SANUVAIR S300 OZD Garbage Room Odor Reduction Unit Commercial Instruction Manual

June 15, 2024
SANUVAIR

SANUVAIR S300 OZD Garbage Room Odor Reduction Unit Commercial

SANUVAIR S300 OZD Garbage Room Odor Reduction Unit
Commercial

IMPORTANT SAFETY INSTRUCTIONS

READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS PRODUCT.

Read and follow all instructions contained in the manual before using the product. Read the maintenance instructions before opening the UV unit or system. Failure to comply with these instructions may result in injuries or damage to the UV unit or system.

NEVER EXPOSE EYES OR SKIN TO AN OPERATING UV LAMP.

  1. Installation and servicing of UV units or systems (in an air conditioning system or not) can be hazardous. Only trained and qualified service personnel should install, repair or service equipment.

  2. Untrained personnel can perform basic maintenance functions such as replacing lamp(s) and/or filter(s). All other operations should be performed by trained service personnel.

  3. The unit is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge.
    CAUTION: Unit is not a toy. Keep away from unsupervised children. Do not leave children unattended with the unit.

  4. DO NOT hang onto the UV unit or system.

  5. Some UV units or systems could be heavy: Make sure you have a minimum of 2 people to safely move or install these UV units or systems, and make sure you adopt the most ergonomic position possible (use UV unit or system handles, if applicable).
    CAUTION: Installing or maintaining heavy equipment, especially overhead, can cause back pain or other injuries.

  6. When installing or servicing an overhead UV unit or system, be careful not to fall off the stepladder. Furthermore, make sure the UV unit or system latches are always in place to prevent falling parts.
    CAUTION: Some parts of some UV units and systems may open suddenly if the UV unit or system is installed high up without its locks.

  7. Units that are obviously damaged must not be operated.

  8. CAUTION: When working on the UV unit or system, observe precautions on the literature, tags and labels attached to the UV unit or system, and all other safety precautions considered as best practices in the HVAC industry, if applicable.

  9. When applicable, local regulation may comprise more restrictive installation and/or certification requirements.
    The aforementioned requirements prevail on those of this document and the installer agree to conform to these at his own expense.

  10. Follow all the safety instructions outlined in this document and respect all local and national codes applicable.

  11.  All UV units or systems contain a UV-C source. Damage to the housing or unintended use of the UV unit or system may result in harmful UV-C leaks. UV-C may, even in little doses, cause harm to the eyes and skin.

  12. Never expose eyes or skin to an operating UV lamp.
    Therefore, before installing or performing maintenance on the UV unit or system, TURN OFF AND DISCONNECT the UV unit or system from all power sources (there may be more than one switch to disconnect) and also disconnect the HVAC system, is applicable.
    CAUTION: Electrical shock may cause injuries or possibly death. FIRST AID INSTRUCTIONS: If injured, consult a doctor.

  13. UV rays may damage certain types of filters (polymer or plastic); please keep the UV unit or system light away from shining directly on plastic.

  14. When installing or performing maintenance on the UV unit or system, it is recommended to wear safety gloves. In order to avoid reduced performance of lamp(s), do not touch lamp glass without gloves.

  15. Just like conventional fluorescent lamps, UV lamps contain a small quantity of mercury: if a lamp breaks, clean and dispose of with care. UV lamps can be disposed/recycled after use in the same way as any other fluorescent lamps. Contact and follow the specific instructions of your local and national authorities.
    15.1.Dispose of unit or system according to the specific instructions and standards of your local and national authorities.

  16. Use only specified SANUVOX branded replacement UV lamps for your UV unit or system. Use of any other lamps will void your warranty and can result in damage to the UV unit or system.

  17. Sanuvox UV units or systems are not waterproof. DO NOT INSTALL OUTDOORS OR IN WET LOCATION unless specified otherwise.

  18. Use of this unit or system supplements, but does not replace, infection control best practices. Users must follow all these practices, particularly with regard to cleaning and disinfecting surfaces.

ABOUT THE PRODUCT

The Sanuvair® S300 OZD is designed to help continuously reduce odors by drawing air through a UV chamber, helping reduce unpleasant odors emanating from putrefaction. The controller automatically turns a second lamp on and off to actively address the buildup or reduction of these odors.

For information or recommendations on how to size your specific application, please call SANUVOX at 1-888-726-8869.

COMPONENTS

How it Works
The Sanuvair® S300 OZD is comprised of a ventilator, speed selection switch, a MERV8 prefilter, two UV lamps and a photo oxidation controller. The ventilator pulls air through the unit, exposing it to the UV lamps, which reduces odors through a photo-oxidation process. Air is then circulated through the MERV8 prefilter and supplied back to the room. The photo-oxidation controller shuts one UV lamp off when not required.

A. Lamp & Ballast Access Door (Plate must be installed once lamp setup are done.)
B. LED Status Display
C. Filters and Motor Access Door
D. Door Latch
E. MERV8 Prefilter
F. Motor
G. Door Interlock Switch
H. Speed Selection Switch
I. Power Cord Connector (on the side)

ACCESSORIES & KITS

The following optional accessories and/or kits work great with your product (sold separately).

Air inlet/outlet louver(s) #MEC-LOU-1| | Accessories made to facilitate Samovar® S300 OZD standalone installation.
---|---|---
8″ Collar(s) #MSC-COL-1| | Accessories made to facilitate Samovar® S300 OZD added duct installation.

For instruction manuals or information about your optional accessories and/or kits, please call SANUVOX at 1-888-726-8869 or visit www.sanuvox.com.

SETUP & INSTALLATION

What you will need
Utility knife, scissors, wire cutters, air inlet grid (optional), air outlet grid (optional), suitable wall plugs and screws (as needed), screwdriver, pliers, two 8″ collars (optional) and suspension rods (optional).

CAUTION: Handle your product with care to avoid breaking parts. Make sure you have a free and safe space to unpack, install and setup your product. Confirm you have access to the necessary power source for the product requirements (see unit or system label). If you have any questions regarding the installation instructions, call SANUVOX at 1-888-726-8869.

What’s included
The SANUVAIR® S300 OZD, a pleated 2″ MERV8 prefilter, extra Prefilter’s for replacement (2), a UV lamp with yellow tips, a UV lamp with blue tips, the access door for the lamps (white metal plate), a photo-oxidation controller with its connection caps, 20′ of wire and a basic installation kit.

The installation kit includes: a pair of cotton gloves, 17″ mounting angles (2), a 3-prong power cord (6′) and self tapping 8/32 x 1/2 screws for the front plate (6).

Special considerations for integrated system installation

  • Verify clearance on the ductwork to mount the unity using the Forced Air/Heating Cooling system;
  • Respect minimum clearance requirement for maintenance and service;
  • Electrical power requirements;
  • Interaction between the UV air purifier unit and other mechanical devices.

Step by Step Setup | UV Lamp & Filters 

  1. Open the filters and motor access door of your SANUVAIR® S300 OZD unit: this is the large square door closed by the big black clamp.

  2. Check the filters (2): If they are covered with plastic wrap, be sure to unpack them before proceeding.

  3. Under the filter are the cardboard sleeves containing the UV lamps.
    Carefully slide the UV lamp with blue tips out from the cardboard sleeve. Be sure to wear the cotton gloves (included) ensuring the lamp is free from fingerprints.

NOTE: Fingerprints on a lamp will negatively impact the UV output of that lamp.

  1. While holding the UV lamp by its porcelain end-cap, slide it into the rectangular opening in the front of the unit (above the filter and motor access door).
    Step by Step Setup | UV Lamp & Filters

  2. Carefully push the furthest white connector onto the four pins. The plug is designed so it can only be installed one way. You may have to rotate the socket 90° to line up the pins with the holes. The connector will fit into position.

NOTE: Too much force applied from the opposite end-cap may break the lamp.

  1. Then, slide the porcelain tip through the retention clamp.
    NOTE: Make sure the lamp is horizontal in this section and not touching the metal walls.

  2. Repeat steps 3 to 6 for the second UV lamp (yellow tips) which should be placed in the front clamp.

  3. Take the access door for the lamps from the supplied accessories and position it over the rectangular opening. Secure the plate in place with the 6 screws provided for this purpose.
    Step by Step Setup | UV Lamp & Filters

  4. Close the filters and motor access door of your SANUVAIR® S300 OZD unit.

You are now ready to install your SANUVAIR® S300 OZD unit in one of the two suggested installation types.

Versatile Installations

The SANUVAIR® S300 OZD unit can be installed two ways: stand-alone (with protective grids at the air inlets and outlets) OR with added ducts (using 8″ collars).
The SANUVAIR® S300 OZD unit can be positioned horizontally or vertically, on a wall or on a ceiling (with angles and suspension rods).
Versatile Installations

Step by Step Installation | Stand-Alone

  1. Using wire cutters, cut the small metal pieces supporting the pre-cut 8″ round opening at the top of the unit and, do the same with the one undeerneath. You will need to use a blade to cut the paper on top as well as the sound-absorbing material under the unit.
    CAUTION: The metal is sharp. Gently remove this part to avoid injuring yourself.

  2. Use one of the 17″ mounting angles and secure it along the rear edge of the unit top by using the screws already in place. Then, secure the second mounting angle along the rear edge at the bottom of the unit.
    Step by Step Installation | Stand-Alone

  3. Secure the unit to the wall (vertically or horizontally) or to the ceiling, using suitable wall plugs and screws (not included). Make sure you have a power outlet nearby to plug the unit into.
    CAUTION: Your SANUVAIR® S300 OZD unit is bulky. Make sure that there are always two people to lift and handle it to avoid any injuries.

  4. Then place an air inlet grid (sold separately) over the opening you made at the top: this grid will rest against the mounting angle to lock it in place.
    Step by Step Installation | Stand-Alone

Do the same for the air outlet under the unit.

Your are now ready to install your photo-oxidation controller.

Step by Step Installation | Added Ducts

  1. Using wire cutters, cut the small metal pieces supporting the pre-cut 8″ round opening at the top of the unit and, do the same with the one undeerneath. You will need to use a blade to cut the paper on top as well as the sound-absorbing material under the unit.
    CAUTION: The metal is sharp. Gently remove this part to avoid injuring yourself.
    Step by Step Installation | Added Ducts

  2. Use one of the 17″ mounting angles and secure it along the rear edge of the unit top by using the screws already in place. Then, secure the second mounting angle along the rear edge at the bottom of the unit.

  3. Secure the unit to the wall (vertically or horizontally) or to the ceiling, using suitable wall plugs and screws (not included). Make sure you have a power outlet nearby to plug the unit into.
    CAUTION: Your SANUVAIR® S300 OZD unit is bulky. Make sure that there are always two people to lift and handle it to avoid any injuries.”

  4. Then place a 8″ collar (sold separately) over the opening you made at the top to later connect rigid pipe or 8″ flexible pipe.
    Do the same for the air outlet under the unit.

  5. Install your 8″ (rigid in aluminum or galvanized or aluminized flexible) pipes.
    Step by Step Installation | Added Ducts

Step by Step Installation | Photo-oxidation Controller

  1. Take the photo-oxidation controller out of its packaging (2 parts) and fit the sensor into the electronic board. Then determine the best location to install the controller.
    Step by Step Installation | Photo-oxidation Controller
    NOTE: The photo-oxidation controller should be installed as close as possible to the purified air outlet, on a wall, 60″ from the ground.

