Dual Sensor
Water/Soap Dispenser
Installation Manual
750EFDMSDBK / 750EFDMSDC
750EFDMSDBK Dual Sensor Water Soap Dispenser
To assure that the product operates properly, please make sure to follow all
procedures within this instruction manual.
Product Specs:
- Operating Power: 6V / 2A
- Operating Water Pressure: 10 to 100 PSI
- Soap Dispensing Time: 0.5-2 seconds (Factory setting is 2 seconds.)
- Soap Reservoir Capacity: 1.5L (Only use foaming soap)
- Sensor Distance: 1¼-6 in. (Factory setting is 4 in.)
- Response Time: 0.2 seconds
- Shut-Off Time: 1 seconds
- Operating Temperature: 5-70°C / 41-158°F
Faucet Body Component List
1. Spout Body
2. Faucet Sensor
3. Spout
4. Soap Sensor
5. Soap Spout
6. Base Gasket
7. Gasket
8. Fixation Washer| 9. Fixation Nut
10. Tightening Screw
11. Outlet Hose
12. Soap Tube
13. Sensor Cable
for Soap (White)
14. Sensor Cable for Faucet (Black)
---|---
Control Module Component List
15. Dial Cover
16. Outlet for Water
17. Soap Outlet
18. Sensor Connector for Soap Dispenser
19. Sensor Connector for Faucet
20. Soap Dispenser Rest/Purge Button
21. Soap Dispenser Setting DIP Switch
22. Faucet Reset/ Purge Button| 23. Power Inlet for AC Adapter
24. Inlet for Soap (Black Tube)
25. Water Inlet
26. Fixation Tab
27. Filter
34. Mixing valve, Hot and Cold Water Hoses
35. Rubber Washer
36. Black Tube
37. Clip Fastener
---|---
Soap Canister Component List
28. Soap Outlet to Control Module
29. Soap Canister Mount
30. Fixation Pin| 31. Mount Holes
32. Re-filler Cap
33. Canister Fixation Hook
---|---
Installation Diagram
Please note that actual installation may differ based on actual
application.
Installation Diagram
-
Shut off water valve.
-
Thread the wires and hoses through your counter hole. Make sure spout body and base gasket are flat on the counter.
-
Tightly secure the spout body by using the fixation washer, gasket, nut and screw (7, 8, 9, 10).
-
Secure the control module to the wall using the provided template.
-
Make sure the control module is tightly fastened.
-
Tightly connect mixing valve (34) to water (25) inlet of the control module.
-
Tightly connect the hot water hose (red) to the hot side of mixing valve and do the same for the cold water hose (blue). DO NOT BEND THE HOSES.
-
Connect the provided rubber washer (35) to the outlet for water (16) on the control module and tighten the outlet hose (11) to it. MAKE SURE TO USE THE PROVIDED RUBBER WASHER.
-
Connect tightly the head of sensor cable for soap (white) of the spout body (13) to the sensor connector for soap dispenser (18) of the control module.
-
Connect tightly the head of sensor cable for faucet (14) of the spout body to the sensor connector for faucet (19) of the control module. ATTENTION:
Align the direction of the arrow of each head between spout body and control module. Make sure each head of spout body is connected correctly to each head of control module. -
Connect soap tube (12) of spout body to soap outlet (17) of the control module and fit tightly by using the provided clip fastener (37). Soap canister mount installation.
-
Drill a screw hole in the wall by using “template for soap canister mount.”
-
Screw in the soap canister mount (29) and make sure it is tightly fastened and does not wobble.
-
Connect the provided black tube (36) to soap outlet (28) to control module of soap canister and fit tightly by using the provided clip fastener (37).
Connect the other side of the black tube to the inlet for soap of control module (24) and fit tightly by using the provided clip fastener (37). -
Open the refill cap (32) and pour foaming soap into soap canister. After refilling, replace refill cap.
NOTE: ONLY USE FOAMING SOAP. -
Place the soap canister on the soap canister mount (29).
-
Insert the fixation pin (30) into the fixation tab at the bottom of soap canister.
-
Connect AC adapter to the the power inlet (23) of the control module.
The control module will start adjusting sensing distance when power on. Manual sensor distance adjustments may be required.
System Setup
-
Remove the Dial Cover.
-
Setting the Faucet Sensor Distance a. Press and hold the faucet system reset/purge button (22) for about 5-7 seconds to clear CPU setting memory, LED on sensor will turn on and stay lit to enter setting mode.
b. Release button, LED will turn off, place your hand at desired sensing distance, LED is flashing and wait until it stays lit to complete new setting.
c. If your hand leaves sensing position range, water delay will cut off after 2 seconds. Please reset to shorten sensing distance and ensure water cut off time adjusts to 1 second.
d. Remove your hand and test new setting.
e. Factory default sensing distance is 4 in. -
Soap Dispenser Sensor Setup
Distance setting:
a. Press and hold soap system reset/purge button (20) for 2 seconds (LED on sensor is flashing).
b. Press the reset/purge button again to enter setup mode, Place your hand at the desired sensing distance, LED will flash when the new setting is complete.
c. Test the new setting.
Continuously dispensing soap setting:
a. Press and hold the soap system reset/purge button (20) for 5 seconds (LED on sensor stays lit) to activate continuously dispensing soap.
b. If want to stop dispensing soap, press and hold soap system reset/purge button (20) again for 2 seconds.
Important note: The soap dispenser will dispense soap automatically for one
time every 12 hours to prevent clogging.
Soap system DIP switch (21) is for soap dispensing time setting, Setting chart
to the right. Factory default setting:
1 seconds. After setting, install back the dial cover.
The system is a digital system. Do NOT attempt to tamper with the electronic
components in risk of damaging the components.
Adjust the time of dispensing soap | Switch 1 | Switch 2 |
---|---|---|
0.5 seconds | Off | Off |
1.2 seconds | On | Off |
1.5 seconds | Off | On |
2 seconds | On | On |