  • Model: XP13000X
  • Manufacturer: Duromax
  • Address: 5800 Ontario Mills Pkwy Ontario, CA 91764 USA
  • Website: www.duromaxpower.com
  • Customer Care Team: Toll Free 8-5 pm PST Mon-Fri, 844-DUROMAX

Introduction

The XP13000X is a generator designed for providing backup power in various situations. This user manual contains important information on the operation and maintenance of the generator.

General Safety Procedures

Before operating the generator, it is important to follow these safety procedures:

  • Read and understand the entire user manual before using the generator.
  • Ensure the generator is placed on a stable and level surface.
  • Keep flammable materials away from the generator.
  • Do not operate the generator in enclosed or poorly ventilated areas.
  • Always turn off the generator and disconnect any loads before refueling.
  • Do not touch hot surfaces of the generator.
  • Keep children and pets away from the generator.

Carbon Monoxide Safety

Carbon monoxide (CO) is a colorless and odorless gas that can be produced by the generator. To prevent carbon monoxide poisoning, follow these guidelines:

  • Never use the generator indoors or in enclosed spaces.
  • Place the generator at least 20 feet away from any building or structure.
  • Install carbon monoxide detectors in your home or building.
  • Do not sleep near the generator or leave it running overnight.

Unit and Purchase Information

This section provides information about the generator unit and purchase details. Refer to the user manual for specific information.

Generator Components

The generator is composed of various components. Familiarize yourself with these components before operating the generator.

Package Contents

Check the package contents to ensure you have received all the necessary items for the generator setup.

Generator Setup

To set up the generator, follow these steps:

Remove Shipping Braces

Remove any shipping braces or packaging materials from the generator.

Wheel Kit Installation

Install the wheel kit according to the instructions provided in the user manual.

Connect the Battery

Connect the battery to the generator following the specified instructions.

Adding Oil

Add the recommended type and amount of oil to the generator. Refer to the user manual for specific instructions.

Adding Gasoline

Add gasoline to the generator’s fuel tank. Follow the guidelines provided in the user manual for proper fueling procedures.

Grounding the Generator

Ensure proper grounding of the generator to prevent electrical hazards. Refer to the user manual for detailed grounding instructions.

High Altitude Operation

If operating the generator at high altitudes, follow the instructions provided in the user manual for proper adjustment.

Starting the Generator

Before starting the generator, perform the following checks:

Checking the Oil

Check the oil level and ensure it is within the recommended range. Add or replace oil if necessary.

Check the Gas Level

Verify that the generator has an adequate supply of gasoline.

Starting the Generator

Follow the specified starting procedure in the user manual to start the generator.

Starting the Generator Using Recoil Start

If equipped with a recoil start, follow the instructions provided in the user manual for starting the generator using this method.

Using the Generator

Once the generator is running, you can utilize its capabilities for various purposes.

AC Usage

Connect your electrical devices to the generator’s AC outlets to power them.

Connecting the Generator to a Home

If you want to connect the generator to your home’s electrical system, refer to the user manual for detailed instructions and safety precautions.

Connecting a Load to the Generator

To power specific loads or appliances, connect them directly to the generator using appropriate cables or connectors.

Choosing the Right Power Cord

Select a power cord suitable for your intended usage and ensure it is compatible with the generator’s output. Refer to the user manual for guidance.

Using the Digital Multimeter

The generator may come with a digital multimeter for monitoring voltage and other electrical parameters. Refer to the user manual for instructions on using the multimeter.

FAQs

Q: Can I use the generator indoors?

A: No, the generator should never be used indoors or in enclosed spaces due to the risk of carbon monoxide poisoning.

Q: How far should the generator be placed from buildings?

A: The generator should be placed at least 20 feet away from any building or structure to prevent carbon monoxide buildup.

Q: Can I leave the generator running overnight?

A: No, it is not recommended to leave the generator running overnight. Always turn it off when not in use.

Q: What type of oil should I use for the generator?

A: Refer to the user manual for the recommended oil type and specifications for your specific generator model.

Q: How do I connect the generator to my home’s electrical system?

A: Detailed instructions for connecting the generator to a home’s electrical system can be found in the user manual. Ensure you follow all safety precautions.

XP13000X
USER MANUAL

This manual provides information regarding the operation and maintenance of these products. We have made every effort to ensure the accuracy of the information in this manual. We reserve the right to change this product at any time without prior notice.

5800 Ontario Mills Pkwy Ontario, CA 91764 USA
www.duromaxpower.com
Call our Customer Care Team Toll Free 8-5 pm PST Mon-Fri
844-DUROMAX

For more information and resources on this model scan the QR code below to link to our website product information page.

THE DUROMAX WAY
The DuroMax Way is more than just a brand, it is our understanding and appreciation of just how important power can be to someone without it…

DUROMAX FOR HOME
Electricity in our home not only provides comfort but safety as well. From keeping the heat or A/C on to keeping our food cold, power is essential to our daily lives. Inevitability when disaster strikes and we are left without power for a prolonged period of time, our way of life is put at risk. This is by far the most critical time for reliable portable power.

DUROMAX FOR WORK
On the job site, portable power allows you the ability to get work done in remote locations when traditional power sources are usually unavailable. Equipment like table saws, sanders, and work lights are a necessity and portable power can play a critical role in getting a job done successfully and efficiently.

DUROMAX FOR PLAY
Camping outdoors in a remote location can get one in touch with nature and allow them to forget the stress of the day to day grind. Here portable power can provide comfort as well as safety. With portable power, you can keep your cell phone charged, light up your campsite, or even brew a cup of coffee, all while being miles from civilization.

The DuroMax Way is a commitment to excellence. This vision is focused on the quality, reliability, and durability of our products combined with outstanding customer service. We understand that having dependable power whenever and wherever you need it provides comfort, safety, and peace of mind. It is through this philosophy that DuroMax achieves our vision of…

6

INTRODUCTION

DuroMax Power Equipment is headquartered in Ontario, California and is the industry’s leader in Dual Fuel portable generator technology. In addition to a full assortment of portable generators ranging from digital inverters to large 15,000-watt portable standby units, our product line includes pressure washers, engines, pumps, and accessories. The foundation of our company is built on quality, reliability, durability, and customer service. At DuroMax our vision is simple, we are committed to Powering Everyone… Anywhere!
STOP
Please do not return to the store.
DuroMax representatives are ready to help you with any questions, concerns, or issues about your new product. We can guide you through assembly, start up, and how to operate your new generator. We want you to be able to put your new generator to use right away!
CALL US BEFORE YOU CONSIDER RETURNING THE PRODUCT!
TOLL-FREE 1-844-DUROMAX
Notice Regarding Emissions
Engines that are certified to comply with U.S. EPA emission regulations for SORE (Small Off-Road Equipment), are certified to operate on regular unleaded gasoline and may include the following emission control systems: (EM) Engine Modifications and (TWC) Three-Way Catalyst (if so equipped).
7

GENERAL SAFETY PROCEDURES

SAFETY ALERT SYMBOL
The safety alert symbol is used with one of the safety words (DANGER, WARNING, or CAUTION) to alert you of hazards. Please pay attention to these hazard notices both in this manual and on the engine.
Please familiarize yourself with the following safety symbols and words:
DANGER: Indicates a hazard that will result in serious injury or death if instructions are not followed.
WARNING: Indicates a strong possibility of causing serious injury or death if instructions are not followed.
CAUTION: Indicates a possibility of personal injury or equipment damage if instructions are not followed.
DANGER: This generator produces poisonous carbon monoxide gas when running. This gas is both odorless and colorless. Even if you do not see or smell gas, carbon monoxide may still be present. Breathing this poison can lead to headaches, dizziness, drowsiness, and eventually death.
Use outdoors ONLY in non-confined areas. Keep several feet of clearance on all sides to allow proper ventilation of the generator.
WARNING: The exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.
WARNING: This generator produces heat when running. Temperatures near exhaust can exceed 150°F (65°C).
Do not touch hot surfaces. Pay attention to warning labels on the generator denoting hot parts of the machine.
Allow generator to cool several minutes after use before touching engine or areas which heat during use.
8

WARNING: This generator may emit highly flammable and explosive gasoline vapors, which can cause severe burns or even death. A nearby open flame can lead to an explosion even if not directly in contact with gasoline.
Do not operate near an open flame. Do not smoke near the generator. Always operate on a firm, level surface. Always turn the generator off before refueling. Allow generator to cool for at least 2 minutes before removing the fuel cap. Loosen
cap slowly to relieve pressure in the tank. Do not overfill the gas tank. Gas may expand during operation. Do not fill to the top
of the tank. Always check for spilled gas before operating. Empty the gasoline tank before storing or transporting the generator. Before transporting, turn the fuel valve to the off position and disconnect
the spark plug.
WARNING: This generator produces a powerful voltage, which can result in electrocution.
ALWAYS ground the generator before using it (see the “Grounding the Generator” portion of the “PREPARlNG THE GENERATOR FOR USE”).
The generator should only be plugged into electrical devices, either directly or with an extension cord. NEVER connect to a building electrical system without a qualified electrician. Such connections must comply with local electrical laws and codes. Failure to comply can create a backflow of power, which may result in serious injury or death to utility workers.
Use a ground fault circuit interrupter (GFCI) in highly conductive areas such as metal decking or steelwork. GFCls are available in-line with some extension cords.
Do not use uncovered in rainy or wet conditions. Do not touch bare wires or receptacles (outlets). Do not allow children or non-qualified persons to operate.
9

GENERAL SAFETY PROCEDURES
In addition to the above safety notices, please familiarize yourself with the safety and hazard markings on the generator.

DANGER

DO NOT OVERFILL

1.5″

THE GAS TANK

OVERFILLING CAN RESULT IN A FIRE, EXPLOSION, OR DEATH.

10

CAUTION HIGH TEMPERATURE

DON’T

TOUCH

DANGER HOT EXHAUST KEEP SAFE DISTANCE

BURN RISK

CARBON MONOXIDE

SAFE DISTANCE

DON’T

TOUCH

11

CARBON MONOXIDE SAFETY
Carbon Monoxide
Generators are convenient, but they can also be dangerous. All fuelburning appliances and equipment release a poisonous gas called carbon monoxide.
Carbon monoxide (also known as CO) can be dangerous for humans and pets, even in small amounts, because it blocks oxygen from getting into your body. Carbon monoxide poisoning can lead to death in a very short time. It is odorless, tasteless and invisible, so you may be exposed without knowing it. That is why carbon monoxide is sometimes called “the silent killer.”

CO-ALERT

Description
The DuroMax CO-ALERT system was created to protect our customers and their families from dangerous carbon monoxide. Just like the detector for your home the COALERT tests the air for to keep you safe and healthy.

CO Detected
If dangerous carbon monoxide levels are detected: The indicator will light red. The engine will shutdown. The engine will not restart for 5 minutes.
Maintenance Required
If an error in the CO-ALERT system is detected the indicator will light yellow. Please contact DuroMax service at 844-DUROMAX for assistance.

12

As the only safe way to use a portable generator, taking your generator outside is absolutely mandatory to keep your family safe from carbon monoxide. But there’s even more you can do. By educating yourself about all carbon monoxide risks, you’ll be better prepared to protect your family from this colorless, odorless threat. Visit takeyourgeneratoroutside.com for more information.

UNIT AND PURCHASE INFORMATION

Serial Number

Serial number
The serial number is located on the engine block, above and to the left of the oil fill.

Serial number format
The serial number will be shown in two parts. The engine model, followed by the serial number. Engine Model: Serial Number:
STAPLE RECEIPT HERE
A purchase receipt may be necessary for warranty parts or service in the future. If you have a paper receipt, staple it here for easy reference. If you purchased the unit online, save the email receipt where you can access it, and record your details here for convenience in the future. Purchase Date: ____ Order Number: ____ Retailer Name:


14

GENERATOR COMPONENTS
To help you get familiar with your new DuroMax generator, please see this component section for easy reference on all the generator’s individual features.
15

GENERATOR COMPONENTS

4. Fuel Tank

5. Power Panel

3. Fuel Valve 2. Air Cleaner

6. Handles 7. Battery

1. Recoil Start

8. Oil Fill and Dipstick

1. Recoil Start ­ Easy pull recoil start to start the engine without the electric start. 2. Air Cleaner – A removable, cleanable, oiled, element that cleans the air going into the engine. 3. Fuel Valve – On/Off valve that allows gasoline to the fuel switch. 4. Fuel Tank – All metal 8.3 gallon gasoline fuel tank. 5. Power Panel – Contains the start switch, plugs, meters, and circuit breakers. 6. Handles – Longest handles of any DuroMax model allow easy movement across any surface 7. Battery – 12V DC battery that powers the electric start system. 8. Oil Fill and Dipstick – Use to add or check the oil. 9. Engine Switch ­ Push button start switch. Press for 1 second to start the generator. Hold for 3
seconds to stop the generator. 10. Charging Light – Will light when the generator is charging the on-board battery. 11. Low Oil Alert ­ Will light only if the generator shuts down due to low oil. 12. Battery Switch ­ Prevents battery discharge during storage.
16

11. Low Oil Alert 12. Battery Switch

10. Charging Light

13. Idle Control

9. Engine Switch

15. Multimeter 14. Circuit Breaker

16. CO-ALERT

20. 120V 3-Prong Twist Lock 17. 50A Receptacle 18. 240V 4-Prong Twist Lock
19. 120V 3-Prong GFCI Receptacle

13. Idle Control – Slows the engine to save fuel and lower noise when no load.
14. Circuit Breaker – Protects the panel from overload and short circuits.
15. Multimeter ­ Displays voltage, hertz, and time running.
16. CO-ALERT – Shuts down the engine in the event of CO buildup.
17. 50A Receptacle – Use to connect electrical devices that run 120 or 240 volt, 60Hz, single-phase, AC current (NEMA 14-50).
18. 240V 4-Prong Twist Lock – Use to connect electrical devices that run 120 or 240 volt, 60Hz, single-phase, AC current (NEMA L14-30).
19. 120V 3-Prong GFCI Receptacle – Use to connect electrical devices that run 120 volt, 60Hz, single-phase, AC current (NEMA 5-20).
20. 120V 3-Prong Twist Lock – Use to connect electrical devices that run 120 volt, 60 Hz, singlephase, AC current (L5-30).

17

PACKAGE CONTENTS

Your generator comes with the items listed below. Please check to see that all of the following items are included with your generator.

Double-Sided Screw Driver
Phillips and slot blade screwdriver used for generator
maintenance.

Spanner
Assorted wrenches used in generator maintenance and
assembly. 10mm/12mm, 13mm/15mm, and 17mm/19mm.

Spark Plug Wrench
Used in spark plug maintenance, inspection, and
installation.

Oil Funnel w/ Hose
Used to add oil to the generator without messy spills.

Plug Ends
Plug heads for the receptacles found on the generator are included to make or rewire your own cords.

Note: Actual tools may differ in appearance or design from the image shown.

18

GENERATOR SETUP

Proper setup of your generator will get you going as soon as possible while making sure you and your equipment are safe and cared for.
19

20

GENERATOR SETUP
Step 1 – Remove Shipping Braces
1. Unpack
a. Remove the generator from the box. b. Place the largest piece of packing foam on a flat surface. c. Flip the generator upside down on the pad.
CAUTION: NEVER attempt this if you have put fuel or oil in the generator.
2. Remove braces
a. The shipping braces prevent engine movement during shipment. Flip the generator over and remove the brightly colored braces between the motor and the frame, and the wood brace under the generator.
Note: Shipping braces can be thrown away, they will not be needed again.
21

GENERATOR SETUP (CONTINUED)
Step 2 – Wheel Kit Installation (Optional)
1. Install support legs
a. Secure the support legs to the frame with the provided lock nuts.
2. Install wheel axles
a. Place the smallest washer onto the wheel axle bolts. b. Insert wheel axle bolts through the frame and
secure with the provided nut and wrenches.
3. Install inside wheel washers
a. Place one of the large washers onto the axles.
4. Install wheels
a. Place the wheels onto the axles.
22

5. Install outside wheel washers
a. Place the other large washers onto the axles.
6. Install cotter pins
a. Place the cotter pin through the hole at the end of the axle and bend it out to secure the wheel.
7. Install handles
a. Attach the handles to the brackets on the frame using the provided bolts and nuts. CAUTION: Do not over-tighten the handles, it will prevent free movement.
8. Flip over assembled
a. Flip the assembled generator over onto its wheels and support brackets.
23

GENERATOR SETUP (CONTINUED)
Step 3 – Connect the Battery
1. Remove the battery cover
a. Remove the battery cover plate using the wrench from the toolkit.
2. Locate the negative cable
a. Locate the negative battery cable above and behind the battery. One side is connected to ground and the other end needs to be connected to the battery.
b. Route the free end to the negative battery terminal.
3. Connect the negative cable
a. Push the black rubber boot up the wire to expose the connector.
b. Securely connect the free end of the battery cable to the negative battery terminal using the screw and nut from the battery with the screwdriver and wrench from the toolkit.
4. Reinstall the battery plate
a. Cover the connected terminal with the black rubber boot.
b. Reinstall the battery cover plate using the wrench from the toolkit.
24

Step 4 – Adding Oil

The generator requires engine oil to operate properly. The generator, when new from the package, contains no oil in the crankcase*. You must add the proper amount of oil before operating the generator for the first time. This amount is equal to the oil capacity of the engine crankcase:

Model Number Engine Oil Capacity

XP13000X 40.5 fl. oz. (1.2L)

WARNING: Do not apply engine oils with additives or 2-stroke gasoline engine oils; they don’t have enough lubrication and may shorten the engine’s service life.

Engine oil recommended: SAE 10W-30. Viscosity varies with regions and temperatures. Choose your oil viscosity using the chart to the left.

  • A small amount of oil from factory testing may be present on arrival. * Synthetic oil may be used after the 8 hour initial break-in period. Using synthetic oil does not increase the recommended oil change interval. Full synthetic 5W-30 oil will aid in starting in cold temperatures <5ºC (41ºF).
    Add oil
    a. Make sure the generator is on a level surface.
    b. Unscrew the oil filler/dipstick cap from the engine.
    c. Using a funnel, add the appropriate amount of oil into the crankcase. You will know the crankcase is full when the oil level has reached the lower lip of the opening you have just poured the oil into.
    d. Replace the oil filler cap.

WARNING: Do not overfill the crankcase. This may damage the motor and shorten the overall life of your generator.

25

GENERATOR SETUP (CONTINUED)

Step 5 – Adding Gasoline (Optional)

Add gasoline
a. Make sure the generator is on a level surface.
b. Unscrew gas cap and set aside (NOTE: the gas cap may be tight and hard to unscrew).
c. Slowly add unleaded gasoline to the fuel tank. Be careful not to overfill. The fuel gauge on the top of the gas tank indicates how much gasoline is in the generator gas tank.
d. Replace fuel cap and wipe up any spilled gasoline with a dry cloth.

Model Number Gas Tank Capacity

XP13000X 8.3 US gal. (31L)

DANGER

DO NOT OVERFILL

1.5″

THE GAS TANK

OVERFILLING CAN RESULT IN A FIRE, EXPLOSION, OR DEATH.

WARNING: Gas can expand. Do not fill the gas tank to the very top. Leave a minimum of 1.5 in open space. Gasoline and gas fumes are highly flammable. Do not fill the tank near an open flame. Always check for fuel spills.
IMPORTANT: To ensure that the generator runs smoothly use only FRESH, UNLEADED GAS WITH AN OCTANE RATING OF 87 OR HIGHER. Never use an oil/gasoline mixture. Never use old gas. Avoid getting dirt or water in the fuel tank. Gas can age in the tank and make it hard to start up the generator in the future. Never store generator for extended periods of time with fuel in the tank.

26

Step 6 – Grounding the Generator
Attach grounding wire
a. Ground the generator by tightening the grounding nut against a grounding wire.
b. Connect the other end to a copper or brass grounding rod that’s driven into the earth.
A generally acceptable grounding wire is a No. 12 AWG (American Wire Gauge) stranded copper wire.
Grounding codes can vary by location. Please contact a local electrician to check the grounding regulations for your area.
Note: If the generator is connected to a home, then it won’t be necessary to attach the separate grounding wire and you can opt to use your home ground instead. Please see a certified electrician for further options with grounding your generator.
WARNING: Failure to properly ground the generator can result in electrocution.
High Altitude Operation At high altitudes, the standard carburetor air/fuel mixture will be too rich. The performance will decrease, and fuel consumption will increase. A very rich mixture will also foul the spark plug and cause hard starting. Operation at an altitude that differs from that at which this engine was certified, for extended periods of time, may increase emissions. High altitude performance can be improved by specific modifications to the carburetor. If you always operate your generator at altitudes above 3,000 feet (900 meters), have a dealer perform this carburetor modification. This engine, when operated at high altitude with the carburetor modifications for high altitude use, will meet each emission standard throughout its useful life. Even with carburetor modification, engine horsepower will decrease by about 3.5% for each 1,000-foot (300-meter) increase in altitude. The effect of altitude on horsepower will be greater than this if no carburetor modification is made.
When the carburetor has been modified for high altitude operation, the air/fuel mixture will be too lean for low altitude use. Operation at altitudes below 3,000 feet (900 meters) with a modified carburetor may cause the engine to overheat and result in serious engine damage.
27

28

STARTING THE GENERATOR

If this is not your first time using the generator there are still steps you should take to prepare it for operation each time you use it. IMPORTANT: At this point, you should be familiar with the procedures described in the first portion of this section entitled “GENERATOR SETUP” If you have not yet read this section, go back and read it now.
29

BEFORE YOU START YOUR GENERATOR
Step 1 – Check the Oil
Check the oil
The generator is equipped with an automatic shutoff to protect it from damage due to low oil. Nonetheless, you should check the oil level of the engine before each use to ensure that the engine crankcase has a sufficient amount.
To check the oil level:
a. Make sure the generator is on a level surface. b. Unscrew the oil filler/dipstick cap. c. With a dry cloth, wipe the oil off of the stick on the
inside of the cap. d. Insert the dipstick as if you were replacing the
cap and then remove it again. There should now be oil on the stick. If there is no oil on the stick, or oil only at the very end of the stick, you should add oil until the engine crankcase is filled (see “Adding Oil” portion of the “Maintenance” section). e. Be sure to replace the cap when finished checking oil.

Model Number Engine Oil Capacity

XP13000X 40.5 fl. oz. (1.2L)

30

Step 2 – Check the Gas Level (Optional)
Check fuel level
If running the engine on gasoline, check to see that there is sufficient gasoline in the fuel tank. The fuel gauge on top of the tank will give a rough estimate of the gasoline level. The gauge will appear white then fill red as the tank is filled.
Note: Fuel gauge may not register with less than 1/3 fuel tank full.

DANGER

DO NOT OVERFILL

1.5″

THE GAS TANK

OVERFILLING CAN RESULT IN A FIRE, EXPLOSION, OR DEATH.

WARNING: Gasoline and gasoline fumes are highly flammable. Do not fill the tank near an open flame. Always allow the engine to cool for several minutes before refueling. DO NOT overfill the fuel tank. Fuel expands when shaken or heated. ALWAYS leave
11/2″ space or more at the top of the tank. ALWAYS use fresh fuel or stabilized fuel. Old gasoline (older than 30 days) can cause
permanent damage to the fuel system. Always check for fuel spills.
31

STARTING THE GENERATOR
Starting the Generator
1. Turn breaker OFF
The breaker is located on the right side of the front power panel. Flip the breaker down to prevent accidental load when starting the generator.
2. Turn battery switch ON
The battery switch is located on the top center of the main power panel. Turn the switch “ON” to allow power to the push-button start.
3. Turn idle control OFF
The idle control is located on the top center of the main power panel. Turn the switch “OFF” to prevent the unit from trying to idle down before the engine is warmed up.
4. Start the generator
The push-button start is located on the left side of the main power panel. Press the button for 1 second and release to start the generator.
32

5. Turn breaker ON/ Connect
The breaker is located on the right side of the front power panel. Flip the breaker up to allow the power to flow to the receptacles. Connect your devices to the receptacles on the front panel. Start with the largest loads first.
CAUTION: Disconnect all electrical loads from the generator before attempting to start! WARNING: Operating the starter motor for more than 5 seconds can damage the motor. If the engine fails to start, wait 10 seconds before operating the starter again.
33

STARTING THE GENERATOR (CONTINUED)
Starting the Generator Using Recoil Start
1. Shut breaker OFF
The breaker is located on the right side of the front power panel. Flip the breaker down to prevent accidental load when starting the generator.
2. Turn battery switch ON
The battery switch is located on the top center of the main power panel. Turn the switch “ON” to allow power to the push-button start.
3. Turn idle control OFF
The idle control is located on the top center of the main power panel. Turn the switch “OFF” to prevent the unit from trying to idle down before the engine is warmed up.
4. Close choke
The choke lever is located above the air filter to the left of the recoil start. Slide the lever to the right to cut the air supply and allow more gas into the engine to start.
34

5. Pull the recoil start
The recoil start is located on the left side panel next to the air filter. Pull the recoil handle slowly until resistance is felt, then quickly pull the recoil handle until fully extended.
CAUTION: Release the recoil handle only after the cord has retracted. Releasing the recoil handle while extended may cause harm to yourself or your equipment.
6. Open choke
After the engine has started, push the choke left to the “OPEN” position as the engine warms up.
7. Turn breaker ON/ Connect
The breaker is located on the right side of the front power panel. Flip the breaker up to allow the power to flow to the receptacles. Connect your devices to the receptacles on the front panel. Start with the largest loads first.
35

36

USING THE GENERATOR

If this is not your first time using the generator there are still steps you should take to prepare it for operation each time you use it. IMPORTANT: At this point you should be familiar with the procedures described in the first portion of this section entitled “GENERATOR SETUP” If you have not yet read this section, go back and read it now.
37

USING THE GENERATOR

AC Usage

You may connect electrical devices running on AC current according to their wattage requirements.
The chart below shows the rated and surge wattage of your generator according to its model number.
The rated wattage corresponds to the maximum wattage the generator can output on a continuous basis.
The surge wattage corresponds to the maximum amount of power the generator can output for a short period of time. In addition to the rated wattage listed by the device, many electrical devices such as refrigerators require short bursts of extra power to stop and start their motors. The surge wattage ability of the generator covers this extra power requirement.

Fuel Source Gasoline

Rated (Running) Wattage 10500

Surge (Peak) Wattage 13000

The total running wattage requirement of the electrical devices connected to the generator should not exceed the rated wattage of the generator itself. To calculate the total wattage requirement of the electrical devices you wish to connect, find the rated (or running) wattage of each device. This number should be listed somewhere on the device or in its instruction manual.
If you cannot find this wattage, you may calculate it by multiplying the voltage requirement by the amperage drawn: watts = volts x amps. If these specifications are not available, you may estimate the watts required by your device by using the chart on the next page.
Once you have found the rated wattage requirement of each electrical device, add these numbers to find the total rated wattage you wish to draw from the generator. If this number exceeds the rated wattage of the generator, DO NOT connect all these devices. Select a combination of electrical devices, which has a total rated wattage lower than or equal to the rated wattage of the generator.

38

Tool or Appliance Electric water heater (40 gal) Hot plate Radial arm saw Electric stove Circular saw Air compressor (1 HP) Window air conditioner Miter saw Microwave Well water pump Reciprocating saw Sump pump Refrigerator freezer Furnace blower Computer Electric drill Television Deep freezer Garage door opener Stereo Box fan Clock radio Security system DVD player Common light bulb

Rated (Running) Watts 4000 2500 2000 1500 1500 1500 1200 1200 1000 1000 960 800 800 800 800 600 500 500 480 400 300 300 180 100 75

Additional Surge Watts 0 0 2000 0 1500 3000 1800 1800 2000 1500 1040 1200 1200 1300 0 900 0 800 600 0 600 0 0 0 0

CAUTION: The generator can only run at its surge wattage capacity for a very short time. Connect only electrical devices requiring a rated (running) wattage equal to or less than the rated wattage of the generator. Never connect devices requiring a rated wattage equal to the surge wattage of the generator.
NOTE: The above wattage figures are estimates only. Try to check the wattage listed on your electrical devices before consulting this chart.
39

Connecting the Generator to a Home
Extension cords
The most straightforward and affordable option. Zero commitment, no installation needed: Simply plug in
your appliances and go! Perfect for renters, RV/camping trips, and power on the
job-site.
Transfer switch
The safest, most effortless way to power your home. Automatically switches power over to your generator
during an outage. Requires an electrician to install. Once you choose which circuits you want to power, you’re
locked into your configuration.
Interlock kit
Choose what circuits you want to run. Requires an electrician to install, but you have the
flexibility of switching up your circuits depending on your power needs. More hands-on, and some electrical knowledge is needed so you don’t overload the generator.
41

USING THE GENERATOR (CONTINUED)
Connecting a Load to the Generator
NOTE: Be sure to attach devices to the correct receptacle (outlet). 120V devices can be directly connected to the 120V ONLY receptacles. 120V devices can be connected to the 120/240V receptacle using an appropriate adapter. 240V devices can ONLY be connected to the 240V receptacle.
CAUTION: Do not connect 50Hz or 3-phase loads to the generator.
1. Plug in devices
Plug in devices to the appropriate receptacle. When using the generator, balance the load as closely as possible. Placing more load on one side of the circuit will reduce the breaker trip period.
2. Turn breaker ON
Flip the circuit breaker up to the “ON” position to allow power to the receptacles.
3. Turn on connected devices
Start or turn on appliances, starting with the biggest loads first.
42

Choosing the Right Power Cord

Long or thin cords can drain the power provided to an electrical device by the generator. When using such cords, allow for a slightly higher rated wattage requirement for the electrical device. See the table below for recommended cords based on the power requirement of the electrical device.

AMPS 5 10 15 20 25 30 40 50

DEVICE REQUIREMENTS WATTS (120/240V) 600/1200 1200/2400 1800/3600 2400/4800 3000/6000 3600/7200 4800/9600 6000/12000
*NR = NOT RECOMMENDED

WIRE GAUGE BY LENGTH (ft.)

10

25

50

100

150

18

16

14

12

10

16

14

12

12

10

14

14

12

12

10

12

12

12

10

10

12

10

10

10

8

10

10

10

8

NR

8

8

6

6

NR

6

6

6

NR

NR

*Gauge based on twisted copper wire

From home back up to just running your electric edger and everything in- between DuroMax has the power cord for you. All DuroMax cords are 100% twisted copper wire for maximum life and reliability.

120V 15A

240V 30A 240V 50A

Length
10 ft 15 ft

14 Gauge
Single Outlet

12 Gauge

Single Outlet

Triple Outlet

Single Outlet

10 Gauge

6 Gauge

Triple Outlet

L14-30P/ 14-50P/ L14-30R CS6364 XP3010GC
XP5015GC

25 ft 50 ft 100 ft

XPC14025A XPC12025A XPC12025C XPC10025A XPC10025C XP3025GC XP5025GC XPC12050C XPC10050A XPC10050C XP3050GC XP5050GC
XPC12100A XPC12100C XPC10100A XPC10100C

43

USING THE GENERATOR (CONTINUED)
Using the Digital Multimeter
When the generator is started, the display will read the current voltage. Press the MODE button to cycle through the multimeter functions.
1. Voltage
The voltage currently produced by the generator in volts.
2. Frequency
The frequency currently produced by the generator in Hz.
3. Hours run
The number of hours the engine has currently been running.
44

4. Hours total
The number of hours the generator has been run in total.
Idle Control Usage Idle control
The idle control feature lowers the RPM of the generator when there is no load to save gas and decrease engine noise. When a load is applied, the engine will resume normal speed to provide usable power. Turn on the idle control when using intermittent loads like power tools and air compressors. The idle control feature is designed for gasoline only use.
WARNING: Power is unusable when idle control is engaged. DO NOT use the idle control function when using the generator for backup house
power. Idle control function will cause massive fluctuations in voltage and hertz. Low amperage loads may not trigger the idle up function.
45

46

MAINTENANCE AND CARE

Proper maintenance and storage of your generator is essential to ensure trouble free use of your generator when you need it. By following the maintenance and care requirements, you can keep your generator running smooth and efficient for years to come.
47

MAINTENANCE AND CARE
Proper routine maintenance of your generator is essential for safe, economical, and trouble-free operation. It will also help reduce air pollution.
WARNING: Improper maintenance, or failure to correct a problem before operation, can cause a malfunction in which you can be seriously injured or killed. Always follow the inspection, maintenance recommendations, and schedules in this instruction manual.
Make sure the engine is off before you begin any maintenance or repairs. Let the engine and exhaust system cool before touching. To reduce the possibility of fire or explosion, be careful when working around
gasoline. Use only a nonflammable solvent, not gasoline, to clean parts. Keep cigarettes, sparks, and flames away from all fuel-related parts.

Maintenance Schedule

Remember that this schedule is based on the assumption that your machine will be used for its designed purpose. Sustained high-load, high-temperature operation, or use in unusually wet or dusty conditions, will require more frequent service.

SERVICE

EVERY USE

ENGINE OIL AIR CLEANER
SEDIMENT CUP
SPARK PLUG

CHECK CHECK

SPARK ARRESTOR IDLE SPEED

CHECK

VALVE CLEARANCE FUEL TUBE

CHECK

FUEL TANK / FILTER
COMBUSTION CHAMBER

1ST MO. OR 8 HRS.
(BREAK IN)
CHANGE
CHECK

EVERY 3 MO. OR 50 HRS. OF HEAVY USE
CHANGE
CHANGE
CLEAN

EVERY 6 MO. OR 100 HRS. OF NORMAL USE
CHANGE
CHANGE
CLEAN

EVERY 12 MO. OR EVERY 3 YRS. OR

300 HRS.

500 HRS.

CLEAN / ADJUST

CLEAN / ADJUST

CLEAN

CHECK / ADJUST CHECK / ADJUST CHECK / REPLACE CLEAN

CLEAN

48

Break-In Period
As the best practice for any new combustion motor it’s recommended to perform the break in procedure as follows:
Run the generator for the first 6-8 hours on conventional oil, then change the oil. After the break-in period synthetic oil may be used.
During the break in period of the first 6-8 hours keep the generator load under 50% for optimal results.
Check and clean the air filter if necessary after the break-in period.
Maintenance Log
As a best practice it’s recommended to keep a log of the generator hours and maintenance to ensure your generator is always operating to its full potential.

Date

Generator Hours

Maintenance Performed

49

MAINTENANCE AND CARE (CONTINUED)

Checking the Oil

Check the oil
The generator is equipped with an automatic shutoff to protect it from damage due to low oil. Nonetheless, you should check the oil level of the engine before each use to ensure that the engine crankcase has a sufficient amount.
To check the oil level:
a. Make sure the generator is on a level surface. b. Unscrew the oil filler/dipstick cap. c. With a dry cloth, wipe the oil off of the stick on the
inside of the cap.
d. Insert the dipstick as if you were replacing the cap and then remove it again. There should now be oil on the stick. If there is no oil on the stick, or oil only at the very end of the stick, you should add oil until the engine crankcase is filled (see “Adding Oil” portion of the “Maintenance” section).
e. The oil will be visible in the oil fill spout when full. f. Be sure to replace the cap when finished checking
oil.

Model Number Engine Oil Capacity

XP13000X 40.5 fl. oz (1.2 L)

50

Changing the Oil

CAUTION: Worn out or dirty oil does not cool the generator properly and can lead to catastrophic engine damage.
In addition to regular oil changes, it is necessary to drain the oil from the crankcase if it has become contaminated with water or dirt.

1. Remove drain plug
Using a 12 mm hex wrench, unscrew the oil drain plug, which is located on the crankcase underneath the oil filler/dipstick cap.
Allow all the oil to drain from the generator.

2. Drain oil
Drain oil into an approved oil disposal container. Contact your local auto parts store for information on oil disposal.

3. Replace drain plug
Replace the oil drain plug and tighten with a 12 mm hex wrench.
51

MAINTENANCE AND CARE (CONTINUED)
Cleaning the Air Filter
Routine maintenance of the air cleaner helps maintain proper airflow to the carburetor. Check that the air cleaner is free of excessive dirt after every use.
CAUTION: Improper maintenance may cause less air to enter the engine or dirty air to enter the engine causing overheating and engine wear.
1. Remove the filter cover screw
Remove the filter cover screw.
2. Remove filter cover
Remove the filter cover and the sponge-like element from the casing.
3. Clean out filter casing
Wipe the dirt from inside the empty air cleaner casing.
52

4. Wash cleaner element
Wash the sponge-like elements in household dish detergent and warm water.
5. Dry cleaner element
Pat dry on a dry cloth and allow the elements to dry completely.
6. Add engine oil to elements
Soak the dry elements in a small amount of engine oil. Ring out any excess oil.
7. Replace elements in casing
Replace the sponge-like elements in the air cleaner casing and replace the cover.
53

MAINTENANCE AND CARE (CONTINUED)

Spark Plug Maintenance

SPARK PLUG
CONSULT MANUAL BEFORE REMOVING

The spark plug is important for proper engine operation. A good spark plug should be intact, free of deposits, and properly gapped.

CAUTION: Improper maintenance may cause reduced fuel economy, misfires, trouble starting, or damage to the spark plug threads.

1. Remove spark plug cap
Pull on the spark plug cap to remove it.

2. Remove spark plug
Unscrew the spark plug from the generator using the spark plug wrench included with this product.
3. Inspect spark plug
Visually inspect the spark plug. If it is cracked or chipped, discard and replace it with a new spark plug. We recommend using an F6RTC spark plug such as NGK BPR6ES.
54

4. Measure plug gap
Measure the plug gap with a gauge. The gap should be 0.7-0.8 mm (0.028-0.031 in).
5. Clean and re-gap
If you are re-using the spark plug, use a wire brush to clean any dirt from around the spark plug base and then re-gap the spark plug.
6. Install spark plug
Screw the spark plug back into its place on the generator using the spark plug wrench.
7. Replace spark plug cap
Replace the spark plug cap.
55

MAINTENANCE AND CARE (CONTINUED)
Emptying the Gas Tank
If you have been using gasoline in your generator, before storing your generator for extended periods of time you should drain your generator fuel tank of gasoline.
CAUTION: Do not store fuel from one season to another. Gasoline sold at the pump today contains additives such as ethanol that even when stored properly may damage the fuel system components.
1. Shut fuel valve OFF
Turn the fuel valve to the “OFF” position.
2. Remove fuel filter cup
Remove the fuel filter cup (see “Removing the Fuel Filter Cup” earlier in this section).
3. Empty fuel filter cup
Empty the fuel filter cup of any fuel.
56

4. Drain gas from the generator
With a funnel underneath the fuel valve to catch the gas, turn the fuel valve to the “ON” position. Drain all the gas from the generator.
5. Shut fuel valve OFF
Turn the fuel valve to the “OFF” position.
6. Replace fuel filter cup
Reinstall the fuel filter cup.
7. Store emptied gas
Store the emptied gasoline in a suitable place and add fuel stabilizer to keep fuel fresh and usable.
57

MAINTENANCE AND CARE (CONTINUED)
Cleaning the Fuel Filter Cup
1. Shut fuel valve OFF
Turn the fuel valve to the “OFF” position.
2. Remove fuel filter cup
Unscrew the fuel filter cup from the fuel valve using a wrench.
3. Clean filter cup
Clean the cup of all sediment using a rag or brush.
4. Replace fuel filter cup
Reinstall the fuel filter cup.
58

Transporting the Generator
1. Empty the gas tank
Fully drain your gas tank as shown in “Emptying the Gas Tank” on page 56-57.
2. Disconnect the spark plug
Pull on spark plug cap to disconnect spark plug from ignition wire.
CAUTION: Do not obstruct any ventilation openings and keep the generator in a cool dry area. CAUTION: Never place any type of storage cover on the generator while it is still hot.
59

MAINTENANCE AND CARE (CONTINUED)
Storing the Generator for Same Day Use
1. Turn the main breaker OFF
Move the main breaker to the “OFF” position.
2. Run the generator
Allow the generator to run for 3-5 minutes.
3. Turn the generator OFF
Hold the start button for 3 seconds to shut off the generator.
4. Turn battery switch OFF/ Store
Turn the battery switch to the “OFF” position, and store the generator.
CAUTION: Do not obstruct any ventilation openings and keep the generator in a cool dry area. 60

Storing the Generator for Use Within 30 Days
1. Turn breaker OFF and run
Follow steps 1 and 2 as shown on “Storing the Generator For Same Day Use” on page 60.
2. Shut fuel valve OFF and run dry
Shut the fuel valve “OFF” and allow generator to run until it stalls out.
3. Turn the battery switch OFF
Turn the battery switch to the “OFF” position.
4. Add fuel stabilizer and store
Add fuel stabilizer to gas remaining in tank, and store generator.
61

MAINTENANCE AND CARE (CONTINUED)
Storing the Generator for Longer Than 30 Days
1. Turn breaker OFF and run
Follow steps 1 and 2 as shown on “Storing the Generator For Same Day Use” on page 60.
2. Shut fuel valve OFF and run dry
Shut the fuel valve “OFF” and allow generator to run until it stalls out.
3. Turn the battery switch OFF
Turn the battery switch to the “OFF” position.
4. Empty the gas tank
Fully drain your gas tank as shown in “Emptying the Gas Tank” on page 56-57.
62

5. Drain the carburetor
Remove drain bolt from carburetor and drain small amount of fuel in carburetor bowl.
6. Remove spark plug
Remove spark plug as shown in “Spark Plug Maintenance” on page 54.
7. Add oil to cylinder
Add 2 tablespoons of 10W-30 motor oil directly into the spark plug hole, and pull the recoil to lubricate cylinder. After lubricating cylinder reinstall the spark plug.
8. Remove battery and charge
Remove the generator battery and place it on a 12V battery tender indoors.
63

SPECIFICATIONS
Model Number AC Rated Wattage AC Surge Wattage AC Rated Voltage
Dimensions Weight
Recommended Oil Engine Displacement
Gasoline Capacity Oil Capacity Bore Stroke Engine Speed
Oil Cooling Type Bearing Type
Cylinder Sleeve Fuel Delivery System
Valve Type Engine Type Engine Cooling Type Run Time @ 50% Starting Type Noise Level Neutral System AC Rated Frequency
AC Phase Winding Material Emissions Compliance

XP13000X 10,500 W 13,000 W 120/240V 30″L x 29″W x 26″H 240 lbs 10W-30
500 cc 8.3 gal 40.5 fl. oz. (1.2 L) 94 mm 72 mm 3600 rpm Splash Stainless steel ball bearing Cast iron sleeve Carburetor OHV 4-Stroke Forced air 8.5 hr. Electric/ Recoil <74 dB Floating 60 Hz Single 100% copper windings EPA/CARB

64

TROUBLESHOOTING

This section of the manual is to help you troubleshoot problems with your generator.
65

TROUBLESHOOTING

Problem

Description
Engine switch is “OFF”

Solution
Set engine switch to “RUN”

Fuel Valve is “OFF”

Turn the fuel valve to “ON”

Choke is open

Close the choke

The engine will not start

The engine is out of fuel Fuel is old or contaminated Spark plug is dirty

Add fuel Change fuel Clean spark plug

Spark plug is broken The generator is not level Oil is low

Replace spark plug
Move the generator to a level surface
Add/ change the oil

Engine runs, but there is no electrical output
The generator runs but does not support all electrical devices connected

The circuit breaker is “OFF”
Wiring connection is bad Device connected to generator is malfunctioning Generator is overloaded Device connected to the generator is bad The air filter is dirty

Turn “ON” circuit breaker
Replace extension cord(s)
Disconnect malfunctioning device Disconnect 1 or more items to reduce the load Disconnect malfunctioning device
Clean/ replace the air filter

66

Changing/ Inspecting the Carbon Brushes
The carbon brushes in conjunction with the AVR regulates power from the generator. The carbon brushes are wearable parts and should be inspected every 250 running hours.
1. Remove generator cover
Remove the 2 bolts of the generator cover then pull the cover off the generator.
2. Remove bolt from brush
Remove the bolt holding the carbon brush.
3. Disconnect AVR wires
Remove the two wires from the AVR on the carbon brush.
67

TROUBLESHOOTING (CONTINUED)
Changing/ Inspecting the Carbon Brushes (Cont.)
4. Install new brush
Install new carbon brush with bolt.
5. Connect AVR wires
Insert and connect the 2 wires from the AVR, be sure to connect + and ­ correctly.
6. Replace generator cover
Replace the back cover of the generator and secure it with the 2 bolts.
68

Changing/ Inspecting the AVR
The carbon brushes in conjunction with the AVR regulates power from the generator. If the generator is overheated or overloaded, the AVR may be damaged and require replacement.
1. Remove generator cover
Remove the 2 bolts of the generator cover then pull the cover off the generator.
2. Remove AVR bolts
Remove the 2 bolts holding the AVR.
3. Disconnect AVR wire clip
Disconnect the wire clip.
69

TROUBLESHOOTING (CONTINUED)
Changing / Inspecting the AVR (Continued)
4. Disconnect wires from brush
Remove the 2 wires from the AVR on the carbon brush.
5. Install new AVR
Install the new AVR with the 2 bolts.
6. Reconnect wires to brush
Insert and connect the 2 wires from the AVR, be sure to connect + and ­ correctly.
7. Reconnect the AVR wire clip
Reconnect the wire clip.
70

8. Replace generator cover
Replace the back cover of the generator and secure it with the 2 bolts.
71

WIRING DIAGRAM
72

73

WARRANTY

5-year Warranty
All DuroMax Power Equipment warrant the original purchasers to a 5-year Parts Warranty (Residential Use ONLY: Unusually heavy or commercial use is covered for a period of 1-year) in the event of failure due to defects in electrical or mechanical components. Freight on any items submitted for replacement or repair under the Warranty is the responsibility of the equipment owner. This warranty is non-transferable and only valid to the original purchaser.
Warranty Exclusions
The DuroMax Power Equipment warranty does not cover repairs or returns when the fault is: Normal Wear and Tear, Installation Use or Maintenance Services, Cosmetic defects, Accessories, Failures due to acts of God or Natural Disasters, or problems related to/from aftermarket or nonOEM parts.
Warranty Limitations
DuroMax Power Equipment does not claim or hold any obligation to loss of time, freight charges, use of the product, or any incidental damages from the use of this product. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED.
U.S. FEDERAL AND CALIFORNIA EMISSIONS CONTROL WARRANTY STATEMENT YOUR WARRANTY RIGHTS AND OBLIGATIONS
The U.S. Environmental Protection Agency (EPA), California Air Resources Board, and DuroMax Power Equipment are pleased to explain the emissions control system’s warranty on your 2022/2023 small off-road engine.
In California, new small off-road engines must be designed, built, and equipped to meet the State’s stringent anti-smog standards. DuroMax Power Equipment must warrant the emissions control system on your small off-road engine for the period listed below provided there has been no abuse, neglect, or improper maintenance of your small off-road engine leading to the failure of the emission control system.
Your emissions control system may include parts such as: carburetors or the fuel injection system, ignition system, catalytic converters, fuel tanks, fuel lines (for liquid fuel and fuel vapors), fuel caps, valves, filters, clamps, connectors, and other associated components. Also, included may be hoses, belts, sensors, and other emission-related assemblies.
Where a warrantable condition exists, DuroMax Power Equipment will repair your small off- road engine at no cost to you including diagnosis, parts, and labor.
74

MANUFACTURER’S WARRANTY COVERAGE: This emissions control system is warranted for two years. If any emissions-related part on your small off-road engine is defective, the part will be repaired or replaced by DuroMax Power Equipment.
OWNER’S WARRANTY RESPONSIBILITIES: As the small off-road engine owner, you are responsible for performance of the required maintenance listed in your owner’s manual. DuroMax Power Equipment recommends that you retain all receipts covering maintenance on your small off-road engine, but DuroMax Power Equipment cannot deny warranty coverage solely for the lack of receipts or your failure to ensure the performance of all scheduled maintenance.
As the small off-road engine owner, you should be aware that the DuroMax Power Equipment may deny you warranty coverage if your small off-road engine or a part has failed due to abuse, neglect, or improper maintenance or unapproved modifications.
You are responsible for presenting your small off-road engine to a DuroMax Power Equipment distribution center or service center as soon as the problem exists. The warranty repairs shall be completed in a reasonable amount of time, not to exceed 30 days.
If you have any questions regarding your warranty coverage, contact us at 844-387-6629 or email support@duromaxpower.com.
DEFECTS WARRANTY REQUIREMENTS: The warranty period begins on the date the engine or equipment is delivered to an ultimate purchaser and extends for a period of Two Years.
GENERAL EMISSIONS WARRANTY COVERAGE: DuroMax Power Equipment warrants to the ultimate purchaser and each subsequent owner that the engine or equipment is:
1. Designed, built, and equipped to conform with all applicable regulations adopted by the Air Resources Board; and
2. Free from defects in materials and workmanship that causes the failure of a warranted part for a period of two years.
The warranty on emissions-related parts will be interpreted as follows: 1. Any warranted part that is not scheduled for replacement as required maintenance in the Owner’s Manual must be warranted for the warranty period stated above. If any such part fails during the period of warranty coverage, it must be repaired or replaced by DuroMax Power Equipment according to Subsection (4) below. Any such part repaired or replaced under the warranty must be warranted for a time not less than the remaining warranty period.
75

WARRANTY (CONTINUED)
2. Any warranted part that is scheduled only for regular inspection in the Owner’s Manual must be warranted for the warranty period stated above. A statement in such written instructions to the effect of “repair or replace as necessary” shall advise owners of the warranty coverage for emission related parts. Replacement within the warranty period is covered by the warranty and will not reduce the period of warranty coverage. Any such part repaired or replaced under warranty must be warranted for a time not less than the remaining warranty period.
3. Any warranted part that is scheduled for replacement as required maintenance in the Owner’s Manual must be warranted for the period prior to the first scheduled replacement point for that part. If the part fails prior to the first scheduled replacement, the part must be repaired or replaced by the engine manufacturer according to Subsection (4) below. Any such part repaired or replaced under warranty must be warranted for a time not less than the remainder of the period prior to the first scheduled replacement point for the part.
4. Repair or replacement of any warranted part under the warranty must be performed at no charge to the owner at a warranty station.
5. Notwithstanding the provisions of Subsection (4) above, warranty services or repairs must be provided at all manufacturer distribution centers that are franchised to service the subject engines.
6. The owner must not be charged for diagnostic labor that leads to the determination that a warranted part is in fact defective, provided that such diagnostic work is performed at a warranty station.
7. The manufacturer is liable for damages to other engine components proximately caused by a failure under warranty of any warranted part.
8. Throughout the emission control system’s warranty period stated above, the manufacturer must maintain a supply of warranted parts sufficient to meet the expected demand for such parts and must obtain additional parts if that supply is exhausted.
9. Manufacturer-approved replacement parts that do not increase the exhaust or evaporative emissions of the engine or emissions control system must be used in the performance of any warranty maintenance or repairs and must be provided without charge to the owner. Such use will not reduce the warranty obligations of DuroMax Power Equipment.
10. Add-on or modified parts that are not exempted by the Air Resources Board may not be used. The use of any non-exempted add-on or modified parts will be grounds for disallowing a warranty claim made in accordance with this Article. DuroMax Power Equipment will not be liable under this Article to warrant failures of warranted parts caused by the use of an add-on or modified part.
11. DuroMax Power Equipment shall provide any documents that describe warranty procedures or policies within five working days of request by the Executive Officer.
76

Exhaust Emission Warranty Parts List.

Evaporative Emission Warranty Part List

1. Fuel Metering System i. Carburetor and internal parts (and/or pressure regulator or fuel injection system). ii. Air/fuel ratio feedback and control system. iii. Cold start enrichment system.

1. Fuel Tank 2. Fuel Cap 3. Fuel Line (for liquid fuel and fuel vapors)

2. Air Induction System i. Controlled hot air intake system. ii. Intake manifold.

4. Fuel Line Fittings 5. Clamps*

3. Ignition System i. Spark Plugs. ii. Magneto or electronic ignition system. iii. Spark advance/retard system.
4. Air Injection System i. Air pump or pulse valve. ii. Valves affecting distribution of flow. iii. Distribution manifold.

6. Pressure Relief Valves 7. Control Valves 8. Control Solenoids 9. Electronic Controls 10. Vacuum Control Diaphragms*

5. Catalyst or Thermal Reactor System i. Catalytic converter. ii. Thermal reactor. iii. Exhaust manifold.
6. Particulate Controls
7. Traps, filters, precipitators, and any other device used to capture particulate emissions.

11. Control Cables 12. Control Linkages 13. Purge Valves 14. Gaskets 15. Liquid/Vapor Separator

8. Electronic controls.

16. Carbon Canister

9. Vacuum, temperature, and time sensitive valves and switches.
10. Hoses, belts, connectors, and assemblies.

17. Canister Mounting Brackets
18. Carburetor Purge Port Connector

  • Note: As they relate to the evaporative emission control system.

DuroMax Power Equipment will furnish with each new engine written instructions for the maintenance and use of the engine by the owner
77

CUSTOMER SERVICE

DuroMax Power Equipment is committed to ensuring that our products perform when they need to. Our generators are your lifeline in the event of an emergency. Should you have any problems, please contact our customer service department:
DUROMAX POWER EQUIPMENT 5800 Ontario Mills Parkway Ontario, CA 91764
Customer Service: 844-DUROMAX Customer Service Hours: 8-5 pm PST Mon-Fri
Website: www.duromaxpower.com Email: customerservice@duromaxpower.com
78

5800 Ontario Mills Parkway Ontario, CA 91764 United States 844-DUROMAX
REV: XP13000X-06172022

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals