodyCup Pro down, press and hold the Power Button. The LCD screen and red light will shut off, indicating that the device is now off.
    NOTE: Please be sure to press the Suction Release button prior to shutting off the BodyCup Pro to depressurize the skin for ease the removal.

  3. While your device is on, short press the Power Button to change between the two therapy modes:
    • Mode 1 (Deep Negative Pressure Mode): BodyCup Pro focuses on suction, deepening its negative pressure to maximize blood flow and consequently stimulate the muscle for repair.
    • Mode 2 (Dynamic “Breathing” Mode): the device dynamically alters between negative pressure and release, quickly switching between suctioning and “breathing” aiming to relax the skin with a gentle and revitalizing massage.
    NOTE: Upon start up, the default mode is set to Mode 1 (Deep Negative Pressure Mode) while the pressure intensity and temperature levels are set to level 1.

Suction/Pressure Intensity Button

  1. Upon powering on BodyCup Pro, suction intensity will be on level 1 by default.
  2. To switch between the 12 levels of intensity simply press the Suction Intensity Button to increase by 1 level. Each press will reveal the current intensity level on the LCD screen for a short while before switching back to displaying the countdown timer.
  3. Once you reach level 12, the next press will revert the intensity back to level 1.
    NOTE: For beginners, it is strongly recommended to start with level 1 intensity for just a few minutes as your skin needs to adapt to cupping therapy. It is also advised to pay close attention during your first few sessions to avoid overworking the skin as you determine your sensitivity/tolerance. More advanced users may go up to higher levels for a maximum of 20 minutes on each targeted area, every other day.

Temperature control button

  1. Level 2 temperature & Red Light Therapy is activated by default. The temperature has 12 levels of heat. Each press will reveal the current temperature level on the LCD screen for a short while before switching back to displaying the countdown timer.
  2. Upon reaching level 12, the next press will bring the temperature to 0 (effectively shutting off any heat and red light therapy).
  3. When the temperature level reaches level 9, the temperature indicator on the screen will start flashing between various colors, indicating that you are reaching high levels of heat. Increasing beyond level 9 heat will speed up the flashing lights.

Pressure Relief/Pause Button
During cupping, fi you want to immediately shut-off the suction feature to remove the device easily, briefly press this key to release all pressure and enter the standby state.
NOTE: When using BodyCup Pro with essential oils, please be sure to keep the oil on the skin. After the skin surface evenly coated so BodyCup Pro can apply pressure properly and function. BodyCup Pro si designed with a filter that can filter out most unwanted particles during use to avoid any contamination into the electrical components from the pressure vents. Please carefully clean your BodyCup Pro after use and frequently replace and/or clean the filter to ensure reliability.

Cotton filter

BodyCup Pro is designed with a circular cotton filter to catch unwanted particles during use, effectively blocking debris from reaching into the electrical components through the vents. Please carefully clean your BodyCup Pro after use and replace or clean your filter after each week of use to maximize reliability.

SAFETY PRECAUTIONS

Please read and understand this section to prevent personal injury that may be caused by incorrect operation.
Do not use the following medical electronic equipment at the same time as it may cause errors or damage to medical instruments, which can be life threatening.

  1. Implantable medical electronic devices such as a cardiac pacemaker.
  2. Life-sustaining medical electronic devices such as artificial hearts and lungs.
  3. Electrocardiographs and other medical electronic instruments.
  4. Patients with other medical implants.
  5. Keep out of reach from children.

Bruising and Blisters

  • Bruising after BodyCup Pro is normal and a good sign that your therapy is effective and it’s bringing toxins up to the skin, however, it is possible that BodyCup Pro, or any kind of cupping therapy, may form blisters on the skin.
  • Although it is rare, blisters form due to overuse as a beginner (high intensity/prolonged session), negligence to disinfect the skin or BodyCup Pro prior to use, or simply because your skin type is sensitive to cupping therapy and/or heat.
  • This is why we strongly advise beginners to start off very slowly at low intensity levels, using BodyCup Pro for just a couple minutes per muscle group to get a good feel for how their skin reacts.
  • Again, blisters are extremely rare but a possibility due to the nature of cupping therapy, please pay close attention to each session and stop using BodyCup Pro immediately if you feel strong discomfort br blisters forming.