  2. Install the controller on the wall using the 4 velcro stickers (included) or an appropriate screw (not included).

  3. Use the supplied cable to connect your controller to your unit. If the 20′ of wire are not enough, you can use BX wiring with 3 wires.

  4. Use the connection caps (included) to connect the wires from the connector box to the same colored wires from your unit, then replace your controller cover.

  5. Turn the unit ON and wait approximately 1 tot 2 minutes for the startup phase to be completed, and for the OZD controller to calibrate. The second lamp should turn on (with the appropriate LED on the front plate).

Your new SANUVAIR® S300 OZD is now ready to operate!

OPERATION

How to Operate your Product

The Sanuvair® S300 OZD is an automatic unit: once it’s installed and plugged in, simply press the power switch to turn it ON. Wait approximately 1-2 minutes for the startup phase to be completed, and for the OZD controller to calibrate. The second lamp should turn on (with the appropriate LED on the front plate).

To access the door interlock switch and the speed selection switch, open the filters and motor access door at the front of the unit. Opening the latch on the right side of the unit will permit the door to swing open. The safety door interlock switch cut the power to the motor. If necessary the door can be removed from the cabinet hinges by holding the top part of the door with one hand and gently tapping on the bottom edge of the door with your hand to release the door from its hinges.

How to Select Speed

The Sanuvair® S300 OZD features two speeds of operation.
The speed selection switch is located inside the unit, on the front of the motor assembly.
It is recommended that the unit be operated at its highest speed at all time to maximize the benefits of the air purifier.
How to Select Speed

How to Read the LED Status Display

The Sanuvair® S300 OZD’s LED Status Display will give you real time status update about your unit and its lamps.

Normal Operation
BALLAST ON, RED: Ballast in operation, “Default Mode”.
  UV ON, AMBER: Lamp in operation, “Default Mode”.

MAINTENANCE

How to Replace Lamp

Replace UV lamp yearly for optimal odor reduction.
Replacing lamp on the Sanuvair® S300 OZD is quick and easy. Simply turn off the power source, unscrew and remove the lamp and ballast access door (plate), remove and dispose of old lamps, replace with new Sanuvox branded UV lamps, screw back the lamp and ballast access door (plate) and turn power source back on. See below for detailed step by step instructions.

CAUTION: In order to avoid reduced performance of lamps, do not touch lamp glass without gloves.

Step by Step Lamp Replacement

  1. Unscrew and remove the lamp and ballast access door to access the old lamp.
    CAUTION: Before installing or performing maintenance on the unit or system, TURN OFF AND DISCONNECT the unit or system from all power sources.

  2. Prepare the new lamp. Remove the contents from packaging. Only after you have visually inspected the UV lamp should you break the security seal on the underside of the cardboard sleeve. Be sure to wear the cotton gloves (included) guaranteeing a clean lamp free from fingerprints. Fingerprints on the lamp will negatively impact the UV output of the lamp.
    Step by Step Lamp Replacement
    NOTE: Fingerprints on the lamp will negatively impact the UV output of the lamp.

  3. While holding the new UV lamp by its porcelain end-cap, slide it into the rectangular opening in the front of the unit (above the filters and motor access door).

  4. Carefully push the white connector onto the four pins. The plug is designed so it can only be installed one way. You may have to rotate the socket 90° to line up the pins with the holes. The connector will fit into position.
    NOTE: Too much force applied from the opposite end-cap may break the lamp.

  5. Then, slide the porcelain tip through the retention clamp.
    NOTE: Make sure the lamp is horizontal in this section and not touching the metal walls.
    Repeat steps 2 to 5 for the second lamp. Always place the lamp with blue tips in the back, and the lamp with yellow tips up front.
    Step by Step Lamp Replacement

  6. Screw back in place the access door for the lamp and ballast over the rectangular opening.

How to Replace Filters

Replace prefilter every 3 to 6 months or as needed.
Check regularly to maintain maximum performance of your HVAC system.

Step by Step Filter Replacement

  1. Open the filters and motor access door at the front of the unit.
    Opening the latch on the right side of the unit will permit the door to swing open.

If necessary the door can be removed from the cabinet hinges by holding the top part of the door with one hand and gently tapping on the bottom edge of the door with your hand to release the door from its hinges.

  1. After opening the unit’s access door, grasps both edges of the filter and pull with equal force to slide it out.

  2. Unpack the new filter and place it in the unit, then close the access door.
    Step by Step Filter Replacement
    NOTE: Make sure to install filters according to air flow direction for maximum performance.

How to Replace Photo-oxidation Controller Head

Replace head every 2 years or as needed.

Step by Step Photo-oxidation Controller Head Replacement

  1. Turn off the unit.

  2. Prepare the new OZD controller head.

  3. Remove and dispose of the old OZD controller head.
    Step by Step Photo-oxidation Controller Head Replacement

  4. Connect the new OZD controller head.

  5. Turn the unit back on.

  6. Wait 1-2 minutes for the calibration period. Subsequently, the second lamp and ballast will turn on, indicated by the LEDs on the front of the unit.

How to Clean your Product
Maintenance of the unit should be perform at the regular intervals to keep the benefits of the UV air purifier.
For optimal performance, the lamp should be kept free of dust and residue deposit. Clean when necessary with mild soap or alcohol. Always spot test the cleaner to make sure it does not damage the surface.
Once a year or as needed, clean the interior of the unit (wall and motor plate), with mild non-abrasive soap. It is recommended to use products that are environmentally friendly.

CAUTION: Under no circumstance should water be sprayed or splashed onto the product.

STORAGE

The Sanuvair® S300 OZD unit is fixed installation and therefore, requires no specific storage.

ULTRAVIOLETS

Ultraviolet wavelengths (UV) emitted by Sanuvox units and systems are identical to ultraviolet produced by the sun. UVC damage nucleic acids (DNA/RNA) of microorganisms, which inactivates them. Unlike conventional UV lamps on the market, Sanuvox units and systems use a patented process that delivers a maximum dose of UV to the moving air stream or surfaces.

CAUTION: Never expose eyes or skin to an operating UV lamp.

The Sanuvair® S300 OZD has a power consumption of 230W. The product is rated at 120/240VAC, 50/60Hz.
See product label to confirm power consumption of your specific unit or system.

NOTE: IF YOU EXPERIENCE A PROBLEM, PLEASE CONTACT CUSTOMER SERVICE FIRST OR SEE YOUR WARRANTY. DO NOT RETURN THE PRODUCT TO THE ORIGINAL PLACE OF PURCHASE. DO NOT ATTEMPT TO OPEN THE PRODUCT OR TAMPER WITH ITS COMPONENTS WITHOUT CONTACTING CUSTOMER SERVICE FIRST. DOING SO MAY VOID YOUR WARRANTY AND CAUSE PERSONAL INJURY OR DAMAGE TO THE PRODUCT.

TROUBLESHOOTING

If your product is not working properly, refer to the following.

Problem Possible Cause Solution
Ballast LED #1 is OFF.
  • Defective lamp.
  • Defective ballast.

|

  • Test the lamp or replace it with lamp #2. If the lamp is functional, replace your ballast.
  • Replace your ballast.

Lamp and/or Ballast LED #2 is OFF.|

  • The lamp is defective.
  • The ballast is defective.
  •  The OZD controller is faulty.

|

  • Switch the unit off and on again. Wait for the OZD controller to calibrate (1 to 2 minutes). The lamp and ballast #2 LED lights should turn on.
  • If ballast #2 LED is off, replace ballast.
  • If the LED of lamp #2 is still off, test the lamp or replace with lamp #1. If the lamp is faulty, replace it.
  • If the two LEDs (lamp and ballast #2) are still off after replacing them, change the OZD controller.

Unit doesn’t turn ON.|

  • The power cord is not fully inserted in the unit’s connector.
  • There is no power to the electrical outlet.
  • The door interlock switch is operating.
  • Power cord is damaged.

|

  • Test the outlet to make sure there is power by plugging in another electrical appliance.
  • Check the power cord for damage and replace if damaged.

Unit operates only on one speed.|

  • There are loose wires inside electrical box.

|

  • Contact your contractor

Unit vibrates (balancing weight).|

  • An excessive dust build-up or missing on the impeller wheel.

|

  • Check for excessive dust build-up or missing on the impeller wheel.
  • Clean the interior of the unit (wall and motor plate)

Contact your contractor for all your needs in terms of replacement parts:
power cord, motor, ventilator, ballast, UV lamp, etc.

WARRANTY

You should first read all instructions before attempting to use this product.
For this warranty to be valid, keep a copy of the proof of purchase.

UV lamp 2 years
Ballast 3 years
Electric Motor 3 years
Photo-oxidation Controller 1 year

A. This limited warranty applies to repair or replacement of product found to be defective in material or workmanship. This warranty does not apply to damage resulting from abusive, unreasonable use or supplemental damage. Defects that are the result of normal wear and tear will not be considered manufacturing defects under this warranty.
SANUVOX IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY.
Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitation on how long an implied warranty last, so the above limitations or exclusions may not apply to you. This warranty gives specific legal rights, and you also may have other rights which vary from jurisdiction to jurisdiction. This warranty applies only to the original purchaser of this product from the original date of purchase.
B. At its option, SANUVOX will repair or replace this product if it is found to be defective in material or workmanship.
C. This warranty does not cover damage resulting from any unauthorized attempts to repair or from any use not in accordance with the instruction manual.
D. This warranty does not cover the filters, Prefilter or other accessories (if included), except for material or workmanship defects.

Call us toll-free at 1-888-726-8869 or email: info@sanuvox.com
Please be sure to specify product name.

NOTE: IF YOU EXPERIENCE A PROBLEM, PLEASE CONTACT CUSTOMER SERVICE FIRST OR SEE YOUR WARRANTY. DO NOT RETURN THE PRODUCT TO THE ORIGINAL PLACE OF PURCHASE. DO NOT ATTEMPT TO OPEN THE PRODUCT OR TAMPER WITH ITS COMPONENTS WITHOUT CONTACTING CUSTOMER SERVICE FIRST. DOING SO MAY VOID YOUR WARRANTY AND CAUSE PERSONAL INJURY OR DAMAGE TO THE PRODUCT.

Replacement parts for this product

BST120/277GL Ballast with multi-voltage input of 120-277VAC, 50/60Hz
LMPHGXJ105-1 T6 High Intensity 10.5″ ‘J’ shaped UV lamp (yellow tips)
LMPHXJ105 T6 High Intensity 10.5″ ‘J’ shaped UV lamp (blue tips)
FTR-10 MERV8 Prefilter or the carbon MERV8 prefilter #FTR-10A
FTR-11 HEPA filter
ELC-DET-OZD-15 Replacement head for photo-oxidation controller
FLEX0825 25′ of flexible tubing (8″ diameter)
MEC-LOU-1 Air inlet/outlet louver
MSC-COL-1 8″ collar

CUSTOMER SERVICE

TO ORDER REPLACEMENT PARTS
PLEASE CONTACT YOUR CONTRACTOR OR SANUVOX CUSTOMER SERVICE
Toll-Free Phone #: 1-888-726-8869
Email: info@sanuvox.com
Website: www.sanuvox.com
Please be sure to specify product name.

WARNING: Use only specified SANUVOX branded replacement UV lamps with your unit or system. Use of any other lamps will void your warranty and can result in damage to the unit, system and/or lamp(s)

REGISTER YOUR WARRANTY

QR Code

www.sanuvox.com 1-888-726-8869Logo

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>