DELL PowerFlex Defined Storage Software
Product Information
Specifications
- Product Name : Dell PowerFlex 4.5.x
- Release Notes : September 2023 Rev. 1.0
Introduction
This document provides information about the PowerFlex version 4.5 release.
It includes details on new features, known issues, and workarounds.
Product Description
PowerFlex is an enterprise-class, software-defined block and file storage
solution. It is deployed, managed, and supported as a single system. PowerFlex
allows for highly flexible and scalable configurations, including two-layer
(server SAN), single-layer hyperconverged setups, storage-only deployments,
PowerFlex file services, and mixed architectures within a single deployment.
PowerFlex Manager is the unified tool used for managing and operating
PowerFlex.
New Features in PowerFlex Version 4.5
Version 4.5 of PowerFlex introduces the following new features
- Support for Release Certification Matrix (RCM) version 3.7.3.0
- Support for Intelligent Catalog (IC) version 45.373.00 in PowerFlex appliance
- Support for PowerFlex_Software_4.5.0.0 in software-only PowerFlex custom node
Where to Get Help
If you require further assistance or support, please refer to the following
resources
- Dell Release Certification Matrix (RCM) Portal for certified versions of software and firmware components
- Dell PowerFlex Appliance with PowerFlex 4.x Support Matrix for firmware, software, and component support
- PowerFlex software technical documentation for additional PowerFlex software documentation
Product Usage Instructions
Supported Configurations
PowerFlex version 4.5 supports the following configurations
- PowerFlex rack with supported firmware and software
- PowerFlex appliance with Intelligent Catalog (IC) version 45.373.00
- Software-only PowerFlex custom node with PowerFlex_Software_4.5.0.0
- VxFlex Ready Node with required software packages for software-only deployments
Target Audience
This document is intended for customers, Dell Technologies teams working
with customers, and certified partners.
FAQ
-
Q: What is PowerFlex?
PowerFlex is an enterprise-class, software-defined block and file storage solution that offers flexible and scalable configurations. -
Q: What is PowerFlex Manager?
PowerFlex Manager is a unified tool used for the management and operations of PowerFlex. -
Q: What are the new features in PowerFlex version 4.5?
The new features in PowerFlex version 4.5 include support for Release Certification Matrix (RCM) version 3.7.3.0, Intelligent Catalog (IC) version 45.373.00, and PowerFlex_Software_4.5.0.0.
NOTE: A NOTE indicates important information that helps you make better
use of your product.
CAUTION: A CAUTION indicates either potential damage to hardware or loss
of data and tells you how to avoid the problem.
WARNING: A WARNING indicates a potential for property damage, personal
injury, or death.
© 2022-2023 Dell Inc. or its subsidiaries. All rights reserved. Dell Technologies, Dell, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be trademarks of their respective owners.
Introduction
This document provides information about the PowerFlex version 4.5 release, including
- Information about new features delivered in this release for PowerFlex and PowerFlex Manager
- Known issues and steps to work around them
The PowerFlex and PowerFlex Manager version 4.5 release supports
Product | Supported firmware and software |
---|---|
PowerFlex rack |
- Version 4.5 adds support for Release Certification Matrix (RCM) version 3.7.3.0.
- For the supported certified versions of software and firmware components, see the Dell Release Certification Matrix (RCM) Portal. To access the RCM portal go to the RCM Portal.
PowerFlex appliance|
- Version 4.5 adds support for Intelligent Catalog (IC) version 45.373.00.
- See the Dell PowerFlex Appliance with PowerFlex 4.x Support Matrix for supported firmware, software, and components.
Software-only, PowerFlex custom node, VxFlex Ready Node| Version 4.5 adds support for PowerFlex_Software_4.5.0.0. This is a software-only catalog that provides only the packages needed for software-only deployments. It does not include ISOs or SVM packages.
- The target audience for this document includes customers and Dell Technologies teams working with customers and certified partners.
- For additional PowerFlex software documentation, go to PowerFlex software technical documentation.
Revision history
Date | Document revision | Description of changes |
---|---|---|
September 2023 | 1.0 | Initial release |
Product description
- PowerFlex is an enterprise-class, software-defined block and file storage solution that is deployed, managed, and supported as a single system. Highly flexible and scalable, PowerFlex allows customers to mix two-layer (server SAN), single-layer hyperconverged configurations, storage-only, PowerFlex file services, and other mixed architectures within a single deployment.
- PowerFlex Manager is a unified tool that is used for the management and operations of PowerFlex.
PowerFlex version 4.5
New features in 4.5
PowerFlex release 4.5 introduces the following new features
Feature | Details |
---|---|
Dell APEX Block Storage for AWS | Dell APEX Block Storage for AWS enables you |
to deploy a PowerFlex cloud-based storage cluster in Amazon Web Services
(AWS). This deployment is a manual process.
Dell APEX Block Storage for Microsoft Azure| Dell APEX Block Storage for
Microsoft Azure enables you to deploy a PowerFlex cloud-based storage cluster
in Microsoft Azure. This deployment is a manual process.
Cloud data mobility with Dell APEX Block Storage| You can move data between
on-premises and public cloud or across regions within the public cloud using
the Dell APEX Block Storage native async replication feature.
PowerFlex cloud licensing|
- When you deploy a PowerFlex cloud-based cluster, you are provided with a free evaluation license. This license gives you 90 days to use the cloud-based storage cluster. After 90 days, the storage is preserved. However, you are not allowed to make configuration changes to the deployment. Once the evaluation license has expired, you must purchase a subscription or permanent license to continue using the cluster with the full range of capabilities.
- PowerFlex Manager now shows the start date and end date for both evaluation and subscription licenses on the License Management page. Evaluation licenses apply only to cloud deployments, whereas subscription licenses apply to both cloud and on-premises deployments.
PowerFlex support for Dell PowerEdge R660, R760, R6525, and R7625 servers|
- PowerFlex 4.5 certifies support of the following platforms for software only and custom node offerings
- Dell PowerEdge R660 and Dell PowerEdge R760 servers (Intel based)
- Dell PowerEdge R6525 and Dell PowerEdge R7625 servers (AMD based)
SAML for SSO to support cloud integration| You can configure single sign-on
(SSO) authentication through an Identity Provider (IdP) using the SAML 2.0
protocol. This makes it possible for cloud users to take advantage of SSO
capabilities.
PowerFlex NVMe/TCP connectivity| This release introduces the following
NVMe/TCP connectivity enhancements:
- Host network awareness
PowerFlex considers the host networks for resiliency. When a host is losing a network, it can still use other paths through available networks to access the storage.
- Network sets
PowerFlex supports specifying networks that might fail together. NVMe/TCP connections are allocated to the NVMe/TCP hosts through multiple network sets, offering resiliency to the failure of the network set.
- Fault set support
NVMe/TCP supports fault sets. Connections allocated to the NVMe/TCP are through targets on multiple fault sets that provide path resiliency to a fault set failure.
Feature | Details |
---|---|
- NVMe reservations support (SCSI-3 equivalent)
PowerFlex supports NVMe reservations (SCSI-3 equivalent) with NVMe/TCP.
- Persistent discovery controller
NVMe/TCP hosts connect to PowerFlex through persistent discovery, which enables automatic updates of the hosts regarding storage side changes.
- Migration to NVMe/TCP
PowerFlex provides the option to migrate workloads from SDC to NVMe/TCP on ESXi:
- Online migration using Storage vMotion (VMFS only)
- The standard way of moving storage is with Storage vMotion. Storage vMotion also supports switching protocols by migrating to a new DataStore. For more information, see the Dell PowerFlex 4.5.x Administration Guide.
- Offline migration (VMFS only)
- There is a new option for converting an existing VMFS datastore from SCSI (SDC) to NVMe/TCP without having all the data over the network. The offline migration steps are covered in the following KB article: https://www.dell.com/support/kbdoc/en-us/000213232.
NOTE: There are not standard ways to migrate Linux environments, ESXi clusters and RDMs.
PowerFlex management controller self- awareness on PowerFlex appliance and
PowerFlex rack| PowerFlex 4.5 allows self-awareness of its underlying
controller system. This includes upgrade from end-to-end and the ability to
receive alerts from issues in the PowerFlex management controller
infrastructure.
Multi-network support (available for PowerFlex appliance and PowerFlex rack)|
PowerFlex Manager now supports multiple management networks of the same type.
The supported networks are
- Hypervisor management
- PowerFlex management
- Hypervisor migration
- Replication networks
Modular (single) component upgrade| PowerFlex 4.5 changes the package in the PowerFlex rack or PowerFlex appliance catalogs to newer or older versions. This upgrade depends on customer cases that want to deviate from the Release Certification Matrix or Intelligent Catalog.
NOTE: By default, this feature is turned off and can only be enabled through an RPQ process. If applicable, contact your account team for details.
Alert intelligence and deduplication| PowerFlex Manager restricts the number
of alerts for an event to three per hour. This, in turn, eliminates duplicate
alerts for the same event and prevents display of non-actionable items.
Capture the RCM version and send to the ESE data items portal| PowerFlex
Manager facilitates sending the active RCM version to the Data Items portal.
When multiple resource groups run on different compliance files, all the
active RCM versions are sent to the Data Items portal. If PowerFlex Manager is
not managing any resource groups then, the default RCM of PowerFlex Manager is
sent to the data items section of the Embedded SupportAssist Enabler. By
default, this information is sent every Saturday at 02:00 AM UTC.
Troubleshooting bundle includes PowerFlex logs| The PowerFlex Manager
troubleshooting bundle now includes PowerFlex logs.
Login with SSH key pairs for nodes, switches, and deployments| You can use SSH
key pairs to access PowerFlex systems. When you enable SSH key pairs,
PowerFlex Manager uses public/private RSA key pairs to SSH into your nodes and
switches securely, instead of using a username and password. When you enable
SSH key pairs, PowerFlex Manager also uses RSA public/private key pairs for
operating system users and administrators during deployment operations. The
root user has no local or remote login capabilities.
Feature| Details
---|---
|
- To support login by SSH key pairs, you can enable SSH key pairs on the Node , Switch , OS Admin , and OS User credential types.
- **** This feature enhances security by blocking the root user and password. This feature is also required for Dell APEX Block Storage for AWS and Dell APEX Block Storage for Microsoft Azure.
Replacement of legacy roles with new roles in the PowerFlex Manager user interface| PowerFlex Manager has replaced the legacy roles from earlier releases with the following new roles:
- SuperUser
| SystemAdmin
| StorageAdmin
| LifecycleAdmin
| ReplicationManager
| SnapshotManager
| SecurityAdmin
| DriverReplacer
| Technician
| Monitor
| Support
Default for LACP balance setting has been changed to improve performance| The
LACP balance default setting (xmit hash policy) has been changed to 3+4. This
change removes an unbalance issue with the previous LACP setting and increases
the performance of business applications running on PowerFlex. This LACP
change applies only to new deployments. It does not change the setting for
one-time migration or upgrade scenarios.
Ability to use a nonroot user for PowerFlex system administration functions|
- You can now use a nonroot user instead of the root user for PowerFlex system administration functions. This feature enhances security by disabling the root user during operating system installation and non-disruptive updates. PowerFlex Manager allows you to specify a nonroot user when you configure a template for a compute-only, storage-only, or hyperconverged deployment. You can also use a nonroot user when adding an existing deployment. The ability to use a nonroot user applies to SLES, CentOS, and VMware ESXi, as well as PowerFlex file deployments.
- ** PowerFlex Manager allows you to use an LDAP user for PowerFlex system administration functions. When you create or edit an OS User** credential, you can optionally specify the LDAP domain. This allows you to use an Active Directory (AD) user rather than a local user for administration functions.
Ability to deploy and provision block and file with a single storage pool| You
can deploy PowerFlex block and file services using a single, shared storage
pool.
| In release 4.0, the storage pool selected at the time of a PowerFlex File
deployment was expected to be empty. A validation error was generated if there
were any volumes present on the storage pool. This validation has been
removed.
| PowerFlex no longer requires that the storage pool be a dedicated pool used
only for PowerFlex File volumes. The storage pool is now available as a shared
object for normal volume creation. If you upgrade a PowerFlex management
platform from an earlier release, the storage pool for PowerFlex File services
is configured so that it is available for normal volume creation for both
block and file usage.
| In addition, the storage high and critical threshold values now remain
unchanged after a PowerFlex File deployment. By default, the values of these
parameters are 80% and 90% respectively. You can change these default values
before performing the deployment. The values are not updated during the
deployment.
Support for vCLS datastore placement| PowerFlex Manager provides support for
vCLS datastore placement with hyperconverged and compute-only VMware ESXi
deployments. PowerFlex Manager
Feature| Details
---|---
|
- configures the allowed list of datastores for new resource group deployments. Whenever possible, it reuses the existing datastores instead of creating new ones.
- **** When you add an existing resource group, PowerFlex Manager does not create more datastores when there are already two or more datastores in the allowed list.
- You can check the vCLS datastores in the vSphere Client. Go to the hyperconverged or compute-only cluster and choose Configure > Datastores. Then, check the VCLS ALLOWED tab.
Ability to configure NVMe/TCP host network connectivity| You can configure the
data networks that are used for NVMe/TCP host connectivity. The Settings
page in PowerFlex Manager has a new section that is called System Data
Networks that provides a user interface for adding the network details. You
can configure the system data networks through the PowerFlex Manager user
interface, or through an API. An API is also available for configuring
NVMe/TCP host groups.
Support for webhooks| PowerFlex Manager enables you to register a notification
receiver for pushing alert and event messages through a webhook to a target
system. Webhooks provide a one-way system of communication that sends HTTP
requests triggered by events that occur in a source system to a destination
system. The user interface in PowerFlex Manager provides a way to configure a
webhook destination and policy so that events and alerts created or received
by PowerFlex Manager can be sent to any webhook destination.
Updated switch support (available for PowerFlex appliance and PowerFlex rack)|
PowerFlex Manager has updated its support for Cisco Nexus and Dell PowerSwitch
models. PowerFlex Manager can perform the following operations on a wide
variety of Cisco and Dell Networking switch models
- Upgrade networking operating system versions based on an RCM
- Upgrade firmware versions based on an RCM
- Report RCM compliance based on an RCM
- Identify each switch model and apply the correct firmware version to each model
The updated switch support covers the following Cisco models and NX-OS or EPLD versions
- N3172TQ (9.3.10)
- N31108TC-V (9.3.10)
- N3132 (9.3.10)
- N3164 (9.3.10)
- N9236C (9.3.10)
- N9332PQ (9.3.10)
- N93180YC-EX (10.3.1)
- N93180YC-FX (10.3.1)
- N93180YC-FX3 (10.3.1)
- N9336C-FX2 (10.3.1)
- N93240YC-FX2 (10.3.1)
- N9364C (10.3.1)
- N9364C-GX (10.3.1)
- N92348GC-X (10.3.1)
The starting point for any NX-OS upgrades to 10.3.x is 9.3.10 or higher.
The updated switch support also covers the following Dell PowerSwitch models and OS10/OS9 versions:
- S4148T (10.5.4.5)
- S4148F (10.5.4.5)
- S5048F (9.14.1.14)
- S5224F (10.5.4.5)
- S5248F (10.5.4.5)
- S5232F (10.5.4.5)
Feature | Details |
---|---|
S5296F (10.5.4.5) |
The starting point for any OS10 upgrades to 10.5.4.5 is 10.5.3.x or higher.
REST API support for fault sets with SDTs| PowerFlex provides the ability to
add a storage data target (SDT) to a fault set by using a REST API. In
addition, for any fault set deployment, PowerFlex adds SDTs to the fault set.
Once added, an SDT cannot be removed from a fault set.
PowerFlex file services enhancements|
- PowerFlex Manager introduces the following PowerFlex file services enhancements
- Single namespace
- Ability to create a global namespace (GNS) supported by the NAS cluster with a single export
- Allows all hosts with correct access permission to access existing and newly added file systems to the namespace without needing to explicitly mount them on each client
- Consists of several file systems that may be SMB or NFS
- Common Event Publishing Agent (CEPA)
- Support for CEPA, which is part of the Common Event Enabler (CEE) package
- Ability to receive file event notifications
- Ability to use CEPA to see events on some/all of my NFS and SMB file systems
- Enhanced scalability
- Updated scalability limits for file services objects running on PowerFlex For complete details on all product limits, see the Dell PowerFlex 4.5.x Technical Overview.
Changed features
This section lists changes to existing features and features that are no longer supported in PowerFlex 4.5.
Operating system highlights
PowerFlex 4.5 enables support of the following operating systems
- Red Hat Enterprise Linux 9.2 or 8.8
- SLES 15.5
- ESXi 8.0 for NVMe over TCP client and NAS client
RFCache
The RFCache feature was removed in 4.0. Any customer using RFCache with
3.6.x.x must first remove the RFCache configuration and packages before
initiating an upgrade.
VASA support
- VASA support is not available in this release. VASA support is a future road map item.
- Customers needing VASA support should continue using PowerFlex 3.6.x.x with the latest patch.
Installation and upgrade considerations
You can install and configure PowerFlex version 4.5, or you can upgrade from
PowerFlex version 3.6.x to version 4.5. See the Dell PowerFlex 4.5 Install and
Upgrade Guide for detailed instructions on installing or upgrading.
Licensing
PowerFlex use requires a license. Contact your Dell account representative to
purchase a license for PowerFlex.
Upgrade
The following table lists the versions from which the upgrade can be performed
P o w e r F l e x / VxFlex OS /
ScaleIO base version| Upgrade path| Supporting documentation
---|---|---
v3.6.0.x| One-step upgrade flow
- Upgrade to v4.5.x
| Dell PowerFlex 4.5.x Install and Upgrade Guide
v4.0.x| Two-step upgrade flow
- Upgrade to v4.0.2
- Upgrade to v4.5.x
| Dell PowerFlex 4.5.x Install and Upgrade Guide
v3.0, v3.0.0.x, v3.0.1.x,
v3.5.x
| Two-step upgrade flow
- Upgrade to v3.6.0.x
- Upgrade to v4.5.x
| Upgrade PowerFlex to v3.6 Guide
v2.0.1.4, v2.6.x| Three-step upgrade flow
- Upgrade to latest version of v3.0.1.x
- Upgrade to v3.6.0.x
- Upgrade to v4.5.x
| Upgrade VxFlex OS to v3.0.x Guide Upgrade PowerFlex to v3.6 Guide
In release 4.5, PowerFlex supports CloudLink 7.1.7 and 7.1.8.
Supported operating systems
For a list of supported operating systems, see the Storage section of the Dell
Technologies Simple Support Matrices at
https://elabnavigator.dell.com/eln/modernHomeSSM.
SDC compatibility
By design, the PowerFlex SDC in this release is compatible with newer and
previously released systems that are currently supported (for example, VxFlex
OS v3.0.1). In addition, the PowerFlex system (backend) in this release is
backward and forward compatible with previously released SDC versions that are
currently supported.
Some limitations may apply to mixed-version systems, such as
- Replication is not supported on SDC releases earlier than PowerFlex v3.5.
- The CHAP component authentication feature cannot be enabled unless every MDM, SDC and SDS in the system is at least version 3.5, and conversely, if the feature is enabled, no pre-v3.5 SDCs can be added.
- Fine granularity storage pool-based volumes cannot be mapped to a ScaleIO/VxFlex OS v2.x SDC.
- Snapshot policy management is not available with SDC releases earlier than VxFlex OS v3.0.
Known issues in 4.5
- The Dell engineering team is working to resolve known issues.
- Before getting started with PowerFlex and PowerFlex Manager, review the following known issues in version 4.5
CLI
Issue ID | Symptom | Recommended action |
---|---|---|
SCI-67737 | If the generate_ login certificate scli command is run without | |
parameters, it fails. | Run the command with a single known parameter (scli — |
generate login certificate –username for example) or use the full help request scli — help — generate login certificate.
MDM
Issue ID | Symptom | Recommended action |
---|---|---|
SCI-65059 | IP addresses are not rebalanced when MDM disconnects from SDT. |
- If an SDT is unreachable, the SDT_NOT_CONNECTED_TO_HO
- ST alert is raised.
- You can use connectivity monitoring utilities (such as ping) to monitor the network health.
SDS
Issue ID | Symptom | Recommended action |
---|---|---|
SCI-67744 | All SDS devices get into an error state during and after server |
reboot. This can happen if you run NVME IO for a long time, then run reboot -f
now.| Do not use -f with the reboot now command.
SCI-67359|
- If a device-at-fault event occurs while an SDS is in protected maintenance mode (PMM), some capacity may become unwriteable, resulting in I/O errors until the PMM is aborted.
- The device-at-fault event occurs when a device is readable but not writable.
| Remove from PMM.
SDC
Issue ID | Symptom | Recommended action |
---|---|---|
SCI-75418 |
- A user writing a script to orchestrate replication failover or switchover for SDC volumes must have a way to know when the destination volumes are R/W. Currently, the failover state = DONE when the call to change the access mode is made. This situation makes it difficult to write a failover script that runs successfully. PowerFlex does not provide a state that the automation script can read to determine whether the volumes are accessible.
- This situation can happen when SCSI Persistent reservation is not in use.
| None.
SDT
Issue ID | Symptom | Recommended action |
---|---|---|
SCI-76885 | Remove job gets stuck “in progress” and is not seen in the progress |
for any of the SDTs. The operating system crashes and the data are not
accessible until the reboot.| None.
SCI-77134| Panic in an SDT occurs when an NVMe host is running on the same
machine as the SDT. NVMe connect-all command that should have been finished
does not finish and uses up all the CPU resources on the machine. You may see
a temporary drop in performance until the SDT reboots.| None.
SCI-76523| Multiple NVMe kernel crashes occur in a data mobility workflow.
This problem has been observed in an RHEL9 environment. All the processes on
the server are impacted during the reboot. If the SDS resides on the server,
the system is degraded. If the primary MDM is on the server, a switchover
occurs.| Run the SDTs on separate servers.
SCI-76303|
- In an NVMe configuration with load balancing, the I/O controllers may not be created on sysports on some hosts when changing max sysports to 13 in 1 K hosts.
- After changing the max sysports, you may notice that some of the hosts had sysports not connected, but all should be connected.
| Manually perform the connect using the NVMe CLI.
SCI-74444| Mount mapped volumes over network latency is very slow.| None.
SCI-69737| Ubuntu 22.04 gets stuck in “connecting/resetting” NVMe connections
state when attempting to establish I/O and network connections.| None.
SCI-69736| NVMe host restarts when I/O and network errors occur on SLES 15
sp4. You may see many failed connection attempts with the following error
message: Error: Trying to connect new controller to already connected port|
None.
SCI-67009| In some cases where the number of hosts and active connections is
close to using the maximal number of NVMe controllers permitted by the NVMe
standard, adding a new SDT to the system may fail.|
- Disconnect one or more hosts from the system to allow the system to reclaim NVMe controller IDs. While the addition of the
- SDT is blocked, the system can still function properly and serve all currently connected hosts.
SCI-66722|
- It is possible to remove 2 SDTs that are the only paths of a volume.
- When removing 2 SDTs, after removing the first one, the MDM will replace it in the host connectivity goal with a port from the other SDT and will update all paths that used it with system-ports from other SDTs. (Some might get a path from the new port in the goal.) When removing the second one, the MDM does the same as in the first removal. However, now some mappings that got the first new port in the goal after the first removal might also get the second
| Dell Technologies recommends not removing or entering into maintenance mode
a number of SDTs that is greater than or equal to the number of paths per
volume, without reconnecting the hosts.
Issue ID| Symptom| Recommended action
---|---|---
| new port in the goal. Those mappings stay without connection.|
SCI-66645|
- An incorrect alert definition is provided for SDT_MULTIPLE_DISCONNECTIONS_FROM_STOR AGE_BACKEND_COMPONENTS.
- **** After bringing an interface down on an SDS, SDTs disconnect from it as expected and an alert is generated and processed by PowerFlex Manager. Upon recovery (NIC up), the events confirm that the SDTs and SDCs are connected back to that interface. However, this alert stays in the user interface. Sometimes, SDT alerts do not get properly cleared.
| None.
SCI-66285| SDT performance drops approximately 30% when SDT processes span 2
numas. Deploying SDT and SDR on the same server can lead to reduced
performance.| Avoid deploying SDT and SDR on the same server.
SCI-64187| NVMe namespace paths may change following disconnect and reconnect
to PowerFlex NVMe Target, such that volumes may be used by different paths.
Use by-id paths to maintain a stable path to devices across disconnect
operations.| Use /dev/disk/by-id/
SDR
Issue ID | Symptom | Recommended action |
---|---|---|
SCI-70298 | If you use a CSV file to configure the PowerFlex cluster, it may |
fail to add an SDR. The failure produces an error that says “There is no available replication capacity”. The cause of the failure is that there was not enough journal capacity to add the SDR.| Adjust the journal capacity.
PowerFlex Manager
Issue ID | Symptom | Recommended action |
---|---|---|
VXFM-36773 | Expansion of fault sets on a storage-only resource group is | |
failing. This failure affects multi-network deployments with fault sets. |
None.
VXFM-36355| A hyperconverged resource group with multiple networks and
replication is failing on SVMs| None.
VXFM-36338|
- On the Resources page, the View Details screen is not showing all firmware and software components for a deployed resource group.
- The Resource Groups page is showing these components.
| Look at the compliance report for the resource group to see the correct list
of firmware and software components.
VXFM-36320| CSV deployment fails due to sshd security settings.| Remove
additional settings from SSH config file.
VXFM-36315| The Resource Group Details page is not showing the MVM tag
next to data networks for the PFMC service. This can happen if you| If the
other IPs for the MVMs are from a static network, you can see those IPs on the
Resource Group Details page without the MVM tag.
Issue ID| Symptom| Recommended action
---|---|---
|
- define GPL networks (flex data) as static instead of DHCP. In this case, then PowerFlex Manager shows data networks for MVMs, but does not show “MVM” next to the networks.
- ** Currently, the MVMs have more than one IP address: one management IP and two data IPs. According to the current implementation, the “MVM” tag shows only with the management IP of the MVM only in the Resource Group Details** page.
|
VXFM-36270| On the Resources page, the hover help for the Hostname
field in the Discovery Wizard does not display any information.| Click
the ? button in the upper right corner of the window.
VXFM-36255| Firmware and software updates are not blocked in a resource group
when CloudLink Center is non-compliant. PowerFlex Manager permits you to
initiate the update, but the update fails.| Be sure to upgrade CloudLink
Center before performing firmware and software updates.
VXFM-36253|
- After a one-time migration from 3.x to 4.x, health monitoring may report “Powerflex Unreachable”. When the one-time migration is complete, the gateway version may still be 3.x. In this situation, subsequent operations are not performed, such as updating resource group details.
- **** This issue is not persistent. Health monitoring will correct itself once the gateway is updated from 3.x to the 4.x.
| None.
VXFM-36244| If you upgrade the PowerFlex System gateway after a one-time
migration from 3.x to 4.x, you are not able to perform a non-disruptive
upgrade on the resource group unless it is removed and added back.| Remove the
resource group and then add the existing resource group again.
VXFM-36202| Installation with SSH keys uses the ansible- generated SSH key,
instead of the customer key. This issue causes an install failure in the case
where customer PFMP nodes have configured a custom location for authorized
keys files to be placed. CMO automation unnecessarily generates its own keys
and copies to the PFMP nodes, but they always copy to ~/.ssh/ authorized_keys,
which may not be the correct location.| The options to work around the failure
are as follows:
- Remove the customization of authorized_keys location.
- Exec into the CMO installer docker container running on the PFMP Installer node and manually copy the customer key to / root/.ssh/id_rsa. Then, retry the install. The installation will use the customer key, instead of the CMO generated key.
VXFM-36099| Ubuntu deployment is only supported via the CSV option.| None.
VXFM-35909| If multiple virtual routing and forwarding (VRF) instances are
configured on a Dell OS10 switch, a firmware update fails. You must upgrade
the switch manually with this configuration.| Upgrade the switch manually.
VXFM-35808| CSV based deployment using SSH keys of type RSA with RHEL 9 nodes
is failing.| Use username/password, or SSH key with type id_ecdsa.
VXFM-35792| Volume creation fails without displaying an error message
indicating that the creation failed. This situation might arise if the
requested volume size exceeds the volume allocation limit of 1048576.| None.
Issue ID| Symptom| Recommended action
---|---|---
VXFM-35563| PowerFlex Manager does not present the current status of MDM
cluster nodes on the Resources page. MDM changes are not being processed
correctly in the user interface.| Wait for the hourly inventory of the
PowerFlex System gateway, or run a manual inventory to update the MDM cluster
information.
VXFM-35398| An attempt to modify event publisher parameters for a stand-alone
NAS server fails when the publisher contains an SMB server account.| For a
stand-alone NAS server, the event publisher must have a “custom user account”
specified.
VXFM-35355| For software-only deployments where SSH Key pair based
authentication needs to be used, the OS User and OS Admin credentials need to
have a password string defined. However, this password is not used. The
password is required to support compatibility with rack and appliance based OS
credentials.| Provide a dummy password.
VXFM-35247|
- On the system capacity dashboard, the Total Capacity shown under Usable Capacity is supposed to represent the overall usable capacity of the system. However, if you trigger an
- SDS failure by putting one SDS into instant maintenance mode, the Total Capacity and Free Capacity values increase, which is not correct. This issue applies to the main dashboard capacity, as well as to the Protection Domain and Storage Pool capacity reports.
| After exiting instant maintenance mode on the SDS, all values should return
to normal.
VXFM-35230| An incorrect error message is displayed on the Resources page in
PowerFlex Manager when a power cable is pulled out from the server.| Log in to
iDRAC to see the actual cause of the failure.
VXFM-34926| For PowerFlex file deployments that use a global namespace, the
single namespace links are restricted to the single namespace quota limit,
irrespective of their own quota limits. This situation can arise when there is
a collision between the name of the unified namespace and the name of the file
system.| Avoid using the same name for the unified namespace and the file
system.
VXFM-34912| If you modify the event publisher to MSRPC protocol with CEPA
servers in IP format, the modification fails without showing a failure message
in the user interface.| When using the MSRPC protocol, be sure that all CEPA
servers are in FQDN format.
VXFM-34909| CSV deployments may fail when you use a non- default SSH key name.
For cloud and software deployments only, users can only use a standard/
default name. This limitation applies only to CSV deployments, and not to rack
or appliance.| Use the default name.
VXFM-34531| If you use a CSV file to extend a PowerFlex cluster with a
duplicate SDC name, you may see no warning or error message. The new SDC is
installed, but it has no name.| Rename the SDC to work around this issue.
VXFM-34458| The primary MDM node log is missing from the troubleshooting
bundle log when running the troubleshooting bundle for the first time on a CSV
deployment setup.| Use the command add_ certificate to add the CA to the CLI’s
truststore.
VXFM-34388| For PowerFlex file deployments that use CEPA, the CEPA CEE server
connection shows “ONLINE” when an invalid password is passed for a custom user
in the event publisher. If you replace a valid CEPA or CAVA user password|
None.
Issue ID| Symptom| Recommended action
---|---|---
| with a wrong one, the server may continue to work using the old Kerberos
ticket for about 10 hours, until this ticket expires.|
VXFM-34381| The DataMobility Test Remote Connectivity API fails to respond for
the first time when a large number of volumes are mapped to the host (Source
system).| Try again after a few seconds and you should see the output.
VXFM-33379| When the MDM is not connected to the Block gateway, the gateway
returns default version “4.0”. This version number is a transient value. Once
the MDM is connected (a resource group is deployed), the value is updated to
list the MDM version installed on the cluster.| None.
VXFM-31338 and VXFM-31116| A user with the Snapshot Manager or Replication
Manager user role is not able to create, map, or unmap snapshots.| Use another
role such as Super User or System Admin to manage snapshots.
VXFM-31232|
- During a 4.0.0.1 to 4.0.1 Upgrade, NFS requires an extra load balancer (LB) IP due to changes to local external traffic policy. This extra LB
- IP used during the upgrade must be freed up after the upgrade. If you attempt to configure Dell SupportAssist on this appliance now, it fails, because there are no spare LB IPs to configure it.
|
VXFM-31230| The Getting Started page presents an empty page after a
CSV deployment. If you click the Deploy with Installation File
button, then click Next and Cancel , you see an empty page if you go
to Settings and click Getting started.| Refresh the browser, or
log out.
VXFM-31163 and VXFM-29528| The Modify IP Role feature is not working for SDRs
and SDTs.| Use the REST API instead.
- The REST command is modifyIpRole. For example: /api/instances/Sdt::
/action/ modifyIpRole -d ‘{“ip”:” ”, “newRole”:” ”}’ - **** The role can be one of the following strings: StorageOnly, HostOnly, StorageAndHost
VXFM-31160| When you create a volume on the Block tab, the Map button
does not open the Map Volumes to Hosts window after the volume
is successfully created.| Click the Cancel button and try again.
VXFM-31093| While registering SupportAssist from the Settings page,
PowerFlex Manager enables two policies by default once the registration is
successful. Instead of enabling the policy that was already there, PowerFlex
Manager creates a second one.| Delete the duplicate entry if you do not want
to use it.
VXFM-30855| The MDM events extractor now supports multiple IP addresses for
each MDM. If the system is configured with two or more management IP addresses
per MDM, the extractor tries to connect to each one. If the connection to
multiple interfaces is lost, the| None.
Issue ID| Symptom| Recommended action
---|---|---
|
- extractor does not recognize the disconnect and thinks that it is still connected, and does not show an alert indicating that all are down.
- **** If only one connection goes down, you do see an alert.
|
VXFM-30806| When an LDAP user is assigned to an LDAP group, and the LDAP group
is configured with a user role, a REST login command may fail with an error
stating “no role assigned to user”. This failure can happen if you delete the
LDAP user, and try to log in with that user.| Define groups before adding
explicit users. Also, If necessary, keep another local or federated user that
can be used to log in.
VXFM-30798| Running the reset_PFMP.sh script reboots all three nodes
simultaneously. If they are co- resident nodes running PowerFlex, this will
cause a data unavailability condition on the PowerFlex cluster.| Do not run
the reset_PFMP.sh script or deactivate the PowerFlex protection domain prior
to running it.
VXFM-30792| On the Getting Started page, If you try to deploy a CSV
installation file that has errors, the Upload Installation CSV button is
disabled after the error message appears. This button should be enabled to
allow you to upload a fixed file.| Close the wizard and open it again. Then,
upload the fixed file.
VXFM-30663| Under rare circumstances, some snapshots may be missing from the
file system user interface.| Use the export mountpoint to view the missing
snapshots.
VXFM-29962| During an upgrade, a standby PostgreSQL node may end up in a
failed state.| None.
VXFM-29896| When reconfigure network after docker already running the
install_PFMP.sh phase failed.| None.
VXFM-29892| Remove any text from the UI which supports the statement that
additional networks can be added for SO resource group.| None.
VXFM-29880| The block-legacy-gateway still shows under Target PowerFlex
Gateway.| None.
VXFM-29803|
- A service that was imported into version 3.8 of PowerFlex Manager cannot use Update Resource Group Details in version 4.x.
- ** This situation could happen if you perform a one- time migration on a 3.8 environment that includes a service that was originally imported through Add Existing Service. If you remove a node from the resource group after the migration, and then perform Update Resource Group Details** , you might see a 500 exception.
| Remove the resource group, and readd it by using Add Existing Resource
Group. This workaround ensures that the resource group is re-created with
the correct data for the nodes.
VXFM-29710| The old REST API for logging out does not work. If you logout with
GET https://
VXFM-29705| When a PowerFlex cluster deployment fails, you may see errors from
a previous run if you attempt to redeploy repeatedly in quick succession.|
None.
Issue ID| Symptom| Recommended action
---|---|---
| This error is a logging issue only. If you run deployments over and over
quickly, the logs may bleed over into subsequent deployments.|
VXFM-29656| The Notifier service fails to handle ALM events with
“send_to_srs”=false due to a key error. This results in some low-level
information being sent when it should not be.| None.
VXFM-29637| It takes PowerFlex Manager up to 40 minutes to fully load after
reboot, crash, or power off.| None.
VXFM-29619| Delete Resource Group does not remove nodes from CloudLink
Center in the case of resource groups with encryption. The nodes are still
present, but they are in a Disconnected state.| None.
VXFM- 29602| The PowerFlex gateway still responds to the old alert query API,
but this was deprecated.
- **** In older versions of PowerFlex, alerts were queried by the gateway using the following API: /api/types/Alert/instances
- **** In this release, the alerts are handled by the alert service and queried by using this API: / rest/v1/alerts
**** The deprecated API should return an error, but instead it responds normally and returns incorrect data that does not include some alerts.
| Do not use the deprecated API. Use the new API instead.
VXFM- 29600| The node deployment status on the Resources page is set to
Deployment Cancelled state after a successful non-disruptive update. This
is a temporary state and should be corrected in a few minutes.| Check again in
a few minutes to see if the deployment status has been updated.
VXFM-29584| The exception only flag for IM log collection is not supported.
This flag has been deprecated and is ignored.| None.
VXFM-29543| The management workflow to allow swapping primary and backup nodes
has not been added to the restricted operations after a NAS server has entered
into an out-of-service state.
This situation might occur in the following scenario:
- You make a NAS storage pool full.
- The NAS server on the storage pool becomes read-only.
- You try to move the NAS server (this operation is a prohibited.)
- You try to perform a swap of the NAS server (this is successful).
**** This issue has no visible impact on file service operations.
| None.
VXFM-29500| PowerFlex Manager does not provide the ability to place an SDT in
maintenance mode within the user interface.| None.
Issue ID| Symptom| Recommended action
---|---|---
VXFM-29496| If you run the reset_PFMP.sh script to remove an old install and
reinstall PFMP, the script removes pre-requisite software rpms:
- jq
- nmap
- skopeo
**** The install fails if these RPMs are not there already.
| Install the missing RPMs again.
VXFM-29494| Filtering events by timestamp does not work correctly with
milliseconds. For example, the following API call might return events that do
not match the filter:
- **** https://10.234.222.15:31943/rest/ v1/events? filter=timestamp+gt+2022-07-05T14
- :57:27.807Z&filter=service_instan ce_id+le+Value+above+limit+`-=/
- <>,.?|;:[]
- {}&order=resource_id.dsc
| None.
VXFM-29404| A hyperconverged resource group fails if an NFS datastore is
already present.| Remove the NFS datastore and retry the resource group.
VXFM-29386| The Latency graph on the dashboard does not show any data for
NVMe/TCP.| None.
VXFM-29304| Some event and alert services cannot recover from a configuration
or certificate change in the AMQ service. All services may lose connection to
AMQ and reconnection attempts may fail.| Restart the pod of services that did
not disconnect.
VXFM-29291| On the File > NAS Servers or File > File Systems
page, the performance details do not get updated on the side pane for a
selected NAS server or file system.| Click somewhere else on the page and
click back again to see the performance details.
VXFM-29272| A hyperconverged deployment fails in a partial network
configuration when DNS is not configured in the hypervisor management
network.| Configure DNS.
VXFM-29234|
- When you create a login certificate and it later expires, an attempt to login with the expired certificate gives a misleading error message: scli –login — p12_path /root/.scli/admin_cert.p12 –p12_password password Error: Failed to connect to MDM 127.0.0.1:8611
- **** There should be some indication that the certificate is no longer viable and you need to create a new one.
| None.
VXFM-29190| NVMe drive replacement fails with the error “Removal of the
operating system failed”. The error is confusing because it says it failed,
but you can remove the drive without issue and the| None.
Issue ID| Symptom| Recommended action
---|---|---
| new drive is detected and can be added back to PowerFlex and CloudLink.|
VXFM-29174| The Edit Management Software Upgrade Settings page does not
have a Test Connection button. However, when you click Save ,
PowerFlex Manager displays a message indicating whether the supporting
connections that are required for the upgrade are valid.| None.
VXFM-29095| There is no way to delete a source or destination on the
Notification Policies page.| Remove or disable all the policies involving
this source or destination.
VXFM-28986| PowerFlex Manager allows you to deploy 16 nodes for a PowerFlex
File (NAS) compute-only deployment. This is not supported. The limit is 16
nodes. The user interface should block NAS deployments that exceed 16 nodes.|
None.
VXFM-28983| When trying to add an additional node to a resource group, you may
see the deployment fail with a 500 error, if the storage pool media type is
set to “transitional”. The “transitional” media type is not supported.| None.
VXFM-28829| If you click Add Template in the Deploy Resources section
of the Getting Started page, the user interface shows the Create
wizard as expected. After selecting Create a new template , entering a
Template Name , and clicking Next , the Create Template page shows
up correctly. After entering all fields and clicking Save , the user
interface does not show the template details to allow further editing of the
template, as it would if you clicked Lifecycle > Templates and then
clicked Create. However, the template is created.| Navigate to
Lifecycle > Templates. You see the template in the list under My
Templates. You can then click the template name to edit the template as
expected.
VXFM-28828| The Compliance Versions page is not refreshing to show the new
state of the compliance file when Allow Unsigned File is selected.|
Refresh the page or navigate away from the page and come back. The
Compliance Versions page then shows the state correctly.
VXFM-28715| You are unable to save changes in the Destination Protocol
Settings (SupportAssist) window if you attempt to change the connection type
from Connect via Gateway Server to Connect Directly.| Deregister
before you try to change from one connection method to another.
VXFM-28693| The error message displayed in PowerFlex Manager is not clear when
the logged in user tries to change their password.| None.
VXFM-28532|
- Resizing the service volumes (vCLS volumes) should be blocked by PowerFlex Manager.
- Currently, you can increase the vCLS volume size. After resizing the volumes, you may also see unexpected behaviors. For example, you may see a message saying that the service is in lifecycle mode because the vCLS volumes are on local storage.
| None.
VXFM-28433| When trying to export a template without an encryption password,
you may see an error.| Create a password on the Backup Settings
page and the export works as expected.
VXFM-28291| An ambiguous error appears during node expansion if a reverse DNS
lookup for a| None.
Issue ID| Symptom| Recommended action
---|---|---
|
- hostname fails to find an IP address. The
- Summary screen for adding the node shows:
- An unexpected error occurred on the system. Retry the operation later.
|
VXFM-28281| PowerFlex Manager allows multiple instances of an iDRAC password
update job to run on the same node simultaneously.| None.
VXFM-28194|
- If there is a larger than expected time difference (over 1 hour) between PowerFlex Manager
- and the PowerFlex storage nodes, an upload license action may fail with the following error: License Enforcement – Wrong
- Command Parameters. This error is displayed on the License Management page in PowerFlex Manager.
- In the PowerFlex Manager log file, the following error appears: “error_code”:62,”error_message”:”Li cense Enforcement – Wrong Command Parameters.”
- **** In the primary MDM logs /opt/emc/ scaleio/mdm/logs/trc.z.XX, the error displays as follows: Error, license activation date in the future
| Align the time between the management platform and storage nodes and upload
the license again.
VXFM-27411| Uploading a 4.0 license to an existing service that is still on
3.6 should show a more meaningful error message.| Apply the license through
the CLI.
VXFM-27388| If you upload a certificate file you have uploaded before using
the same name you have used before, PowerFlex Manager does not display
an error message and overrides the existing certificate.
| None.
VXFM-26570| An attempt to tear down a storage-only CloudLink resource group
does not remove the machine groups from CloudLink Center.| None.
VXFM-26550| If you run the command “powerflex_cli events quwery
–session_token 98329575cf390107 –limit 2 –order timestamp.asc”
with wrong command flag “quwery” , the command fails with error “Error:
unknown flag: –limit”. This is the incorrect error message.| Run the command
with the correct command flag: “powerflex_cli events query
–session_token 98329575cf390107 — limit 2 –order timestamp.asc”
VXFM-26549| When using powercli to query events with filter “severity in
(MAJOR,MINOR)” it fails with a parsing error. This error occurs because the
“in” operator does not exist in the CLI.| The same query can be achieved by
running the query a few times, once for each value in the “in” clause.
VXFM-26476| When using the REST API to query event history, if there is an
error in the filter field, the filter is ignored, and the unfiltered list is
returned instead of an error message.| Correct your query and run it again.
VXFM-25895| PowerFlex Manager is unable to configure a Dell OS10 switch for
deployment.| None.
Issue ID| Symptom| Recommended action
---|---|---
VXFM-25284| While creating a snapshot rule, you need to provide the time of
day. By default, the value that is populated on this field is current time in
EST. However, internally, the snapshot rule is created with the value in UTC.
This may lead to confusion as snapshots are not getting created as expected.|
None.
SCI-67737| If the generate login certificate scli command is executed
without parameters, it will fail.| Run the command with a single known
parameter (scli –generate login_ certificate –username for example) or use
the full help request scli –help — generate _login _certificate.
Operating system known issues and limitations
This section lists known issues and limitations for specific operating systems.
Issue number & SR number | Problem summary | Workaround |
---|---|---|
VXFV-360 | The device name appears incorrectly as a non- PCI device instead of |
iDRAC, but the current and baseline versions are accurate (6.00.30.201 to
6.00.30.202, respectively).| Dell recommends upgrading the OME catalog to the
latest version.
| PowerFlex nodes running CPLD 1.0.7 stop responding during Power On Self-Test
(POST) when upgrading to certain RCM or IC packages that include BIOS 1.8.2
and iDRAC 6.00.30.202.| Before upgrading to the latest version of PowerFlex,
ensure that the PowerFlex nodes are running CPLD 1.0.8 or later.
For details, see https://www.dell.com/support/ kbdoc/en-us/000205925.
VXFV-296| Mixing the Mellanox CX-6 100GbE NIC driver with the Broadcom
PCIe/OCP 25GbE NIC driver is not supported.| Remove the bnxt_en driver and
install the Mellanox driver.
VXFV-283| iDRAC support for “Prepare for Removal” on PowerEdge
R650/R6525/R750/ nodes fails.| NVMe hot-swap on Linux operating systems is
supported. Skip the Prepare for Removal step in iDRAC.
VXFV-265| During execution of the command create- namespace with 4k alignment
on RHEL 8.4, the following error is encountered:
Warning: namespace0.0 unable to validate alignment
| This is a false notification. The command result is as expected, and the
resulting DAX device can be used with PowerFlex acceleration devices.
VXFV-243| Upgrade of a RedHat-based operating system to RHEL 8.3 fails if the
node contains NVDIMMs.
This is due to a known issue on RHEL
8.3: https://access.redhat.com/documentation/ en-us/red_hat_enterprise_linux/8/html- single/ 8.3_release_notes/index#known- issue_installer- and-image- creation
| Follow the procedures described in “RHEL/ CentOS upgrade to version 8.3” in the .
Resolved issues in 4.5
Resolved issues are defects that exist in the previous release but are
resolved in the 4.5 release of PowerFlex and PowerFlex Manager.
Issue ID | Symptom |
---|---|
VXFM-35527 | When a Node is scaled up using the scaled-up CentOS as a |
duplicate, the SVM OS Type under SVM OS Settings is a duplicate.
VXFM-35157| After a one-time migration, the MDS gateway moved to a critical
state with the error “MDM_CONNECTION_LOST, in the MDM cluster/PowerFlex
gateway”.
VXFM-35132| SDC installation for ESXi base installation fails when there are
multiple ingress instances and ESXi management is not the first ingress that
is defined on the cluster.
VXFM-34878| On completion of a successful NDU on the Resource group, the nodes
are compliant but the Gateway moves to critical state and alert messages are
displayed.
VXFM-34612| The 4.0.2 software catalog does not have SLES 15 SP4 in it, so
upgrades performed through the user interface for that operating system do not
work.
VXFM-34284| Many pods fail after an increase in inventory and, some containers
restart at regular intervals even after a long time since the failure.
VXFM-31193| After a nondisruptive upgrade completes on a storage-only resource
group, the Tie Breaker node compliance state is in ‘Pending Upgrade’, even
though the upgrade completed successfully. The state is reported incorrectly
in the user interface.
VXFM-31191| If the CIFS password begins with a special character, such as a
dollar sign ($), a restore to an existing cluster may fail.
VXFM-31185| If you attempt to perform a CSV deployment in the user interface
without loading the MDM RPM, the deployment fails with an unhelpful message.
The error should indicate that the MDM RPM is missing.
VXFM-31179| If you try to delete a hyperconverged resource group, the teardown
operation does not delete the vCenter cluster. Also, the wizard for deleting
the resource group does not show the checkbox that allows you to delete the
cluster and remove it from vCenter.
VXFM-30889| When removing a resource group, you do not have the option to
choose whether resources should be left in a managed or unmanaged state.
Instead, PowerFlex Manager automatically leaves the nodes in a managed state.
VXFM-30624| After performing a new resource group deployment, PowerFlex
Manager shows a node with an update failed status, but the deployment was
successful. This status is incorrect, since no update was performed.
VXFM-29795| When importing a version 3.6 PowerFlex cluster to PowerFlex
Manager, you may see that when the MDM primary node was changed, the
certificate was not approved before. Therefore, the user is not recognized and
the import cannot be done.
VXFM-29543| The management workflow to allow swapping primary and backup nodes
has not been added to the restricted operations after a NAS server has entered
into an out-of-service state.
- This situation might occur in the following scenario
- You make a NAS storage pool full.
- The NAS server on the storage pool becomes read-only.
- You try to move the NAS server (this operation is prohibited.)
- You try to perform a swap of the NAS server (this operation is successful).
This issue has no visible impact on file service operations.
VXFM-29381| The Summary page of the Initial Configuration wizard
remains static for 30 seconds while PowerFlex Manager is enabling
SupportAssist.
VXFM-29294| The dashboard I/O performance numbers do not correlate with I/O
performance numbers reported by SCLI.
Issue ID| Symptom
---|---
VXFM-28034| If you create volumes on the Block page, volume creation is
cancelled when you switch away from this page. Volume creation should be
continued in the background. Instead, volume creation is stopped and there is
no progress or completion status when the Block page is opened again.
VXFM-27967| The View Details page for Cisco switches shows a blank page
and no metrics.
Environment and system requirements
This section provides information on the contents of the PowerFlex 4.5 software packages.
Download location
-
The PowerFlex complete software package, containing most of the packages listed below, can be downloaded from the following location:
https://www.dell.com/support/home/en-us/product- support/product/scaleio/overview -
The RCM for PowerFlex rack can be downloaded from the following location
PowerFlex rack RCM software
Packages
Package name | Size | Contents |
---|---|---|
PFMP bundle | ~19.2 GB | PFMP2-4.5.0-1189.tgz |
RCM for PowerFlex rack | ~24.6 GB | Flex_RCM_3_7_3_0_r31.zip |
Intelligent catalog for PowerFlex appliance | ~23.4 GB |
Intelligent_Catalog_45_373_00_r31.zip
Software-only ZIP| ~5.9 GB| Software_Only_Complete_4.5.0.0_287.zip. Includes
the following
- PowerFlex_4.5.0.0_287_Complete_Core_SW.zip (3.4 GB)
- PowerFlex_4.5.0.0_287_SDCs_for_manual_insta ll.zip – SDC RPMs (0.6 GB)
- PowerFlex_Software_4.5.0.0_287_r1.zip – software-only catalog (1.9 GB)
Compatibility file| | cm-20230901.gpg (compatibility file)
PowerFlex Manager OVA ZIP| ~24.5 GB| PowerFlex_Manager_4.5.0-1189.zip
- PFMP2-4.5.0-1189.ova (PFMP _Installer for installing Kubernetes cluster) (23 GB)
- pfmp-k8s-153L-20230809.ova (Kubernetes OVA) (2.3 GB)
Where to get help
The Dell Technologies support site contains important information about
products and services, including drivers, installation packages, product
documentation, knowledgebase articles, and advisories.
A valid support contract and account might be required to access all of the
available information about a specific Dell Technologies product or service.
References
- 8.3 Release Notes Red Hat Enterprise Linux 8 | Red Hat Customer Portal
- RCM
- Submit Form
- Support for PowerFlex rack RCM Software | Overview | Dell Australia
- 15G PowerFlex Family running CPLD 1.0.7 can hang during POST when updating to BIOS 1.8.2 and iDRAC 6.00.30.202 | Dell US
- Dell PowerFlex Software - Technical Documentation | Dell US
- Sign In | Dell US
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>