Please do not use the device under the following circumstances to avoid accidents or discomfort:

  1. Patients who are pregnant, menstruating, with a damaged epidermis, varicose veins, and taking drugs.
  2. Patients with infectious diseases, skin sensitivities, and post-operative patients, patients with high fever or critical illness are also prohibited.
  3. Patients with malignant tumor or local damage and ulceration, traumatic fracture, acute suppurative inflammation, skin patients with loss of elasticity.
  4. Patients with abnormal heart, brain nerve, and blood pressure.
  5. Severe neuroticism, convulsion, spasm, and manic anxiety.
  6. Diseases prone to bleeding such as thrombocytopenia, leukemia, hemophilia, henoch Schonlein purpura, and other diseases associated with bleeding.
  7. Near the heart, facial features, private parts, or large blood vessels on the body surface.
  8. Patients with skin perception disorder or abnormal skin.
  9. The patient who is being treated by a doctor or feels physically abnormal.
  10. Excessive fatigue, drunkenness, and staying up too late (2 hours before and after meals are also prohibited).
  11.  Patients whose skin is allergic to metal and red light.
  12. The device has a heating surface. Hence, the device is not for children who are unable to express their wishes freely or people who are unable to self-manage the device.

Please be advised, our company and associated companies are not liable for any injury caused by the use or misuse of this device. It is always recommended to consult with your physician before using or applying our device or any therapy device onto your body. Your health and satisfaction are our top priority.
Please read and understand this section to prevent personal injury caused by the wrongful operation:

  1. Please use BodyCup Pro correctly, in accordance with the operating instructions.
  2. When using BodyCup Pro, the transparent tube should be securely attached to the skin and evenly applied while avoiding contact with wounds and scars.
  3. The transparent tube may cause low-temperature scald or skin strain when used for a long time on sensitive skin, though this is rare. Regardless, please pay attention during use to avoid this.
  4. If you feel unwell when using BodyCup Pro please stop immediately and consult with you physician.
  5. Sharing the BodyCup Pro with another person.
  6. Do not use a notched or damaged transparent tube.
  7. After using this device, redness or ecchymosis may occur, which is a normal reaction to effective cupping therapy and usually subsides within 3-5 days (according to the individual’s skin type).
  8. Wear your bruises proudly!
  9. When BodyCup Pro functions for a long time over a single session, there will be heating on the surface which is normal, just be mindful of your skin’s sensitivity.
  10. In case of any abnormality during use, remove it immediately.
  11. Do not use the device while driving.
  12. Do not plug and unplug the USB charging cable with wet hands to prevent electric shock or accidents.
  13. This device contains a lithium battery; please do not disassemble, change, immerse it in water, or throw it into the fire to prevent damage and the device exploding/popping.

After use, the blood vessels on the targeted skin will dilate. You should rest for 45 minutes before bathing.

CLEANING AND MAINTENANCE

Please observe the cleaning and maintenance methods provided below to prolong the service life of BodyCup Pro:

  1. Wipe the tube with a dry non-woven cloth. Do not use acid-base detergent, alcohol, diluent, or gasoline. Clean with a solvent such as a nail remover.
  2. Turn off the power supply after each use and clean it with a damp towel.
  3. Store this device in a safe dry place.
  4. Do not leave BodyCup Pro idle with water residue.
  5. Do not use a hard brush to wipe.
  6. Do not use water and other liquids directly on the the device for cleaning.
  7. When the device is idle for a long time, please charge the device frequently to ensure its normal operation.

Please do not store in the following areas or under the following conditions:

  • Places vulnerable to vibration and impact.
  • Places with direct sunlight.
  • Hot and humid places.
  • Places with water.
  • Places with strong electromagnetic fields.
  • Near fireworks.
  • Places easily accessible to children.
  • Hot locations.

AULT ANALYSIS AND TROUBLESHOOTING

Faulty phenomenon Fault judgement and solutions
Unable to power on 1. Press and hold the power button for more than 1.5

seconds.
2. Please charge BodyCup Pro for a few hours and try again.
Unable to charge| 1. Replace the adapter with a row socket & try again.
2. Pull out the charging head and plug it in again & confirm that it is inserted in the right place
3. Please check the charging head and the charging port for the possible presence of dirty. If yes, kindly clean up.
4. Replace the adapter or charging cable.
Weak suction| 1. Remove the tube and re-tighten it for installation.
2. Check the air inlet and exhaust holes for possible blockage.
3. Check if the filter cotton needs to be replaced.
Weak temperature| 1. Check if the temperature function is turned on and the temperature prompt light is on.
2. As a result of ambient temperature, kindly increase the temperature gear.
3. The battery is low, please charge it

If the problem persists after the above fault analyst and troubleshooting, do not disassemble the device instead please get in touch with our team at management@bodylance.co.uk!

FINAL REMINDER

  1. When using the BodyCup Pro for the first time, pay attention to the step-by-step adjustment to find a suitable mode and intensity.
  2. If the pressure is too high during the deep negative pressure mode, please press the pressure relief/pause button to relieve pressure to avoid skin discomfort.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals